Results 1 - 20 de 53
Filter
1.
Journal of Laboratory Medicine and Quality Assurance ; : 121-129, 2019.
Article in Korean | WPRIM | ID: wpr-765650

ABSTRACT

The accuracy-based lipid (ABL) proficiency testing (PT) program was started in 2016 by the Korean External Quality Assessment Service to minimize the matrix effect. We analyzed 3 years of the program. We made or purchased six kinds of commutable frozen sera based on the Clinical and Laboratory Standards Institute 37A guideline and distributed it in two rounds per year from 2016 to 2018. We obtained reference values for levels of total cholesterol (TC), high-density lipoprotein cholesterol (HDLC), low-density lipoprotein cholesterol (LDLC), total glycerides, and triglycerides in each fresh frozen pool at the reference-measurement laboratories. We evaluated the average percent bias of the participating laboratories based on the National Cholesterol Education Program (NCEP) bias limit. The number of participating laboratories evaluating TC, HDLC, LDLC, total glycerides, and triglycerides increased from 164 to 223, 163 to 223, 158 to 214, 98 to 139, and 61 to 82, respectively. The average percent bias of all participating laboratories for TC, HDLC, LDLC, total glycerides, and triglycerides was +0.14%, −0.54%, +2.9%, −1.08%, and −1.32%, respectively. The average percent bias exceeded the NCEP bias limit only once or twice for TC, HDLC, and total glycerides but frequently for LDLC (eight out of 18 pools). The manufacturer-specific bias estimation report seemed useful for traceability. Although the average percent bias of participating laboratories for TC, HDLC, LDLC, total glycerides, and triglycerides was mostly within the bias limit provided by NCEP, cases of bias limit exceeding the NCEP bias limit occurred occasionally, especially for LDLC during the 3 years of the ABL PT program in Korea, suggesting that ABL PT can be used to keep maintaining traceability.


Subject(s)
Bias , Cholesterol , Education , Glycerides , Korea , Laboratory Proficiency Testing , Lipoproteins , Reference Values , Triglycerides
2.
Journal of Laboratory Medicine and Quality Assurance ; : 65-74, 2019.
Article in Korean | WPRIM | ID: wpr-765643

ABSTRACT

Herein, we report the results of the 2018 survey on the external quality assessment (EQA) scheme for the Transfusion Medicine Program (TMP) in Korea. The proficiency testing specimens were prepared at Ajou University Hospital and were sent to the participants biannually. The average accuracy rates for ten different test items on the regular survey were as follows: ABO typing, 99.5%–99.8% (N=841); RhD typing, 99.8%–100.0% (N=827); crossmatching, 89.4%–99.6% (N=708); ABO subtyping, 94.2% and 94.4% (N=53); Rh CcEe antigen testing, all 100.0% (N=51); weak D test, 80.9% (N=207) for the first trial and not graded for the second trial; antibody screening, 99.7%–100.0% (N=304); direct antiglobulin test (DAT) using a polyspecific reagent, 98.9%–100.0% (N=264); DAT using an immunoglobulin-G monospecific reagent, all 100.0% (N=66); DAT using a C3d monospecific reagent, 97.0%–100.0% (N=67); antibody identification, 98.4%–100.0% (N=127); and ABO antibody titration, 84.6%–100.0% (N=73). There were approximately 10.5% more participants in the 2018 EQA scheme than that in 2017. Excellent survey results were obtained in the 2018 EQA scheme compared with those in 2017, except for the weak D test. The 2018 EQA scheme for the TMP should be helpful for improving the quality of the participating laboratories.


Subject(s)
Coombs Test , Korea , Laboratory Proficiency Testing , Mass Screening , Quality Improvement , Thymidine Monophosphate , Transfusion Medicine
3.
Western Pacific Surveillance and Response ; : 46-49, 2019.
Article in English | WPRIM | ID: wpr-780854

ABSTRACT

@#Diphtheria is an acute infectious disease affecting the upper respiratory tract and occasionally the skin and is caused by the action of diphtheria toxin produced by Corynebacterium diphtheriae, Corynebacterium ulcerans and Corynebacterium pseudotuberculosis. Corynebacterium infections are usually difficult to control due to their epidemic patterns, the emergence of new strains, novel reservoirs and their dissemination to susceptible human and animal populations.1 Although C. diphtheriae is largely controlled through mass immunization programmes, diphtheria escalated to epidemic proportions within the Russian Federation and the former Soviet Republics in the 1990s, highlighting the potential for this disease to cause morbidity and mortality when immunization programmes are disrupted.2 A recent review of global diphtheria epidemiology, which included an analysis of cases and information about age, showed age distribu­tion shifts and found that the majority of cases occur in adoles­cents and adults.3 Shifts in age distribution, from children to adolescents and adults, were observed from countries in the Western Pacific Region such as the Lao People’s Democratic Republic,4 the Philippines3 and Viet Nam.5

4.
Journal of Laboratory Medicine and Quality Assurance ; : 1-8, 2019.
Article in Korean | WPRIM | ID: wpr-741144

ABSTRACT

Two trials were conducted with proficiency tests for complete blood cell count (CBC) and blood cell morphology as part of the 2018 Routine Hematology Program of the Korean Association of External Quality Assessment Service. Three different control samples were sent for CBC testing and two blood cell morphology pictures were posted on the laboratory website during each trial. The mean response rates of the 1,719 participating laboratories were 97.4% and 37.2% for CBC and blood cell morphology, respectively. The distribution of equipment for CBC testing was comparable to that of the previous year. The coefficient of variation (CV) ranges were determined as 3.5%–4.1%, 1.9%–2.7%, 1.4%–2.8%, 4.5%–5.3%, and 5.4%–6.9% for white blood cell counts, red blood cell counts, hemoglobin, hematocrit, and platelet counts, respectively. The concordance rate ranged from 83.0% to 97.5% in blood cell morphology tests. We observed a continuous increase in the number of participating laboratories and a trend towards a decrease in the CVs of platelet counts compared to those in 2016. Values of the other assessed parameters were similar to those of the previous year.


Subject(s)
Blood Cell Count , Blood Cells , Erythrocyte Count , Hematocrit , Hematology , Laboratory Proficiency Testing , Leukocyte Count , Platelet Count
5.
Journal of Laboratory Medicine and Quality Assurance ; : 39-46, 2019.
Article in Korean | WPRIM | ID: wpr-741139

ABSTRACT

BACKGROUND: Currently there is no external proficiency testing program for allergen-specific immunoglobulin E assays (sIgE) in Korea. The aim of this study was to evaluate the accuracy of sIgE performed in different laboratories in Korea using Polycheck Allergy Diagnostic (Biocheck GmbH, Germany) or simply ‘Polycheck’ and to further perform an inter-laboratory comparison of sIgE. METHODS: Three inter-laboratory trials were undertaken from June 2016 to December 2017 at nine institutions. Serum samples obtained from three patients who had a history of positive Polycheck results were used in each trial. A total of 59 allergens were evaluated from the standard panel, inhalation panel, and food panel. The acceptable rates (%) of classes 0–6 of the results were calculated using three different criteria, including the consensus of 80% participants of the College of American Pathologists (CAP), the most frequent value (MFV), and the Overall Misclassification Index Score (OMIS). RESULTS: The proportion of laboratories that showed acceptable results for CAP criteria, MFV, and OMIS were around 93.0%–97.7%, 66.3%–76.0%, and 0.1–1.3, respectively, in each trial. Under-performing institutes showed consistently higher (49/68, 72.1%) or lower (19/68, 27.9%) than acceptable results for all criteria. CONCLUSIONS: This is the first study evaluating the inter-laboratory variation of sIgE in Korea using various criteria. It was found that the acceptable rate could be altered based on changes in these criteria. These findings might be useful for the inter-laboratory comparison of sIgE in Korea in the future as well.


Subject(s)
Humans , Academies and Institutes , Allergens , Consensus , Hypersensitivity , Immunoglobulin E , Immunoglobulins , Inhalation , Korea , Laboratory Proficiency Testing , Mass Screening , Quality Control
6.
Journal of Laboratory Medicine and Quality Assurance ; : 178-181, 2018.
Article in Korean | WPRIM | ID: wpr-718776

ABSTRACT

As part of the clinical chemistry programs of the Korean Association of External Quality Assessment Service, we organized trials to conduct external quality assessment of hemoglobin A1c (HbA1c) in 2016 and 2017. We delivered three commutable whole blood specimens for each trial. The overall response rates were 96.4% in 2016 and 98.4% and 99.6% in the first and second trials in 2017, respectively. Two types of reports were generated: a common report including the mean, standard deviation, coefficient of variation, median, minimum value, and maximum value according to manufacturer and instrument, as well as a summary report of the results from each participating laboratory, including a histogram for each specimen, Levey-Jennings chart for serial percent deviations, and table showing the target value, upper and lower limits, percent deviation, and grade. From 2016, the acceptance criterion was changed from ±8.0% to ±6.7%. The overall acceptable rates for the survey were 91.5%, 91.4%, 94.9%, and 89.0% for the first trial in 2016 through the second trial in 2017, respectively. The requisite continual improvement in the quality of HbA1c testing can be achieved through participation in similar accuracy-based proficiency testing programs.


Subject(s)
Chemistry, Clinical , Korea , Laboratory Proficiency Testing , Research Report
7.
Journal of Laboratory Medicine and Quality Assurance ; : 188-198, 2018.
Article in Korean | WPRIM | ID: wpr-718774

ABSTRACT

In both 2016 and 2017, the cytogenetic and molecular cytogenetic programs conducted three assessments for the Korean Association of External Quality Assessment Service. A total of six cases with chromosomal aberrations were distributed in 2016, and nine cases were examined in 2017 in the chromosome surveys. For the fluorescence in situ hybridization surveys, six cases and nine cases were assessed in 2016 and 2017, respectively. A total of 38 laboratories in 2016 and 39 laboratories in 2017 participated in the cytogenetics program. In the molecular cytogenetics program, a total of 32 laboratories participated in 2016, and 31 laboratories participated in 2017. Most of the participating laboratories showed acceptable results for the cytogenetics and molecular cytogenetics programs. For the unacceptable results, there were various annotation errors, suggesting the need for continuous education and quality control.


Subject(s)
Chromosome Aberrations , Cytogenetics , Education , Fluorescence , In Situ Hybridization , Korea , Laboratory Proficiency Testing , Quality Control
8.
Journal of Laboratory Medicine and Quality Assurance ; : 199-210, 2018.
Article in Korean | WPRIM | ID: wpr-718773

ABSTRACT

Quality control for genetic analysis has become more important with a drastic increase in testing volume and clinical demands. The molecular diagnostics division of the Korean Association of Quality Assurance for Clinical Laboratory conducted two trials in 2017 on the basis of molecular diagnostics surveys, involving 53 laboratories. The molecular diagnostics surveys included 37 tests: gene rearrangement tests for leukemia (BCR-ABL1, PML-RARA, AML1-ETO, and TEL-AML1), genetic tests for Janus kinase 2, FMS-like tyrosine kinase 3-internal tandem duplication, FMS-like tyrosine kinase 3-tyrosine kinase domain, nucleophosmin, cancer-associated genes (KRAS, EGFR, KIT, and BRAF), hereditary breast and ovarian cancer genes (BRCA1 and BRCA2), Li-Fraumeni syndrome (TP53), Wilson disease (ATP7B), achondroplasia (FGFR3), hearing loss and deafness (GJB2), Avellino (TGFBI), multiple endocrine neoplasia 2 (RET), Huntington disease, spinocerebellar ataxia, spinal and bulbar muscular atrophy, mitochondrial encephalopathy with lactic acidosis and stroke-like episodes, myoclonic epilepsy ragged red fibre, Leber hereditary optic neuropathy, Prader-raderd Angelman syndrome, Duchenne muscular dystrophy, spinal muscular atrophy, fragile X syndrome, apolipoprotein E genotyping, methylenetetrahydrofolate reductase genotyping, and ABO genotyping. Molecular genetic surveys revealed excellent results for most participants. The external quality assessment program for genetic analysis in 2017 proved useful for continuous education and the evaluation of quality improvement.


Subject(s)
Achondroplasia , Acidosis, Lactic , Angelman Syndrome , Apolipoproteins , Brain Diseases , Breast , Deafness , Education , Epilepsies, Myoclonic , Fragile X Syndrome , Gene Rearrangement , Hearing Loss , Hepatolenticular Degeneration , Huntington Disease , Janus Kinase 2 , Korea , Laboratory Proficiency Testing , Leukemia , Li-Fraumeni Syndrome , Methylenetetrahydrofolate Reductase (NADPH2) , Molecular Biology , Multiple Endocrine Neoplasia , Muscular Atrophy, Spinal , Muscular Disorders, Atrophic , Muscular Dystrophy, Duchenne , Optic Atrophy, Hereditary, Leber , Ovarian Neoplasms , Pathology, Molecular , Phosphotransferases , Quality Control , Quality Improvement , Spinocerebellar Ataxias , Vascular Endothelial Growth Factor Receptor-1
9.
Chinese Journal of Preventive Medicine ; (12): 180-184, 2018.
Article in Chinese | WPRIM | ID: wpr-806145

ABSTRACT

Objective@#To analyze the results obtained from the proficiency testing program for determination of bovine blood lead and urinary cadmium, so as to evaluate the proficiency of the laboratories, and improve the detection and quality control capability of occapational health laboratory.@*Methods@#Prepared 3 levels of lead samples with bovine blood as base material, taking Technical Norm of Primary Reference Material as Operating standard, 60, 80, 180 μg/L were used as the standard concentration. All samples were made for 200 bottles. Normal urine were used to prepared 3 levels of cadmium samples with 5.0, 7.0, 10.0 μg/L as standard concentration, then 3 level of samples were made for 200 bottles respectively. Blood lead and urinary cadmium samples were sent to each laboratory in the form of sample pairs. One-way ANOVA was used to investigate the homogeneity. The results of each laboratory were statistically analyzed by robust statistical method, and the detection ability of the laboratory was evaluated by the Z ratio score method. By consulting the test reports and original records of each participating laboratory, the reasons for the unsatisfactory results were analyzed.@*Results@#The statistical F of the uniformity of blood lead 1.42, 1.37 and 2.85, F<3.13, P were 0.294, 0.314 and 0.059, respectively in 31 labs. There is no statistical significance in the difference of blood lead (P>0.05). And urine cadmium was less than the critical value (P>0.05). In all, 31 laboratories participated in the test of blood lead, and 28 loboratories paticipated in urine cadmium verification. The statistical F of the uniformity of urinary cadmium 1.90, 1.35 and 1.19, F<3.13. The homogeneity of the samples were in accordance with the requirements of proficiency testing program. The satisfactory rate of the results for blood lead was 84% (26/31) , and the satisfactory rate of urinary cadmium was 93% (26/28) . In the test of blood lead, 21 of the 31 laboratories were controlled by the standard material method. Totally, 20 of them get an satisfactory level, the rate was 95%.@*Conclusion@#Most of the laboratory test results were satisfactory, which showed that the detection capability for blood lead and urine cadmium was good. The main causes of unsatisfactory results were detection methods, tools of quality control ortraceability standards.

10.
Journal of Laboratory Medicine and Quality Assurance ; : 1-8, 2018.
Article in Korean | WPRIM | ID: wpr-713616

ABSTRACT

Under the Routine Hematology Program of the Korean Association of External Quality Assessment Service, complete blood count (CBC) and blood cell morphology proficiency tests were performed during 2017. We conducted two trials, sent three control materials for CBC testing, and posted two cell morphology pictures on the website for each trial. Of 1,646 laboratories, the mean response rates for CBC and blood cell morphology were 96.7% and 42.0%, respectively. The distribution of equipment for CBC testing was similar to that of the previous year. The coefficient of variations for white blood cell counts, red blood cell counts, hemoglobin, hematocrit, and platelet counts were 3.7%–4.7%, 2.2%–2.4%, 1.5%–3.0%, 5.4%–6.0%, and 7.2%–10.2%, respectively. More than 80% of the blood cell morphology tests were concordant among all of the trials, except for the HHI-17-03 trial. In 2017, the number of participating laboratories increased, and the performance was similar to that of the previous year.


Subject(s)
Blood Cell Count , Blood Cells , Erythrocyte Count , Hematocrit , Hematology , Korea , Laboratory Proficiency Testing , Leukocyte Count , Platelet Count
11.
Journal of Laboratory Medicine and Quality Assurance ; : 9-20, 2018.
Article in Korean | WPRIM | ID: wpr-713615

ABSTRACT

Here, we have reported results of the surveys on the external quality assessment scheme (EQA) of the Transfusion Medicine Program (TMP) in Korea that were carried out in 2017. The proficiency testing specimens were prepared at Ajou University Hospital, and sent to the participants biannually. The average accuracy rates (N=the number of participants) for ten different test items on the regular survey were as follows: ABO typing, 99.1%–99.9% (N=714); RhD typing, 99.3%–100.0% (N=695); crossmatching, 88.9%–98.5% (N=618); ABO subtyping, 80.7% and 96.0% (N=51); Rh CcEe antigen testing, 98.8%–100.0% (N=51); weak D test, 99.3% and 100.0 (N=150); antibody screening, 98.6%–100.0% (N=295); direct antiglobulin test (DAT) using a poly-specific reagent, 99.2%–100.0 (N=256); DAT using an immunoglobulin-G monospecific reagent, all 100.0% (N=68); DAT using a C3d-monospecific reagent, 83.6%–100.0% (N=72); antibody identification, 88.7%–99.2% (N=123); and ABO Ab titration, 84.6%–100.0% (N=73). The number of participants for the EQA for TMP in 2017 was much higher than that in 2016. Except for the case of ABO subtyping, excellent survey results for the 2017 EQA for TMP were obtained, compared to those in 2016. Thus, the EQA for TMP in 2017 should be helpful for improving the quality of the participating laboratories.


Subject(s)
Coombs Test , Korea , Laboratory Proficiency Testing , Mass Screening , Quality Improvement , Thymidine Monophosphate , Transfusion Medicine
12.
Chinese Journal of Laboratory Medicine ; (12): 680-684, 2018.
Article in Chinese | WPRIM | ID: wpr-712193

ABSTRACT

Objective To investigate the advantages and continuous optimization of laboratory automation system through analysis and assessment of the core data and performance after the application of open assembly line.Methods Collect the data of biochemical and immunoassay in Shuguang Hospital attached to Shanghai University of Traditional Chinese Medicine from April to October 2017.( 1 ) Cost analysis of the assembly line schemes;(2) Analysis of workflow before and after the application of assembly line;(3) Analysis of the volume of samples collecting before and after the application of assembly line ;(4) Analysis of TAT data before and after the application of assembly line; ( 5 ) Analysis of staffs allocation before and after the application of assembly line; (6) Analysis of samples rechecking before and after the application of assembly line .Results (1) Open assembly line costs least on hardware (8 million) and site among various projects;(2) Inspection process is greatly simplified after the application of assembly line;(3) The samples′volume of biochemical and immunoassay inspection were reduced by 31.85%;(4) The items′test cycle decreases after the application of assembly line , the average TAT is reduced by 32 minutes;(5) Staffs for samples pretreatment can be reduced by 50%after the application of assembly line , and the quantity of operators does not change;(6) The number of re-check samples increase except the gray zone and critical values , which ensures the reliability of the results .Conclusion To analyze the core data and to evaluate the performance , the laboratory improve on detection cycle ,staffs,and test efficiency.

13.
Journal of Laboratory Medicine and Quality Assurance ; : 77-84, 2018.
Article in Korean | WPRIM | ID: wpr-714808

ABSTRACT

In 2017, the Korean Association of External Quality Assessment Service developed a hormone proficiency testing program that comprised 11 test items for hormone I and four test items for hormone II. This program was conducted twice a year using three-level control materials. Data and results of each test item were analyzed by the respective institutions according to the test instruments. The report was prepared by dividing it into a common report that showed the characteristics of the overall participating institutions and an organization-specific report that showed the assessment data of individual institutions. The following statistical data were presented: the number of participating institutions per group, mean, standard deviation, coefficient of variation, median, minimum value, and maximum value. The individual report was composed of a table, histogram, and Levey-Jennings chart showing the statistics for each test item. The results of the assessment of each institution and the statistical data for each classification are presented in a table, and a standard deviation index was provided for both the company classification and classification by instruments. Although the total number of participating institutions and distribution of test instruments were not significantly different from the previous year, the number of participating institutions varied by test item. The coefficient of variation tended to be relatively high for each test item because the concentration of quality control materials was low and the number of participating institutions was small. I believe that these statistical analysis data are useful for analyzing external quality control results of the institutions and selecting an immunoassay test instrument for hormones.


Subject(s)
Classification , Immunoassay , Korea , Laboratory Proficiency Testing , Quality Control
14.
Journal of Laboratory Medicine and Quality Assurance ; : 85-91, 2018.
Article in Korean | WPRIM | ID: wpr-714807

ABSTRACT

In 2017, the Korean Association of External Quality Assessment Service developed a special protein proficiency testing program that consisted of nine quantitative test items. This program was conducted twice a year using three-level control materials. Data and results of each test item were analyzed by respective institutions according to the test instruments. The report was prepared by dividing it into a common report that showed the characteristics of all the participating institutions and an organization-specific report that showed the assessment data of individual institutions. The following statistical data were presented: the number of participating institutions per group, mean, standard deviation, coefficient of variation, median, minimum value, and maximum value. The individual report was composed of a table, histogram, and Levey-Jennings chart showing the statistics for each test item. The results of the assessment of each institution and the statistical data for each classification are presented in a table, and a standard deviation index for both the company classification and classification by instruments was provided. Overall, no significant difference was observed between the number of participating institutions and the distribution of test equipment. The coefficient of variation tended to be relatively high for each test item because the concentration of quality control materials was low and the number of participating institutions was small. I believe that these statistical analysis data are useful for analyzing external quality control results of the institutions and selecting an immunoassay test instrument for special protein.


Subject(s)
Classification , Immunoassay , Korea , Laboratory Proficiency Testing , Quality Control
15.
Journal of Laboratory Medicine and Quality Assurance ; : 51-69, 2018.
Article in Korean | WPRIM | ID: wpr-714781

ABSTRACT

As part of the immunoserology program of the Korean Association of External Quality Assessment Service, we organized two trials on the external quality assessment of hepatitis viral markers in 2016 and 2017. The hepatitis viral antigens and antibodies program consisted of 10 test items. We delivered two and three types of pooled sera specimens to 965 and 965 institutions for the first and second trials of external proficiency testing in 2016, respectively. The number of participating laboratories was 915 (94.8%) and 913 (95.0%) in the first and second trials in 2016, respectively. We also delivered three kinds of pooled sera specimens to 936 and 1,015 institutions for the first and second trials of external proficiency testing in 2017, respectively. The number of participating laboratories was 920 (98.3%) and 996 (98.1%) in the first and second trials in 2017, respectively. The most commonly tested items were hepatitis B surface antigen, followed by the antibodies to hepatitis B surface antigen, anti-hepatitis C virus, hepatitis B envelope antigen, antibodies to hepatitis B envelope antigen, anti-hepatitis A virus and antibodies to hepatitis B core antigen. The most frequently used methods for detecting viral markers were the chemiluminescence immunoassay and the electrochemiluminescence immunoassay, but they yielded a few-false positive results due to the matrix effect. The immunochromatographic assay yielded false-negative results for anti-hepatitis A virus due to low sensitivity. Continuous improvement in the quality of viral hepatitis testing through participation in the survey seems necessary.


Subject(s)
Antibodies , Antigens, Viral , Biomarkers , Hepatitis A , Hepatitis B , Hepatitis B Core Antigens , Hepatitis B Surface Antigens , Hepatitis B virus , Hepatitis C , Hepatitis , Immunoassay , Chromatography, Affinity , Korea , Laboratory Proficiency Testing , Luminescence
16.
Acta méd. peru ; 34(4): 309-316, oct.-dic. 2017. ilus, tab
Article in Spanish | LILACS | ID: biblio-989166

ABSTRACT

Desde la aparición de las primeras pruebas de laboratorio que diagnosticaban la infección por el virus de la inmunodeficiencia humana, hace más de treinta años, el avance tecnológico ha permitido contar con una diversidad de pruebas cada vez más sensibles y específicas, cuya adecuada interpretación en la práctica médica diaria es indispensable para el manejo terapéutico de los pacientes. El objetivo de esta revisión es difundir la apropiada comprensión interrelación de los resultados de aquellas pruebas de uso común actualmente


Since the advent of the first laboratory tests for diagnosing the human immunodeficiency virus infection more than thirty years ago, technological advances have allowed us to have more sensitive and specific tests, and their adequate interpretation in clinical practice is indispensable for proper management of patients. The purpose of this review is to describe the adequate understanding and relationships of the results of all commonly used tests

18.
Journal of Laboratory Medicine and Quality Assurance ; : 168-177, 2017.
Article in Korean | WPRIM | ID: wpr-209175

ABSTRACT

BACKGROUND: There are few commercial quality-control (QC) materials for internal QC of flow cytometric analysis, especially for leukemia/lymphoma immunophenotyping. The purpose of this study was to investigate the current QC status of flow cytometry in Korea through a questionnaire survey, and develop new QC materials using cultured cell lines for markers which QC materials are unavailable. METHODS: The current state of internal QC of flow cytometry in Korea was investigated via a questionnaire survey. Cell lines to be used as QC materials were cultured and produced as QC materials. Cell viability and the expression of markers on the cultured cell lines were tested by flow cytometry to confirm the stability of the QC materials. Simulated quality assessment results for the cultured cell line QC materials were sent to laboratories for external proficiency testing (PT). RESULTS: Seventeen medical institutions completed the questionnaire survey. Hematopoietic stem cell count (CD34) and lymphocyte subset panel items in most of these institutions were managed using commercialized QC materials. The markers that could not be managed by QC materials were CD117, MPO (myeloperoxidase), TdT (terminal deoxynucleotidyl transferase), CD20, CD10, CD64, CD79α, FMC7, cytoCD22, CD23, CD34, and CD61. Five cell lines expressing these markers were selected and sent as QC materials. PT results for most of the markers were in concordance, except those for FMC7 and CD64. CONCLUSIONS: For the QC control of flow cytometry without commercialized QC materials, cultured cell lines are useful and can be used as an alternative for management of reagents used in flow cytometric analysis.


Subject(s)
Cell Line , Cell Survival , Cells, Cultured , Flow Cytometry , Hematopoietic Stem Cells , Immunophenotyping , Indicators and Reagents , Korea , Laboratory Proficiency Testing , Lymphocyte Subsets , Quality Control
19.
Journal of Laboratory Medicine and Quality Assurance ; : 1-8, 2017.
Article in Korean | WPRIM | ID: wpr-156760

ABSTRACT

BACKGROUND: In general, internal/external quality control of special stains for diagnosis of hematological diseases may be unavailable in a clinical laboratory owing to the lack of an appropriate positive/negative control material. METHODS: We developed a protocol on positive/negative control materials for five special stains (iron, myeloperoxidase [MPO], periodic acid-Schiff [PAS], Sudan black B [SBB], and alpha-naphthyl acetate esterase [ANAE]) using a hematological malignant cell line. First, we compared stainability of seven cell lines (HL-60, THP-1, K562, Kasumi-1, KG-1, KO52, and NKM-1), then confirmed duration of stable stainability. A proficiency test using external quality control materials was conducted at eleven institutions, which participated voluntarily. RESULTS: HL-60 and THP-1 cell lines, which showed good stainability among the seven cancer cell lines, were selected as external quality control materials. The stainability of a prepared cell line fixed on control slides was stable for 3–4 weeks (MPO, SBB, and PAS) or 9–10 weeks (ANAE). The stainability of paraffin-embedded control material for iron stain was stable for 3 months. The results from 11 institutions were the same on iron, MPO, SBB, and ANAE. Nevertheless, two of 10 institutes showed discrepant results on PAS. CONCLUSIONS: In this study, we demonstrated that cell lines could serve as a standard quality control material for special stains. Most institutions showed representative results on special stains except for PAS. This protocol for special stain may be useful as an external or internal quality control in a haematology laboratory.


Subject(s)
Academies and Institutes , Cell Line , Coloring Agents , Diagnosis , Hematologic Diseases , Hematology , Iron , Laboratory Proficiency Testing , Naphthol AS D Esterase , Peroxidase , Quality Control , Sudan
20.
Journal of Laboratory Medicine and Quality Assurance ; : 107-116, 2017.
Article in Korean | WPRIM | ID: wpr-100914

ABSTRACT

We report here the 2016 results of surveys on an external quality assessment (EQA) for immunohematology testing in Korea carried out in 2016. The proficiency testing specimens were prepared at Ajou University Hospital, and the specimens were sent to participants biannually. The average accuracy rates (N=the number of participants) for ten different test items on the regular survey were as follows: ABO typing, 98.9%–99.7% (N=627); RhD typing, 98.6%–99.8% (N=607); crossmatching, 90.1%–98.1% (N=454); ABO subtyping, 92.7%–93.0% (N=42); Rh CcEe antigen testing, 97.8%–100.0% (N=46); weak D test, 70.8%–73.6% (N=91); antibody screening, 96.6%–100.0% (N=267); direct antiglobulin test (DAT) using a polyspecific reagent, 92.2%–99.6% (N=49); DAT using an immunoglobulin G monospecific reagent, 84.1%–100.0% (N=68); DAT using a C3d monospecific reagent, 80.0%–100.0% (N=68); antibody identification, 96.7%–99.1% (N=118); and ABO antibody titration, 82.4%–100.0% (N=42). Excellent results for the 2016 EQA for immunohematology testing were obtained, except for those of the weak D test. The EQA for immunohematology testing in 2016 should be helpful for improving the quality of participating laboratories.


Subject(s)
Coombs Test , Immunoglobulin G , Korea , Laboratory Proficiency Testing , Mass Screening , Transfusion Medicine
SELECTION OF CITATIONS