Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Nucleus (La Habana) ; (65): 51-55, ene.-jun. 2019. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1091390

ABSTRACT

Abstract Total Body Irradiation (TBI) is a radiotherapy technique that consists of irradiating homogeneously the whole patient's body and it is characterized by an extended source to surface distances and the use of large irradiation fields. The limitations of the available input data and inherent problems with the calculation procedures make it very difficult to accurately determine the dose distributions in TBI. For these reasons, it is highly recommended to use In Vivo Dosimetry (IVD), to guarantee the quality of TBI treatments as a direct measurement of the delivered dose. An IVD QA system was implemented based on semiconductor diodes and radiochromic films. For the commissioning of the system, both detector types were calibrated independently, using as reference an ionization chamber with a valid certificate in terms of absorbed dose to water (Dw). This guarantees the traceability of the measurements. An experiment was carried out to simulate a clinical TBI procedure to a phantom. In this way, the calibration of the dosimetry system was confirmed.


Resumen La irradiación total del cuerpo (TBI) es una técnica de radioterapia que consiste en irradiar de manera homogénea todo el cuerpo del paciente y se caracteriza por una fuente extendida a distancias superficiales y el uso de grandes campos de irradiación. Las limitaciones de los datos de entrada disponibles y los problemas inherentes con los procedimientos de cálculo hacen que sea muy difícil determinar con precisión las distribuciones de dosis en TBI. Por estos motivos, es altamente recomendable utilizar la dosimetría in vivo (IVD), para garantizar la calidad de los tratamientos de TBI como una medida directa de la dosis administrada. Se implementó un sistema IVD QA basado en diodos semiconductores y películas radiocromáticas. Para la puesta en marcha del sistema, ambos tipos de detectores se calibraron de forma independiente, utilizando como referencia una cámara de ionización con un certificado válido en términos de dosis absorbida en agua (Dw). Esto garantiza la trazabilidad de las mediciones. Se llevó a cabo un experimento para simular un procedimiento clínico de TBI a un fantasma. De esta forma, se confirmó la calibración del sistema de dosimetría.

2.
West Indian med. j ; 61(8): 773-777, Nov. 2012. tab
Article in English | LILACS | ID: lil-694339

ABSTRACT

OBJECTIVE: Total body irradiation (TBI) is a choice therapy for the management of some malignancies; it is also a major cause of oxidative stress. The aim of this research is to sequentially document the effect of total body radiation on body function utilizing the sequential changes in liver function enzymes and proteins in rats. METHODS: Serum protein and liver enzymes were assessed using kits in rats exposed to total body radiations of 1.27 Gy/minute in cumulative doses to the fourth radiation at five-day intervals. RESULTS: Aspartate aminotransferase (AST), alanine transaminase (ALT) and serum protein were significantly (p < 0.05) elevated with increasing radiation. No significant differences between experimental and control groups for bilirubin concentrations were noted at any time. Serum levels of albumin were significantly (p < 0.05) increased with the first to third radiation exposures but reduced at the fourth cumulative dose exposure. CONCLUSION: Variations are associated with acute stress, inflammation which could be due to non-specific stress reaction, while fluctuations could arise as a result of tolerance and repair within the liver. These tests are significant for diagnosis of radiation-induced injury and can be important for evaluation of its severity and correct management.


OBJETIVO: La irradiación corporal total (ICT) es una terapia de elección para el tratamiento de algunos tumores malignos. También es una de las causas principales del estrés oxidativo. El objetivo de esta investigación es documentar el efecto de la radiación corporal total sobre las funciones corporales utilizando los cambios secuenciales en las enzimas de la función hepática y las proteínas en las ratas. MÉTODOS: Se evaluaron las proteínas séricas así como las enzimas hepáticas mediante el uso de kits en ratas expuestas a radiaciones corporales totales de 1.27 Gy/minuto en dosis cumulativas hasta la cuarta radiación con cinco días de intervalo. RESULTADOS: La aspartato transaminasa (AST), la alanina aminotransferasa (ALT) y la proteína sérica fueron elevadas significativamente (p < 0.05) con el aumento creciente de la radiación. No hubo diferencias significativas entre el grupo experimental y el grupo control, observándose concentraciones de bilirrubina todo el tiempo. Los niveles séricos de albúmina aumentaron significativamente (p < 0.05) con la primera de tres exposiciones a la radiación, pero experimentaron una reducción a partir de la cuarta exposición de dosis cumulativa. CONCLUSIÓN: Las variaciones están asociadas con estrés agudo e inflamación que podría deberse a una reacción a estrés no específico, mientras que las fluctuaciones podrían surgir como resultado de la tolerancia y la regeneración dentro del hígado. Estas pruebas son importantes para el diagnóstico de lesiones inducidas por radiación, así como para la evaluación de la severidad y el tratamiento correcto de las mismas.


Subject(s)
Animals , Male , Rats , Liver/enzymology , Liver/radiation effects , Radiation Injuries, Experimental/blood , Whole-Body Irradiation/adverse effects , Alanine Transaminase/blood , Aspartate Aminotransferases/blood , Blood Proteins/metabolism , Liver/physiopathology , Radiation Injuries, Experimental/diagnosis , Rats, Wistar
SELECTION OF CITATIONS
SEARCH DETAIL