Chinese Journal of Radiological Health ; (6): 592-596, 2021.
Article in Chinese | WPRIM | ID: wpr-974658

ABSTRACT

Objective By measuring the induced radioactivity of the medical electron linear accelerator, and analyzing the measuring results and the measuring process, the cooling law of the induced radioactivity was studied, to provide basic data for evaluating additional doses to patients, medical staff and the public. Methods Five Medical Electron Linear accelerators were used to measure the induced radioactivity by using automes-6150AD6/H+6150AD-b/H x-γ radiation peripheral dose equivalent rate meter for environmental monitoring. Results The level of induced radioactivity of 5 medical electron linear accelerators is related to the factors such as measuring position and time: 10 second after the end of beam output, the maximum dose equivalent rate is 5.55 μSv/h around 5 cm on the surface of the head housing of the accelerator, and the maximum ambient dose equivalent rate at 1 m from the fixed point of the housing is 4.07 μSv/h, 5 minutes after the end of output, the maximum dose equivalent rate is 2.11 μSv/h around the 5 cm surface and 1.77 μSv/h around the 1 m fixed point. Conclusion The measured radioactivity induced by the medical electron linear accelerator gradually cools over time, the measurement valuesare maintained in a relatively fixed range, and the fluctuation range of the values is narrow.

2.
International Journal of Biomedical Engineering ; (6): 173-176, 2017.
Article in Chinese | WPRIM | ID: wpr-617964

ABSTRACT

Objective To evaluate the radiation protection of occupational hazards in a hospital Clinac 23EX medical electronic accelerator construction project so as to ensure the health and safety of the relevant people involved.Methods According to the relevant laws,regulations and standards of China,combined with the relevant materials provided by the construction unit,the radiation protection tests and comprehensive assessment of this project were carried out.Results The performance test results of the medical electron accelerator met the requinements of GB/T 19046-2013 The ambient dose equivalent rate in the workplace was between the background dose rate (0.10 μ,Sv/h) and 11.5 μSv/h,which suggested the computer room shielding met the requirements of radiation protection.The total body effective dose,the for 7 radiation workers were 0.85,1.19,1.64 mSv,respectively,which were lower than the dose management control values of the construction unit and the national standards.Radiation protection supplies and the management system of the construction unit met the national requirements.Conclusions The construction project can effectively control the radioactive occupational hazard factors in normal operation,and the radiation protection facilities have reached the completion requirements.

SELECTION OF CITATIONS
SEARCH DETAIL