Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.030
Filter
1.
Acta Medica Philippina ; : 63-68, 2024.
Article in English | WPRIM | ID: wpr-1006817

ABSTRACT

Background@#Surgical correction of aphakia without capsular support continues to be a challenge. Improvements in the technology of cataract surgery have provided advancements in techniques in surgical management of aphakia. Locally, we have limited data on the outcomes of the different intraocular lenses used in aphakia.@*Objective@#This study aimed to determine visual outcomes and complications associated with different techniques of intraocular lens implantation in the absence of capsular support.@*Methods@#We reviewed the medical charts of 207 patients who underwent intraocular lens implantation without capsular support. Excluded were patients with incomplete follow up, pediatric patients, and lost records. Best corrected visual acuity at day 1, 1st month, 3rd month and 6th month postoperatively, and the complications were noted.@*Results@#Mean age was 60 and 51% (n=105) were females. The mean follow-up time was 9.33 ± 0.71 months. Loss of capsular support was most frequently caused by intraoperative complication (n=146, 70%) and trauma. Retropupillary fixation iris claw intraocular lens was frequently used (n=93, 44.9%). Across all patients, visual acuities showed excellent outcomes with 20/50 or better. Across IOL types, the most frequent postoperative complication was increase in IOP. Statistically significant results were set at P <0.05. @*Conclusion@#There is a notable preference towards iris claw retropupillary lenses through time. Iris claw lenses showed the shortest operative time. All intraocular lenses used in aphakia showed comparably good postoperative visual acuities, except for the superior visual acuity trend seen among retropupillary iris claw and anterior chamber IOL groups. Complications included elevated intraocular pressures, corneal edema, and pigment dispersion.


Subject(s)
Aphakia , Philippines
2.
Acta Medica Philippina ; : 1-6, 2024.
Article in English | WPRIM | ID: wpr-1006604

ABSTRACT

Objective@#Toric intraocular lens implantation has been used to correct corneal astigmatism during cataract surgery. The study aimed to compare the visual outcomes between manual vs markerless toric intraocular lens implantation in astigmatic correction.@*Methods@#The medical records of patients at American Eye Center who underwent phacoemulsification by multiple surgeons with insertion of monofocal or multifocal toric lenses via manual marking and markerless method from 2010-2019 were reviewed.@*Results@#A total of 70 patients were included in the study. Results showed no significant difference in the following characteristics between manual and markerless method at one month and two months post-cataract surgery: uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near vision acuity (UNVA), corrected near vision acuity (CNVA), refraction spherical equivalent. The UDVA, CDVA, UNVA, CNVA and astigmatism had significantly lower median/mean-rank at one and two months postoperatively compared to preoperative values.@*Conclusion@#In conclusion, our findings indicated that both manual-based and markerless systems effectively facilitated accurate placement of the toric IOL on the desired axis. Notably, there was no significant difference observed between the two methods. Both systems are straightforward to execute. In low-resource settings like the Philippines, the manual marking method can be employed when markerless guidance equipment is unavailable.


Subject(s)
Phacoemulsification , Astigmatism , Philippines
3.
International Eye Science ; (12): 315-319, 2024.
Article in Chinese | WPRIM | ID: wpr-1005402

ABSTRACT

AIM: To observe the effectiveness, safety and ethnic differences of 0.005% atropine eye drops combined with orthokeratology in controlling adolescents' low myopia between different ethnic groups.METHODS:A total of 246 Han and Hani patients(246 eyes)with low myopia treated in our hospital from January to October 2021 were selected, with 120 patients(120 eyes)treated with 0.005% atropine eye drops combined with orthokeratology in experimental group, and 126 patients(126 eyes)treated with orthokeratology in control group. The uncorrected visual acuity, spherical equivalent(SE), axial length(AL), intraocular pressure, tear film break-up time(BUT), corneal curvature and corneal thickness of the two groups before and 1 a after wearing lenses were observed, and the incidence of complications were recorded.RESULTS:At 1 a after wearing lenses, the changes of AL and SE in the experimental group(0.16±0.35 mm, -0.39±0.47 D)were lower than those in the control group(0.22±0.89 mm, -0.48±0.54 D), uncorrected visual acuity(LogMAR)was better than the control group(0.11±0.25 vs 0.14±0.19; P&#x0026;#x003C;0.05), there were differences in BUT, anterior chamber depth, corneal curvature and corneal thickness(P&#x0026;#x003C;0.05), but there were no differences in intraocular pressure of the two groups(P&#x0026;#x003E;0.05). In the Han and Hani groups, there were no differences in the changes of uncorrected visual acuity, AL and SE(P&#x0026;#x003E;0.05). During the follow-up period, no significant local or systemic adverse reactions occurred in the two groups, and there was no difference in the incidence of ocular complications between the two groups of patients(P&#x0026;#x003E;0.05).CONCLUSION: The 0.005% atropine eye drops combined with orthokeratology can effectively delay the progression of low myopia in adolescents without significant adverse reactions and ethnic differences.

4.
International Eye Science ; (12): 260-263, 2024.
Article in Chinese | WPRIM | ID: wpr-1005392

ABSTRACT

With the rapid development of science and technology and the wide application of electronic products, the number of patients with high myopia is gradually increasing. Meanwhile, owing to the continuous optimization of surgical skils and the continuous advancement in materials of posterior chamber intraocular lens and manufacturing processes, implantable collamer lens(ICL)V4c implantation has gradually become one of the main surgeries for the treatment of high myopia. In the rapid era of social information, people pay more attention to the long-term efficacy after ICL V4c implantation, they not only want clear vision, but also the pursuit of visual comfort and durability. Therefore, this paper will specifically discuss the research progress of the post-implantation efficacy of ICL V4c with at least 2 a of follow-up observation within 3 a, aiming to review the latest research progress on the long-term efficacy of ICL V4c implantation from the three dimensions of visual quality, safety, efficacy and stability and possible surgical complications after ICL V4c implantation.

5.
International Eye Science ; (12): 210-215, 2024.
Article in Chinese | WPRIM | ID: wpr-1005382

ABSTRACT

AIM: To compare the clinical efficacy, vault, and rotational stability of horizontal, oblique, and vertical implantation of Toric implantable collamer lens(TICL).METHODS: Retrospective cohort study. A total of 92 cases(120 eyes)who underwent TICL implantation from July 2018 to March 2022 and had regular follow-up for at least 1 a postoperatively(1 d, 1 wk, 1, 3, 6 mo, and 1 a)at Wuhan Bright Eye Hospital were collected. The patients were divided into three groups, with 34 cases(45 eyes)in horizontal implantation group, 25 cases(29 eyes)in oblique implantation group(29 cases), and 33 cases(46 eyes)in vertical implantation group. Uncorrected distance visual acuity(UDVA), corrected distance visual acuity(CDVA), diopters, vault, and rotation angle(deviation of the actual axis of TICL from the expected axis).RESULTS: All surgeries were uneventful, and there were no complications such as infection, secondary glaucoma, or cataract opacity. Safety and efficacy of the surgery: the CDVA of the three groups of patients was better than or equal to the preoperative CDVA at 1 a postoperatively, and there was no statistically significant differences in postoperative UDVA and CDVA of the three groups(P&#x0026;#x003E;0.05). The safety index at 1a postoperatively was 1.34±0.21, 1.34±0.17, and 1.31±0.18 for the horizontal, oblique, and vertical groups, respectively. The efficacy index was 1.26±0.21, 1.33±0.18, and 1.27±0.16 for the three groups, respectively, both with no statistically significant differences(P&#x0026;#x003E;0.05). Vault: there was a significant difference in postoperative vault among the three groups(P=0.003), with the vertical group having the lowest vault, followed by the horizontal group and the oblique group. The vaults at different follow-up time points within each group showed significant differences(P&#x0026;#x003C;0.001), and all decreased over time. Residual astigmatism: there was no significant difference in residual astigmatism among the three groups(P=0.130), but there were differences at different follow-up time points within each group(P&#x0026;#x003C;0.001). Rotation angle: no significant differences in rotation angle were observed among the three groups(P=0.135), but there were differences at different follow-up time points within each group(P&#x0026;#x003C;0.001).CONCLUSION: The implantation of TICL in different orientations has good safety and efficacy, the postoperative rotational stability is good, and the appropriate angle can be selected to implant TICL according to the clinical situation.

6.
International Eye Science ; (12): 106-110, 2024.
Article in Chinese | WPRIM | ID: wpr-1003516

ABSTRACT

AIM: To compare the short-term postoperative visual acuity, visual disturbance phenomena, and spectacle independence rate in patients who underwent monocular implantation with trifocal, multifocal, or extended range of vision intraocular lens(IOL).METHODS: A retrospective analysis was conducted on 67 cataract patients(67 eyes)who underwent phacoemulsification cataract extraction combined with IOL implantation from March 2019 to December 2022. A total of 35 cases(35 eyes)received Symfony extended range of vision IOL implantation, 21 cases(21 eyes)received AcrySof IQ ReSTOR +3D multifocal IOL, and 11 cases(11 eyes)received AcrySof IQ PanOptix trifocal IOL. The preoperative uncorrected distance visual acuity(UDVA), uncorrected intermediate visual acuity(UIVA), and uncorrected near visual acuity(UNVA)and 3 mo postoperatively were documented. Moreover, defocus curves, visual disturbance phenomena, and spectacle independence rates were recorded at 3 mo postoperatively.RESULTS: At 3 mo postoperatively, no statistically significant differences were observed in UDVA among the three groups(P&#x0026;#x003E;0.05). A comparison of UIVA showed superior results in the Symfony and PanOptix groups compared to the ReSTOR group(all P&#x0026;#x003C;0.01). The UNVA of both the ReSTOR and PanOptix groups outperformed the Symfony group(all P&#x0026;#x003C;0.01). The defocus curves indicated that in the intermediate vision range(-1.00 to -1.50 D), the Symfony group exhibited better performance than the ReSTOR group(P&#x0026;#x003C;0.05); while in the near vision range(-2.50 to -3.50 D), the ReSTOR group was superior to the Symfony group(P&#x0026;#x003C;0.05). The PanOptix group demonstrated superior visual acuity in the near vision range(-2.00 to -3.50 D)compared to the Symfony group(P&#x0026;#x003C;0.05)and was also superior in the intermediate vision range(-1.00 to -2.00 D)compared to the ReSTOR group(P&#x0026;#x003C;0.05). No significant differences were observed in the incidence of glare or halo and binocular interference phenomena among the three groups(P&#x0026;#x003E;0.05). The PanOptix and ReSTOR groups exhibited a higher spectacle independence rate compared to the Symfony group(P&#x0026;#x003C;0.0167).CONCLUSION: Compared to Symfony extended range of vision IOL and ReSTOR multifocal IOL, PanOptix trifocal IOL offers a balanced approach to distance, intermediate, and near visual acuity, without a high incidence of glare and halo, and with a higher spectacle independence rate. Caution is still advised when considering monocular implantation with presbyopia-correcting IOLs.

7.
International Eye Science ; (12): 93-96, 2024.
Article in Chinese | WPRIM | ID: wpr-1003513

ABSTRACT

With the wide application of phacoemulsification and intraocular lens implantation, many cataract patients have effectively recovered vision. Postoperative intraocular lens opacification is an important indicator for evaluating biocompatibility, as it affects the visual quality of patients. The manifestation and risk factors of opacification vary among different materials used for intraocular lenses. However, better visual quality after surgery is not determined by a single factor. The material of the intraocular lens and the patient's response to the intraocular lens are all factors that affect the postoperative visual quality. With the continuous advancement of technology, an increasing number of new materials are being applied in the field of intraocular lenses. Fully understanding the characteristics of intraocular lens materials, selecting suitable intraocular lens for patients and reducing complications caused by materials will be beneficial to patients. The characteristics of different intraocular lens materials and the risk factors of opacification after intraocular lens implantation were discussed in this paper.

8.
International Eye Science ; (12): 88-92, 2024.
Article in Chinese | WPRIM | ID: wpr-1003512

ABSTRACT

As a highly prevalent global condition, myopia significantly impacts the ocular health of young individuals in China. Orthokeratology lens, as a rigid corneal contact lens, has demonstrated effective control over the progression of myopia; however, its mechanism of action remains incompletely elucidated. As one of the factors influencing visual acuity, higher-order aberrations will undergo marked changes after orthokeratology, with particular emphasis on the alterations in spherical aberrations and coma. The changes in corneal morphology induced by orthokeratology lead to significant positive increase in both spherical aberration and coma. Furthermore, the elevation of spherical aberration and coma demonstrates a negative correlation with the rate of axial length growth following orthokeratology. The interplay among spherical aberration, coma, defocus, accommodation, astigmatism, and pseudo-accommodation may constitute the underlying mechanism governing the control of myopia through orthokeratology.

9.
International Eye Science ; (12): 82-87, 2024.
Article in Chinese | WPRIM | ID: wpr-1003511

ABSTRACT

Keratoconus is a progressive blinding eye disease that characterized by corneal thinning and protrusion, which accompanied with irregular astigmatism and impaired visual acuity.The irregular astigmatism of early keratoconus can be corrected by spectacles. For the irregular astigmatism of moderate to severe keratoconus, spectacles are no longer suitable, and contact lenses are the best choice for patients to restore vision. There are various types of contact lenses, making the selection very difficult. In addition, trying on lenses for a long time will increase the discomfort and overall feeling of patients, and greatly increase the workload of doctors. Thus, the article aims to summarize and discuss the classification of contact lenses, the application of contact lenses in different types of keratoconus, the complications of contact lens, and the current status and prospect of contact lenses, with a view to understanding the management and clinical application of contact lenses in keratoconus patients and to further improving the application value of contact lenses in keratoconus.

10.
International Eye Science ; (12): 77-81, 2024.
Article in Chinese | WPRIM | ID: wpr-1003510

ABSTRACT

Alzheimer's disease(AD)is a common degenerative disease of the central nervous system in which neuropathological changes precede cognitive dysfunction and behavioral impairment. Currently, early diagnosis of AD is based on invasive and expensive testing techniques that are difficult to use widely in the clinical setting. Therefore, there is an urgent need for new markers to detect AD at an early stage. The eye, as an extension of the brain, has been found to show earlier onset of ocular pathologic changes in patients with AD compared to brain pathologic changes, such as retinal structural abnormalities, visual dysfunction, retinal abnormal protein accumulation, choroidal thickness changes, decreased corneal nerve fiber density, deposition of abnormal Aβ proteins in the lens, and pupillary light decreased sensitivity of response, etc. This article reviews the ocular pathologic changes in AD patients in recent years to provide new ideas for the early clinical diagnosis of AD.

11.
International Eye Science ; (12): 641-645, 2024.
Article in Chinese | WPRIM | ID: wpr-1012836

ABSTRACT

AIM: To evaluate the accuracy of the formulas, including Haigis, SRK/T, Holladay 1, and Holladay 2, in predicting the diopter of the intraocular lens implanted in high myopia cataract patients.METHODS: Prospective study. A total of 168 cases(168 eyes)of age-related cataract with an axial length(AL)≥26 mm who were treated in our hospital from August 2017 to November 2021 were selected. According to the preoperative AL measured by IOL Master 700, the patients were divided into five groups, including 37 cases(37 eyes)in group A with 26 mm≤AL&#x003C;27 mm, 34 cases(34 eyes)in group B with 27 mm≤AL&#x003C;28 mm, 42 cases(42 eyes)in group C with 28 mm≤AL&#x003C;29 mm, 28 cases(28 eyes)in group D with 29 mm≤AL&#x003C;30 mm, and 27 patients(27 eyes)in group E with AL ≥ 30 mm. Subjective refraction was performed at 3 mo postoperatively, and the mean numerical error(MNE)and mean absolute error(MAE)of each formula for predicting diopters were calculated.RESULTS: The MNE and MAE of the Haigis and Holladay 2 formulas were relatively less in each group, and MNE and MAE did not significantly increase with the growth of the axial length. However, the MAE and MNE of the SRK/T and Holladay 1 formulas significantly increased with the growth of the axial length, with the MNE and MAE of the Holladay 1 formula increasing more significantly in groups C, D, and E.CONCLUSION: For patients with age-related cataract, with an axial length of ≥26 mm, the accuracy of predicting the diopter of the intraocular lens using the Haigis and Holladay 2 formulas were higher.

12.
International Eye Science ; (12): 634-640, 2024.
Article in Chinese | WPRIM | ID: wpr-1012835

ABSTRACT

AIM: To evaluate the binocular visual function in high myopia patients after the implantation of implantable collamer lens(ICL)V4c.METHODS: A total of 35 cases(70 eyes)that received binocular ICL implantation at our hospital from May 2019 to May 2021 were enrolled in this prospective study. Binocular full-range visual acuity, contrast sensitivity, stereopsis, mesopic vision and glare sensitivity, and monocular wavefront and the quality of vision questionnaire were assessed before the surgery and at 1 mo postoperatively.RESULTS: At 1 mo postoperatively, 35 cases(100%)had binocular uncorrected distance visual acuity(UDVA)≤0.00(LogMAR), 16 cases(46%)had binocular UDVA≥preoperative corrected distance visual acuity(CDVA). Binocular UDVA and uncorrected intermediate visual acuity(UIVA,80 cm)were improved compared to preoperative CDVA and distance-corrected intermediate visual acuity(DCIVA,80 cm)(all P&#x003C;0.05).While there were no differences in the binocular postoperative UIVA(60 cm)and preoperative DCIVA(60 cm),and uncorrected near visual acuity(UNVA,40 cm)and preoperative distance-corrected near visual acuity(DCNVA,40 cm)(all P&#x003E;0.05). The binocular contrast sensitivity was significantly improved postoperatively(P=0.001), and the postoperative binocular mesopic vision, glare sensitivity(no glare/glare)and binocular stereopsis(5 m/40 cm)had no differences(all P&#x003E;0.05). The postoperative total higher-order aberration, trefoil aberration, coma and spherical aberration were increased, besides the median of total coma in the right eye with a pupil diameter of 3.0 mm was decreased after surgery. The mean total score of quality of vision questionnaire was significantly increased from 54.87 preoperatively to 80.92 after implantation(P&#x003C;0.05), with high satisfaction and no obvious visual disturbance in patients.CONCLUSION: Although the monocular high-order aberrations increased in the early stage after ICL V4c binocular implantation in patients with high myopia, the binocular visual function was improved.

13.
International Eye Science ; (12): 612-617, 2024.
Article in Chinese | WPRIM | ID: wpr-1012831

ABSTRACT

AIM:To compare the differences, correlations and consistency of IOL Master 700 or Lenstar LS900 in preoperative ocular biometry and the accuracy of intraocular lens(IOL)degree calculation of cataract patients with high myopia.METHODS: Retrospective study. A total of 136 cases(136 eyes)of high myopia and cataract patients who underwent phacoemulsification at the ophthalmology department of Army Medical Center of PLA from March 2021 to March 2023 were collected, with a mean age of 57.38±8.08 years. Patients were divided into 3 groups based on axial length(AL): 41 eyes in group A(26 mm≤ AL ≤28 mm), 43 eyes in group B(28 mm&#x003C; AL ≤30 mm)and 52 eyes in group C(AL &#x003E;30 mm). AL, mean keratometry(Km), anterior chamber depth(ACD), lens thickness(LT)and white-to-white(WTW)were preoperatively measured by two instruments, respectively. Barrett Universal II formula was used to calculate the IOL degrees of all patients, the appropriate reserved diopter was decided individually, and the prediction error(PE)and absolute error(AE)of the two instruments were compared.RESULTS:The AL and ACD of patients in the three groups measured by Lenstar LS900 were higher than the AL measurd by IOL Master 700(all P&#x003C;0.05), with a difference of AL measured by the two devices: group C&#x003E;group B&#x003E;group A. However, there was no statistical significance in LT, Km, and WTW measured by the two instruments(all P&#x003E;0.05). All biometric parameters measured by the two devices were positively correlated(all r&#x003E;0.9, P&#x003C;0.05), and consistent(95% LoA of all groups were narrow). There was no statistically significant difference in AE calculated by the two devices(P&#x003E;0.05), but the IOL Master 700 calculated a smaller PE than Lenstar LS900(P&#x003C;0.05), with lower percentage of hyperopic shift in IOL Master 700.CONCLUSION:In cataract patients with high myopia, AL measured by Lenstar LS900 is longer than that by IOL Master 700, and the differences of AL increase along with the growth of AL. Both devices have a good prediction for IOL calculation, but IOL Master 700 has less refractive error, lower percentage of hyperopic shift, and greater clinical advantages IOL Master 700.

14.
International Eye Science ; (12): 545-550, 2024.
Article in Chinese | WPRIM | ID: wpr-1012818

ABSTRACT

In recent years, the combined surgery of phacoemulsification, intraocular lens implantation, and goniosychialysis has gradually emerged as a primary and effective approach in treating primary angle-closure glaucoma with cataracts. However, with the continuous progress of medical technology, postoperative intraocular pressure control is no longer the sole pursuit. Patients increasingly aspire to achieve higher postoperative visual quality. In order to ensure that patients attain a better refractive status and higher visual quality postoperatively, it is essential to minimize the negative impact caused by primary angle-closure glaucoma. This involves personalized selection of different intraocular lenses or calculation formulas,etc. Evaluation metrics for visual quality encompass visual acuity, contrast sensitivity, higher-order aberrations, subjective perception, etc. Therefore, this paper provides a comprehensive review of postoperative refractive shift, higher-order aberrations, contrast sensitivity and their influencing factors, and the selection of intraocular lenses for patients undergoing combined surgery for primary angle-closure glaucoma with cataracts.

15.
International Eye Science ; (12): 491-494, 2024.
Article in Chinese | WPRIM | ID: wpr-1011407

ABSTRACT

AIM: To study the early outcomes of anterior segment parameters after implantation of an implantable collamer lens with a central hole(ICL V4c)in patients with high myopia.METHODS:A total of 82 cases(160 eyes)with high myopia, including 42 males(82 eyes)and 40 females(78 eyes), aged 26.0±4.6(21 to 37)years, who underwent ICL V4c implantation at our institution from February 2019 to September 2022 and were followed up for 1 a, were included. The general characteristics of the anterior segment of the eye were measured preoperatively: spherical equivalent, mean horizontal corneal curvature, white-to-white(WTW), and axial length(AL); intraocular pressure(IOP), endothelial cell density(ECD), central anterior chamber depth(CACD), anterior chamber volume(ACV)and anterior chamber angle(ACA)were measured preoperatively and at 1 d, 1 wk, 1, 3 and 6 mo postoperatively. Furthermore, the distance from the centre of the posterior surface of the ICL V4c optical zone to the anterior surface of the lens(vault)was measured at 1 d, 1 wk, 1, 6 mo, and 1 a after surgery.RESULTS: The mean preoperative spherical equivalent of the patients was -7.56±2.55 D, mean horizontal corneal curvature was 42.89±1.47 D, WTW was 11.64±0.37 mm, and AL was 26.64±0.93 mm. The baseline IOP was 15.97±2.13 mmHg, and the differences in IOP at each time point after ICL V4c implantation compared to preoperative were not statistically significant(F=0.875, P=0.504); ECD was 2 989.30±140.78 cells/mm2 at baseline, and ECD at 6 mo after ICL V4c implantation was not statistically significant compared with preoperative ECD(t=1.475, P=0.142); CACD was 3.19±0.21 mm at baseline, and ACV was 210.30±27.7 mm3, and CACD and ACV were significantly lower than preoperative at all postoperative time points(F=111.10, 288.38, all P&#x003C;0.001). The baseline ACA was 35.44°±11.27°, and the ACA at each time point after ICL V4c implantation was significantly lower than preoperatively(F=21.23, P&#x003C;0.001). The vault was 665.32±184.03 μm at 1 d postoperatively, and continued to be significantly reduced at 1 wk, 1, 6 mo, and 1 a postoperatively compared with 1 d(F=52.10, P&#x003C;0.001). However, it remained stable at 6 mo and 1 a postoperatively, and the difference was not statistically significant compared with vault at 1 mo postoperatively(P&#x003E;0.05).CONCLUSION: ICL V4c has certain safety and efficiency in 1 a postoperative follow-up, and the parameters of the anterior segment of the eye stabilized in the early period.

16.
International Eye Science ; (12): 484-490, 2024.
Article in Chinese | WPRIM | ID: wpr-1011406

ABSTRACT

AIM: To evaluate the clinical effect of toric implantable collamer lens(TICL)V4c for correcting moderate to high myopia with high astigmatism using vector analysis and quality of life impact of refractive correction(QIRC).METHODS: Retrospective case series. A total of 55 patients(90 eyes)with moderate to high myopia and high astigmatism who received TICL V4c implantation in the refraction surgery center of ophthalmology department in our hospital from January 2019 to December 2022 were collected. Followed-up for 1 a, the uncorrected distance visual acuity(UDVA), best corrected visual acuity(BCVA)and diopters were observed. Alpins vector analysis was used to evaluate the effect of astigmatism correction, and QIRC scale was used to evaluate patients' quality of life.RESULTS: At 1 a postoperatively, the UDVA of 98% eyes was the same or better than pre-operative BCVA, the safety index was 1.11±0.14, and the efficacy index was 1.11±0.15. The angle of error of 97% of the astigmatic eyes was within ±15°. The results of vector analysis showed that correction index was 0.83±0.13, angle of error was 1.00±4.49°, and index of success was 0.21±0.15. The total higher order aberrations under a pupil diameter of 6 mm was significantly increased compared with preoperatively(P&#x003C;0.05), the QIRC score was significantly better than that before surgery(P&#x003C;0.001), and the increase of total QIRC scores was positively correlated with preoperative spherical equivalent(rs=0.215, P&#x003C;0.05), indicating that the higher degree of myopia before surgery the patients, the better the quality of life after TICL implantation.CONCLUSION: TICL V4c implantation for the correction of moderate to high myopia with high astigmatism is safe and effective, and the patients' quality of life significantly improved after surgery.

17.
International Eye Science ; (12): 469-472, 2024.
Article in Chinese | WPRIM | ID: wpr-1011403

ABSTRACT

AIM: To observe the clinical efficacy of 8-0 polypropylene scleral-sutured fixed intraocular lens(IOL)suspension implantation with the double knots technique in aphakic eyes.METHODS: Retrospective case series study. The data of 30 aphakic cases(31 eyes, 22 males)that underwent IOL suspension in our hospital from January 2021 to November 2022 were collected. The suspension of IOL(AcrySof IQ or Tecnis ZCB00)was performed by 8-0 polypropylene scleral-sutured with the double knots technique. The visual acuity, intraocular pressure(IOP), IOL position and complications with at least 6 mo of follow-up were observed.RESULTS: The mean preoperative uncorrected visual acuity(UCVA, LogMAR)and best-corrected visual acuity(BCVA, LogMAR)were 2.53±0.78 and 0.35±0.26, respectively, which were 0.58±0.26 and 0.36±0.27 at 6 mo postoperatively, respectively. And the differences in UCVA were statistically significant(t=15.408, P&#x003C;0.01), whereas the difference in BCVA was not(t=-1.677, P=0.104). There were no intraoperative complications, with IOL position all centered, but 3 eyes had IOL tilt, 2 eyes had intraocular hypertension, 5 eyes had corneal edema, and 1 eye had suture exposure postoperatively. There were no complications such as hyphema, vitreous hemorrhage, macular edema, corneal endothelial decompensation, hypotony, choroidal detachment, retinal detachment, fulminant superior choroidal hemorrhage, endophthalmitis, or others.CONCLUSION: The 8-0 polypropylene scleral-sutured fixed intraocular lens suspension implantation with the double knots technique can improve the postoperative visual acuity of aphakic patients, and fewer complications, which is an option for the treatment of aphakia, dislocation of the lens and ligament abnormalities.

18.
International Eye Science ; (12): 463-468, 2024.
Article in Chinese | WPRIM | ID: wpr-1011402

ABSTRACT

AIM: To evaluate the convenience and accuracy of a novel smartphone-assisted “any-point two-step method” for finding the target axial position in cataract phacoemulsification combined with intraocular lens(IOL)implantation.METHODS: Prospective observational study. A total of 62 cases(62 eyes)of patients with age-related cataracts who underwent cataract phacoemulsification combined with IOL implantation in our hospital from October 2021 to April 2022 were selected. They were randomly divided into two groups: 31 cases(31 eyes)in the control group were applied with the “traditional two-step method” using slit lamp to mark the target axial position of the IOL, and 31 cases(31 eyes)in the experimental group were applied with the smartphone-assisted “two-step method” to mark the target axial position of the IOL. The Callisto eye navigation system was used as a standard reference, and the deviation of the reference marking point(deviation-1), the deviation of the target axial marking point(deviation-total), and the deviation of the angle from the reference marking point to the target axial marking point(deviation-2)were calculated and recorded as the preoperative axial marking time.RESULTS:Both deviation-1 and deviation-total values were lower in the experimental group than those in the control group(1.06°±1.39° vs 2.48°±2.23°, 1.77°±1.54° vs 2.81°±1.58°, all P&#x003C;0.01), but there was no significant difference in the deviation-2 values between the two groups(1.35°±1.40° vs 1.48°±1.79°, P&#x003E;0.05). The preoperative axial marking took shorter time in the experimental group than in the control group(1.77±1.70 min vs 2.88±3.20 min, P&#x003C;0.01).CONCLUSION: The smartphone-assisted “any-point two-step method” for finding the target axial position in cataract phacoemulsification combined with IOL implantation is simple, time-saving, and accurate compared with the “traditional two-step method”.

19.
International Eye Science ; (12): 441-447, 2024.
Article in Chinese | WPRIM | ID: wpr-1011398

ABSTRACT

AIM: To observe and analyze the effectiveness and safety of wearing corneal refractive therapy(CRT)and vision shaping treatment(VST)designed orthokeratology in controlling myopic progression in adolescents with low E-value corneal morphology.METHODS: This prospective study involved 100 cases(100 eyes)of adolescent myopia patients fitted with orthokeratology at our optometry clinic from January 2020 to December 2021. The data of right eye were collected for research, and they were divided into low myopia group(-1.00 to -3.00 D)and moderate myopia group(-3.25 to -5.00 D)according to spherical equivalent, with 50 cases in each group. Each group of patients was further randomly divided into the CRT group and the VST group, with 25 cases in each group. Uncorrected visual acuity, refractive error, axial length(AL), tear film break-up time(BUT), corneal endothelial cell density, corneal staining grading, lens decentration, and refractive power at 15°-30° were measured before and after wearing orthokeratology, with a follow-up duration of 1.5 a.RESULTS: The uncorrected visual acuity of CRT and VST subgroups in the low myopia group showed no statistical significance at any time point after wearing orthokeratology. However, in the moderate myopia group, CRT subgroup showed better uncorrected visual acuity than the VST subgroup, with significant differences at 1 d and 1 wk(t=-9.474, -12.067, both P&#x003C;0.01); no significant differences were noted at other time points. After wearing lens for 6 mo and 1.5 a, the AL growth for the CRT subgroup in low and moderate myopia was less than the VST subgroup, with no statistically significant differences. There were no statistically significant differences in binocular BUT and corneal endothelial cell density after wearing lens for 6 mo and 1.5 a. Corneal injury was lower in the CRT subgroup than that in the VST subgroup, but the difference was not statistically significant(Z=-1.803, P=0.071). Lens decentration was significantly better in the CRT subgroup than in the VST subgroup(Z=-4.629, P&#x003C;0.001). In the periphery of the retina at 15°-30°, there were no significant differences in the amount of myopic defocus between the two groups, while it was statistically significant at 1, 3, and 6 mo in the moderate myopia subgroup(t=-3.949, P=0.008; t=-5.833, P&#x003C;0.001; t=-6.231, P&#x003C;0.001), indicating that CRT subgroup could produce a greater amount of myopic defocus.CONCLUSION: For patients with low E-value corneal morphology, CRT, using the vector height at 8 mm on the cornea for fitting, is not limited to the corneal E-value. It shapes faster and improves uncorrected visual acuity after shaping, especially for moderate myopia, achieving better daytime vision. In terms of controlling myopia, CRT fitting elevates return zone depth(RZD), creating a small central optical zone to produce more peripheral myopic defocus. However, there was no significant difference between the two groups in controlling AL growth. Both groups showed minimal corneal damage, indicating consistent safety in myopia control.

20.
International Eye Science ; (12): 436-440, 2024.
Article in Chinese | WPRIM | ID: wpr-1011397

ABSTRACT

AIM: To explore the effects of femtosecond laser-assisted cataract surgery combined with intraocular lens implantation(FLACS-IOL)on postoperative deviation rate of multifocal intraocular lens(MIOL)and visual quality in cataract patients.METHODS: In the prospective study, 95 patients with cataract(108 eyes)who underwent MIOL implantation in the hospital between January 2021 and December 2022 were enrolled. According to different surgical methods, they were divided into FLACS group(51 cases, 56 eyes)and Phaco group(44 cases, 52 eyes). The operation time, incision diameter of anterior capsule, effective phaco time(EPT), cumulative dissipated energy(CDE), uncorrected distance visual acuity(UCDVA), best corrected distance visual acuity(BCDVA), eccentricity distance of IOL and deviation rate at 3 mo after surgery, total high order aberration(HOA), Trefoil and coma under 3 mm pupil were compared between the two groups.RESULTS: The operation time in the FLACS group was significantly shorter than that in the Phaco group, EPT and CDE were significantly lower than those in the Phaco group(all P&#x003C;0.05). There was no significant difference in incision diameter of anterior capsule between the two groups(P&#x003E;0.05). At 1 wk, 3 mo after surgery, UCDVA in the FLACS group was better than that in the Phaco group(all P&#x003C;0.05). There were significant difference in UCDVA at 1 wk, 3 mo after surgery or BCDVA at 3 mo after surgery between the two groups(P&#x003C;0.05). At 3 mo after surgery, eccentricity distance of IOL in the FLACS group was shorter than that in the Phaco group, and deviation rate was significantly lower than that in the Phaco group(all P&#x003C;0.05). Under pupil diameter of 3 mm, HOA, trefoil and coma of whole eyes were decreased in both groups at 3 mo after surgery(P&#x003C;0.05). At 3 mo after surgery, there were significant differences in HOA and trefoil of whole eyes between the FLACS group and Phaco group(P&#x003C;0.05), but there was no significant difference in coma at 3 mo after surgery(P&#x003E;0.05).CONCLUSION: FLACS-IOL can effectively reduce deviation rate of IOL and obtain better visual quality in cataract patients.

SELECTION OF CITATIONS
SEARCH DETAIL