Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Yonsei Medical Journal ; : 222-226, 2009.
Article in English | WPRIM | ID: wpr-202317

ABSTRACT

PURPOSE: To investigate the reliability of intra-atrial electrocardiogram (ECG) use for external jugular vein (EJV) catheterization. MATERIALS AND METHODS: Patients undergoing open heart surgery in Suleyman Demirel University Hospital between February and June 2006 were included in the study. Using a sterile Seldinger technique, a triple lumen polyurethane central venous catheter was introduced (Certofix(R) Trio V 720, length 20 cm, 7 French) under intra-atrial ECG guidance. The presence of an increase in P-wave size was recorded. Just after the surgery, a portable chest X-ray was taken. The method was considered to be successful when a change in P-wave could be seen and the catheter was in the superior vena cava, as well as when there was no change in P-wave and the catheter was not in the superior vena cava. RESULTS: In six patients (12%), we were not able to advance the guidewire. In the remaining 44 patients, the catheter was inserted without problem. Eight of these 44 catheters were positioned in the innominate vein, with a malposition ratio of 18%. The success rate of external jugular vein cannulation with intra-atrial ECG was 95%. No complications occured related to the EJV cannulation. CONCLUSION: Considering that it is easily accessed without complication, and the malposition is successfully detected by intra-atrial ECG, EJV is a suitable access for central venous cannulation when internal jugular vein (IJV) is not usable.


Subject(s)
Female , Humans , Male , Middle Aged , Catheterization, Central Venous/methods , Electrocardiography/methods , Jugular Veins
2.
Korean Journal of Anesthesiology ; : 220-228, 2001.
Article in Korean | WPRIM | ID: wpr-72434

ABSTRACT

BACKGROUND: Severe cardiac arrhythmia after accidental intravascular injection of bupivacaine in the practice of regional anesthesia has been reported and is known to be difficult to treat. We evaluated the electrocardiographic and hemodynamic changes during recovery from bupivacaine-induced cardiac toxicity. METHODS: In eight male dogs receiving pentobarbital, after baseline recordings were obtained, 0.5% bupivacaine was infused at a rate of 0.5 mg/kg/min intravenously until cardiac output decreased to 50% or less(1/2 CO), which was defined as the point of cardiac depression in this study. The hemodynamic and electrocardiographic parameters were recorded at 1/2 CO, and 5, 10, 15, 20, 30 and 40 min after 1/2 CO. The following electrocardiographic parameters were measured: duration of QRS complex and T wave, PR interval and the corrected QT interval, all determined on the lead II. RESULTS: Mean arterial pressure was significantly decreased throughout the experimental period after 1/2 CO, and cardiac output and SO2 were significantly decreased until 20 min after 1/2 CO in comparison with those at baseline. All dogs had serious changes on the ECG. Heart rate and ECG changes returned to baseline within 20 min after 1/2 CO, but QRS duration remained increased until 30 min after 1/2 CO. Systemic vascular resistance, pulmonary vascular resistance and serum electrolytes were not changed with time. CONCLUSIONS: In the absence of hypoxia, acidosis, and hyperkalemia, QRS duration returned to control values more slowly than other variables on the EKG after bupivacaine cardiac toxicity. MAP and PCWP recovered the slowest of all hemodynamic variables.


Subject(s)
Animals , Dogs , Humans , Male , Acidosis , Anesthesia, Conduction , Hypoxia , Arrhythmias, Cardiac , Arterial Pressure , Bupivacaine , Cardiac Output , Depression , Electrocardiography , Electrolytes , Heart Rate , Hemodynamics , Hyperkalemia , Pentobarbital , Vascular Resistance
SELECTION OF CITATIONS
SEARCH DETAIL