Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Chinese Journal of Ocular Fundus Diseases ; (6): 835-839, 2022.
Article in Chinese | WPRIM | ID: wpr-958532

ABSTRACT

Objective:To observe the changes of macular microvascular structure and macular pigment density (MPOD) in eyes with macular edema (ME) secondary to retinal vein occlusion (RVO), and preliminarily analyze their correlation.Methods:A prospective clinical study. A total of 62 eyes of 62 patients with monocular RVO secondary ME (RVO-ME) diagnosed in the Ophthalmology Hospital of Xi'an No.1 Hospital from July 2020 to May 2021 were included in this study. There were 33 males with 33 eyes, 29 females with 29 eyes. The age was 58.30±12.15 years. The course of disease from the onset of symptoms to medical treatment was 12.29±7.65 days. All patients underwent best corrected visual acuity (BCVA), optical coherence tomography angiography (OCTA) and MPOD test. BCVA examination was performed using a standard logarithmic visual acuity chart, which was converted to logarithm of minimum angle of resolution (logMAR). The vascular density (VD), vascular skeletal density (SD), foveal avascular area (FAZ) and central macular thickness (CMT) of the superficial retinal capillary plexus (SCP) in the range of 3 mm×3 mm in the macular area of bilateral eyes were measured by OCTA. MPOD was measured by heterochromatic scintillation photometry. Bilateral eyes passed examination in 37 cases. The eyes of 25 patients failed to pass the test. The changes of macular VD, SD, FAZ area, CMT and MPOD between the affected eyes and the contralateral eyes were compared. The MPOD of the affected eye and the contralateral eye was compared by paired t test. FAZ area, CMT, VD, SD, and logMAR BCVA were tested by paired Wilcoxon signed rank sum test. Spearman rank correlation test was used to analyze the correlation between macular blood flow density (VD, SD) and foveal morphology (FAZ area, CMT) with logMAR BCVA and MPOD. Results:Compared with contralateral eyes, VD ( Z=-5.981) and SD ( Z=-6.021) were decreased, FAZ area ( Z=-2.598) and CMT ( Z=-6.206) were increased, and the differences were statistically significant ( P<0.05). In 37 patients who passed MPOD test in bilateral eyes, the MPOD value of the affected eye was lower than that of the contralateral eye, and the difference was statistically significant ( t=-2.930, P<0.05). Compared with the affected eye which failed to pass the MPOD detection, macular VD ( Z=-2.807) and SD ( Z=-2.460) were increased, FAZ area ( Z=-4.297) and CMT ( Z=-3.796) were decreased in the affected eye which passed the MPOD test, and the differences were statistically significant ( P<0.05). Correlation analysis showed that logMAR BCVA in the affected eye was negatively correlated with macular VD and SD ( r=-0.298, -0.461; P<0.05), which was positively correlated with FAZ area and CMT ( r=0.487, 0.789; P<0.05). MPOD in the affected eye was negatively correlated with logMAR BCVA ( r=-0.344, P<0.05). MPOD in the contralateral eye was positively correlated with CMT ( r=0.358, P<0.05). Conclusions:The VD and SD of macular SCP are decreased, FAZ area is enlarged, CMT is thickened, and MPOD is decreased in RVO-ME eyes. MPOD is negatively correlated with logMAR BCVA.

2.
Journal of Korean Medical Science ; : 30-2020.
Article in English | WPRIM | ID: wpr-782506

ABSTRACT

50 years) showed lower MPOD than younger (30–49 years) subjects. But, in the healthy population, the estimated MPOD values exhibited a decreasing trend with age, but there were no significant differences according to age, after excluding patients with AMD. MPOD was significantly lower in patients with AMD than in aged healthy controls. Furthermore, hypertension, dyslipidemia, and smoking were identified as risk factors for AMD.CONCLUSION: MPOD measured with MPSII® reflects the MP density in healthy individuals and patients with dry AMD. Aging was not significantly associated with low MPOD in healthy population, but the presence of dry AMD was significantly associated with low MPOD. Then, low MPOD may be a risk factor for development of dry AMD. Furthermore, routine screening with MPS II® for ages 50 and older is thought to help detect early low MPOD and identify individuals who should take supplements.


Subject(s)
Humans , Aging , Dyslipidemias , Healthy Volunteers , Hypertension , Linear Models , Logistic Models , Macular Degeneration , Macular Pigment , Mass Screening , Methods , Photometry , Retrospective Studies , Risk Factors , Smoke , Smoking
3.
Philippine Journal of Ophthalmology ; : 88-95, 2020.
Article in English | WPRIM | ID: wpr-978895

ABSTRACT

Objective@#To evaluate the efficacy of oral lutein supplementation on macular pigment optical density (MPOD) levels and macular function in pseudophakic eyes that underwent phacoemulsification. @*Methods@#This was a prospective, randomized, parallel-arm, single-masked study comparing oral lutein supplement 20 mg/tablet (Lutax 20) with non-supplementation in pseudophakic eyes. We assessed MPOD, low-luminance deficit (LLD), visual recovery time (VRT) using photostress test, and adverse events. One hundred twenty-eight (128) eyes were enrolled and randomized 1:1 to active treatment (lutein supplementation) or no treatment (no supplementation). The supplementation period was 12 weeks and patients were assessed every 4 weeks over a period of 16 weeks.@*Results@#Sixty-four (64) eyes in each group completed the study. A significant increase in MPOD (p<0.001) was observed in the lutein supplemented group, from 0.36 DU at baseline to 0.55 DU at week 12, with a mean increase of 6.32 ± 1.72% per 4 weeks of supplementation compared with a mean MPOD decrease rate of 0.63 ± 0.48% in the non-supplementation group. A significant reduction in LLD was observed in the lutein-treated group, from LogMAR 0.063 at baseline to LogMAR 0.023 at Week 12 (p=0.003). VRT was also significantly shorter in the treatment from a baseline of 83.06 to 68.80 seconds at Week 12 (p<0.001).@*Conclusion@#Lutein supplementation (20 mg/tablet; Lutax 20) demonstrated a significant degree of MPOD augmentation, and reductions in LLD and VRT among patients who underwent phacoemulsification with lens implantation.


Subject(s)
Lutein , Dietary Supplements
4.
International Eye Science ; (12): 1621-1624, 2020.
Article in Chinese | WPRIM | ID: wpr-823404

ABSTRACT

@#AIM: To investigate the change of macular pigment optical density(MPOD)in the patients of obstructive sleep apnea-hypopnea syndrome(OSAHS). <p>METHODS: Totally 70 OSAHS patients as observation group and 32 healthy subjects as control group with their right eyes were enrolled from Chongqing Emergency Medical Center during January to December of 2019. All the subjects used Visucam 200 to measure the mean/max MPOD. <p>RESULTS: Both mean/max MPOD(0.0916±0.0149, 0.2675±0.0419Log unit)of OSAHS group are significantly lower than the control group(0.1193±0.0159, 0.3235±0.0400Log unit, <i>P</i><0.001).There are significant difference of mean/max MPOD between mild(<i>n</i>=12)/moderate(<i>n</i>=17)/severe(<i>n</i>=41)groups divided by AHI(<i>P</i><0.001). The increasing severity of OSAHS lead to lower mean/max MPOD.Furthermore there is negative correlation between mean/max MPOD and AHI(<i>r</i>=-0.685, -0.492; <i>P</i><0.001).<p>CONCLUSION: Our study results suggest that the mean/max MPOD were reduced in the patients of OSAHS. Moreover, the decreased degree of mean/max MPOD is positively related to the severity of OSAHS. It shows that the MPOD of OSAHS have already changed before they feel the significant syndrome. The reducing of MPOD may cause dysfunction of macular and finally rise up to macular disease.

5.
International Eye Science ; (12): 709-713, 2019.
Article in Chinese | WPRIM | ID: wpr-735186

ABSTRACT

@#AIM: To determine the relationship among the macular pigment optical density(MPOD), central macular thickness and body mass index(BMI).<p>METHODS: This is a comparative cross-sectional study performed in a single institution. Totally 210 volunteers who met the inclusion criteria were included in this study. The subject's MPOD was measured using Macula Pigment Screener II(MPS II, by Electron Technology). Central macular thickness was measured with Spectral Domain Cirrus Optical Coherence Tomography(OCT), Cirrus(Model 4000, Carl Zeiss Meditec). The information of both MPOD and OCT from both eyes were recorded. The data was analysed using Microsoft© Excel \〖Version 15.12.3(150724)℃2015 Microsoft\〗, SPSS(IBM© SPSS© Statistics Version 2.2), and R(version 3.2.1; R Core Team 2015).<p>RESULTS: There was significant positive correlation between MPOD and central macular thickness(<i>r</i>=0.42, <i>P</i><0.01)and a significant negative correlation between MPOD and BMI(<i>r</i>=-0.23, <i>P</i><0.01).<p>CONCLUSION: Our study showed a significant positive correlation between MPOD and central macular thickness. Further study is needed to look at the detailed structure of the fovea and its relationship with MPOD. Our study also found a significant negative correlation between MPOD and BMI, suggesting that a reduction in BMI may increase the density of macula pigment, which can be helpful in preventing age-retinal pigment epitheliitis(ARMD).

6.
Philippine Journal of Ophthalmology ; : 93-96, 2015.
Article in English | WPRIM | ID: wpr-998937

ABSTRACT

Objective@#To determine the range of macular pigment optical density (MPOD) levels in healthy Filipino adults using both the MPS II and the macuscope and to investigate whether age and sex were related to inter-subject variations in MPOD.@*Methods@#This was a prospective, cross sectional study of 168 healthy Filipino patients who underwent heterochromic filter photometry to measure macular pigment levels using the MPS II and the macuscope. The MPOD levels were averaged per age group and analyzed as to variations among age and gender.@*Results@#One hundred thirty (130) and thirty-eight (38) patients underwent MPS II and macuscope testing respectively. The mean MPOD level for MPS II was 0.39(±0.16) and for macuscope 0.27(±0.07). MPOD values were similar across all age groups and gender, but they were lower when measured with the macuscope.@*Conclusions@#MPOD levels measured among healthy Filipino adults were lower with the macuscope compared to the MPS II. These differences should take into consideration the differences in apparatus and techniques of measurement.


Subject(s)
Macular Degeneration , Zeaxanthins
SELECTION OF CITATIONS
SEARCH DETAIL