Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Radiological Medicine and Protection ; (12): 590-593, 2015.
Article in Chinese | WPRIM | ID: wpr-480985

ABSTRACT

Objective To investigate the correlations in target volumes based on positron emission tomography CT (PET/CT) and the end-expiration phase of four-dimensional CT (4D-CT) images for non-small cell lung cancer (NSCLC).Methods Seventeen patients with NSCLC sequentially underwent three-dimensional CT (3DCT),4D-CT and 18F-FDG PET/CT thoracic simulation scans.The gross target volume (GTV) was contoured on the end-expiration phase (50%) of 4D-CT and defined as GTV50%.The internal gross target volumes (IGTV) based on PET/CT images (IGTVPET) were determined by the standardized uptake value (SUV) 2.0 (IGTVPET2.0) and 20% percentage of the maximal standardized uptake value (SUVmax) (IGTVPET20%).The following parameters were calculated to analyze the correlation between IGTVPET and GTV50% in volume ratio (VR) and conformity index (CI):maximum transverse diameter of GTV50%,volume of GTV50%,the displacement of GTV in the cranial-caudal direction and 3D Vector calculated from 4D-CT dataset as well as the SUVmax.Results There was no significant correlation between the VR of IGTVPET2.0 to GTV50% and the maximum transverse diameter of GTV50%,volume of GTV50%,the displacement of GTV in the cranial-caudal direction,3D Vector and the SUVmax (P > 0.05).The VR between IGTVPET20% and GTV50% inversely related to maximum transverse diameter of GTV50%,volume of GTV50% and SUVmax (r =-0.663,-0.669,-0.752,P <0.05).The CI between IGTVPET2.0 and GTV50% positively related to volume of GTV50% and maximum transverse diameter of GTV50% (r =0.613,0.483,P < 0.05).Conclusions 3D PET images provide a time-averaged image of the tumor during the numerous breathing cycle.They fail to include the full information of moving tumor.The target volumes based on 3D PET might not reflect the real IGTV of NSCLC.

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 683-687, 2014.
Article in Chinese | WPRIM | ID: wpr-453871

ABSTRACT

Objective To compare volumetric size, conformity index (CI), degree of inclusion (DI) of internal gross target volumes (IGTV) delineated on 4D-CT-MIP and PET-CT images for primary thoracic esophageal cancer. Methods Fifteen patients with thoracic esophageal cancer sequentially underwent enhanced 3D-CT, 4D-CT and PET-CT simulation scans. IGTVMIP was obtained by contouring on 4D-CT maximum intensity projection ( MIP). The PET contours were determined with nine different threshold methods (SUV≥2?0, 2?5, 3?0, 3?5), the percentages of the SUVmax(≥20%, 25%, 30%, 35%, 40%) and manual contours. The differences in size, conformity index (CI), degree of inclusion ( DI) of different volumes were compared. Results The volume ratios ( VRs) of IGTVPET2. 5 to IGTVMIP , IGTVPET20% to IGTVMIP, IGTVPETMAN to IGTVMIP were 0?86, 0?88, 1?06, respectively, which approached closest to 1. The CIs of IGTVPET2?0,IGTVPET2.5,IGTVPET20%,IGTVPETMAN and IGTVMIP which were 0?55, 0?56, 0?56, 0?54,0?55, respectively, were significantly larger than other CIs of IGTVPET and IGTVMIP (Z= -3?408-2?215,P 0?05). Conclusions The targets delineated based on SUV threshold setting of≥2?5, 20% of the SUVmax and manual contours on PET images correspond better with the target delineated on maximum intensity projection of 4D-CT images than other SUV thresholding methods.

SELECTION OF CITATIONS