Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 352
Filter
1.
Journal of Sun Yat-sen University(Medical Sciences) ; (6): 108-113, 2024.
Article in Chinese | WPRIM | ID: wpr-1007281

ABSTRACT

ObjectivesTo compare the clinical efficacy and complications of anatomic locking titanium plate (hereinafter referred to as “titanium plate screw”) and intramedullary nail in the treatment of distal tibial fractures.Methods From September 2019 to September 2021, 32 patients diagnosed with AO-A fracture of distal tibia at Sun Yat-sen Memorial Hospital of Sun Yat-sen University were included in this study. Of these, 15 cases were treated with titanium plate screws and 17 cases were treated with intramedullary nails. General surgical indexes, fracture healing time and postoperative operation were compared between the two groups.ResultsAll patients were followed up for 10 to 20 months, with an average of 12 months. The operative time and intraoperative fluoroscopy times of intramedullary nail group were longer than those of titanium plate screw group, but the preoperative waiting time and hospitalization days was less or were fewer than those of titanium plate screw group, the difference was statistically significant (P < 0.05). There was no significant difference in fracture healing time between the two groups (P> 0.05). At 6 weeks after operation, VAS scores in both groups were lower than those before operation, with statistically significant difference (P<0.05). There was no significant difference in VAS scores between the intramedullary nail group and the titanium plate screw group (P> 0.05). AOFAS scores 6 months after surgery, ankle joint motion and complication rate 1 year after surgery in intramedullary screw group were better than those in titanium plate screw group, and the differences were statistically significant (P< 0.05). There was no significant difference in AOFAS scores between the two groups at 1 year after operation (P> 0.05).ConclusionTitanium plate screw and intramedullary nail are both effective methods for the treatment of distal tibial AO-A fracture, and there is no significant difference in long-term clinical efficacy. Intramedullary nail has fewer soft tissue complications, less impact on ankle motion, faster recovery and higher safety, while titanium plate screw has a higher probability of postoperative soft tissue infection. We suggest that in clinical work, preoperative evaluation of patients should be done well. Under the premise of grasping the indications, intramedullary nail has fewer complications and certain advantages.

2.
China Journal of Orthopaedics and Traumatology ; (12): 57-60, 2024.
Article in Chinese | WPRIM | ID: wpr-1009223

ABSTRACT

OBJECTIVE@#To compare the biomechanical stability of three cross-bridge headless compression screws and locking plates in the fixation of Mason type Ⅲ radial head fractures by finite element method.@*METHODS@#Using reverse modeling technology, the radial CT data and internal fixation data of a healthy 25-year-old male were imported into the relevant software. Three-dimensional finite element model of 3 cross-bridge headless compression screws and locking plates for MasonⅢ radial head fractures were established, and the radial head was loaded with 100 N axial loading. The maximum displacement, maximum Von Mises stress and stress distribution of the two groups were compared.@*RESULTS@#The maximum displacements of the three cross-bridge screws group and locking plate group were 0.069 mm and 0.087 mm respectively, and the Von Mises stress peaks were 18.59 MPa and 31.85 MPa respectively. The stress distribution of the three screws group was more uniform.@*CONCLUSION@#Both internal fixation methods can provide good fixation effect. CoMPared with the locking plate fixation method, the 3 cross-bridge headless compression screws fixation is more stable and the stress distribution is more uniform.


Subject(s)
Male , Humans , Adult , Finite Element Analysis , Radial Head and Neck Fractures , Bone Screws , Biomechanical Phenomena , Radius Fractures/surgery , Fracture Fixation, Internal/methods , Bone Plates , Fractures, Comminuted
3.
Article | IMSEAR | ID: sea-221474

ABSTRACT

Background- Fractures of distal femur are one of the most prevalent fractures encountered in high-velocity trauma which are associated with high morbidity and mortality if not managed well. The isolated fracture can itself lead to complications such as Acute Respiratory Distress and pulmonary embolism. This neccesitaties early stabilisation of the fractures. Open reduction and internal fixation (ORIF) with locking compression plate is the treatment of choice for closed fractures of the distal femur. Distal femur anatomic contoured locking compression plate (LCP) has shown to give one of the best results regarding recovery, fracture union, return to work and the functional outcome. We present our experience of management of distal femur fracture at our centre. Study Material and Methodsdone on 36 patients, (NEER'S Classification) age range of 18 to 70 years (irrespective of their sex), were subjected to fixation by locking compression plate after obtaining thorough written informed consent. The observational study was carried at our institute between June 2021 to June 2022 Patients of both gender who were skeletally mature are taken into the study. In 61.5% of patients up to 50 years old and in Results40% of patients older than 50 years, the functional evaluation of LCP using Neers criteria was excellent. There was no statistically significant (p>0.05) difference in patients' functional status according to their age group who had distal femur fractures, which were stabilise by LCP. For supracondylar femur fractures, locking compression plates is a safe technique that has a good functional outcome, early clinical and radiographic union, and few complications.

4.
Chinese Journal of Orthopaedic Trauma ; (12): 635-639, 2023.
Article in Chinese | WPRIM | ID: wpr-992760

ABSTRACT

Objective:To evaluate the minimally invasive fixation with a locking plate via the tarsal sinus approach in the surgical treatment of Sanders Ⅱ and Ⅲ calcaneal fractures.Methods:A retrospective study was conducted to analyze the 65 patients who had been surgically treated for Sanders Ⅱ and Ⅲ calcaneal fractures at Department of Foot and Ankle Surgery, Binzhou Medical College Hospital from April, 2019 to September, 2020. There are 44 males and 21 females with an age of (42.5±10.4) years, and 46 Sanders type Ⅱ fractures and 19 Sanders type Ⅲ ones. The patients were divided into group L and group S according to surgical methods. Group S of 35 cases was fixated with a minimally invasive locking plate through the tarsal sinus incision while group L of 30 cases fixated with a locking plate through the L-shaped incision. The 2 groups were compared in terms of waiting time before surgery, surgical time, hospital stay, intraoperative bleeding, visual analogue scale (VAS) at 3 days after surgery, American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score at 1 year after surgery, excellent and good rate by the Maryland foot function score, B?hler angle, Gissane angle, varus angle, and complications.Results:There was no significant difference in the general data before surgery between the 2 groups, showing comparability ( P>0.05). All patients were followed up for (13.3±1.6) months after surgery. The waiting time before surgery [(2.8±1.8) d], surgical time [(80.7±9.9) min], hospital stay [(6.7±1.9) d], intraoperative bleeding [(54.3±14.2) mL], and VAS at 3 days after surgery [6 (5, 7) points] in group S were all significantly less or lower than those in group L [(8.2±2.8) d, (105.0±15.7) min, (14.6±3.4) d, (74.3±12.8) mL, and 7 (6, 8) points] (all P<0.05). At one year after surgery, the AOFAS ankle-hindfoot score [(90.1±3.5) points] in group S was significantly higher than that in group L [(83.5±6.7) points] ( P<0.05), but there was no statistically significant difference in the excellent and good rate by the Maryland foot function score between the 2 groups [91.4% (32/35) versus 86.7% (26/30)] ( P=0.695). The B?hler angle, Gissane angle, and varus angle were significantly improved in all patients one year after surgery compared with the values before surgery ( P<0.05), but there were no statistically significant differences within either group or between the 2 groups at 3 days or 1 year after surgery ( P>0.05). Peroneal muscle pain was reported in 1 case in group S; there were 2 cases of skin necrosis, 1 case of incision hematoma and 1 case of sural nerve injury in group L. Conclusion:The minimally invasive fixation with a locking plate via the tarsal sinus approach is an effective treatment for Sanders Ⅱ and Ⅲ calcaneal fractures.

5.
Chinese Journal of Orthopaedic Trauma ; (12): 422-426, 2023.
Article in Chinese | WPRIM | ID: wpr-992728

ABSTRACT

Objective:To evaluate the radiological and clinical outcomes of the aged patients with unstable proximal humeral fracture (UPHF) treated with a locking plate and an intramedullary titanium mesh.Methods:A retrospective study was conducted to analyze the 43 aged patients with UPHF who had been admitted to Department of Orthopedics, Zhongda Hospital Affiliated to Southeast University from January 2017 to July 2019. There were 13 males and 30 females with an age of (71.3±10.3) years (from 60 to 83 years). All patients were treated with a locking plate and an intramedullary titanium mesh to support. The postoperative imaging measurements included changes in humeral head height (HHH) and neck-shaft angle (NSA) (the difference between 3 years after surgery and the second day after surgery, taken as an absolute value); the postoperative clinical measurements included visual analogue scale (VAS), range of shoulder motion, Constant-Murley shoulder functional score (Constant score), American Shoulder and Elbow Surgeons (ASES) score, and incidence of complications.Results:All patients were followed up for (39.2±2.3) months after surgery. The change in HHH at 3 years after surgery was (1.5±1.1) mm, and the change in NSA at 3 years after surgery 3.3°±2.6°. At 3 years after surgery, the VAS score was (2.2±1.3) points, the Constant score (79.2±9.1) points, and the ASES score (78.9±9.2) points; the range of forward extension was 143.2°±20.8°, the range of outward extension 139.3°±23.1°, and the range of outward rotation 55.1°±4.7°. Complications after surgery were found in 6 patients, including humeral head necrosis in 2 cases, ectopic ossification in 1 case, and infection in 3 cases.Conclusion:In the treatment of the aged patients with UPHF, a locking plate combined with an intramedullary titanium mesh can help to restore the medial column support, leading to fine radiological and clinical outcomes.

6.
Chinese Journal of Orthopaedic Trauma ; (12): 407-414, 2023.
Article in Chinese | WPRIM | ID: wpr-992726

ABSTRACT

Objective:To compare the clinical effectiveness between arthroscopic hollow screws combined with a suture anchor, hollow screws and proximal humerus internal locking system (PHILOS) in the treatment of split-type fractures of humeral greater tuberosity.Methods:A retrospective study was conducted to analyze the 54 patients with split-type fracture of humeral greater tuberosity who had been admitted to Department of Joint Surgery, Hospital of Traditional Chinese Medicine, Affiliated to Southwest Medical University from May 2015 to August 2020. There were 17 males and 37 females with an age of (58.4±12.1) years. According to different treatment methods, they were divided into 3 groups. Group A of 18 cases was treated with arthroscopic hollow screws combined with a suture anchor, group B of 18 cases with hollow screws, and group C of 18 cases with PHILOS. The length of surgical incision, and range of shoulder motion, visual analogue scale (VAS), and American Shoulder and Elbow Surgeons (ASES) score at the last follow-up were recorded and compared between the 3 groups.Results:There was no statistically significant difference in the preoperative general information between the 3 groups, indicating the 3 groups were comparable ( P>0.05). The surgical incision in group A [(0.7±0.1) cm] was the shortest, followed by (5.0±1.4) cm in group B, and (12.8±2.1) cm in group C, showing statistically significant differences in pairwise comparison ( P<0.05). In the 3 groups at the last follow-up, respectively, the shoulder forward flexion was 159.7°±13.4°, 154.9°±16.2°, and 160.5°±12.9°, and the shoulder abduction 149.6°±11.3°, 142.4°±12.0°, and 145.1°±10.4°, showing no statistically significant difference among the 3 groups ( P>0.05); the external rotation was 41.1°±8.1°, 38.1°±7.8° and 43.7°±6.2°, showing a statistically significant difference between groups B and C ( P<0.05); the dorsal extension was T 12 (L 5 to T 6), T 12 (L 5 to T 7), and T 12 (L 3 to T 6), showing no statistically significant difference among the 3 groups ( P>0.05). There was no statistically significant difference among the 3 groups in the VAS score or ASES score at the last follow-up ( P>0.05). Respectively, there were 2, 6, and 4 patients in groups A, B and C who developed complications, showing statistically significant differences between the 3 groups ( P<0.05). Conclusions:In the treatment of split fractures of humeral greater tuberosity, arthroscopic hollow screws combined with a suture anchor, hollow screws and PHILOS can all relieve pain and restore joint function of the shoulder. However, arthroscopic hollow screws combined with a suture anchor are the most recommendable due to their advantages in minimally invasiveness and reduction in complications.

7.
China Journal of Orthopaedics and Traumatology ; (12): 1191-1195, 2023.
Article in Chinese | WPRIM | ID: wpr-1009210

ABSTRACT

OBJECTIVE@#To explore clinical effect of attaching locking plate with bone grafting based on retaining the original intramedullary nail in treating non-union after intramedullary nail fixation of long shaft fractures of lower limbs.@*METHODS@#A retrospective study was conducted on 20 patients treated with non-union fractures after intramedullary nailing of long shaft fractures of lower limbs from June 2015 to June 2020. All patients were treated with the original intramedullary nailing and bone grafting from the iliac bone, and were underwent open reduction plate internal fixation and bone grafting for old fractures. Among them, 14 were males and 6 were females, aged from 35 to 56 years old with an average of (42.2±9.6) years old. Nine patients were femoral shaft fracture and 11 patients were tibial shaft fracture. According to characteristics of fracture end nonunion, 6 patients were stable/atrophic, 9 patients were unstable/large, and 5 patients were unstable/atrophic. The nonunion time ranged from 8 to 12 months with an average of(9.8±2.0) months after the initial surgery. Visual analogue scale (VAS), knee range of motion, bone healing time, complications and fracture-end healing were recorded before and at the latest follow-up.@*RESULTS@#All patients were followed up for 18 to 48 months with an average of (36.3±10.5) months. The incision of all patients were healed at stageⅠwithout complications such as infection or internal fixation ruptur. Healing time of femur and tibia was (8.5±2.6) months and (9.5±2.2) months. Knee joint motion increased from preoperative (101.05±8.98) ° to postoperative (139.35±8.78) ° at the latest follow-up (t=-12.845, P<0.001). VAS decreased from preoperative (5.15±1.72) to postoperative (0.75±0.96) at the latest follow-up (t=11.186, P<0.001).@*CONCLUSION@#On the basis of retaining the original intramedullary nail, the addition of locking plate internal fixation and autogenous iliac bone grafting have advantages of simple operation, less trauma, fewer complications and high fracture healing rate. It is one of the effective surgical schemes for the treatment of nonunion after intramedullary nail fixation of long bone fracture of lower extremity.


Subject(s)
Male , Female , Humans , Adult , Middle Aged , Bone Transplantation , Retrospective Studies , Bone Plates , Fracture Fixation, Intramedullary/adverse effects , Femoral Fractures/complications , Lower Extremity , Fractures, Ununited/surgery , Fracture Healing , Tibial Fractures/complications , Bone Nails , Treatment Outcome
8.
China Journal of Orthopaedics and Traumatology ; (12): 839-845, 2023.
Article in Chinese | WPRIM | ID: wpr-1009146

ABSTRACT

OBJECTIVE@#To investigate the causes of soft tissue complications in patients with dorsal displacement distal radius fractures (DRF) after volar locking plate surgery.@*METHODS@#From July 2016 to May 2021, 112 patients with dorsal displacement DRF were treated with volar locking plate surgery, including 45 males and 67 females. The average age was (46.24±10.08) years old, ranging from 18 to 85 years old. According to whether there were soft tissue complications after operation, they were divided into complication group (40 cases) and non complication group (72 cases). Compared with preoperation, the radial metacarpal inclination and ulnar deflection angle, wrist flexion activity and dorsal extension activity, and grip strength of patients after operation were significantly improved (P<0.05). Compared with the non complication group, the proportion of patients in the complication group whose age was>60 years, body mass index (BMI) more than 30 kg·m-2, smoking, diabetes, fracture type C, open fracture and operation time more than 90 min was higher (P<0.05). The age, BMI, smoking, diabetes, fracture AO classification, fracture type and operation time were analyzed by multifactor Logistic regression to determine the independent risk factors affecting the occurrence of postoperative soft tissue complications of patients, establish a nomogram prediction model, and evaluate the model.@*RESULTS@#At the latest follow-up, the excellent and good rate of wrist joint function recovery was 83.93% (94/112), and the excellent and good rate of fracture reduction was 84.82% (95/112). Multivariate Logistic regression analysis showed that age more than 60 years old, diabetes, fracture type C, open fracture and operation time more than 90 min were independent risk factors for postoperative soft tissue complications (P<0.05). The receiver operating characteristic (ROC), calibration curve and clinical decision curve of the nomogram prediction model showed discrimination, accuracy and validity were good.@*CONCLUSION@#Age more than 60 years, diabetes mellitus, fracture type C, open fracture, and operation time more than 90 min are all independent risk factors for soft tissue complications after DRF volar plate fixation. In clinical treatment, perioperative soft tissue management should be done in such patients to prevent complications.


Subject(s)
Female , Male , Humans , Adult , Middle Aged , Adolescent , Young Adult , Aged , Aged, 80 and over , Wrist Fractures , Fractures, Open , Risk Factors , Wrist Joint/surgery , Metacarpal Bones
9.
Journal of Biomedical Engineering ; (6): 843-851, 2023.
Article in Chinese | WPRIM | ID: wpr-1008908

ABSTRACT

In order to fully explore the neural oscillatory coupling characteristics of patients with mild cognitive impairment (MCI), this paper analyzed and compared the strength of the coupling characteristics for 28 MCI patients and 21 normal subjects under six different-frequency combinations. The results showed that the difference in the global phase synchronization index of cross-frequency coupling under δ-θ rhythm combination was statistically significant in the MCI group compared with the normal control group ( P = 0.025, d = 0.398). To further validate this coupling feature, this paper proposed an optimized convolutional neural network model that incorporated a time-frequency data enhancement module and batch normalization layers to prevent overfitting while enhancing the robustness of the model. Based on this optimized model, with the phase locking value matrix of δ-θ rhythm combination as the single input feature, the diagnostic accuracy of MCI patients was (95.49 ± 4.15)%, sensitivity and specificity were (93.71 ± 7.21)% and (97.50 ± 5.34)%, respectively. The results showed that the characteristics of the phase locking value matrix under the combination of δ-θ rhythms can adequately reflect the cognitive status of MCI patients, which is helpful to assist the diagnosis of MCI.


Subject(s)
Humans , Electroencephalography/methods , Cognitive Dysfunction/diagnosis , Neural Networks, Computer , Sensitivity and Specificity
10.
China Journal of Orthopaedics and Traumatology ; (12): 128-132, 2023.
Article in Chinese | WPRIM | ID: wpr-970833

ABSTRACT

OBJECTIVE@#The relationship between the distal screws and the wrist articular surface was assessed by the additional lateral oblique fluoroscopic view during the operation, and the dorsal tangential view of the wrist was used to observe whether the distal screw penetrated the dorsal cortex, so as to evaluate the clinical efficacy of the volar locking plate in the treatment of distal radius fractures.@*METHODS@#From January 2020 to June 2021, 45 cases of fresh distal radius fractures were treated using the volar Henry's approach, including 20 males and 25 females, aged from 32 to 75 years old with an average of (52.4±8.1) years old. During the operation, they were divided into 2 groups according to the different intraoperative fluoroscopic views:the control group of 20 cases, treated with standard anteroposterior and lateral fluoroscopic view;25 cases in the observation group, additional lateral oblique fluoroscopic view and dorsal tangential view of the wrist were taken. The wrist joint function score and postoperative complications were evaluated at 6 weeks, 3 and 6 months after operation between two groups.@*RESULTS@#All 45 patients were followed up and the duration ranged from 6 to 14 months, with an average of (10.8±1.7) months, all patients achieved bone union and the incision healed well. The incidence of postoperative complications in the observation group was lower than that in the control group, and the difference was statistically significant (P<0.05). In terms of Gartland-Werley score of wrist joint function, the score of wrist function in the observation group was (4.58±1.31) at 6 weeks, (2.98±0.63) at 3 months and (1.95±0.65) at 6 months post-operatively, which were better than those in the control group (6.32±1.96) at 6 weeks, (3.63±0.76) at 3 months and (2.43±0.73) at 6 months. The difference was statistically significant (P<0.05). In the observation group, 7/25 cases(28%) were found to have screw penetration during the operation by additional lateral oblique and dorsal tangential radiograph fluoroscopic views of wrist.@*CONCLUSION@#The addition of lateral oblique and dorsal tangential during the operation could improve the accuracy of distal screw placement, reduce postoperative complications, and achieve early functional exercise.


Subject(s)
Male , Female , Humans , Adult , Middle Aged , Aged , Wrist Fractures , Radius Fractures/surgery , Fracture Fixation, Internal/methods , Fluoroscopy/methods , Bone Plates , Postoperative Complications
11.
China Journal of Orthopaedics and Traumatology ; (12): 116-119, 2023.
Article in Chinese | WPRIM | ID: wpr-970830

ABSTRACT

OBJECTIVE@#To evaluate the clinical outcomes of allogeneic femoral head as strut allograft combined with proximal humeral internal locking system (PHILOS) in the treatment of proximal humeral Neer grade Ⅳ fracture with humeral head collapse.@*METHODS@#From January 2018 to November 2020, 18 patients with Neer grade Ⅳ fracture with humeral head collapse were treated with strut allograft with PHILOS, including 4 males and 14 females, aged from 55 to 78 years old, with an average of (68.11±7.20) years old. The operation time, intraoperative bleeding, postoperative drainage volume, fracture healing time, neck-shaft angle and the height of the humeral head, failure of internal fixation the shoulder function at the last follow-up was assessed using Neer's scoring system.@*RESULTS@#All 18 patients were followed up, and the duration ranged from 10 to 12 months, with an average of (11.08±0.65) months. The operation time was (66.44±5.06) min, the intraoperative bleeding volume was (206.67±36.14) ml, the postoperative drainage volume was (76.11±9.63) ml, and the fracture healing time was (17.28±3.92) weeks. At the last follow-up, the degree of loss of neck-shaft angle was (5.44±0.86) ° and the loss of the height of humeral head was (1.43±0.27) mm. All 18 patients had healing without complications such as fracture, withdrawal, penetration of internal fixation and necrosis of humeral head. According to Neer's evaluation standard, the total score was (89.61±5.60), 10 cases got an excellent result, 6 good, 2 fair.@*CONCLUSION@#Allogeneic femoral head combined with PHILOS is an appropriate treatment for the four-part proximal humerus fractures with humeral head collapse, exhibiting good clinic outcome.


Subject(s)
Male , Female , Humans , Middle Aged , Aged , Humeral Head , Shoulder , Treatment Outcome , Bone Plates , Retrospective Studies , Humerus , Shoulder Fractures/surgery , Fracture Fixation, Internal/adverse effects , Humeral Fractures , Allografts
12.
China Journal of Orthopaedics and Traumatology ; (12): 103-109, 2023.
Article in Chinese | WPRIM | ID: wpr-970828

ABSTRACT

OBJECTIVE@#To explore the clinical outcomes of anteromedial combined with lateral locking plate for complex proximal humeral fractures in the eldery.@*METHODS@#From June 2018 to October 2020, 30 patients who underwent surgical treatment for Neer grade 3 to 4 proximal humeral fractures, including 8 males and 22 females, aged from 51 to 78 years old with an average of (61.5±7.5) years old. Of them, 15 patients had fractures fixed with anteromedial combined with lateral locking plate(ALLP group), whereas 15 received internal fixation with proximal humerus locking plate only(PHLP group). The clinical data, simple shoulder test (SST), humeral head height loss, varus angle and shoulder range of motion were compared between the two groups.@*RESULTS@#All fractures were healed. The follow-up time ranged from 12 to 24 months, with an average of(14.3±2.9) months. The operation time of ALLP group was longer than that of PHLP group (P<0.05). There was no significant difference in intraoperative blood loss between the two groups (P>0.05). There was no significant difference in SST score between the two groups at 1, 3 and 12 months after operation (P>0.05). In terms of radiographic measurement, there was no significant difference in humeral head height loss and varus angle between the two groups at 1 and 3 months after operation (P>0.05). At 12 months after operation, the height loss and varus angle of humeral head in ALLP group were lower than those in PHLP group (P<0.05). In shoulder range of motion, the range of forward elevation in ALLP group was larger than that in PHLP group 1 year after operation(P<0.05). There was no significant difference in external rotation between the two groups.@*CONCLUSION@#Anteromedial combined with lateral locking plate in the treatment of complex proximal humeral fractures in the elderly can increase the stability of the medial column and obtain a good fracture prognosis. But there are also disadvantages such as longer operation time, so it should be individualized according to the fracture type of the patient.


Subject(s)
Male , Female , Humans , Aged , Middle Aged , Treatment Outcome , Shoulder Fractures/surgery , Fracture Fixation, Internal , Shoulder , Humeral Head , Bone Plates , Humeral Fractures/surgery
13.
Article | IMSEAR | ID: sea-218978

ABSTRACT

Background: The treatment of proximal humerus fractures is always a challenge for the Orthopedic surgeon. Proximal humeral fractures are a regular presence in clinics. In the past, the standard treatment method was conserva?ve. The results and func?onal outcomes, on the other hand, were not favorable. The func?onal outcomes have been known to improve a?er the development of locking compression plates. The purpose of this study was to see how func?onal proximal humerus fractures were treated with locking compression plates fared. Methods: This cross-sec?onal interven?onal prospec?ve study was carried out in the Department of Orthopedics, Prathima Ins?tute of Medical Sciences. The study included all adult pa?ents with closed two-part and three-part proximal humerus fractures who were reported within a week a?er the incident. Based on the sample size calcula?ons and inclusion and exclusion criteria a total of n=35 pa?ents were included in the study. Pa?ents were followed up for 12months a?er surgery using a typical surgical method with a locking compression plate. Results: n=35 pa?ents out of which n=19(54.2%) were males and n=16 (45.7%) were females. The distribu?on based on age involved in pa?ents with fractures showed equal preponderance among 31-35 years and 20-25 years with n=9(25.71%).Neer’s classifica?on of fractures of proximal humerus was followed in this study. Most of the pa?ents in n=25 (71.42%) cases were having Neer’s Two-part fractures and three-part fractures were found in n=8(22.8%) and four-part in n=2(5.7%). The overall results in the study were 65.71% of pa?ents had excellent results,20% had good results,8.5% had sa?sfactory results and 5.7% had poor results. Conclusion: Locking plates are a preferable therapeu?c choice for proximal humerus fractures, par?cularly when the bone quality is poor and the fracture is comminuted. Complica?on rates can be reduced by using good surgical techniques and selec?ng the right situa?ons. Proximal humeral internal locking plates con?nue to provide strong overall func?onality.

14.
Rev. cuba. ortop. traumatol ; 36(1)abr. 2022. ilus
Article in Spanish | CUMED, LILACS | ID: biblio-1409042

ABSTRACT

Las fracturas de la diáfisis humeral son lesiones que se producen con frecuencia como parte de caídas o de accidentes de alta energía y se asocian con parálisis del nervio radial. Se presenta paciente de 43 años de edad, masculino, que sufre accidente automovilístico que le produce fractura diafisaria del húmero derecho multifragmentaria, por lo cual se le realiza reducción cerrada y osteosíntesis con clavo intramedular acerrojado y tratamiento conservador para la parálisis radial. La evolución fue satisfactoria, el paciente se recuperó de la parálisis a los 4 meses y logró la consolidación completa a los 5 meses. Tras un año de evolución no presenta dolor en el hombro, y tiene movilidad completa del hombro, muñeca y dedos a la extensión(AU)


Diaphyseal fracture of humerus are frequent lesions, resulting from falls or high energy accidents; they are associated to radial nerve palsy. We report the case of a 43 years old male patient, who suffered a multifragment diaphyseal fracture of his right humerus, as a result of a car accident. He underwent a closed reduction and osteosynthesis using a locking intramedullary nail for the radial paralysis. His evolution was satisfactory; this patient recovered from the paralysis after four months and he managed full consolidation five months later. After a year, he did not have any pain in his shoulder, he has full mobility of his shoulder, wrist and fingers when extendind(AU)


Subject(s)
Humans , Male , Adult , Diaphyses/injuries , Radial Neuropathy/complications , Humeral Fractures/diagnosis , Accidents, Traffic
15.
Malaysian Orthopaedic Journal ; : 46-50, 2022.
Article in English | WPRIM | ID: wpr-934784

ABSTRACT

@#Introduction: Surgical fixation of peri-prosthetic distal femur fractures around knee replacements poses a challenge, especially in frail patients, with variable outcomes reported in the literature. This study looks at the outcomes of a consecutive series of patients presenting with such fractures and treated by using a locking plate fixation. Materials and methods: A total of 21 consecutive patients who were admitted to our trauma unit over 31 months and underwent fixation with the Non-Contact Polyaxial Locking plate system were retrospectively identified and their acute treatment with follow-up outcomes were analysed. Results: The mean age was 81 years and 71% were in ASA grades 3 and 4. Fracture morphologies were classified as per the Su classification, yielding 8 (38%) classified as Su one, 4 (19%) as Su two, and 9 (43%) as Su type three. Postoperatively, 2 patients (9.5%) died due to hospital-acquired pneumonia, and another 2 patients (9.5%) developed wound infections necessitating further return to theatre. Additionally, 2 (9.5%) patients had distal femoral replacements due to non-union. Mean discharge time was 28 days with 12 patients (55% of patients) starting protected weight-bearing six weeks after surgery. Conclusion: The incidence of morbidity, mortality was significant and re-operation was required in patients treated as described, and these were partly attributed to the patient’s average age and the pre-existing comorbidities. Significant variations were noted in the time to discharge, rehabilitation, and time to achieve fracture union. However, the majority of fractures did eventually unite. Patients with comminuted fractures and insufficient bone stock are more likely to progress to non-union and end up requiring revision knee arthroplasty.

16.
Chinese Journal of Orthopaedic Trauma ; (12): 436-441, 2022.
Article in Chinese | WPRIM | ID: wpr-932351

ABSTRACT

Objective:To determine the mechanical properties of our self-designed novel cross-locking intramedullary nails and the impact of number of conical locking nails on the fixation through a finite element analysis and specimen experiments.Methods:Mimics 19.0 and SolidWorks 2014 were used to create transverse fracture models of the olecranon which were subjected to fixation with respectively K-wire tension band (KTB) and our self-designed novel cross-locking intramedullary nails (NIN). The strengths of KTB and NIN fixation were analyzed by Ansys. Fifteen human ulna specimens were used to construct a transverse fracture model of the olecranon; an Instron E10000 mechanical testing machine was used to determine mechanical properties in fixation respectively with KTB, one NIN (NIN-1) and 3 NINs (NIN-3).Results:In the finite element analysis, in simulation of the forearm flexed at 45° under a 100 N load, the deformation of the fracture surface of the olecranon in fixation with KTB, NIN-1 and NIN-3 was respectively 0.131 mm, 0.123 mm and 0.121 mm. In the specimen experiments, in simulation of the forearm flexed at 45°, the maximum failure loads for fixation with KTB, NIN-1 and NIN-3 were (313.38±27.68) N, (528.56±53.58) N and (871.04±94.95) N, respectively, showing significant differences among the 3 groups ( P<0.05). The maximum failure load for NIN-3 fixation was significantly greater than that for KTB or NIN-1 fixation, and the maximum failure load for NIN-1 fixation was significantly greater than that for KTB fixation ( P<0.05). Conclusions:Compared with KTB fixation, NIN fixation is more convenient in operation and has better mechanical properties. NIN-3 fixation has the best mechanical properties.

17.
Chinese Journal of Orthopaedic Trauma ; (12): 380-384, 2022.
Article in Chinese | WPRIM | ID: wpr-932342

ABSTRACT

Objective:To evaluate the biomechanical stability of our slot-designed compression bolt (SCB) combined with bilateral locking compression plates (LCPs) in the treatment of intra-articular distal femur fracture.Methods:In 24 adult male knee specimens treated with formalin, the femoral bony part was preserved to establish standard models of intra-articular distal femur fracture (AO type 33-C1). According to the random number table, the fracture models were divided into 2 equal groups: an experimental group ( n=12) subjected to fixation with one SCB combined with bilateral LCPs with 10 locking screws and a control group ( n=12) subjected to fixation with bilateral LCPs with 12 locking screws. In each model, a vertical ballast test was conducted to record the maximum axial displacement of the system and a horizontal torsion test to calculate the torsional stiffness of the system. When the loading pressure was 0-1,000 N in the biomechanical machine, structural abnormalities were observed in the 2 groups of models and the system maximum axial displacement and system torsional stiffness were compared between the 2 groups. Results:When the vertical ballast pressure was 400 N, 600 N, 800 N and 1,000 N, the maximum axial displacement of the system was, respectively, (0.14±0.01) mm, (0.25±0.01) mm, (0.41±0.02) mm and (0.63 ± 0.02) mm in the experimental group, and (0.15 ± 0.01) mm, (0.26 ± 0.01) mm, (0.46 ± 0.03) mm, and (0.67 ± 0.04) mm in the control group. Compared with the control group, the average maximum axial displacement in the experimental group decreased significantly under the axial pressure of 600-1,000 N ( P<0.05). When the horizontal torsion reached 5°, the torsional stiffness was, respectively, (2.00±0.12) Nm/° and (2.02±0.07) Nm/° in the experimental group and the control group, showing no significant difference between the 2 groups ( P>0.05). Conclusions:In the treatment of intra-articular distal femur fracture, compared with simple bilateral LCPs, our SCB combined with bilateral LCPs demonstrate similar torsional stability but better axial biomechanical stability. As our SCB has advantages of bilateral compression and minimal invasion in operation, it may be a new option for the reduction and compression treatment of intra-articular fractures.

18.
Chinese Journal of Orthopaedic Trauma ; (12): 345-349, 2022.
Article in Chinese | WPRIM | ID: wpr-932336

ABSTRACT

Objective:To explore the risk factors that may affect the stabilization of dorsal intra-articular fragment in distal radius fracture after volar internal fixation.Methods:A retrospective analysis was performed of the patients with distal radius fracture who had been treated by volar internal fixation at Department of Traumatic Orthopedics, Tongji Hospital Affiliated to Tongji University from July 2016 to July 2020. After 3D reconstruction of their preoperative CT scans by software Mimics 20.0, 66 patients with a dorsal intra-articular fragment were screened out. They were 31 males and 35 females, aged from 23 to 78 years (average, 53.4 years). By the AO classification, there were 17 case of type C1, 22 cases of type C2, and 27 cases of type C3. The displacement of dorsal intra-articular fragment was judged by X-ray observation on postoperative day 2 and X-ray follow-up at the outpatient department. The 13 patients with displacement of dorsal intra-articular fragment>2 mm were assigned into a displacement group while the other 53 ones into a displacement-free group. The 2 groups were compared in terms of preoperative general data and anatomical data of the dorsal intra-articular fragment (total preoperative displacement, radius-ulnar length, dorsal-volar length, aspect ratio, proximal-distal length and volume) to analyze the correlations between them and displacement.Results:There was no significant difference in preoperative general data (age, gender, affected side, cause of injury or AO classification) between the 2 groups, showing comparability between groups ( P>0.05). All patients were followed up for 6 to 24 months (mean, 14 months) after surgery. There were no postoperative complications like neurovascular lesion or infection. None of the patients in the displacement group underwent revision surgery, and the fractures healed successfully during the postoperative follow-up. The total preoperative displacement in the displacement group was(10.0±1.3) mm, significantly larger than that in the displacement-free group [(7.8±1.5) mm]; the radius-ulnar length in the displacement group was (8.2±1.3) mm, significantly shorter than that in the displacement-free group [(10.8±2.3) mm]; the aspect ratio of the fragment in the displacement group was 1.2±0.2, significantly lower than that in the displacement-free group (1.4±0.2); the fragment volume in the displacement group was (690.5± 201.4) mm 3, significantly smaller than that in the displacement-free group [(995.8±295.0) mm 3]. There were significant differences in the above items between the 2 groups ( P<0.05). Conclusion:The total preoperative displacement, radius-ulnar length, aspect ratio and volume of a dorsal intra-articular fragment are important factors which may affect the displacement of the dorsal fragment after volar internal fixation.

19.
Chinese Journal of Microsurgery ; (6): 293-297, 2022.
Article in Chinese | WPRIM | ID: wpr-958369

ABSTRACT

Objective:To discuss the clinical effect about the external locking compression plate(LCP) combined with lower abdominal conjoined flap for fixing the open fracture and covering the soft tissue defects on tibia.Methods:From August 2017 to December 2020, 18 patients with serve tibial open fracture were admitted into the trauma center, including 15 males and 3 females with a median age of 38 (ranged, 25-58) years old. The etiology involving: 9 cases by traffic accident, 3 by downfall, 6 by crushing, which classified as type III B( n=6) and III C( n=12) by the Anderson-Gustilo criterion. All wounds were taken radical debridement, fixed by the femur LCP and covered by the VSD during the emergency operation. The lower abdominal conjoined flap was dissected to cover the soft tissue defect, of which the dimension and pedicle length were tailored to the defect. Primary closure was performed on the donor site. Followed-up was conducted by telephone and WeChat. Results:One flap was changed to gastrocnemius myocutaneous flap because of the venous crisis. Seventeen flaps survived completely without significant complications. All the donor and recipient sites had primary healing. A mean follow-up of 15 (ranged, 12 to 18) months. The fracture healed without bone infection and bone nonunion. The aesthetic outcomes were satisfied without overgrown hairy and hyperpigmentation for all flaps. The concealed linear scar was left without hernia or other morbidity on the donor site. At the final follow-up, 12 cases were excellent and 6 cases were good evaluated by the Johner-Wruhs criteria.Conclusion:The external LCP can immobilise the knee and ankle joint with the preservation of the soft tissue, and the free lower abdominal conjoined flap was useful for covering extreme defects with concealed donor site, with enough tissue volume. The combination of both could lower the postoperative infection, reduce the operation time and shorten the hospital stay.

20.
Chinese Journal of Trauma ; (12): 510-516, 2022.
Article in Chinese | WPRIM | ID: wpr-956467

ABSTRACT

Objective:To explore the efficacy of the proximal tibial lateral locking plate with rafting screws combined with Jail screws in the treatment of collapse fracture of the lateral tibial plateau.Methods:A retrospective case series study was performed on clinical data of 36 patients with collapse fracture of the lateral tibial plateau admitted to Suqian Hospital of Nanjing Drum Tower Hospital Group from January 2016 to January 2020, including 19 males and 17 females, aged 34-68 years [(48.6±5.8)years]. Schatzker classification was type II in 28 patients and type III in 8 patients. All patients were treated using the proximal tibial lateral locking plate with raft screws combined with Jail screws. The operation time, intraoperative blood loss and fracture healing were detected. The distance of articular surface collapse of the tibial plateau, posterior inclination angle (PSA) of the tibial plateau, tibial plateau varus angle (TPVA) and Rasmussen anatomical score were compared before operation and at day 2 and 1 year after operation. The Hospital for Special Surgery (HSS) score was used to evaluate knee function at day 2 and 1 year after operation. Complications were also recorded.Results:All patients were followed up for 12-32 months [(19.5±3.1)months]. The operation time was 56-82 minutes [(68.5±9.1)minutes]. The intraoperative blood loss was 40-100 ml [(75.6±10.2)ml]. The fracture was clinically healed by first-stage, with the healing time of 8 to 15 weeks [(12.5±1.3)weeks]. The distance of articular surface collapse of the tibial plateau was improved from (15.5±4.2)mm before operation to (0.7±0.3)mm at day 2 after operation and (1.0±0.2)mm at 1 year after operation (all P<0.01). The PSA was improved from (21.2±2.1)° before operation to (8.9±0.8)° at day 2 after operation and (9.2±0.6)° at 1 year after operation (all P<0.01). The TPA was improved from (100.2±3.7)° before operation to (88.9±1.8)° at day 2 after operation and (87.2±1.6)° at 1 year after operation (all P<0.05). The Rasmussen anatomical score changed from (7.8±1.8)points before operation to (17.1±0.9)points at day 2 after operation and (16.3±0.7)points at 1 year after operation (all P<0.01). There were no significant difference in the distance of articular surface collapse of the tibial plateau, PSA, TPVA and Rasmussen anatomical score at day 2 and 1 year after operation (all P>0.05). The HSS score was (92.8±3.2)points at 1 year after operation, significantly higher than (74.8±3.5) points at day 2 after operation ( P<0.01). Two patients sustained superficial wound infection after operation, which healed after debridement and dressing change. No deep infection occurred. Conclusion:For patients with collapse fracture of the lateral tibial plateau, the proximal tibial lateral locking plate with rafting screws combined with Jail screws can effectively prevent secondary collapse of the articular surface and obtain satisfactory anatomical reduction, good functional recovery and few postoperative complications.

SELECTION OF CITATIONS
SEARCH DETAIL