Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Odovtos (En linea) ; 25(1)abr. 2023.
Article in English | LILACS, SaludCR | ID: biblio-1422193

ABSTRACT

The aim of this in vitro study was to evaluate the biomechanical and chemical behavior of various bioactive materials in class II MOD restorations. Forty- eight standardized class II MOD cavities were prepared in sound extracted human molar teeth. The specimens were divided into four groups according to the restorative material: Group 1 (Filtek™ Z350 XT), Group 2 (Biodentine™ as a liner, and then restored with Filtek™ Z350 XT), Group 3 (Cention N™), and Group 4 (Activa™ Bioactive-Restorative). The samples were tested for fracture resistance by subjecting them to a compressive load in a Universal testing Machine. The failure modes of each specimen were evaluated. The alkalinizing potential and calcium ion release of the materials were measured. SEM-EDAX analyses were also performed for all materials. Data were analyzed using ANOVA and post hoc Tukey test (p<0.05). Group 1 showed the higher fracture resistance (p<0.05). Group 3 had greater fracture resistance values but no statistical difference from Group 4. Biodentine™ showed greater biomineralization potential. Class II MOD restorations of Group 1 displayed the higher fracture resistance; however, it was highly associated with catastrophic failure. Conversely, Biodentine™ presented a more significant bioactivity potential, and its use, as in Group 2, promoted the most favorable failure mode.


El objetivo de este estudio, in vitro, fue evaluar el desempeño biomecánico y químico de varios materiales bioactivos en restauraciones clase II MOD. Se prepararon cuarenta y ocho cavidades clase II MOD estandarizadas en dientes molares humanos extraídos. Las muestras se dividieron en cuatro grupos según el material de restauración: Grupo 1 (Filtek™ Z350 XT), Grupo 2 (Biodentine™ como base y luego restaurado con Filtek™ Z350 XT), Grupo 3 (Cention N™) y Grupo 4 (Activa™ Bioactivo-Reparador). La prueba de resistencia a la fractura fue realizada en una máquina de ensayo universal Instron. Se evaluaron los modos de falla de cada espécimen. Se midió el pH y la liberación de iones de calcio de los materiales. Se realizaron análisis SEM-EDAX. Los datos se analizaron mediante ANOVA y la prueba post hoc de Tukey (p<0,05). El grupo 1 mostró la mayor resistencia a la fractura (p<0,05). El Grupo 3 tuvo mayores valores de resistencia a la fractura que el Grupo 4, pero sin diferencia estadística. Biodentine™ mostró un mayor potencial de biomineralización. Las restauraciones Clase II MOD del Grupo 1 mostraron la mayor resistencia a la fractura; sin embargo, estuvo altamente asociado con fallas irreparables. Por el contrario, Biodentine™ presentó un potencial de bioactividad más significativo y su uso, como en el Grupo 2, promovió el modo de falla más favorable.


Subject(s)
Biomedical and Dental Materials/analysis , Composite Resins/analysis , Flexural Strength
2.
Rev. Asoc. Odontol. Argent ; 106(3): 80-85, sept. 2018. ilus
Article in Spanish | LILACS | ID: biblio-964218

ABSTRACT

Objetivos: Evaluar la utilidad de un modelo animal mamífero como la cabra, a fin de estudiar biomateriales indicados para protección pulpar directa. Materiales y métodos: Bajo anestesia general, se realizaron exposiciones pulpares en las caras vestibulares de los ocho incisivos inferiores de cuatro (n=4) cabras de raza criolla. En cada animal, 6 (n=6) exposiciones fueron protegidas con un material experimental (ACPc), y las 2 (n=2) restantes, con un material de control a base de MTA (WMTA). En total se realizaron 24 (n=24) protecciones con ACPc y 8 (n=8) con WMTA. Las cabras fueron separadas en dos grupos de dos (n=2) animales cada uno. Bajo anestesia general, los dientes se extrajeron a los 30 (Grupo 1) y 60 días (Grupo 2), se fijaron en formol búffer fosfato al 10% y se procesaron para el estudio histológico de rutina. Los animales no fueron sacrificados. En cada período, se analizaron 12 (n=12) protecciones pulpares con ACPc y 4 (n=4) con WMTA. Resultados: Grupo 1: Once (n=11) pulpas protegidas con ACPc presentaron puente dentinario completo e inflamación crónica remanente. En un caso no hubo puente dentinario y la pulpa estaba crónicamente inflamada. Las 4 (n=4) pulpas protegidas con WMTA presentaron puente dentinario e inflamación crónica. Grupo 2: Las 12 (n=12) pulpas protegidas con ACPc se encontraban normales, con puente dentinario completo, buena irrigación y capa de odontoblastos continua. Las 4 (n=4) pulpas protegidas con WMTA revelaron condiciones similares. Los resultados se analizaron mediante el test de probabilidad exacta de Fischer (P<0,05). Con respecto al factor inflamación, hubo diferencias significativas (P<0,001) entre los resultados obtenidos a 30 y 60 días, pero no hubo diferencias entre ACPc y WMTA (P>0,05) dentro de cada uno de los períodos de observación. En cuanto a la presencia de puente dentinario, no hubo diferencias significativas (P>0,05) entre ACPc y WMTA en ambos períodos de observación. Conclusiones: Los resultados sugieren que la cabra constituye un modelo animal adecuado para los ensayos de protección pulpar directa (AU)


Aim: To evaluate the suitability of the goat as an animal model for the study of biomaterials indicated for direct pulp capping. Materials and methods: Under general anaesthesia, pulp exposures were performed on the buccal surfaces of the eight mandibular incisors of four (n=4) healthy Creole goats. The exposures were capped with two biomaterials developed for PPD. In each animal, 6 (n=6) exposures were capped with an experimental material (ACPc) while for the remaining 2 (n=2) exposures a white MTA (WMTA) was used as the control. A total of 24 (n=24) direct pulp capping with ACPc and 8 (n=8) with WMTA were done. The goats were separated into two groups of two (n=2) animals each. The teeth were extracted after 30 days (Group 1) and 60 days (Group 2) and fixed in 10% phosphate buffered formalin and processed for routine histology. The animals were not euthanized. In each period, 12 (n=12) PPD with ACPc and 4 (n=4) with WMTA were analyzed. Results: Group 1: Eleven (n=11) pulps capped with ACPc showed complete dentin bridges and chronic inflammation. In one case without dentin bridges the pulp was chronically inflamed. The four pulps capped with WMTA revealed the presence of dentin bridges and chronic inflammation. Group 2: Twelve pulps protected with ACPc showed a complete dentin bridges. In addition, well irrigated and healthy pulp tissues along with a continuous odontoblast palisade were observed. The four pulps capped with WMTA revealed similar features. In cases showing dentin bridges, a few numbers of empty spaces as well as odontoblast like cell inclusions were detected. The results were analyzed by the Fisher's exact test (P<0.05). With respect to the inflammation factor there were significant differences between the 30 and 60-day observation periods (P<0.001), but no differences were observed between ACPc and WMTA (P>0.05) within each of the observation periods. When the presence or absence of a dentin bridges was analyzed, no significant differences (P>0.05) were found between materials at each observation period. Conclusions: The results suggest that the goat seems to be an appropriate animal model for direct pulp capping evaluation (AU)


Subject(s)
Animals , Biocompatible Materials , Dental Pulp , Dental Pulp Capping , Goats , Models, Animal
3.
Rev. Asoc. Odontol. Argent ; 105(3): 102-108, sept. 2017. ilus, tab
Article in Spanish | LILACS | ID: biblio-973104

ABSTRACT

Objetivos: Comparar la biocompatibilidad y la actividadosteogénica del material bioactivo experimental Activa PC y de MTA color blanco, por medio de un modelo de implantación en tibia de rata.Materiales y métodos: En las tibias de 20 (n=20) ratas Wistar macho de aproximadamente 350 gramos, seimplantaron tubos de silicona estériles obturados a ras con Activa PC (Pulpdent Corp., Watertown, Estados Unidos) o MTA (Angelus, Londrina, Brasil). Los animales se separaronen dos grupos de 10 (n=10). La eutanasia de uno de los grupos fue realizada a los 15 días, mientras que la del grupo restante se realizó a los 60 días posimplantación. Las tibiasfueron removidas, se fijaron en formol-buffer al 10 por ciento, y se descalcificaron y procesaron para su estudio histológico. La evaluación fue realizada en base a tres categorías, y los resultados se analizaron por medio de la prueba de Wilcoxon y el test no paramétrico de Mann-Whitney, con un nivel de significación de P0,05) entre Activa PC y MTA Angelus en cada uno de los períodos de observación, pero sí las hubo (P<0,05) cuando se compararon los resultados obtenidosa 15 y 60 días. Conclusiones: Activa PC y MTA Angelus se comportaron como materiales biocompatibles en tibias de rata, y su función bioactiva se incrementó significativamente en función del tiempo transcurrido, favoreciendo ambos materialesel proceso de reparación ósea.


Subject(s)
Animals , Rats , Biocompatible Materials , Root Canal Filling Materials/classification , Osteogenesis/physiology , Materials Testing , Data Interpretation, Statistical , Histological Techniques
SELECTION OF CITATIONS
SEARCH DETAIL