Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
J Cancer Res Ther ; 2019 May; 15(3): 475-479
Article | IMSEAR | ID: sea-213644

ABSTRACT

Context: Low energy electron beam has been being used widely for superficial cancer treatments. In the current study a design for production of very low energy electron beam, by different thickness of Perspex spoilers, is presented that may be used for skin cancer. Aims: MCNPX Monte Carlo code was used for modeling and simulations in the current study. An energy spoiler Perspex was modeled for degrading 4 MeV electron beam of Varian 2300 CD Linac. Materials and Methods: The thicknesses of 3, 7, and 10 mm were applied before electron applicator at a distance of 42 cm from phantom surface. Dosimetric properties of new electron beams including Rp, Dmax, E0, as well as the penumbra of the beam were investigated. Results: For the 3 mm spoiler, the superficial beam output decreased to 77%, and the Dmax, R90, R50, and RP were shifted to the depths of 4, 6, 9, and 12 mm, respectively. While for 10 mm filter the results were 5.2, 3.0 and 5.0 mm for R90, R50, and Rp, respectively. In addition, the surface dose was 93% and the Dmax was shifted to the depth of 1mm for the 10mm Perspex spoiler slab. Conclusions: The presented beam provides a novel surface dose, Dmax, and RP which can be applicable for treatment of skin cancers with minimum dose to the beyond normal tissues

2.
Korean Journal of Nuclear Medicine ; : 303-310, 2018.
Article in English | WPRIM | ID: wpr-786998

ABSTRACT

PURPOSE: This study aims to compare Monte Carlo-based codes' characteristics in the determination of the basic parameters of a high-resolution single photon emission computed tomography (HiReSPECT) scanner.METHODS: The geometry of this dual-head gamma camera equipped with a pixelated CsI(Na) scintillator and lead hexagonal hole collimator were accurately described in the GEANT4 Application for the Tomographic Emission (GATE), Monte Carlo N-particle extended (MCNP-X), and simulation of imaging nuclear detectors (SIMIND) codes.We implemented simulation procedures similar to the experimental test for calculation of the energy spectra, spatial resolution, and sensitivity of HiReSPECT by using 99mTc sources.RESULTS: The energy resolutions simulated by SIMIND, MCNP-X, and GATE were 17.53, 19.24, and 18.26%, respectively, while it was calculated at 19.15% in experimental test. The average spatial resolutions of the HiReSPECT camera at 2.5 cm from the collimator surface simulated by SIMIND, MCNP-X, and GATE were 3.18, 2.9, and 2.62 mm, respectively, while this parameter was reported at 2.82 mm in the experiment test. The sensitivities simulated by SIMIND, MCNP-X, and GATE were 1.44, 1.27, and 1.38 cps/µCi, respectively, on the collimator surface.CONCLUSIONS: Comparison between simulation and experimental results showed that among these MC codes, GATE enabled to accurately model realistic SPECT system and electromagnetic physical processes, but it required more time and hardware facilities to run simulations. SIMIND was the most flexible and user-friendly code to simulate a SPECT camera, but it had limitations in defining the non-conventional imaging device. The most important characteristics like time and speed of simulation, preciseness of results, and user-friendliness should be considered during simulations.


Subject(s)
Animals , Gamma Cameras , Magnets , Physical Phenomena , Tomography, Emission-Computed, Single-Photon
3.
Radiol. bras ; 46(4): 221-226, Jul-Aug/2013. graf
Article in English | LILACS | ID: lil-684591

ABSTRACT

Objective Comparative analysis of dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for treatment of brain tumors. Materials and Methods Simulations of intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT were performed with the MCNP5 code, modeling the treatment of a brain tumor on a voxel computational phantom representing a human head. Absorbed dose rates were converted into biologically weighted dose rates. Results Intracavitary balloon catheter brachytherapy with I-125 produced biologically weighted mean dose rates of 3.2E-11, 1.3E-10, 1.9E-11 and 6.9E-13 RBE.Gy.h-1.p-1.s, respectively, on the healthy tissue, on the balloon periphery and on the I 1 and I 2 tumor infiltration zones. On the other hand, Cf-252 brachytherapy combined with BNCT produced a biologically weighted mean dose rate of 5.2E-09, 2.3E-07, 8.7E-09 and 2.4E-09 RBE.Gy.h-1.p-1.s, respectively on the healthy tissue, on the target tumor and on the I 1 and I 2 infiltration zones. Conclusion Cf-252 brachytherapy combined with BNCT delivered a selective irradiation to the target tumor and to infiltration zones, while intracavitary balloon catheter brachytherapy with I-125 delivered negligible doses on the tumor infiltration zones. .

4.
Radiol. bras ; 45(5): 267-272, set.-out. 2012. ilus, graf
Article in Portuguese | LILACS | ID: lil-653652

ABSTRACT

OBJETIVO: O presente artigo visa apresentar um estudo dosimétrico comparativo de braquiterapia de próstata com sementes de I-125 e Pd-103. MATERIAIS E MÉTODOS: Um protocolo adotado para ambos os implantes com 148 sementes foi simulado em um fantoma tridimensional heterogêneo de pelve por meio dos códigos SISCODES/MCNP5. Histogramas dose-volume na próstata, bexiga e reto, índices de doses D10, D30, D90, D0,5cc, D2cc e D7cc, e representações de distribuição espacial de dose foram avaliados. RESULTADOS: A atividade inicial de cada semente de I-125, para que D90 seja equivalente à dose de prescrição, foi calculada em 0,42 mCi, e de Pd-103, em 0,94 mCi. A dose máxima na uretra foi 90% e 108% da dose de prescrição para I-125 e Pd-103, respectivamente. A D2cc para I-125 foi 30 Gy no reto e 127 Gy na bexiga, e para Pd-103 foi 29 Gy no reto e 189 Gy na bexiga. A D10 no osso do púbis foi 144 Gy para I-125 e 66 Gy para Pd-103. CONCLUSÃO: Os resultados indicam que os implantes de Pd-103 e I-125 puderam depositar a dose prescrita no volume alvo. Entre os achados, observou-se excessiva exposição de radiação nos ossos da pelve, principalmente no protocolo com I-125.


OBJECTIVE: The present paper is aimed at presenting a comparative dosimetric study of prostate brachytherapy with I-125 and Pd-103 seeds. MATERIALS AND METHODS: A protocol for both implants with 148 seeds was simulated on a heterogeneous three-dimensional pelvic phantom by means of the SISCODES/MCNP5 codes. Dose-volume histograms on prostate, rectum and bladder, dose indexes D10, D30, D90, D0.5cc, D2cc and D7cc, and representations of the spatial dose distribution were evaluated. RESULTS: For a D90 index equivalent to the prescription dose, the initial activity of each I-125 seed was calculated as 0.42 mCi and of Pd-103 as 0.94 mCi. The maximum dose on the uretra was 90% and 108% of the prescription dose for I-125 and Pd-103, respectively. The D2cc for I-125 was 30 Gy on the rectum and 127 Gy on the bladder; for Pd-103 was 29 Gy on the rectum and 189 Gy on the bladder. The D10 on the pubic bone was 144 Gy for I-125 and 66 Gy for Pd-103. CONCLUSION: The results indicate that Pd-103 and I-125 implants could deposit the prescribed dose on the target volume. Among the findings of the present study, there is an excessive radiation exposure of the pelvic bones, particularly with the I-125 protocol.


Subject(s)
Humans , Male , Antineoplastic Protocols , Brachytherapy/methods , Dosimetry , Therapy, Computer-Assisted , Prostatic Neoplasms , Radiotherapy
5.
Bulletin of The Academy of Military Medical Sciences ; (6): 43-45, 2010.
Article in Chinese | WPRIM | ID: wpr-643038

ABSTRACT

Objective To construct a voxel mouse model combining with Monte Carlo method used for radiation dose calculation.Methods A set of slice images obtained from a nude male mouse (28 g) was utilized, all slice images were registered,some organs or tissues were identified, segmented and filled with specific color, and finally the physical property was defined by MCNP application.Results A mouse model with a voxel size of 0.2 mm×0.2 mm×0.2 mm, consisting of 14 organs or tissues,was constructed, which could satisfy the requirement of precision for radiation dose distribution calculation and moderate computing time.Conclusion The voxel mouse model can be used to calculate the quantity of ionization radiation dosimetry in related areas including radiological medicine, nuclear medicine and space radiation medicine.

6.
Radiol. bras ; 41(6): 403-407, nov.-dez. 2008. graf, tab
Article in Portuguese | LILACS | ID: lil-507124

ABSTRACT

OBJETIVO: Avaliar a dose absorvida em folículos tireoidianos devido aos elétrons de baixa energia, como oselétrons Auger e os de conversão interna, além das partículas beta, para os radioisótopos de iodo (131I, 132I,133I, 134I e 135I) usando o método Monte Carlo. MATERIAIS E MÉTODOS: O cálculo da dose foi feito ao nível folicular, simulando elétrons Auger, conversão interna e partículas beta, com o código MCNP4C. Os folículos (colóide e células foliculares) foram modelados como esferas, com diâmetros do colóide variando de 30 a 500 μm. A densidade considerada para os folículos foi a da água (1,0 g.cmû³). RESULTADOS: Considerando partículas de baixa energia, o percentual de contribuição do 131I na dose total absorvida pelo colóide é de aproximadamente 25%, enquanto os isótopos de meia-vida física curta apresentaram contribuição de 75%. Para as células foliculares, esse percentual é ainda maior, chegando a 87% para os iodos de meia-vida curtae 13% para o 131I. CONCLUSÃO: Com base nos resultados obtidos, pode-se mostrar a importância de se considerar partículas de baixa energia na contribuição para a dose total absorvida ao nível folicular (colóide e células foliculares) devido aos radioisótopos de iodo (131I, 132I, 133I, 134I e 135I).


OBJECTIVE: To evaluate the absorbed dose in thyroid follicles due to low-energy electrons such as Auger and internal conversion electrons, besides beta particles, for iodine radioisotopes (131I, 132I, 133I, 134I and 135I)utilizing the Monte Carlo method. MATERIALS AND METHODS: The dose calculation was performed at follicularlevel, simulating Auger, internal conversion electrons and beta particles, with the MCNP4C code. The follicles(colloid and follicular cells) were modeled as spheres with colloid diameter ranging from 30 to 500 μm, and with the same density of water (1.0 g.cmû³). RESULTS: Considering low-energy particles, the contributionof 131I for total absorbed dose to the colloid is about 25%, while the contribution due to short-lived isotopesis 75%. For follicular cells, this contribution is still higher achieving 87% due to short-lived iodine and 13%due to 131I. CONCLUSION: The results of the present study demonstrate the importance of considering lowenergyparticles in the contribution for the total absorbed dose at follicular level (colloid and follicular cells) due to iodine radioisotopes (131I, 132I, 133I, 134I and 135I).


Subject(s)
Iodine/administration & dosage , Thyroid Neoplasms/diagnosis , Clinical Laboratory Techniques , Colloids , Dosimetry , Monte Carlo Method
7.
The Journal of the Korean Society for Therapeutic Radiology and Oncology ; : 158-166, 2003.
Article in English | WPRIM | ID: wpr-13188

ABSTRACT

PURPOSE: To propose a conceptual design of a novel source for intensity modulated brachytherapy. MATERIALS AND METHODS: The source design incorporates both radioactive and shielding materials (stainless steel or tungsten), to provide an asymmetric dose intensity in the azimuthal direction. The intensity modulated intravascular brachytherapy was performed by combining a series of dwell positions and times, distributed along the azimuthal coordinates. Two simple designs for the beta-emitting sources, with similar physical dimensions to a 90Sr/Y Novoste Beat-Cath source, were considered in the dosimetric feasibility study. In the first design, the radioactive and materials each occupy half of the cylinder and in the second, the radioactive material occupies only a quater of the cylinder. The radial and azimuthal dose distributions around each source were calculated using the MCNP Monte Carlo code. RESULTS: The preliminary hypothetical simulation and optimization results demonstrated the 87% difference between the maximum and minimum doses to the lumen wall, due to off-centering of the radiation source, could be reduced to less than 7% by optimizing the azimuthal dwell positions and times of the partially shielded intravascular brachytherapy sources. CONCLUSION: The novel brachytherapy source design, and conceptual source delivery system, proposed in this study show promising dosimetric characteristics for the realization of intensity modulated brachytherapy in intravascular treatment. Further development of this concept will center on building a delivery system that can precisely control the angular motion of a radiation source in a small-diameter catheter.


Subject(s)
Brachytherapy , Catheters , Feasibility Studies , Steel
8.
The Journal of the Korean Society for Therapeutic Radiology and Oncology ; : 66-73, 2001.
Article in Korean | WPRIM | ID: wpr-76512

ABSTRACT

PURPOSE: For the research of Boron Neutron Capture Therapy (BNCT), fast neutrons generated from the MC-50 cyclotron with maximum energy of 34.4 MeV in Korea Cancer Center Hospital were moderated by 70 cm paraffin and then the dose characteristics were investigated. Using these results, we hope to establish the protocol about dose measurement of epi-thermal neutron, to make a basis of dose characteristic of epi-thermal neutron emitted from nuclear reactor, and to find feasibility about accelerator-based BNCT. METHOD AND MATERIALS: For measuring the absorbed dose and dose distribution of fast neutron beams, we used Unidos 10005 (PTW, Germany) electrometer and IC-17 (Far West, USA), IC-18, EIC-1 ion chambers manufactured by A-150 plastic and used IC-17M ion chamber manufactured by magnesium for gamma dose. There chambers were flushed with tissue equivalent gas and argon gas and then the flow rate was 5 cc per minute. Using Monte Carlo N-Particle (MCNP) code, transport program in mixed field with neutron, photon, electron, two dimensional dose and energy fluence distribution was calculated and there results were compared with measured results. RESULTS: The absorbed dose of fast neutron beams was 6.47x10-3 cGy per 1 MU at the 4 cm depth of the water phantom, which is assumed to be effective depth for BNCT. The magnitude of gamma contamination intermingled with fast neutron beams was 65.2+/-0.9% at the same depth. In the dose distribution according to the depth of water, the neutron dose decreased linearly and the gamma dose decreased exponentially as the depth was deepened. The factor expressed energy level, D20/D10, of the total dose was 0.718. CONCLUSION: Through the direct measurement using the two ion chambers, which is made different wall materials, and computer calculation of isodose distribution using MCNP simulation method, we have found the dose characteristics of low fluence fast neutron beams. If the power supply and the target material, which generate high voltage and current, will be developed and gamma contamination was reduced by lead or bismuth, we think, it may be possible to accelerator-based BNCT.


Subject(s)
Argon , Bismuth , Boron Neutron Capture Therapy , Boron , Cyclotrons , Electric Power Supplies , Fast Neutrons , Hope , Korea , Magnesium , Neutrons , Nuclear Reactors , Paraffin , Plastics , Water
SELECTION OF CITATIONS
SEARCH DETAIL