Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Chinese Journal of Radiation Oncology ; (6): 346-349, 2010.
Article in Chinese | WPRIM | ID: wpr-388970

ABSTRACT

Objective To find a method to improve the range accuracy of moving target such as peripheral lung tumors, since a single CT snapshot may not be accurate during the treatment process.Methods A simple harmonic motion phantom, embedded with a cube and a circular ball, was used to simulate the tumor motion. Individualized moving targets were scanned 24 times with different amplitudes and frequencies. Then the images were fused from every 1, 2 or 3 sets of CT scans. The GTV volume variation of circular target and the length variation of the cube target along the z axis were contoured and analyzed. Results As motion amplitude increased, the maximum of both circular target volume and cube target length was increased, while the minimum of the factors was decreased. Motion frequency affected the target volume less than amplitude. For a cube target with the length of 3.3 cm at stationary phase, when motion frequencies was 20 and motion amplitude was 2 cm, the maximal length was 2. 4 times of the minimal length (5. 1 cm vs. 2. 1 cm). When it came to the cube target groups fused from every 1,2 and 3 sets of CT scans, the average length and standard deviation were (3.77 ± 1.20) cm, (4.18 ±0. 91)cm and (4.52 ±0. 59) cm, respectively. With the increase of fused scan number, targets became bigger, the standard deviation decreased, and the change of center positions was decreased. Conclusions The motion amplitude, frequency and the number of CT scans are the main factors affecting target definition, though, the optimized scanning phase is not certained. When 4DCT and respiration gating technique are not available,the efficient and practical method to solve this problem is to scan the target three or more times and fuse them in planning system, which will generate a larger, more reproducible GTV volume for moving targets.

2.
Journal of the Korean Academy of Rehabilitation Medicine ; : 899-904, 1999.
Article in Korean | WPRIM | ID: wpr-723664

ABSTRACT

OBJECTIVE: The purpose of this study is to evaluate the balance training effects of balance system in hemiplegic stroke patients. METHOD: The study consisted of 14 male and 6 female hemiplegic patients, aged 48 to 70 years, time postattack ranged from 6 to 17 months. Balance training was done by conventional method (control group) and using balance system (Chattanooga Group, Inc., training group) and the effect were evaluated by balance system. RESULTS: Body sway index and moving target accuracy rate were not significantly different between training group and control group before training, but were significantly different after training. Training group showed significantly decreased sway index and increased moving target accuracy rate at four weeks after training compared to the status before training. CONCLUSION: The hemiplegic patients trained by balance system showed significantly improved static and dynamic postural balance control. Therefore, the balance system is considered to be a valuable training modalitiy for the hemiplegic patients.


Subject(s)
Female , Humans , Male , Postural Balance , Stroke
SELECTION OF CITATIONS
SEARCH DETAIL