Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Chinese Journal of Microbiology and Immunology ; (12): 607-614, 2016.
Article in Chinese | WPRIM | ID: wpr-498455

ABSTRACT

Objective To investigate the feasibility of using leukocytes that were filtered out by LeukoReduction System ( LRS) to replace conventional human peripheral blood leukocytes in experimental researches and to comparatively analyze the differences between them in vitro biological functions and pheno-types of T cells. Methods Mononuclear cells were isolated from LRS-separated leukocytes and whole blood sample that collected from the same person by using Ficoll. Fluorescence-activated cell sorting ( FACS) was performed to analyze the phenotypes of T cells. CD3+T cells were sorted out by using magnetic beads. The T cells that were collected by using two different ways were incubated with anti-CD3 and anti-CD28 antibodies and IL-2 in vitro for 10 days. Several assays including cell counting, FACS and cytometric beads array ( CBA) were performed to comparatively analyze the differences in biological functions and phenotypes of T cells that were isolated by different methods. Results The phenotypes of T cells isolated from LRS filter and whole blood sample were highly similar at the initial stage. The sorting rate of CD3+T cells form LRS filter reached a high level and met the requirements for experimental researches. No statistically significant differ-ences in cell count, phenotype, expression of costimulatory molecules and cytokine secretion were observed between T cells isolated from LRS filter and whole blood sample. Conclusion This study suggested that the T cells isolated from LRS filter could be used as an alternative to whole blood T cells for fundamental resear-ches since they were similar in cell vitality, phenotype and biological functions. It provided a new way to solve the problem of blood shortage in clinic and scientific research.

2.
Journal of the Korean Society for Microbiology ; : 43-52, 1999.
Article in Korean | WPRIM | ID: wpr-163011

ABSTRACT

BACKGROUND: Use of single donor apheresis platelets and concerning for the quality of apheresis platelets has been rapidly increased. Apheresis platelets depleted white blood cell(WBC) are used to prevent or to reduce febrile non-hemolytic transfusion reactions, alloimmunization and cytomegalovirus infection. We compared COBE Spectra LRS (leukoreduction system) and COBE Spectra with PALL PXL 8 in terms of the yield predictors, processing times, and WBC contamination. METHOD: Seventy-two single donors who visited Apheresis Unit(APU) in St. Mary s hospital were prospectively randomized into COBE Spectra LRS and COBE Spectra followed by PALL PXL 8 between September 1997 and October 1998. We used Coulter counting for platelet and Nageotte hemocytometer for WBC count. Data were analyzed by independent t-test. RESULTS: The mean platelet yield per unit was 3.6+ 1.0 x 10 ' with COBE spectra LRS compared to 2.9+ 1.1 X 10 with COBE Spectra(p=0.002), and the mean WBC content per unit with COBE spectra LRS was 4.1 x 104(0.4-23.5) compared to 3.7 x 104(0.43-17.9) with PALL PXL""8(p=0.0728). CONCLUSIONS: This study shows that COBE Spectra LRS has higher platelet yields than that of COBE Spectra, and similar WBC contamination compared to PALL PXL 8. Therefore, this data suggests that COBE Spectra LRS is conveient than COBE Spectra with PALL PXL 8 in clinical practice. (Korean J Blood Transfusion 10(1): 43-51, 1999)


Subject(s)
Humans , Blood Component Removal , Blood Group Incompatibility , Blood Platelets , Blood Transfusion , Cytomegalovirus Infections , Leukocytes , Prospective Studies , Tissue Donors
3.
Korean Journal of Blood Transfusion ; : 43-51, 1999.
Article in Korean | WPRIM | ID: wpr-169751

ABSTRACT

BACKGROUND: Use of single donor apheresis platelets and concerning for the quality of apheresis platelets has been rapidly increased. Apheresis platelets depleted white blood cell (WBC) are used to prevent or to reduce febrile non-hemolytic transfusion reactions, alloimmunization and cytomegalovirus infection. We compared COBE Spectra LRSTM (leukoreduction system) and COBE Spectra with PALL PXLTM8 in terms of the yield predictors, processing times, and WBC contamination. METHOD: Seventy-two single donors who visited Apheresis Unit (APU) in St. Mary's hospital were prospectively randomized into COBE Spectra LRSTM and COBE Spectra followed by PALL PXLTM8 between September 1997 and October 1998. We used Coulter counting for platelet and Nageotte hemocytometer for WBC count. Data were analyzed by independent t-test. RESULTS: The mean platelet yield per unit was 3.6 +/- 1.0X1011 with COBE spectra LRSTM compared to 2.9 +/- 1.1X1011 with COBE Spectra (p=0.002), and the mean WBC content per unit with COBE spectra LRSTM was 4.1X104 (0.4-23.5) compared to 3.7X104 (0.43-17.9) with PALL PXLTM8 (p=0.0728). CONCLUSIONS: This study shows that COBE Spectra LRSTM has higher platelet yields than that of COBE Spectra, and similar WBC contamination compared to PALL PXLTM8. Therefore, this data suggests that COBE Spectra LRSTM is conveient than COBE Spectra with PALL PXLTM8 in clinical practice.


Subject(s)
Humans , Blood Component Removal , Blood Group Incompatibility , Blood Platelets , Cytomegalovirus Infections , Leukocytes , Prospective Studies , Tissue Donors
SELECTION OF CITATIONS
SEARCH DETAIL