1.
Article | IMSEAR | ID: sea-192286

ABSTRACT

Endodontic instruments play a vital role during root canal preparation. Biomechanical preparation in primary teeth is performed using the adult endodontic files. There are various disadvantages during use of adult endodontic files in primary teeth namely the length and taper of the files. Recently, an exclusive paediatric endodontic file system has been introduced for cleaning and shaping of primary root canals. This short communication describes the use of exclusive Kedo-SH manual and Kedo-S rotary file system in primary teeth.

2.
Braz. dent. sci ; 22(2): 197-202, 2019. ilus, tab
Article in English | LILACS, BBO | ID: biblio-996503

ABSTRACT

Objective: To evaluate the efficacy of rotary Kedo-S and hand K-files in shaping ability in primary canines using cone beam computed tomography. Material and Methods: Thirty extracted primary maxillary and mandibular canines were selected. Using cone beam computed tomography the teeth were scanned before instrumentation. In Group I, the teeth were prepared using stainless steel K file up to the size of 40. In the Group II teeth, U1 size Kedo-S rotary file was used in crown down technique. The instrumented teeth were scanned again with cone beam computed tomography and the images were compared. Results: The canal taper was more conical for rotary Kedo-S files as compared to K-files, which was statistically significant. Conclusion: Canal preparation with Rotary files resulted in more conical canals when compared to manual instrumentation in primary teeth that contributes to more uniform obturation. (AU)


Objetivo: Avaliar a eficácia da instrumentação rotatória com limas Kedo-S e instrumentação manual com limas Kerr na modelagem de caninos decíduos utilizando tomografia computadorizada de feixe cônico (TCFC). Material e Métodos: Foram selecionados 30 caninos decíduos superiores e inferiores extraídos. Usando a TCFC, os dentes foram escaneados previamente a instrumentação. No Grupo I, os dentes foram confeccionados com limas de aço inoxidável até o tamanho 40. Nos dentes do Grupo II, utilizou-se a lima rotatória Kedo-S tamanho U1 na técnica coroaápice. Os dentes instrumentados foram novamente escaneados por TCFC e as imagens foram comparadas. Resultados: A conicidade do canal foi maior no grupo com instrumentação rotatória em comparação com a instrumentação manual, com diferença estatística significante entre eles. Conclusão: O preparo do canal com o Rotary resulta em canais mais cônicos em comparação com a instrumentação manual em dentes decíduos, o que contribui para uma obturação mais uniforme.(AU)


Subject(s)
Pulpectomy , Tooth, Deciduous , Cuspid , Cone-Beam Computed Tomography
3.
Braz. dent. sci ; 21(4): 411-417, 2018. ilus, tab
Article in English | LILACS, BBO | ID: biblio-965835

ABSTRACT

Objective: Despite the tortuous course of primary root canal system, a paradigm shift occurred from conventional hand files to rotary system, which lead to faster, cost-effective, uniform and predictable fillings. One of the many advantages being, reduction in post-operative pain with the use of rotary system. Many rotary file systems were introduced, with the recent one, the Kedo-S. So the present study aimed to compare and evaluate the post ­ operative pain after pulpectomy using K-files, MTwo files and Kedo-S files in deciduous molars. Material and Methods: 75 teeth were randomly divided into three groups (group A ­ K-files, group B - Kedo-S files and group C - MTwo files) for pulpectomy of primary molars. Post ­ operative pain was assessed every 6,12,24,48 and 72 hours using facial pain scale. Results: 44% of volunteers in K-file group had moderate pain followed by Kedo-S group (8%) and then MTwo files (4%). Conclusion: The least post-operative pain was found in Mtwo group followed by Kedo-S group and K-file group. (AU)


Objetivo: Apesar do curso tortuoso do sistema de canais radiculares de dentes molares decíduos, uma mudança de paradigma ocorreu das limas manuais convencionais para o sistema rotatporio, o que leva a obturações mais rápidas, econômicas, uniformes e previsíveis. Uma das muitas vantagens é a redução da dor pós-operatória com o uso do sistema rotatório. Muitos sistemas de limas rotátórias foram introduzidas, como o recente Kedo-S. Assim, o presente estudo objetivou comparar e avaliar a dor pós-operatória após pulpectomia utilizando limas K, MTwo e Kedo - S em molares decíduos. Material e Métodos: Setenta e cinco dentes foram divididos aleatoriamente em três grupos (grupo A - limas K, grupo B - limas Kedo-S e grupo C - limas MTwo) para pulpectomia de molares decíduos. A dor pós - operatória foi avaliada a cada 6,12,24,48 e 72 horas, utilizando a escala de dor facial. Resultados: 44% dos voluntários do grupo K apresentaram dor moderada, seguidos pelo grupo Kedo-S, com 8%, e MTwo, com 4%. Conclusão: A menor dor pósoperatória foi encontrada no grupo Mtwo, seguido pelo grupo Kedo-S e pelo grupo K-file. (AU)


Subject(s)
Pulpectomy , Dental Pulp Cavity , Molar