Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Journal of Laboratory Medicine and Quality Assurance ; : 275-279, 2009.
Article in Korean | WPRIM | ID: wpr-228384

ABSTRACT

BACKGROUND: Real-time PCR has been widely used not only for quantification?of disease-related genes but also for detection of bacteria or viruses. In this study, we evaluated the performance of Artus HBV LC PCR kit (Qiagen, Hilden, Germany) using recently developed SLAN real-time PCR detection system (Shanghai Hongshi Medical Technology Co., Shanghai, China) to assess clinical relevance of the new instrument. METHODS: Precision, linearity and detection limit of Artus HBV LC PCR kit were evaluated using SLAN real-time PCR detection system. We also compared the SLAN real-time PCR detection system with LightCycler 1.5 (Roche Molecular System, Branchburg, NJ, USA) and ABI PRISM 7500 (Applied Biosystems, Foster City, CA, USA). WHO International Standard for HBV DNA Nucleic Acid Amplification Techniques (NIBSC code:97/750) and 40 HBV DNA positive sera were tested for this evaluation. RESULTS: Within-run and between-day coefficients of variation were 5.63%, 4.01% at 6.2x10(3) IU/mL and 1.12%, 0.80% at 2.1x10(1) IU/mL, respectively. Linearity was verified from 1.0x10(1) to 1.0x10(5) IU/mL (r(2)=1.000; slope=1.1412). Detection limit for HBV DNA was verified to be 7.54 IU/mL. It showed a good correlation with LightCycler 1.5 (r=0.9723) and ABI PRISM 7500 (r=0.9768). CONCLUSIONS: Artus HBV LC PCR kit using SLAN real-time PCR detection system showed a good precision, linearity and assay sensitivity. It correlated well with LightCycler 1.5 and ABI PRISM 7500. We conclude that it can be used in clinical laboratories for nucleic acid quantification.


Subject(s)
Bacteria , DNA , Limit of Detection , Nucleic Acid Amplification Techniques , Polymerase Chain Reaction , Real-Time Polymerase Chain Reaction
2.
Infection and Chemotherapy ; : 167-169, 2008.
Article in English | WPRIM | ID: wpr-722203

ABSTRACT

Human cytomegalovirus (HCMV) is a common human pathogen that causes morbidity and mortality in hematopoietic stem cell transplantation (HSCT) recipients. Early diagnosis of HCMV infection or reactivation, and setting threshold values for effective pre-emptive therapies, are required for appropriate HCMV disease prevention in HSCT recipients. We compared the HCMV infections detected by the two methods, LightCycler-based PCR (LC PCR) and in-house immediate early protein PCR (in-house IE PCR) with the results of a pp65 antigenemia assay as the reference. The sensitivity and specificity for the in-house IE PCR were 79.3% and 72.7%, respectively, and 82.9% and 40.7%, respectively, for the LC PCR. The correlation between the HCMV viral load and pp65 antigenemia in HSCT recipients was r=0.603 with in-house IE PCR and r=0.525 with LC PCR. The discordant results between methods and relatively low (r) values suggest that we need more study to set threshold values according to the using methods with clinical outcome.


Subject(s)
Humans , Cytomegalovirus , Early Diagnosis , Hematopoietic Stem Cell Transplantation , Hematopoietic Stem Cells , Polymerase Chain Reaction , Real-Time Polymerase Chain Reaction , Sensitivity and Specificity , Viral Load
3.
Infection and Chemotherapy ; : 167-169, 2008.
Article in English | WPRIM | ID: wpr-721698

ABSTRACT

Human cytomegalovirus (HCMV) is a common human pathogen that causes morbidity and mortality in hematopoietic stem cell transplantation (HSCT) recipients. Early diagnosis of HCMV infection or reactivation, and setting threshold values for effective pre-emptive therapies, are required for appropriate HCMV disease prevention in HSCT recipients. We compared the HCMV infections detected by the two methods, LightCycler-based PCR (LC PCR) and in-house immediate early protein PCR (in-house IE PCR) with the results of a pp65 antigenemia assay as the reference. The sensitivity and specificity for the in-house IE PCR were 79.3% and 72.7%, respectively, and 82.9% and 40.7%, respectively, for the LC PCR. The correlation between the HCMV viral load and pp65 antigenemia in HSCT recipients was r=0.603 with in-house IE PCR and r=0.525 with LC PCR. The discordant results between methods and relatively low (r) values suggest that we need more study to set threshold values according to the using methods with clinical outcome.


Subject(s)
Humans , Cytomegalovirus , Early Diagnosis , Hematopoietic Stem Cell Transplantation , Hematopoietic Stem Cells , Polymerase Chain Reaction , Real-Time Polymerase Chain Reaction , Sensitivity and Specificity , Viral Load
SELECTION OF CITATIONS
SEARCH DETAIL