Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Type of study
Language
Year range
1.
Korean Journal of Blood Transfusion ; : 31-37, 2016.
Article in Korean | WPRIM | ID: wpr-22648

ABSTRACT

BACKGROUND: Detection of anti-Kidd antibody is important because of its clinical significance. If detection is difficult due to weak serological reactivity or dosage effect, use of an enzyme method could be helpful. However, despite use of an enzyme method, we still observed weak reactivity of anti-Kidd antibody. METHODS: All identified anti-Kidd antibody cases from Jan 2012 to Aug 2015 in Asan Medical Center were reviewed. Antibody identification test was performed using the column agglutination technique using Bio-Rad ID-DiaPanel with LISS/Coombs card, Bio-Rad ID-DiaPanel-P with NaCl/Enzyme card, and ID-DiaPanel-P with LISS/Coombs card. The test results were compared. RESULTS: Sixty cases of anti-JK(a) or anti-Jk(b) were detected and tested by enzyme method. Among them, 34 (56.6%) cases showed strengthened reactivity using the ID-DiaPanel-P with NaCl/Enzyme card method. However, 26 (43.4%) cases showed weakened reactivity. Of these, 13 cases that could be tested by an additional method using ID-DiaPanel-P with LISS/Coombs card containing anti-IgG and anti-C3d showed successfully strengthened reactivity. CONCLUSION: The reactivity of anti-Kidd antibodies that was not strengthened using ID-DiaPanel-P with NaCl/Enzyme card method could be successfully strengthened by use of the ID-DiaPanel-P with LISS/Coombs card.


Subject(s)
Agglutination , Antibodies
2.
Korean Journal of Clinical Pathology ; : 422-425, 2001.
Article in Korean | WPRIM | ID: wpr-18775

ABSTRACT

BACKGROUND: There is a recent trend of increased use of the gel test for the detection of unexpected antibodies (Abs) because of its simplicity and ease with which definitive interpretation can be made. However, because of the low insurance payments in Korea, only the LISS/Coombs card is used and thus the detection rate of the cold Abs has decreased. We have studied the detection rates of the Abs in patients by using the LISS/Coombs gel test and thus evaluated the clinical usefulness of the LISS/Coombs gel test. METHODS: Abs screening tests have been carried out using the DiaMed(TM) LISS/Coombs gel card test (Murten, Switzerland) on 14,942 patients for whom blood transfusions were ordered between July 1, 1997 and March 31, 2001. When the test for Abs was positive, Ab identification tests were further carried out with the DiaMed(TM) LISS/Coombs gel card and the ID-DiaPanel 1-11. RESULTS: Eighty-one out of 14,942 patients (0.54%) revealed positive results. Of these, 15 showed anti-E, 5 showed anti-E+c, 4 showed anti-C, 3 showed anti-D, 2 showed anti-Jk(a), 1 each showed anti-c, anti-M, anti-Lu(a), and anti-K Abs. CONCLUSIONS: Although the detection rate for the cold Abs of the LISS/Coombs gel test was low, it is considered to be highly useful because of the high detection rate for the clinically important warm Abs, the simplicity in carrying out the test, and the easy readability of test results.


Subject(s)
Humans , Antibodies , Blood Transfusion , Comprehension , Insurance , Korea , Mass Screening