1.
Arq. odontol ; 54: 1-8, jan.-dez. 2018. ilus, graf
Article in English | LILACS, BBO | ID: biblio-996747

ABSTRACT

Aim:This study tested a setup for in vitro experimental analysis of axial forces and torque during the preparation of artificial canals using nickel-titanium reciprocating endodontic files.Methods: The cutting efficiency of Reciproc (RC) and WaveOne (WO) reciprocating size 25/.08 instruments (n = 10) was evaluated, taking into account their dimensional and geometrical features. Measurements of the diameter at each millimeter from the tip, pitch length, helical angle, and cross-sectional design and area were assessed. Cutting efficiency tests were carried out on a specific bench device by measuring the torque and axial force required during artificial canal shaping. Statistical analysis was performed using one-way ANOVA (α = 0.05). Results:The WO samples showed larger A3 mean values than did the RC instruments (p < 0.0001), despite having equal diameters at 3mm from the tip (D3) (p = 0.521). The mean values of pitch length were higher for RC than for WO instruments (p< 0.0001), with consequently smaller helical angles (p < 0.0001). For the cutting efficiency tests, the required torque was lower for the RC group when compared to the WO group, but it was significant only in the first stage of insertion in the artificial canals (p = 0.008). Regarding the apical force, the RC instruments reached higher values when compared to the WO instruments (p = 0.04) in the second stage of cutting action. Conclusion: Reciproc instruments demonstrated statistically higher cutting efficiency when compared to WaveOne instruments.


Objetivo: Este estudo testa uma configuração para análise experimental in vitro de forças axiais e torque durante o preparo de canais artificiais usando instrumentos endodônticos reciprocantes de níquel-titânio. Métodos: Foi avaliada a eficiência de corte dos instrumentos reciprocantes tamanho 25 / 0,08 (n = 10) Reciproc (RC) e WaveOne (WO), levando em consideração suas características dimensionais e geométricas. Medidas do diâmetro a cada milímetro a partir da ponta, comprimento de pitch, ângulo helicoidal e desenho da área transversal e área foram avaliados. Testes de eficiência de corte foram realizados em um dispositivo de bancada específico, medindo-se o torque e a força axial exigidos durante a modelagem de canais artificiais. A análise estatística foi feita com ANOVA one-way (α = 0,05). Resultados: As amostras de WO mostraram valores médios A3 maiores do que os instrumentos RC (p <0,0001), apesar de terem diâmetros iguais a 3 mm da ponta (D3) (p = 0,521). Os valores médios do comprimento do pitch foram maiores para o RC do que para os instrumentos do WO (p < 0,0001), com consequentemente menores ângulos helicoidais (p < 0,0001). Para os testes de eficiência de corte, o torque necessário foi menor para o grupo RC em comparação com o grupo WO, mas significativo apenas no primeiro estágio de inserção nos canais artificiais (p = 0,008). Em relação à força apical, os instrumentos RC alcançaram valores maiores em relação aos instrumentos WO (p = 0,04) no segundo estágio de corte. Conclusão: Os instrumentos Reciproc demonstraram uma eficiência de corte estatisticamente superior em comparação com os instrumentos WaveOne.


Subject(s)
Materials Testing , Torque , Dental Instruments , Dental Pulp Cavity , Endodontics
2.
Acta odontol. latinoam ; 29(3): 262-267, 2016. ilus, tab
Article in English | LILACS | ID: biblio-868700

ABSTRACT

Endodontic retreatment requires complete removal of the filling material and access to the apical foramen. The purpose of this study was to evaluate the effectiveness of the WaveOne reciprocating system and compare it to the ProTaper D rotary system, with or without the use of a solvent, in removing filling material from root canals. The time required for each filling removal technique employed was also determined and compared. Forty extracted human mandibular premolars with a single, straight, flattened canal were prepared and filled. They were divided into four groups (n = 10): Group 1: ProTaper D NiTi rotary instruments; Group 2: ProTaper D NiTi rotary instruments, with a solvent; Group 3: WaveOne primary instrument; and Group 4: WaveOne primary instrument, with a solvent. The teeth were then split along their long axis and photographed using an operating microscope with 5X magnification. The amount of remaining filling material was assessed with Image Tool software. The results were compared using the KruskalWallis test (p <0.05). There was no significant difference between groups regarding the amount of residual filling material (p > 0.05). Operative time was significantly longer in Group 3 than in groups 1, 2 and 4 (p < 0.05). The WaveOne system and the ProTaper D system were equally effective, with or without a solvent. The time required to remove the filling material from the canals was significantly longer in Group 3 than in the other groups.


No retratamento endodôntico, a completa remoção do material obturador e o acesso ao forame apical são necessários para permitir a limpeza do sistema de canais. O propósito deste estudo foi avaliar a eficácia do sistema reciprocante WaveOne e comparála ao sistema rotatório ProTaper Universal, com ou sem o uso de solvente, na remoção do material obturador.O tempo necessário a cada técnica empregada foi determinado e comparado. Quarenta prémolares inferiores humanos extraídos com canal único, reto e achatado foram preparados e obturados. Foram então divididos em quatro grupos (n = 10) de acordo com o sistema utilizado, como segue. Grupo 1: ProTaper D Niti; Grupo 2: Sistema ProTaper D com solvente; Grupo 3: Sistema WaveOne instrumento Primary; e Grupo 4: Sistema WaveOne instrumento Primary com solvente, sendo o tempo registrado. Os dentes foram clivados longitudinalmente e fotografados utilizando microscópio operatório com aumento de 5 vezes.A quantidade de material remanescente foi avaliada com o uso do software Image Tool 3.0. Os resultados foram comparados utilizando o teste de KruskalWallis( p < 0.05). Em relação aos resultados, não houve diferença significativa entre os grupos quanto à quantidade de material obturador residual (p > 0.05). O tempo operatório no Grupo 3 foi significativa mente maior do que nos grupos 1, 2 e 4 (p < 0.05).O sistema WaveOne foi tão efetivo quanto o ProTaper D, com ou sem solvente.tempo necessário à desobturação dos canais no Grupo 3 (WaveOne sem solvente) foi significativamente maior do que nos demais grupos.


Subject(s)
Humans , Dental High-Speed Equipment , Gutta-Percha , Retreatment/methods , Solvents/chemistry , Root Canal Therapy/adverse effects , Bicuspid , Brazil , Root Canal Obturation/instrumentation , Rotation , Data Interpretation, Statistical , Time Factors
3.
ROBRAC ; 22(63)out.-dez. 2013. tab, ilus
Article in Portuguese | LILACS | ID: lil-737225

ABSTRACT

Objetivo: Comparou o tempo de preparo, ocorrência de fratura e manutenção do trajeto do canal em canais artificiais do instrumento Reciproc R25 em movimento reciprocante e rotação contínua anti-horária. Material e Métodos: Foram utilizados dois grupos contendo 10 canais artificiais em blocos de acrílico cada, sendo um o grupo controle, instrumentado com movimento reciprocante, e o grupo teste utilizando rotação contínua anti-horária a 300rpm para a instrumentação. Resultados: os resultados mostraram que houve diferença estatística significante em relação ao tempo de preparo entre os grupos, uma vez que a rotação contínua anti-horária proporcionou um menor tempo de preparo; ambos mantiveram o trajeto original do canal sem qualquer desvios no terço apical e ocorreu uma fratura no grupo da rotação contínua. Conclusão: o sistema Reciproc manteve a trajetória original do canal, não influenciou na incidência de fratura dos instrumentos e demandou menor tempo de preparo utilizando rotação contínua. Portanto, o sistema Reciproc pode ser utilizado com rotação contínua anti-horária desde que velocidade, torque e pressão apical sejam respeitados e se empregue os instrumento uma única vez.


Objective: This study aimed to compare the preparation time, occurrence of fracture and maintenance of the canal path in artificial canals using Reciproc R25 instrument moving reciprocating and continuous counterclockwise rotation. Methods: Two groups of 10 Simulated rootcanals, each one in an artificial acrylic block, was instrumented with reciprocating motion (control group) and using counterclockwise continuous rotation to 300rpm (test group). Results: The results showed statistically significant difference in relation to the preparation time between the groups, since the counterclockwise continuous rotation allowed shorter preparation time, both kinematics kept the original route of the canal without any deviations in the apical third. A fracture occurred in the group of continuous rotation. Conclusion: The Reciproc system kept the original trajectory of the canals and did not influence the incidence of instruments fracture. A less preparation time was required when the continuous rotation was used. Therefore, the Reciproc system can be used with counterclockwise continuous rotation since that speed, torque and apical pressure are respected. The instrument also should be employed just one time.