Results 1 - 10 de 10
Filter
1.
Arq. bras. oftalmol ; 86(4): 330-336, July-Sep. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1447371

ABSTRACT

ABSTRACT Purpose: To evaluate the efficacy of soft HydroCone silicone hydrogel contact lenses in patients with posterior microphthalmos. Methods: The charts of 13 patients with posterior microphthalmos (26 eyes) who were fitted with soft HydroCone silicone hydrogel contact lenses were reviewed retrospectively. All the patients underwent assessments of uncorrected and best spectacle-corrected visual acuity and cycloplegic refraction. They were fitted with contact lenses according to the parameter values obtained from the topographical analysis and best contact lens-corrected visual acuity measurement. Results: The spherical equivalents of the right and left eyes ranged from 10.00 to 19.25 diopters and from 11.00 to 21.5 diopters, respectively. The mean axial and posterior chamber lengths were shorter than those of the age-matched population. However, the mean values of the anterior segment parameters such as horizontal visible iris diameter, central anterior chamber depth, lens thickness, and central corneal thickness were in the normal range. The mean keratometric measurements revealed increased corneal curvature compared with that in the normal population. The mean best contact lens-corrected visual acuity was significantly higher than the mean best spectacle-corrected visual acuity for both eyes (p=0.045). Conclusion: HydroCone silicon soft contact lenses provided better visual acuity than spectacles in the patients with posterior microphthalmos in this study.


RESUMO Objetivo: Avaliar a eficácia das lentes de contato gelatinosas HydroCone, de hidrogel com silicone, em pacientes com microftalmia posterior. Métodos: Foram revisados retrospectivamente 26 olhos com microftalmia posterior, a partir dos prontuários de 13 pacientes que receberam lentes de contato gelatinosas HydroCone, de hidrogel com silicone. Todos os pacientes foram submetidos ao exame de acuidade visual não corrigida e com melhor correção por óculos e com refração cicloplégica. Todos os pacientes receberam lentes de contato de acordo com os parâmetros obtidos na análise topográfica e foi obtida a melhor acuidade visual corrigida com lentes de contato. Resultados: O equivalente esférico do olho direito variou de 10,00 a 19,25 dioptrias, e o do olho esquerdo de 11,00 a 21,5 dioptrias. Os comprimentos médios axiais e das câmaras posteriores foram menores do que para a população de mesma idade. No entanto, os valores médios dos parâmetros do segmento anterior, como o diâmetro horizontal visível da íris, a profundidade da câmara anterior central, a espessura da lente e a espessura central da córnea estavam dentro da faixa normal. Os valores médios da ceratometria revelaram curvatura corneana aumentada em relação à população normal. A média da melhor acuidade visual corrigida com lentes de contato foi significativamente maior que a média da melhor acuidade visual corrigida com óculos em ambos os olhos (p=0,045). Conclusão: As lentes de contato gelatinosas de silicone HydroCone proporcionam melhor acuidade visual que óculos em pacientes com microftalmia posterior.

2.
Arq. bras. oftalmol ; 84(5): 462-466, Sept.-Oct. 2021. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1339212

ABSTRACT

ABSTRACT Purpose: Microcornea is a rare condition that frequently resulets in serious cosmetic concerns due to the resultant asymmetrical appearance of the eye, and its cosmetic rehabilitation is possible with the use of colored contact lenses. This paper aims to present our experiences with the use of cosmetic Etafilcon A contact lenses for microcornea. Methods: Eight patients with unilateral microcornea without any systemic involvement were included in this study, and they underwent routine ophthalmological examination, corneal topography, and optical biometry. We applied the cosmetic Etafilcon A contact lens (1-DAY ACUVUE® DEFINE® with Lacreon®) of the same edge color to the patients. The levels of satisfaction in terms of cosmesis and comfort were evaluated with the use of visual analog scales (VAS). Results: In the patients, the corneal diameter asymmetry was acceptably adjusted, and each of the patients reported extreme satisfaction. The mean VAS score was 8.9 ± 1.0 (range: 7-10) for the cosmetic satisfaction rate and 8.4 ± 1.0 (range: 7-10) for the comfort rate. The patients obtained the best-corrected visual acuity without or with additional eye-glasses. None of the patients complained about vision issues under photopic and scotopic conditions. Conclusion: 1-DAY ACUVUE® DEFINE® with Lacreon® lens has promising satisfactory cosmetic outcomes along with visual enhancement in cases of microcornea. This is the first study to report the use of this lens for the cosmetic rehabilitation of patients with microcornea.


RESUMO Objetivo: A microcórnea é uma afecção rara, que frequentemente causa graves queixas estéticas devido a uma aparência assimétrica, mas passível de reabilitação estética através de lentes de contato coloridas. O objetivo deste estudo é apresentar nossas experiências no uso de lentes de contato cosméticas Etafilcon A em casos de microcórnea. Métodos: Oito pacientes com microcórnea unilateral, sem acometimento sistêmico, foram incluídos e submetidos a exame oftalmológico de rotina, topografia corneana e biometria óptica. Aplicamos nos pacientes uma lente de contato cosmética Etafilcon A (1-Day Acuvue® Define® com Lacreon®) da mesma cor da borda da córnea dos pacientes. Os níveis de satisfação em termos de estética e conforto foram avaliados por meio de escalas visuais analógicas (EVA). Resultados: A assimetria do diâmetro da córnea foi corrigida em um grau aceitável e todos os pacientes ficaram muito satisfeitos. A pontuação média da EVA foi de 8,9 ± 1,0 (variação: 7-10) para o grau de satisfação estética e 8,4 ± 1,0 (intervalo: 7-10) para o grau de conforto. Os pacientes obtiveram a melhor acuidade visual corrigida com ou sem óculos adicionais. Não houve queixas visuais em condições fotópicas ou escotópicas. Conclusão: A lente 1-Day Acuvue® Define® com Lacreon® é promissora em termos de resultados estéticos satisfatórios, bem como de melhoria da visão em casos de microcórnea. Este é o primeiro estudo a relatar o uso dessa lente na reabilitação cosmética de pacientes com microcórnea.

3.
Arq. bras. oftalmol ; 79(4): 255-257, July-Aug. 2016. graf
Article in English | LILACS | ID: lil-794585

ABSTRACT

ABSTRACT A 51-year-old patient underwent posterior vitrectomy with perfluoropropane gas injection, phacoemulsification, and implantation of an Oft Cryl® hydrophilic acrylic intraocular lens (IOL) because of traumatic retinal detachment and cataract in the right eye. On the first postoperative day, gas was filling the anterior chamber because of patient's non-compliance in terms of head positioning, and was reabsorbed within one week. Eight months later, the patient returned complaining of a significant decrease in vision. IOL opacification was noticed by slit-lamp examination. The lens was explanted to undergo gross and light microscopic analysis. The lens was also stained with the alizarin red method for calcium identification. Light microscopic analysis confirmed the presence of granular deposits, densely distributed in an overall circular pattern in the central part of the lens optic. The granules stained positive for calcium. This is the first case of the opacification of this type of hydrophilic lens. Surgeons should be aware of this potential postoperative complication, and the use of hydrophilic IOLs should be avoided in procedures involving intracameral gas because of the risk of IOL opacification.


RESUMO Uma paciente de 51 anos foi submetida à vitrectomia posterior com injeção de gás perfluoropropano, facoemulsificação e implante de lente intraocular (LIO) acrílica hidrofílica Oft cryl® devido a descolamento traumático da retina e catarata. No primeiro dia pós-operatório, o gás estava ocupando a câmara anterior pois a paciente não manteve o decúbito ventral restrito, tendo sido absorvido ao longo de uma semana. Oito meses depois, a paciente retornou com baixa da acuidade visual. Ao exame foi evidenciado opacificação da lente intraocular. A lente foi explantada e submetida à análise macroscópica e sob microscopia óptica. Também, foi corada pelo método de vermelho de alizarina, que identifica cálcio. A análise sob microscopia óptica evidenciou depósitos granulares, densamente distribuídos em padrão circular na parte central da óptica da lente intraocular, que coraram positivo para cálcio. Esse é o primeiro relato de opacificação dessa lente hidrofílica. Os cirurgiões devem estar atentos para esta potencial complicação pós-operatória.


Subject(s)
Humans , Female , Middle Aged , Postoperative Complications/etiology , Prosthesis Failure/etiology , Lens Implantation, Intraocular/adverse effects , Lenses, Intraocular/adverse effects , Vitrectomy , Phacoemulsification , Device Removal , Fluorocarbons , Microscopy/methods
4.
Rev. bras. oftalmol ; 71(5): 322-324, set.-out. 2012. ilus
Article in Portuguese | LILACS | ID: lil-654993

ABSTRACT

Apesar de rara, a ocorrência de lesão ocular devido à explosão acidental de disco compacto pode ser responsável por graves lesões no globo ocular. No presente artigo é relatado caso de perfuração corneana com trauma cristaliniano causado pela quebra intencional de disco compacto. Trata-se de paciente com 44 anos, sexo feminino, médica, avaliada em caráter de urgência com queixas de BAV, fotofobia, lacrimejamento e sensação de corpo estranho no OD, iniciados após presenciar quebra intencional de disco compacto. Apresentava perfuração corneana central, com sinal de Seidel positivo e lesão de cápsula anterior do cristalino com opacificação cortical anterior subjacente. A AV corrigida no OD era de 0,1. Tratada com lente de contato hidrofílica terapêutica e instilações tópicas regulares de solução antibiótica e hipotensora ocular, evoluiu com cicatrização da lesão corneana e estabilização da opacidade do cristalino. Decorridos 24 meses do trauma, sua refração encontrava-se semelhante aos valores prévios ao acidente e a acuidade visual era de 1,0 (-1).


Despite being rare, ocular injury due to a compact disc burst can be responsible for severe ocular damage. We present in this article a case of corneal perforation in addition to lens trauma caused by intentional compact disc break. A 44 year old female physician was examined complaining of visual acuity decrease, light sensitivity, tearing and foreign body sensation on OD after watching a compact disc being broken intentionally. In the first examination, she had a corneal perforation with aqueous humor leakage, anterior lens capsule lesion and anterior cortical opacity. The visual acuity was 0.1. She was treated with a therapeutic soft contact lens and the regular use of topical antibiotic and hypotension solutions, evolving with the healing of the corneal injury and lens opacity stabilization. Twenty four months later, the OD refraction was similar to that measured before the trauma and the visual acuity was 1.0 (-1).


Subject(s)
Humans , Female , Adult , CD-ROM , Contact Lenses, Hydrophilic , Corneal Perforation , Eye Foreign Bodies , Photophobia
5.
Arq. bras. oftalmol ; 72(5): 626-630, set.-out. 2009. ilus, tab
Article in English | LILACS | ID: lil-534180

ABSTRACT

OBJETIVO: Avaliar a influência da ação antimicrobiana das soluções multiuso para desinfecção de lentes de contato hidrofílicas. MÉTODOS: Duas soluções multiuso denominadas solução A (poliquaternário-1 a 0,001 por cento e miristamidopropil dimetilamina a 0,0005 por cento) e solução B (poliaminopropil biguanida a 0,0001 por cento) foram testadas em lentes de contato hidrofílicas contaminadas com Pseudomonas aeruginosa (ATCC27583), Staphylococcus epidermidis (ATCC1226), Klebsiella pneumoniae (ATCC13883), Staphylococcus aureus (ATCC25923) e Candida albicans (ATCC 10231) para verificar a quantidade de redução do crescimento dos microrganismos após o enxágue com as soluções. Foram seguidas as instruções preconizadas pelos fabricantes. RESULTADOS: Houve redução de 90 por cento do crescimento de Pseudomonas aeruginosa, Staphylococcus epidermidis, Staphylococcus aureus e Candida albicans. Não houve crescimento de Klebsiella pneumoniae. CONCLUSÃO: As soluções testadas neste trabalho mostraram redução do número de microrganismos testados.


PURPOSE: To evaluate the efficacy of disinfecting solutions in hydrophilic contact lenses (CL). METHODS: Two multi-use solutions denominated solution A (0.001 percent polyquaternium-1 and 0.0005 percent myristamidopropyl dimethylamine) and solution B (0.0001 percent polyaminopropyl biguanide) were used. The solutions were tested in hydrophilic contact lenses infected with Pseudomonas aeruginosa (ATCC27583), Staphylococcus epidermidis (ATCC1226), Klebsiella pneumoniae (ATCC13883), Staphylococcus aureus (ATCC25923) and Candida albicans (ATCC 10231) and the decrease in microorganisms growth after the hydrophilic contact lenses were cleaned with the respective solutions was verified. The manufacture's instructions were followed. RESULTS: A decrease of 90 percent of Pseudomonas aeruginosa, Staphylococcus epidermidis, Staphylococcus aureus, Candida albicans and a decrease 100 percent of Klebsiella pneumoniae was observed. CONCLUSION: The solutions decreased the amount of microorganisms tested.


Subject(s)
Animals , Bacteria/drug effects , Candida albicans/drug effects , Contact Lens Solutions/pharmacology , Contact Lenses, Hydrophilic/microbiology , Disinfectants/pharmacology , Bacteria/growth & development , Biguanides/pharmacology , Colony Count, Microbial , Candida albicans/growth & development , Klebsiella/drug effects , Klebsiella/growth & development , Polymers/pharmacology , Propylamines/pharmacology , Propylamines/standards , Pseudomonas aeruginosa/drug effects , Pseudomonas aeruginosa/growth & development , Staphylococcus aureus/drug effects , Staphylococcus aureus/growth & development , Staphylococcus epidermidis/drug effects , Staphylococcus epidermidis/growth & development
6.
Arq. bras. oftalmol ; 72(2): 174-179, mar.-abr. 2009. ilus, graf
Article in Portuguese | LILACS | ID: lil-513884

ABSTRACT

OBJETIVO: Desenvolver simulação computadorizada de ablação para produzir lentes de contato personalizadas a fim de corrigir aberrações de alta ordem. MÉTODOS: Usando dados reais de um paciente com ceratocone, mensurados em um aberrômetro ("wavefront") com sensor Hartmann-Shack, foram determinados as espessuras de lentes de contato que compensam essas aberrações assim como os números de pulsos necessários para fazer ablação as lentes especificamente para este paciente. RESULTADOS: Os mapas de correção são apresentados e os números dos pulsos foram calculados, usando feixes com a largura de 0,5 mm e profundidade de ablação de 0,3 µm. CONCLUSÕES: Os resultados simulados foram promissores, mas ainda precisam ser aprimorados para que o sistema de ablação "real" possa alcançar a precisão desejada.


PURPOSE: To develop a computer simulation for customized soft contact lenses in order to correct aberrations of higher order. METHODS: Using real data from a patient diagnosed with keratoconus, which were measured using a Hartmann-Shack wavefront sensor, the thickness of the contact lenses that compensate these aberrations as well the numbers of pulses required to ablate the lenses were specifically determined for the patient. RESULTS: The maps of correction are presented and the numbers of pulses are calculated, using a 0.5 mm beam width and a 0.3 µm ablation depth. CONCLUSIONS: The results shown here are promising, but they should be improved so that the ablation in actual physical systems can reach the desired accuracy.


Subject(s)
Humans , Algorithms , Contact Lenses, Hydrophilic , Image Interpretation, Computer-Assisted/methods , Keratoconus/rehabilitation , Materials Testing/instrumentation , Corneal Topography , Equipment Design
7.
Arq. bras. oftalmol ; 71(6,supl.0): 19-22, nov.-dez. 2008.
Article in Portuguese | LILACS | ID: lil-507469

ABSTRACT

As lentes de contato terapêuticas são úteis para o tratamento de uma série de doenças da superfície ocular. Suas principais finalidades são: reduzir a dor; proteger a córnea; facilitar e manter a cicatrização epitelial; restaurar a câmara anterior e liberar medicamentos na superfície ocular. Há uma variedade de tipos e materiais, sendo que a escolha depende da doença a ser tratada, tempo de uso e necessidades fisiológicas do olho doente. Doenças como a ceratopatia bolhosa, erosão recorrente do epitélio corneano, olho seco e defeitos epiteliais pós-operatórios, além de várias outras doenças que afetam a superfície ocular podem ser tratadas com a utilização das lentes de contato terapêuticas. Elas não devem ser utilizadas em processos infecciosos ou em pacientes que estão impossibilitados de retornar para acompanhamento regular. A adaptação, controle e manutenção adequados das lentes de contato terapêuticas são fundamentais para prevenir complicações, como: neovascularização corneana, conjuntivite papilar gigante ou ceratite infecciosa. O controle e manutenção foram facilitados com o advento das lentes de contato terapêuticas de silicone-hidrogel. Essas lentes permitem trocas menos freqüentes devido a sua maior oxigenação e, em casos selecionados, aceleram a reepitelização corneana.


Therapeutic contact lenses are useful in a variety of ocular surface diseases. Their main indications are: to relieve the pain; protect ocular surface; promote corneal healing and epithelial regeneration; seal a leaking corneal wound and deliver ophthalmic drugs on the ocular surface. There are several kinds of lens designs and materials, and their choice is dependent on the specific disease to be treated, the duration of treatment and the physiologic needs of the diseased cornea. Bullous keratopathy, recurrent epithelial erosion syndrome, dry eye and postoperative epithelial defects are amongst their indications. Therapeutic contact lenses should not be indicated in the presence of active infectious keratitis or when the patient is not compliant. Corneal neovascularization, giant papillary conjunctivitis and infectious keratitis are serious complications, which can be prevented by correctly fitting and maintaining the therapeutic contact lenses. Silicon-hydrogel therapeutic contact lenses, due to their higher oxygen permeability, allow extended wear schedules, decreasing the need for frequent lens replacement.


Subject(s)
Humans , Contact Lenses , Corneal Diseases/therapy , Oxygen/metabolism , Disinfection , Hydrogels , Permeability , Silicon
8.
Rev. bras. oftalmol ; 67(3): 138-141, maio-jun. 2008. ilus
Article in Portuguese | LILACS | ID: lil-487529

ABSTRACT

Relatamos um caso de endotelite que se expressou inicialmente como uma cerato-neurite em pacientes usuários de lente de contato gelatinosa e de inadequado uso de solução salina . Trata-se de uma paciente de 41 anos, branca feminina, que se queixava de intensa dor no olho esquerdo e que ao exame biomicroscópico revelou edema corneano microcístico e ceratoneurite radial. Foram realizadas cultura e biopsia corneana e todos testes foram negativos. O tratamento com excelente resposta terapêutica reduziu o edema da córnea e aliviou a dor ocular consistiu de dexametasona 0,1 por cento tópica sob a forma de pomada e acyclovir oral.


We decribed a case of endothelitis that began with keratoneuritis in patient who wore soft contact lens and saline solution with poor hygiene. A 41 years old ,white female suffered from severe pain in her left eye, with microcystic corneal edema and radial keratoneuritis .Culture and corneal byopsia was made, and all tests were negative.The treatment including topical dexametasona 0.1 percent ophthalmic solution and oral acyclovir successfully controlled the corneal edema and the pain.

9.
Arq. bras. oftalmol ; 71(3): 430-433, maio-jun. 2008. ilus, tab
Article in English | LILACS | ID: lil-486126

ABSTRACT

This is the report of a case of bilateral Acanthamoeba keratitis in a 19-year-old woman who bought a pair of disposable soft contact lenses in a boutique. She wore this same pair of lenses for 3 months daily without the appropriate care. This led to bilateral corneal transplantation with cataract extraction and also trabeculectomy in the right eye. When last seen, both grafts were crystal clear but the visual acuities were far from satisfactory. She also had bilateral secondary glaucoma, barely controlled by topical medication. Actually, the physical features and the wearing time characteristics of the disposable soft contact lenses created unprecedented difficulties to the medical surveillance of their wearers. Without the right assistance they tend to become careless regarding routine cleaning. They also feel free to buy less expensive lenses, to use saline instead of lens solutions, to violate the limits of wearing time and to extend the use over the sleeping period. Additionally, the aggressive marketing and the wide distribution of these lenses increase the chances that economically or educationally unprepared people will acquire them. The question that remains is: Is the present case an accidental event or an example of what is likely to happen in the future if the indiscriminate selling of disposable soft contact lenses continues to evolve?


Este é o relato de uma paciente do sexo feminino, de 19 anos, com ceratite bilateral por Acanthamoeba, devido ao uso de lentes de contato descartáveis, adquiridas em uma butique. Fez uso do mesmo par de lentes durante três meses, sem os cuidados adequados. Foi submetida a transplante penetrante de córnea e facectomia bilateral, além de trabeculectomia no olho direito. Quando vista pela última vez, os enxertos estavam transparentes, mas a visão de ambos os olhos não era satisfatória. Ela também apresentava glaucoma secundário bilateral, controlado precariamente com medicação tópica. Ocorre que, as características físicas e o regime de uso das lentes de contato gelatinosas descartáveis criam dificuldades adicionais para a vigilância médica dos seus usuários. Sem a assistência correta, eles relaxam com a rotina de limpeza, compram lentes mais baratas, usam soro fisiológico ao invés das soluções adequadas, violam os limites de uso e dormem com as mesmas. Além disso, o "marketing" agressivo e a ampla distribuição dessas lentes aumentam as chances de que pessoas, não preparadas econômica e educacionalmente, venham ter acesso às mesmas. A pergunta que fica é: Seria o presente caso um evento acidental ou um exemplo do que pode acontecer no futuro caso as lentes de contato descartáveis continuem sendo vendidas indiscriminadamente?


Subject(s)
Animals , Female , Humans , Young Adult , Acanthamoeba , Amebiasis/complications , Contact Lenses/adverse effects , Corneal Ulcer/parasitology , Marketing , Corneal Ulcer/complications , Corneal Ulcer/therapy , Young Adult
10.
Arq. bras. oftalmol ; 70(1): 67-72, jan.-fev. 2007. ilus
Article in Portuguese | LILACS | ID: lil-453131

ABSTRACT

OBJETIVO: Lentes de contato gelatinosas com curvas-base esféricas têm sido usadas há anos. O cálculo do poder refrativo de lentes deste tipo é fácil, bastando utilizarmos a equação do fabricante de lentes para lentes espessas. No entanto, para projetos de lentes de contato personalizadas, não há ainda métodos confiáveis para medida das aberrações ópticas de ordem mais alta. Esse trabalho foi desenvolvido no laboratório do Centro de Ciências da Visão (Center for Visual Science) da Universidade de Rochester, Nova York, com aparelho óptico que permite realizar medidas precisas de aberrações de ordem baixa e alta de lentes de contato gelatinosas personalizadas. Este é um passo essencial na verificação e obtenção de lentes de contato personalizadas de qualidade, e o instrumento desenvolvido na Universidade de Rochester permite verificar a qualidade de fabricação destas lentes. MÉTODOS: Um aparelho óptico de bancada foi montado em laboratório. Este aparelho consiste de uma célula úmida onde as lentes de contato são depositadas. Consiste também de uma série de lentes e espelhos e um sensor de frente-de-onda de Hartmann-Shack. As lentes de contato personalizadas utilizadas neste projeto foram fabricadas pela empresa Bausch & Lomb. Das dezenas de lentes de contato mensuradas no aparelho, restringimos aqui a apresentar os resultados de uma lente personalizada para ceratocone. RESULTADOS: O erro quadrático médio (EQM) do instrumento foi de 0,04 micrômetro, sendo que o EQM das aberrações induzidas na lente está entre 4 e 6 micrômetros, ou seja, a precisão do aparelho está em torno de 1 por cento. Este valor é mais do que suficiente para medidas precisas destes tipos de lentes de contato, algo até então inviável utilizando-se os sensores ou aparelhos convencionais de aberrometria. CONCLUSÃO: Com o instrumento desenvolvido neste trabalho foi possível realizar medidas precisas de aberrações de alta ordem. Esta tecnologia é importante para o desenvolvimento...


PURPOSE: Soft contact lenses with spherical base curves have been used for many years. The computation of the refractive powers of these lenses is easy, requiring only that one uses the lens maker equation for thick lenses. Nevertheless, for customized contact lenses, there is yet no reliable method for measuring the higher order optical aberrations. In this study we have developed in the Center for Visual Sciences of the University of Rochester an optical apparatus that allows for precise measurement of low and high order aberrations of customized soft contact lenses. METHODS: An optical apparatus was mounted on a conventional optical bench. This apparatus consists of a wet cell where the contact lenses are placed, a series of relay lenses, mirrors, beam splitters, and a Hartmann-Shack sensor. Bausch & Lomb manufactured the lenses used in this study. RESULTS: The root mean square error (RMSE) of the instrument was 0.04 microns. Given that the RMSE of the customized lens is between 4 and 6 microns, i.e., the precision of the instrument is approximately 1 percent. This precision is more than sufficient for the type of measurements necessary for manufacturing customized contact lenses. CONCLUSION: The instrument developed is extremely precise for measuring high order aberrations - up to the 10th order Zernike polynomials, that is, up to the 66th term. This technology is important for the development of new methods of optical corrections for patients that usually do not adapt to normal sphere-cylinder spectacles or that cannot undergo refractive surgery, such as those which have keratoconus, for example.


Subject(s)
Humans , Contact Lenses, Hydrophilic , Equipment Failure Analysis/methods , Image Enhancement/instrumentation , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Refractometry/instrumentation , Equipment Design , Refractometry/methods