Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 196
Filter
1.
Chinese Journal of Radiological Health ; (6): 75-80, 2023.
Article in Chinese | WPRIM | ID: wpr-965377

ABSTRACT

@#Primary small bowel tumors have low incidence and contain predominantly solid components, and the lesions are similar and difficult to be detected and distinguished with multislice spiral CT (MSCT) plain scans. In this article we describe contrast-enhanced MSCT technique and imaging characteristics for solid small bowel tumors or small bowel tumors containing predominantly solid components, including the type and use of contrast agents. In contrast-enhanced MSCT, small bowel imaging with CT has the advantages of determining the true extent of intestinal wall lesions, the possible extent of wall penetration, the degree of mesenteric involvement, and distant metastases, as well as easiness to detect and identify the blood supply vessels of small bowel tumors and assessment of the corresponding complications. Contrast-enhanced MSCT has become the best noninvasive imaging technique for the diagnosis, evaluation, and staging of solid small bowel tumors or small bowel tumors containing predominantly solid components. CT texture analysis (CTTA) is a new research hotspot and can be useful for the correct diagnosis of primary small bowel tumors containing predominantly solid components.

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 379-385, 2023.
Article in Chinese | WPRIM | ID: wpr-993101

ABSTRACT

Objective:To compare the differences in radiation dose and image quality between cone-beam CT (CBCT) and multi-slice spiral CT (MSCT) applied to atlantoaxial spine imaging.Methods:Head and neck phantom was scanned at 30 exposure parameter combinations using Pramerica CBCT scanner and 15 parameter combinations using Toshiba 320-row MSCT. The effective dose ( E) of CBCT was calculated based on the Monte Carlo dose estimation software PCXMC, the E value of MSCT was obtained by multiplying the dose length product (DLP) by the related factor. t-test for two independent samples or Wilcoxon rank sum test were used for comparison of radiation dose and subjective and objective image quality between two modalities. The subjective evaluation was a 5-point subjective scale using double-blind method for edge sharpness, contrast, soft tissue level, and artifacts of the images. The signal and noise in the region of interest (ROI) were measured and the contrast signal-to-noise ratio (CNR) was calculated. Results:For radiation dose, the volumetric dose index and E values of 2.9 mGy and 27.61 μSv for CBCT were lower than those of 8.8 mGy and 433.16 μSv for MSCT, and the differences were statistically significant( z=-3.05, -5.25, P<0.05). For objective evaluation of image quality, the noise and CNR were 27.74 HU and 3.69 in CBCT group, 7.84 HU and 27.1 in MSCT group. The difference between them were statistically significant( z=-5.39, -5.42, P<0.05). The overall image quality, contrast and artifact scores of the CBCT group were 3.5, 3.0 and 5 were higher than those of the MSCT group at 2.0, 2.0, and 4.0, respectively ( z=-2.32, -2.46, -3.31, P<0.05). Conclusions:Both atlantoaxial CBCT and MSCT scans provide image quality that meets diagnostic requirements. Compared to MSCT, CBCT atlantoaxial scans can effectively reduce radiation dose according to the principle of optimization of radiation protection.

3.
Journal of Chinese Physician ; (12): 296-299, 2023.
Article in Chinese | WPRIM | ID: wpr-992295

ABSTRACT

Rectal cancer is a common malignancy of the gastrointestinal tract. Extramural vascular invasion (EMVI) is a key indicator of risk stratification for rectal cancer and an important reference factor in determining individualised treatment options, so it is important to accurately assess whether extramural vessels are infiltrated by the tumour before surgery. The main imaging methods for rectal cancer include magnetic resonance imaging (MRI), computed tomography (CT) and transrectal ultrasound (TRUS). This article focuses on the performance and diagnostic efficacy of these imaging methods in the diagnosis of EMVI in rectal cancer, and provides clinical reference.

4.
Braz. j. otorhinolaryngol. (Impr.) ; 88(supl.5): 52-56, Nov.-Dec. 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1420887

ABSTRACT

Abstract Objective: With this radio-anatomical study, we aimed to describe the distribution of the depth of the olfactory fossa based on the Keros classification in the pediatric population in our region and to reduce complication rates by providing normative data. Methods: This was a retrospective study conducted with computed tomography imaging of the paranasal sinuses of 390 pediatric patients referred over a six-year period in Sakarya and Kocaeli University Faculty of Medicine. Patients were divided into 3 groups as 1-6, 6-12, and 12-18 years old. The depth of the olfactory fossa was measured and classified according to the Keros classification. The incidence of Keros asymmetries was also investigated. Results: The distribution of the depth of a total of 780 olfactory fossa according to the Keros classification was 24.7% Keros I, 65.9% Keros II, and 9.4% Keros III. When the groups were evaluated with each other and within each group, it was seen that the prevalence of Keros I type was significantly higher in the first group (p < 0.05), and the prevalence of Keros type II was significantly higher in the second and third groups (p < 0.05). Apart from this, the number of Keros type III increased in the third group compared to the first two groups and showed a statistically significant difference (p < 0.05). Among all patients, asymmetry of the olfactory fossa was detected in 29 patients (7.4%). Although the number of olfactory fossa asymmetry was low in group I, it was not significantly different between the groups (p > 0.05). Conclusion: In our study, high Keros I rate and low Keros III rate in children aged -6 were remarkable. Especially for children under the age of six, questions arise about the validity of the Keros classification. More detailed studies in larger populations, in different ethnicities, and with various age groups are needed. Level of evidence: Level 3.

5.
Rev. argent. radiol ; 86(2): 115-123, jun. 2022. graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1387609

ABSTRACT

Resumen Para la reconstrucción y el tratamiento de anomalías que comprometen la aorta torácica pueden emplearse diversas técnicas quirúrgicas abiertas, las cuales estarán determinadas por la patología que presente el paciente. La angiotomografía computada multicorte (ATCMC) es el método de elección para su control y seguimiento. El médico radiólogo debe estar familiarizado con las técnicas quirúrgicas empleadas (Wheat, Bentall de Bono, Cabrol, entre otras), con las reparaciones estructurales que se realizan y con los materiales protésicos utilizados con el fin de evitar una interpretación errónea de las imágenes. El fieltro espontáneamente hiperdenso, los conductos protésicos y sus anastomosis, tanto con la aorta como con los grandes vasos, puede generar errores en el informe final y en el diagnóstico.


Abstract Multiple surgical techniques can be used for the reconstruction and treatment of abnormalities that compromise the thoracic aorta, which will be determined by the patient’s pathology. Multislice computed tomography angiography is the method of choice for their control and monitoring. The radiologist should be familiar with the surgical techniques used (Wheat, Bentall de Bono, and Cabrol, among others), as well as with the structural repairs that are performed and the prosthetic materials used in order to avoid an erroneous interpretation of the images. Spontaneously hyperdense felt, the prosthetic ducts and their anastomosis, both with the aorta and the large vessels, can generate pitfalls in the final report and error in the diagnosis.

6.
Journal of Forensic Medicine ; (6): 589-594, 2022.
Article in English | WPRIM | ID: wpr-984151

ABSTRACT

OBJECTIVES@#To explore the relationship between the height of alveolar bone resorption and sex and age in the adolescent dentition.@*METHODS@#Multi-slice computed tomography (MSCT) was used to measure the height of alveolar bone resorption at labial, lingual, mesial and distal sites of teeth in 149 adolescents aged from 10 to 20 years. SPSS 25.0 software was used to analyze the relationship between the height of alveolar bone resorption and sex and age.@*RESULTS@#There was no significant difference in the height of alveolar bone resorption between sex (P>0.05). The height of alveolar bone resorption was positively correlated with age in all types of teeth. The model constructed by combining the alveolar bone resorption height data of four sites (y=2.569x1+3.106x2+4.108x3+1.451x4-0.082, R2max=0.756)had a better ability to infer age than that of combining two sites (y=5.942x1+4.489x2+0.612, R2max=0.706) and a single site (R2max=0.638).@*CONCLUSIONS@#The height of alveolar bone resorption is positively correlated with the age of adolescents. The combination of four sites has a stronger ability to infer the relationship between the height of alveolar bone resorption and age in adolescents and has higher accuracy in practical application.


Subject(s)
Humans , Adolescent , Child , Young Adult , Adult , Alveolar Process/diagnostic imaging , Cone-Beam Computed Tomography , Bone Resorption/diagnostic imaging , Tomography, X-Ray Computed
7.
International Journal of Biomedical Engineering ; (6): 374-378, 2021.
Article in Chinese | WPRIM | ID: wpr-929918

ABSTRACT

Objective:To investigate the imaging characteristics of chest CT angiography in patients with active pulmonary tuberculosis complicated with pulmonary embolism, so as to improve the detection rate of active pulmonary tuberculosis complicated with pulmonary embolism.Methods:The clinical data of 103 patients with active pulmonary tuberculosis treated in Tianjin Haihe Hospital from January 2013 to January 2020 were retrospectively analyzed, including general conditions, symptoms and complications. According to the occurrence of pulmonary embolism, the patients were divided into active pulmonary tuberculosis complicated with pulmonary embolism group (study group, n=43) and active pulmonary tuberculosis without pulmonary embolism group (control group, n=60). The time between the onset of pulmonary embolism and the onset of tuberculosis of the patients in the study group was collected. The chest CT imaging characteristics of the patients of two groups were analyzed. The imaging characteristics, embolism distribution and secondary changes of the patients in the study group were summarized. Results:Time from onset of tuberculosis to pulmonary embolism of the patients in the study group was about 60 days (14 days to 75 days). The incidence of chest tightness and dyspnea of the patients in the study group was significantly higher than that in the control group (all P<0.05). The number of lung lobes involved in lung lesions of the patients in the study group was significantly higher than that in the control group ( P<0.05). The incidence of lesions in the middle lobe of the right lung, the tongue lobe of the left lung and the lower lobes of both lungs of the patients in the study group was higher than that in the control group (all P<0.05). The incidence of peripheral pulmonary embolism was significantly higher than that of central pulmonary embolism ( P<0.05). However, the incidence of atelectasis, pulmonary artery widening, and right heart enlargement in the patients with central pulmonary embolism was significantly higher than that in the patients with central pulmonary embolism (all P<0.05). Conclusions:Multi-slice spiral CT chest angiography can show some important imaging manifestations of patients with active pulmonary tuberculosis and pulmonary embolism, which is helpful for the early detection of the disease and the improvement of its prognosis. Multi slice spiral CT chest angiography can show some important imaging manifestations of patients with active pulmonary tuberculosis complicated with pulmonary embolism, and timely detection is helpful to improve the prognosis of patients with active pulmonary tuberculosis complicated with pulmonary embolism.

8.
Chinese Journal of Hepatobiliary Surgery ; (12): 658-662, 2021.
Article in Chinese | WPRIM | ID: wpr-910613

ABSTRACT

Objective:To analyze the imaging features of spontaneous rupture of primary liver cancer (PLC) and to study the high-risk factors associated with tumor rupture.Methods:From September 2016 to August 2020, 81 patients who developed spontaneous rupture of PLC at the General Hospital of Ningxia Medical University were included into this study. A control group of 81 patients with tumors located on the periphery of the liver but without rupture treated in the same period were selected by matching the two groups with age, sex and BCLC staging. The clinical data and CT imaging characteristics including tumor location, extent, size, and morphology of the two groups of patients were compared retrospectively between groups.Multivariate logistics regression was used to analyze.Results:A total of 81 patients were included in the case group, including 72 males and 9 females, aged (53.69±10.34) years. The control group included 81 patients, 64 males and 17 females, aged (54.78±9.04) years. The main risk factors for spontaneous rupture of PLC included in this study were cirrhosis, tumor close to diaphragm, biolobar distribution, portal vein obstruction, tumor diameter >10 cm, invasion of liver capsule (arc-to-chord ratio>1) and tumor protrusion ≥25% ( P<0.05). Logistic regression analysis showed that cirrhosis ( OR=2.796, 95% CI: 1.721-10.834), portal vein obstruction ( OR=3.586, 95% CI: 1.272-10.107) and tumor protrusion (≥25%) ( OR=2.831, 95% CI: 1.668-22.210) were independent predictive factors of spontaneous rupture of PLC. Conclusion:Tumor protrusion≥25%, cirrhosis and portal vein obstruction were closely related to spontaneous rupture of PLC. They were independent risk factors in predicting rupture of primary liver cancer.

9.
Journal of Chinese Physician ; (12): 1444-1447, 2021.
Article in Chinese | WPRIM | ID: wpr-909721

ABSTRACT

Objective:To evaluate direct bilirubin /total bilirubin(D/T), B-mode ultrasound(BUS), multislice spiral computed tomography (MSCT), magnetic resonance cholangiopancreatography (MRCP) and endoscopic ultrasound (EUS) in the diagnosis of choledocholithiasis abdominal pain (CAP).Methods:We retrospectively analyzed the materials of patients who were diagnosed with choledocholithiasis abdominal pain by above imagines in the emergency department of Beijing Friendship Hospital during March 2016 to December 2018. The stones were taken out by endoscopic retrograde cholangiopancreatography or surgical operation as the golden standard.Results:Among 256 patients, 195 cases, 138 cases, 107 cases and 26 cases were diagnosed by EUS, MRCP, CT and BUS, respectively. The sensitivity were 0.86, 0.62, 0.45, 0.13, respectively. The specificity were 0.86, 0.81, 0.75, 0.87. The positive predictive value were 0.97, 0.96, 0.91, 0.83.The negative predictive value were 0.55, 0.19, 0.21, 0.16. The accuracy rate were 0.88, 0.64, 0.48, 0.30, respectively. The sensitivity of D/T and D/T combined with EUS in the diagnosis of CAP were 0.57 and 0.67, and the accuracy were 0.16 and 0.56, respectively.Conclusions:EUS has a high diagnostic value for CAP. MRCP is superior to CT in the value of diagnosis of CAP. BUS in imaging diagnosis of CAP value is relatively low, but D/T combined with BUS can improve the sensitivity and accuracy of diagnosis for CAP.

10.
Journal of International Oncology ; (12): 591-595, 2021.
Article in Chinese | WPRIM | ID: wpr-907586

ABSTRACT

Objective:To investigate the correlations between multi-slice spiral CT (MSCT) atypical pleomorphic signs and pathological findings of lung metastases.Methods:From January 2012 to July 2019, the MSCT chest imaging data of 168 metastatic tumor of lung from the General Hospital of Central Theater Command of the Chinese People′s Liberation Army and Shaanxi Provincial Tumor Hospital were collected. According to the pathological type, they were divided into metastatic adenocarcinoma group ( n=88) and metastatic squamous cell carcinoma group ( n=80). The atypical imaging signs of MSCT of the two groups were observed and recorded, and classified after labeling one by one. The difference of atypical MSCT imaging features between the two groups was compared, and the correlations between lesion size and atypical imaging features of MSCT in the metastatic adenocarcinoma group and metastatic squamous cell carcinoma group were analyzed. Results:The spicule sign in metastatic adenocarcinoma and metastatic squamous cell carcinoma were 61 (69.32%) and 28 (35.00%), with a statistically significant difference ( χ2=19.811, P<0.001). The pleural depression sign in the two groups were 48 (54.55%) and 16 (20.00%), and there was a statistically significant difference ( χ2=21.206, P<0.001). The vacuole/cavity sign in the two groups were 10 (11.36%) and 61 (76.25%), and there was a statistically significant difference ( χ2=72.303, P<0.001). The air bronchial sign in the two groups were 43 (48.86%) and 13 (16.25%), with a statistically significant difference ( χ2=20.057, P<0.001). The halo sign/ground glass shadow in the two groups were 58 (65.91%) and 37 (46.25%), with a statistically significant difference ( χ2=6.591, P=0.010). The results of the Spearman rank correlation analysis indicated a positive correlation between the size of metastatic adenocarcinoma and spicule sign, pleural depression sign ( r=0.270, P=0.011; r=0.226, P=0.035). There was no correlation between the nodule size and atypical MSCT imaging features in metastatic squamous cell carcinoma (all P>0.05). Conclusion:The atypical MSCT of metastatic lung adenocarcinoma are mostly spicule sign, pleural depression sign, air bronchial sign and halo sign/ground glass shadow. The characteristic atypical imaging of metastatic squamous cell carcinoma is vacuole/cavity sign. The spicule sign and pleural depression sign are related to the size of metastatic lung adenocarcinoma nodules.

11.
Journal of International Oncology ; (12): 537-543, 2021.
Article in Chinese | WPRIM | ID: wpr-907575

ABSTRACT

Objective:To investigate the clinic diagnostic value of multi-slice CT (MSCT) imaging features in various subtypes of nodular lung adenocarcinoma.Methods:The imaging information and general clinical data of 160 patients with nodular lung adenocarcinoma who were admitted to Yantai Affiliated Hospital of Binzhou Medical University and received surgical treatment from January 2017 to May 2019 were retrospectively analyzed. Univariate analysis was used to screen statistically significant imaging features of each pathological subtype, and binary logistic regression analysis was performed. The diagnostic value was analyzed using the receiver operating characteristic (ROC) curve, the area under the curve (AUC) was calculated, and the diagnostic efficacy was compared.Results:The age of patients with atypical adenomatous hyperplasia and adenocarcinoma in situ (AAH+ AIS), minimally invasive ademocarcinoma (MIA), invasive adenocarcinoma cancer (IAC) and variant of invasive adenocarcinoma cancer (VIAC) were (57.07±7.92), (59.37±6.96), (60.68±8.83), (63.33±6.89) years old, with no statistically significant difference ( F=1.221, P=0.304). The age of patients with VIAC, IAC, MIA and AAH+ AIS decreased in turn. The imaging features of AAH+ AIS, MIA, IAC and VIAC that exhibited statistically significant differences were as following in turn: the maximum diameter of lesion [6.85 (3.73) mm vs. 8.00 (5.00) mm vs. 16.00 (11.90) mm vs. 17.20 (9.08) mm, H=55.107, P<0.001], CT value [-563.50 (176.63) HU vs. -536.00 (293.50) HU vs. -235.50 (346.50) HU vs. -23.00 (30.50) HU, H=47.499, P<0.001], solid ratio [0 (0) vs. 0 (0) vs. 49.00% (100.00%) vs. 100.00% (0), H=44.242, P<0.001], vacuolar sign [14 (87.50%) vs. 35 (100.00%) vs. 84 (81.55%) vs. 3 (50.00%), χ2=13.925, P=0.002], inflatable bronchus sign [1 (6.25%) vs. 2 (5.71%) vs. 36 (34.95%) vs. 2 (33.33%), χ2=16.578, P=0.001], intratumoral vascular sign [13 (81.25%) vs. 28 (80.00%) vs. 64 (62.14%) vs. 1 (16.67%), χ2=11.168, P=0.009], vessel convergence sign [1 (6.25%) vs. 3 (8.57%) vs. 66 (64.08%) vs. 6 (100.00%), χ2=54.232, P<0.001], short burr sign [3 (18.75%) vs. 11 (31.43%) vs. 77 (74.76%) vs. 6 (100.00%), χ2=36.218, P<0.001], lobulation sign [4 (25.00%) vs. 18 (51.43%) vs. 93 (90.29%) vs. 6 (100.00%), χ2=43.302, P<0.001], pleural traction sign [0 (0) vs. 6 (17.14%) vs. 70 (67.96%) vs. 5 (83.33%), χ2=50.794, P<0.001]. The maximum diameter of lesion ( OR=0.858, 95% CI: 0.754-0.977, P=0.021) and pleural traction sign ( OR=0.288, 95% CI: 0.084-0.993, P=0.049) were independent influencing factors of MIA. The maximum diameter of lesion ( OR=1.131, 95% CI: 1.030-1.241, P=0.010) and pleural traction sign ( OR=3.441, 95% CI: 1.279-9.254, P=0.014) were independent influencing factors of IAC. The optimum threshold of the maximum diameter of lesion in diagnosis of MIA was 11.05 mm, AUC was 0.798 (95% CI: 0.724-0.872) sensitivity was 68.00%, and specificity was 85.70%. The AUC of pleural traction sign in diagnosis of MIA was 0.714 (95% CI: 0.623-0.806). The diagnostic efficacy exhibited no statistically significant difference between the maximum diameter of lesion and pleural traction sign in diagnosis of MIA ( Z=1.838, P=0.066). The optimum threshold of the maximum diameter of lesion in diagnosis of IAC was 11.05 mm, AUC was 0.827 (95% CI: 0.759-0.895), sensitivity was 75.70%, and specificity was 78.90%. The AUC of pleural traction sign in diagnosis of IAC was 0.743 (95% CI: 0.663-0.823). The diagnostic efficacy exhibited statistically significant difference between the maximum diameter of lesion and pleural traction sign in diagnosis of IAC ( Z=2.114, P=0.035), and the maximum diameter of lesion > 11.05 mm was better for the diagnosis of IAC. Conclusion:The maximum diameter of lesion and pleural traction sign are independent influence factors in diagnosis of MIA and IAC, and the maximum diameter of lesion > 11.05 mm is better for the diagnosis of IAC.

12.
Radiol. bras ; 53(6): 413-418, Nov.-Dec. 2020. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1136110

ABSTRACT

Abstract As they are asymptomatic or have a nonspecific, anatomical variations of the ribs are usually detected as incidental findings on imaging studies. They may be isolated changes or can be related to anomalies or clinical syndromes. Such variations are easily overlooked on conventional radiography and computed tomography if they are not actively investigated, mainly because most indications for a chest X-ray studies aim to evaluate the lung parenchyma and mediastinal structures. The objective of this pictorial essay was to use multislice computed tomography images to illustrate the imaging aspects of the main anatomical variations and congenital anomalies of the ribs.


Resumo As variantes anatômicas dos arcos costais são, geralmente, achados incidentais nos exames de imagem, em razão do seu comportamento assintomático ou quadro inespecífico, podendo constituir alterações isoladas ou relacionadas a anomalias e síndromes clínicas. Essas alterações são facilmente negligenciadas na radiografia convencional e na tomografia computadorizada se não forem investigadas ativamente, principalmente quando a maioria das indicações do estudo radiológico do tórax tem como objetivo a avaliação do parênquima pulmonar e das estruturas mediastinais. O objetivo deste artigo é demonstrar, por meio da tomografia computadorizada multidetectores, os aspectos de imagem das principais variantes anatômicas e anomalias congênitas dos arcos costais.

13.
Radiol. bras ; 53(4): 255-261, July-Aug. 2020. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1136082

ABSTRACT

Abstract China was the epicenter for the novel coronavirus disease (COVID-19), which quickly spread to other Asian countries and later to Western countries; subsequently, COVID-19 was categorized as a pandemic by the World Health Organization. Diagnosis primarily depends on viral detection in respiratory samples; however, available kits are limited, lack high sensitivity, and have a long turnaround time for providing results. In this scenario, computed tomography has emerged as an efficient and available high-sensitivity method, allowing radiologists to readily recognize findings related to COVID-19. The objective of this article is to demonstrate the main tomographic findings in symptomatic respiratory patients with COVID-19 to assist medical professionals during this critical moment.


Resumo A doença pelo novo coronavírus (COVID-19) teve epicentro na China e rapidamente se espalhou pelos demais países asiáticos e, posteriormente, para os países ocidentais, sendo definida como pandemia pela Organização Mundial da Saúde. O diagnóstico da COVID-19 é primariamente dependente da pesquisa do vírus nas vias aéreas superiores, mas os kits para sua confirmação ainda são limitados, não apresentam sensibilidade elevada e os resultados são demorados. Nesse cenário, a tomografia computadorizada surge como método eficiente e disponível e com alta sensibilidade, cabendo a nós radiologistas reconhecer prontamente os achados relacionados a essa doença. O objetivo deste artigo é demonstrar os principais achados tomográficos de tórax em pacientes sintomáticos respiratórios infectados pela COVID-19, de modo a auxiliar os colegas nesse momento crítico.

14.
Article | IMSEAR | ID: sea-212166

ABSTRACT

Background: Multi-slice computed tomography (MSCT) is the main stay of pre-operative assessment of many complex congenital heart diseases (CHD) in current clinical practice, one of them is double outlet of right ventricle (DORV). DORV is one of the conotruncal anomalies that encompasses a wide spectrum of anatomic malformations in which both the aorta and pulmonary arterial trunk arise entirely or predominantly from the morphologically right ventricle (RV). Purpose of this article is to understand spectrum of DORV and associated types of ventricular septal defect (VSD) on MSCT imaging with special emphasis of usefulness of 3-D volume rendered (VR) images in pre surgical evaluation.Methods: A total of 500 paediatric patients (<18 years old), who had undergone MSCT were studied during the period 2014 to 2019 at the tertiary cardiac care centre.Results: 500 patients having primary/suspicious diagnosis of DORV on echocardiography during the said period were enrolled in the study. All the patients who underwent MSCT scan, were studied in detail for: DORV spectrum, associated types of VSD and its relationship to the semilunar valves. Out of 500 total subjects, subaortic VSD was the most common type of VSD observed (53%), followed by subpulmonic VSD (22%), non-committed VSD (18%) and doubly committed VSD (7%). Associations of pulmonary stenosis, subaortic stenosis and aortic co-arctation with various types of VSDs were addressed. Associated other anomalies were also analysed.Conclusions: Advances in MSCT technology has revolutionized pre-surgical diagnosis, management approach and post-operative follow-up of DORV patients. Excellent image qualities along with 3D volume rendered images help surgeon understand complex morphology of DORV variants and associated types of VSD. Significant reduction in intra and post-operative mortality in DORV patients in current era is result of MSCT technology.

15.
Article | IMSEAR | ID: sea-209287

ABSTRACT

Background: Acute appendicitis is one of the most common abdominal surgical emergencies requiring accurate diagnosis. Itis characterized by obstruction of its lumen, leading to inflammation and finally perforation. To define its prognosis, choose anappropriate surgical procedure and to decide non-surgical treatment, the pre-operative diagnosis of perforated or non-perforatedappendicitis is very important.Aim of the Study: This study aims to analyze the diagnostic accuracy of computed tomography (CT) scan abdomen indifferentiating perforated from non-perforated appendicitis using histopathology as the final diagnosis.Materials and Methods: Aprospective, cross-sectional analytical study, wherein 85 patients diagnosed with acute appendicitisreferred to the radiological department for CT scan abdomen were included in the study. Patients aged between 15 and 70 yearswere included in the study. CT scan abdomen with and without contrast was performed on a Toshiba 64 Multislice CT scanner(Toshiba Medical Systems Corp., Tokyo, Japan) which was used for all the patients. All the CT scans were interpreted by the sameconsultant radiologists with a minimum of 5 years of experience. The radiological features for the diagnosis of non-perforatedacute appendicitis by CT were based on swollen appendix, thickened enhancing wall, and smudging of surrounding fat planes,whereas the radiological features for perforated appendicitis used were, with abscess formation, phlegmon, extraluminal air,extraluminal appendicolith, and focal defect in the appendicular wall. Histopathology of the specimen collected following surgerywas undertaken by the hospital consultant pathologist of more than 5-year experience.Observations and Results: Among the 85 patients included in this study for the analysis of CT scan abdomen features, therewere 57 (67.05%) males and 28 (32.94%) females with a male-to-female ratio of 2.03:1. The mean age of the patients was38.90 ± 6.70 years. The incidence of non-perforated appendicitis was 66/85 (77.64%) including males 44/85 (51.76%) andfemales 22/85 (25.88%). The incidence of perforated appendicitis was 19/85 (22.35%) and males were 12/85 (14.11%) and 7/85(8.23%) were female. Patients aged 15–45 years of both genders constituted to 63/85 (74.11%) of the total patients. Amongthese patients, presenting with non-perforated appendicitis was 51/85 (60%) and perforated appendicitis was 12/85 (14.11%).Conclusions: Multislice CT scan abdomen was considered as the modality of choice for acute appendicitis not only to confirmthe diagnosis but also it plays an important role in assessment of appendicular complication, particularly in the detection ofperforated appendix. Using one or more of the five radiological signs of CT scan abdomen to identify appendicular perforationraised the sensitivity significantly reaching 94.12%.

16.
Journal of Forensic Medicine ; (6): 820-827, 2020.
Article in Chinese | WPRIM | ID: wpr-985180

ABSTRACT

Virtual autopsy is a new technique for investigating the morphological changes of cadaveric tissues and organs by medical imaging technology. It has been widely used in the identification of causes of death. Multislice spiral computed tomography (MSCT) has become a routine inspection method in some identification institutions, although it cannot completely replace traditional autopsy, it plays a key auxiliary or substitute role in the identification of certain abnormal causes of death. Plain MSCT scan cannot visualize cadaveric vessels, but can perform cadaveric angiography to determine vascular injury or disease. This technology has entered a rapid development period in recent years, and has made a considerable progress in contrast agent, perfusion methods and imaging methods. This article summarizes several common cadaveric MSCT angiography methods, such as systemic angiography, angiography through cardiopulmonary resuscitation, targeted angiography, and angiography by cardiac puncture, and analyzes and compares the application prospects.


Subject(s)
Humans , Angiography , Autopsy , Coronary Angiography , Heart , Tomography, Spiral Computed
17.
Archives of Orofacial Sciences ; : 109-117, 2020.
Article in English | WPRIM | ID: wpr-875827

ABSTRACT

@#Any metallic object within the CT scanning field can produce metal artefacts, which will degrade the diagnostic image quality. Previous methods described for quantifying this kind of artefacts were complicated and difficult to reproduce. The purpose of this study was to introduce a new rapid method for quantifying the artefacts produced in craniofacial CT images. This is an in-vitro experimental study. Four different compositions of orthodontic brackets were bonded consecutively in the tooth surfaces of a cadaveric skull head. All scans were performed by a single operator using the same CT machine followed by a standard scanning protocol. Artefact intensity for all data sets was quantified by following a modified method with a freely available open-source software ImageJ. All datasets were duplicated where metal artefacts were quantified according to the previous conventional method. Statistical analysis included independent samples t-test for validation and intraclass correlation coefficient (ICC) with a 95% confidence interval for both intra- and inter-examiner reliability. The modified method of measuring artefact score exhibited excellent intra (0.997–0.941) and inter-rater (0.996–0.905) reliability. In addition, no significant difference (p = 0.072) of mean artefact score was noted between the groups measured by the modified method and the conventional method. This modified method for measuring the artefact intensity is valid and reliable.

18.
Chinese Journal of Hepatobiliary Surgery ; (12): 15-18, 2020.
Article in Chinese | WPRIM | ID: wpr-868751

ABSTRACT

Objective To study the clinical value of three-dimensional CT reconstruction model of portal venous system combined with finite element analysis to measure portal venous pressure in patients with portal hypertension.Methods A retrospective study was conducted on 27 patients who were diagnosed to have portal hypertension at the Second Affiliated Hospital of Kunming Medical University from May 2016 to May 2018.There were 17 males and 10 females,with ages ranging from 34 to 77 years (mean 56 years).All these patients underwent transjugular intrahepatic portal venous shunt (TIPS) during which the portal venous pressure was measured.The imaging data was imported into the three-dimensional software of medical imaging to reconstruct the three dimensional model of portal vein,and the finite element analysis software of ANSYS was used to calculate the portal venous pressure by calculation with given boundary conditions.Pearson correlation was used to analyze the correlation between the actual measurement of portal venous pressure and the predicted value.Results The actual measured value of portal vein pressure before TIPS in 27 patients with portal hypertension was (3 783 ±930) Pa,and the predicted value was (4 238 ± 1 218) Pa.There was no significant difference (P > 0.05).The predicted value of portal venous pressure was positively correlated with the actual measured value (r =0.402,95 % CI:0.026-0.678,P < 0.05).Conclusion Non-invasive measurement of portal venous pressure based on three-dimensional portal venous reconstruction combined with finite element analysis correlated with actual portal venous pressure in patients with portal hypertension.

19.
Medical Journal of Chinese People's Liberation Army ; (12): 542-546, 2020.
Article in Chinese | WPRIM | ID: wpr-849716

ABSTRACT

Objective To investigate the diagnostic value of multi-slice spiral CT (MSCT) perfusion imaging combined with serum cytokeratin 19 fragment antigen 21-1 (CYFRA21-1), carcinoembryonic antigen (CEA) and neuron specific enolase (NSE) for peripheral non-small cell lung cancer (NSCLC). Methods Based on diagnosis, 109 patients with suspected peripheral NSCLC admitted from Aug. 2017 to Aug. 2019 in the Xinxiang Central Hospital were divided into peripheral NSCLC group (n=65) and benign pulmonary nodule group (n=44). Another 56 healthy subjects undergone physical examination during the same period were selected as control group. The parameters of MSCT perfusion imaging and serum levels of CYFRA21-1, CEA and NSE in the 3 groups were compared. The receiver operating curve (ROC) was used to analyze the diagnostic value of MSCT perfusion imaging combined with serous levels of CYFRA21-1, CEA and NSE for peripheral NSCLC. Results The blood volume (BV) was larger in peripheral NSCLC group than those in benign pulmonary nodule group and control group [(10.76±1.26) ml/100 mg vs. (4.01±0.59) ml/100 mg and (2.32±0.42) ml/100 mg]; the same was for surface permeability (PS) [(42.56±5.60) ml/ (100 mg·min) vs. (16.13±1.88) ml/(100 mg·min) and (8.49±0.91) ml/(100 mg·min)]; and for the mean transit time (MTT) of contrast medium [(20.14±3.67) s vs. (12.85±1.49) s and (7.21±0.95) s]. All the BV, PS and contrast medium MTT were higher (larger) in benign pulmonary nodule group than those in control group (P<0.05). The serum level of CYFRA21-1 was higher in peripheral NSCLC group than that in benign pulmonary nodule group and control group [(8.94±1.67) ng/ml vs. (4.73±0.51) ng/ ml and (1.93±0.26) ng/ml]; the same was for the CEA level [(27.91±3.25) ng/ml vs. (7.88±0.92) ng/ml and (2.06±0.47) ng/ml]; and for the NSE level [(19.53±2.16) ng/ml vs. (15.02±1.74) ng/ml and (11.96±1.22) ng/ml]. All the serum levels of CYFRA21-1, CEA and NSE were higher in benign pulmonary nodule group than those in control group (P<0.05). The ROC results showed that the diagnosis of peripheral NSCLC alone and combined with MSCT perfusion imaging, serum levels of CYFRA21-1, CEA and NSE were 0.802, 0.794, 0.698, 0.712 and 0.841, respectively. The diagnostic value of combined detection of the four methods was higher than that of individual detection. Conclusion MSCT perfusion imaging combined with serum levels of CYFRA21-1, CEA and NSE have high diagnostic value for peripheral NSCLC.

SELECTION OF CITATIONS
SEARCH DETAIL