Chinese Journal of Contemporary Pediatrics ; (12): 86-91, 2024.
Article in Chinese | WPRIM | ID: wpr-1009898

ABSTRACT

Functional near infrared spectroscopy (fNIRS) is an emerging neuroimaging tool that reflects the activity and function of brain neurons by monitoring changes in brain oxygen metabolism based on the neurovascular coupling mechanism. It is non-invasive and convenient, especially suitable for monitoring neonatal brain function. This article provides a comprehensive review of research related to the developmental patterns of brain networks concerning language, music, and emotions in neonates using fNIRS. It also covers brain network imaging in neonatal care, resting-state brain network connectivity patterns, and characteristics of brain functional imaging in disease states of neonates using fNIRS.


Subject(s)
Infant, Newborn , Humans , Spectroscopy, Near-Infrared , Brain/diagnostic imaging , Emotions , Language , Technology
2.
Chinese Journal of School Health ; (12): 375-378, 2024.
Article in Chinese | WPRIM | ID: wpr-1013525

ABSTRACT

Objective@#The study aims to explore the neural mechanism of cognitive differences in college students with posttraumatic stress disorder under verbal fluency task based on functional near infrared spectroscopy (fNIRS), so as to provide neuroimaging support for the evaluation, diagnosis and treatment of posttraumatic stress disorder(PTSD).@*Methods@#Posttaumatic Stress Disorder Checklist Combat(PCL-C) was used to screen the subjects, including 21 students in PTSD group (PCL-C≥38) and 30 students in control group from September to Novenber in 2020. A 53 channel near infrared spectroscopy device was used to collect cerebral blood oxygen signals under the verbal fluency task, and correlation analysis, Mann Whitney U test and independent sample t test were performed on the results.@*Results@#The difference in the total average score of PCL-C Scale between PTSD group and the control group(46.38±6.96,25.57±6.09) was statistically significant ( t=11.33, P <0.05). Correlation analysis showed that Avg-HbO in left dorsolateral prefrontal lobe was negatively correlated with PCL-C Score ( r=-0.37, P <0.05). Mann Whitney U test showed that in the left dorsolateral prefrontal lobe (Ch6), the Avg-HbO change in PTSD group [0.19(-0.09, 0.86)mmol/(L〖KG*7〗·mm)] was significantly lower than the control group [0.79( 0.37 , 1.47)mmol/(L ·mm)] ( Z=2.16, P <0.05), which was statistically significant.@*Conclusions@#The degree of PTSD was negatively correlated with the index of oxygenated hemoglobin in the left dorsolateral prefrontal lobe, and the oxygenated hemoglobin content in the PTSD group was lower than that in the normal group. In the future, fNIRS may be used to collect blood oxygen signals from the left dorsolateral prefrontal lobe in cognitive tasks to provide imaging evidence for the identification of PTSD.

3.
Acta Pharmaceutica Sinica B ; (6): 378-391, 2024.
Article in English | WPRIM | ID: wpr-1011238

ABSTRACT

Gas therapy is emerging as a highly promising therapeutic strategy for cancer treatment. However, there are limitations, including the lack of targeted subcellular organelle accuracy and spatiotemporal release precision, associated with gas therapy. In this study, we developed a series of photoactivatable nitric oxide (NO) donors NRh-R-NO (R = Me, Et, Bn, iPr, and Ph) based on an N-nitrosated upconversion luminescent rhodamine scaffold. Under the irradiation of 808 nm light, only NRh-Ph-NO could effectively release NO and NRh-Ph with a significant turn-on frequency upconversion luminescence (FUCL) signal at 740 nm, ascribed to lower N-N bond dissociation energy. We also investigated the involved multistage near-infrared-controlled cascade release of gas therapy, including the NO released from NRh-Ph-NO along with one NRh-Ph molecule generation, the superoxide anion O2⋅- produced by the photodynamic therapy (PDT) effect of NRh-Ph, and highly toxic peroxynitrite anion (ONOO‒) generated from the co-existence of NO and O2⋅-. After mild nano-modification, the nanogenerator (NRh-Ph-NO NPs) empowered with superior biocompatibility could target mitochondria. Under an 808 nm laser irradiation, NRh-Ph-NO NPs could induce NO/ROS to generate RNS, causing a decrease in the mitochondrial membrane potential and initiating apoptosis by caspase-3 activation, which further induced tumor immunogenic cell death (ICD). In vivo therapeutic results of NRh-Ph-NO NPs showed augmented RNS-potentiated gas therapy, demonstrating excellent biocompatibility and effective tumor inhibition guided by real-time FUCL imaging. Collectively, this versatile strategy defines the targeted RNS-mediated cancer therapy.

4.
Article | IMSEAR | ID: sea-219300

ABSTRACT

The role of extracorporeal membrane oxygenation (ECMO) and its indications in stage I Norwood palliation are controversial. The decision to initiate ECMO and its timing remains difficult with no definitive cut?off points or evidence?based guidelines. It varies on a case?to?case basis. We report a case where the use of ECMO was beneficial after stage I Norwood palliation with severe ventricular dysfunction. The systemic?to?pulmonary artery shunt was kept open to balance the systemic and pulmonary circulations. Cerebral oximetry can be useful as an additional monitoring modality to guide management, monitor cerebral perfusion, and help detect cerebral steal.

5.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1551103

ABSTRACT

El monitoreo del contenido de humedad en el suelo es especialmente importante, ya que proporciona información relevante para tomar decisiones acertadas, en cuanto a riego, fertirriego y manejo del estrés hídrico. Este trabajo tiene como objetivo validar un modelo de estimación del contenido de agua en el suelo, mediante espectroscopía de reflectancia difusa en el rango del infrarrojo cercano. Los suelos evaluados provienen de los municipios de Puerto Gaitán (Meta), Espinal (Tolima) y Mosquera (Cundinamarca). En los dos primeros se establecieron redes rígidas, para seleccionar los puntos de muestreo y empleando dos profundidades en cada caso (0-10 y 10-30; 0-10 y 10-25 cm, respectivamente). Para el tercero, se describieron 77 calicatas y se tomaron muestras a 0-10 y 10-35 cm de profundidad. Posteriormente, se evaluó el contenido de humedad considerando 0, 15 y 30 % de humedad. Los datos obtenidos se analizaron con estadística descriptiva. Se empleó la validación cruzada y externa para cada modelo y se obtuvo un modelo general, a partir de los datos de los tres sitios. Los modelos obtenidos para cada sitio de muestreo y el modelo general tienen buena capacidad predictiva. Según los resultados, se afirma que la espectroscopía de reflectancia difusa NIR es una excelente opción para determinar el contenido de agua en el suelo. De igual manera, a partir del análisis de componentes principales, se identificó una diferenciación entre contenidos de agua de los suelos estudiados.


Monitoring soil moisture content is especially important as it provides relevant information for making informed decisions regarding irrigation, fertigation, and water stress management. This study aims to validate a model for estimating soil water content using diffuse reflectance spectroscopy in the near-infrared range. The evaluated soils come from the municipalities of Puerto Gaitán (Meta), Espinal (Tolima), and Mosquera (Cundinamarca). In the first two municipalities, rigid networks were established to select sampling points, with two depths considered for each case (0-10 and 10-30 cm; 0-10 and 10-25 cm, respectively). For the third municipality, 77 soil pits were described, and samples were taken at depths of 0-10 and 10-35 cm. Subsequently, moisture content was evaluated at 0, 15, and 30 % moisture levels. The obtained data were analyzed using descriptive statistics. Cross-validation and external validation were applied to each model, and a general model was developed based on the data from all three sites. The obtained models for each sampling site and the general model demonstrated good predictive capacity. Based on the results, it is affirmed that near-infrared diffuse reflectance spectroscopy is an excellent option for determining soil water content. Similarly, principal component analysis identified differentiation between water contents of the studied soils.

6.
Braz. J. Anesth. (Impr.) ; 73(5): 589-594, 2023. tab, graf
Article in English | LILACS | ID: biblio-1520369

ABSTRACT

Abstract Objectives: Sitting position (SP) or prone position (PP) are used for posterior fossa surgery. The SP induced reduction in cerebral blood flow and cerebral oxygen saturation (rSO2) has been shown in shoulder surgeries, but there is not enough data in intracranial tumor surgery. Studies showed that PP is safe in terms of cerebral oxygen saturation in patients undergoing spinal surgery. Our hypothesis is that the SP may improve cerebral oxygenation in the patients with intracranial pathologies due to reduction in intracranial pressure. Therefore, we compared the effects of the SP and PP on rSO2 in patients undergoing posterior fossa tumor surgery. Methods: Data were collected patients undergoing posterior fossa surgery, 20 patients in SP compared to 21 patients in PP. The rSO2 was assessed using INVOS monitor. Heart rate (HR), mean arterial pressure (MAP), EtCO2, BIS, and bilateral rSO2 were recorded preoperatively, and at 5, 8, and 11 minutes after the intubation and every 3 minutes after patient positioning until the initial surgical incision. Results: Cerebral oxygenation slowly reduced in both the sitting and prone position patients following the positioning (p < 0.002), without any difference between the groups. The HR and MAP were lower in the sitting SP after positioning compared to the PP. Conclusion: Neurosurgery in the SP and PP is associated with slight reduction in cerebral oxygenation. We speculate that if we rise the lower limit of MAP, we might have showed the beneficial effect of the SP on rSO2.

7.
Chinese Journal of Physical Medicine and Rehabilitation ; (12): 297-301, 2023.
Article in Chinese | WPRIM | ID: wpr-995197

ABSTRACT

Objective:To explore the characteristics of functional connectivity (FC) and regional spontaneous brain activity in patients in a minimally-conscious state (MCS).Methods:Resting-state functional near-infrared spectroscopy (rs-fNIRS) was used. Ten minimally-conscious patients were studied along with 12 healthy counterparts as healthy controls (HC). Five minutes of rs-fNIRS data were recorded from each subject and FC and the fractional amplitude of low-frequency fluctuations (fALFFs) of 53 channels were computed using the NIRS-KIT toolbox. The results were compared between the two groups.Results:Compared with the HC group, a significant decrease was observed in the average FC strength of seventeen channel pairs after false discovery rate (FDR) correction. Most were in the right and left frontal pole, as well as the dorsolateral prefrontal lobe. Compared with the HC group, the average fALFF values of Broca′s area (channel 2), the premotor cortex and the supplementary motor cortex (channels 4, 10, and 40), the dorsolateral prefrontal lobe (channels 6, 11, 25, 39), the eye motor area of the frontal lobe (channel 12) and the frontal pole (channels 23, 27, 36) were significantly greater in the MCS group. The fluctuations of the frontal pole (channel 19) were significantly less (after FDR correction).Conclusion:In an MCS spontaneous neural activity is over-active in the prefrontal lobe and some speech- and motor-related brain regions, and coordination of the internal prefrontal functional network is disordered.

8.
Chinese Journal of Neurology ; (12): 1084-1088, 2023.
Article in Chinese | WPRIM | ID: wpr-994937

ABSTRACT

Stroke is a cerebrovascular disease that damages brain tissue due to blockage or rupture of blood vessels, and is one of the leading causes of death and disability worldwide. Diagnosing, monitoring stroke and the treatment effects all rely on neuroimaging that detects changes in the brain. Near-infrared spectroscopy (NIRS) is a novel neuroimaging technique which is based on the non-invasively measuring of concentration changes of oxyhemoglobin and reduced hemoglobin. This review summarizes the underlying mechanisms of NIRS and its current clinical application in stroke, as well as the limitations of NIRS in broader clinical applications.

9.
Chinese Journal of Orthopaedics ; (12): 574-580, 2023.
Article in Chinese | WPRIM | ID: wpr-993478

ABSTRACT

Objective:To explore the role and value of indocyanine green (ICG) fluorescence imaging in the surgery of bone and soft tissue tumors.Methods:A total of 38 patients with bone and soft tissue tumors, including 17 males and 21 females, aged 36±21 years (range 5-75 years), who underwent resection with application of ICG-based NIR imaging were retrospectively analyzed. ICG was intravenously administrated at a dose of 2 mg/kg on the day before surgery. Intraoperative NIR imaging was performed to confirm the tumor fluorescence and to detect residual tumor after tumor resection. The NIR imaging was post hoc analyzed to explore the influence factor of tumor stain rate and SBR value.Results:Tumor staining with ICG was successful in 34 of the 38 patients, with an overall staining rate of 90%. The ICG tumor stain rate was not influenced by different pathology types, malignant or benign pathology, the reception of neoadjuvant chemotherapies or not, and the length of time between drug administration and surgery ( P>0.05). The median SBR of 34 patients with successful tumor staining was 2.9 (2.3, 5.7). Different pathological types, malignant or benign pathology, whether to receive neoadjuvant chemotherapy, preoperative ICG administration time, preoperative dose of denosumab administration in giant cell tumor of bone patients and tumor response to neoadjuvant chemotherapy had no significant effects on SBR ( P>0.05). After tumor resection, a total of 57 pieces of tissue with residual fluorescence signals were detected and resected under the fluorescence guidance, 30 of which were pathologically confirmed to contain residual tumor lesions, with an overall accuracy of 53%. The accuracy of intralesional resection was significantly higher than that of en bloc resection (71% vs. 16%, χ 2=15.51, P=0.000). Conclusion:A high percentage of bone and soft tissue tumors can be stained with ICG. The tumor stain of ICG was stable and not easily influenced by external factors. This technique was useful to detect residual tumors, especially after piecemeal resection.

10.
Chinese Journal of Experimental Ophthalmology ; (12): 812-817, 2023.
Article in Chinese | WPRIM | ID: wpr-990917

ABSTRACT

The visual signal generated by the eye receiving external light stimulation reaches the visual center through the visual pathway and is processed and integrated by the visual center to form a subjective sensation called cerebral vision.Cerebral vision reflects the function of the whole visual nervous system from the retina to the visual cortex.Abnormal cerebral vision has been found in myopes using electrophysiology, magnetic resonance imaging (MRI) and functional near-infrared spectroscopy (fNIRS). The abnormal electrophysiological results are mainly found in patients with high myopia and pathological myopia.MRI shows abnormal changes in the structure and function of several vision-related brain regions in patients with high myopia.Recently, by applying near-infrared brain function imaging technology combined with self-developed equipment, our team conducted a series of studies on the brain function of myopic patients and found that adult patients with moderate myopia and patients with pathological myopia have the abnormal cerebral vision.The mechanism of neural regulation of eye accommodation in myopic children needs further investigation.In this article, we reviewed the current status and outlook of myopic brain vision research in terms of myopia classification, myopic brain vision research methods, and myopic visual electrophysiology, MRI, and fNIRS studies.

11.
Chinese Journal of Rehabilitation Theory and Practice ; (12): 238-242, 2023.
Article in Chinese | WPRIM | ID: wpr-965037

ABSTRACT

ObjectiveTo study the brain network during balance control tasks in older adults. MethodsFrom January to April, 2022, 22 healthy young adults and 20 healthy older adults were recruited from the Fifth Affiliated Hospital of Guangzhou Medical University and communities. They were asked to finish standing tasks on the plantar pressure plate with eyes opening and closing, while the functional connectivities (FC) of prefrontal cortex (PFC) and primary motor cortex (PMC) were measured with functional near-infrared spectroscopy. ResultsCompared with the young adults, the area of the ellipse (Z = -2.884, P < 0.01) and the maximum swing (Z = -2.481, P < 0.05) increased in the older adults as eyes closing. During the standing task, the intra-FC of left (t = 2.978, P < 0.01) and right (Z = -3.123, P < 0.01) PFC decreased in the older adults, and the inter-FC of right PMC to left PFC (t = 2.087, P < 0.05) and right PFC to left PFC (t = 3.471, P < 0.001) decreased, too. ConclusionThe FC of PFC decreased in healthy older adults during balance control tasks, which may be a indicator for aging brain.

12.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 408-413, 2023.
Article in Chinese | WPRIM | ID: wpr-964441

ABSTRACT

Objective @# To investigate the application of indocyanine green in near-infrared fluorescence imaging to determine the scope of necrotic bone resection in osteoradionecrosis of the jaw and to provide a reference for clinicians@*Methods @#Eight patients with osteoradionecrosis of the jaws were enrolled. Indocyanine green was intravenously injected through the elbow vein 10 minutes before osteotomy. After conservative resection of necrotic bone lesions based on imaging results, the scope of potential dead bone resection in the area of low fluorescence intensity was gradually expanded at an initial distance of 0.3 cm. Near-infrared fluorescence imaging and fluorescence intensity determination of bone cross-section were performed before and after extended resection. Statistical differences were analyzed. All patients with osteonecrosis underwent regular follow-up to evaluate the postoperative efficacy@*Results@#Indocyanine green was injected into all 8 patients with osteoradionecrosis for near-infrared fluorescence imaging and the scans were clear; the fluorescence intensity of fresh bone wounds with an expanded mandibular resection range of (0.95 ± 0.14) cm was (226.2 ± 15.8) au, which was higher than that based on intraoperative macroscopic observation and radiological results (108.8 ± 3.4) au, (t = 20.718, P<0.001). The postoperative follow-up improvement rate of 8 patients was 87.5%.@* Conclusion @#Near-infrared fluorescence imaging with indocyanine green can assist in the successful removal of necrotic bone until fresh bleeding of the jaw wound occurs, which has important clinical value in defining the resection range of osteoradionecrosis of the jaw.

13.
Journal of Pharmaceutical Practice ; (6): 36-39, 2023.
Article in Chinese | WPRIM | ID: wpr-953756

ABSTRACT

Objective To establish a near infrared (NIR) quantitative model for the dissolution behavior of aripiprazole tablets. Methods The NIR spectra of aripiprazole tablets were collected and the dissolution tests were performed to determine the dissolution of each tablet at 3, 6, 9, 12, 15 and 30 min. The near infrared spectra regions of 4 000.00-4 396.90, 5 326.43-12 000.00 cm−1 were pretreated by Savitzky-Golay smoothing filter, and the dissolution behavior model was established by partial least squares method. Results The root mean square error of calibration (RMSEC) and the root mean square error of prediction (RMSEP) at different time points were analyzed. RMSEP was lower than 8%. The calibration correlation coefficient (RC) and the prediction correlation coefficient (RP) at different time points were above 0.95 (except for the point of 6 min). There was a good correlation between the NIR spectrum and the dissolution at each time point. Conclusion NIR spectroscopy could predict the dissolution behavior of aripiprazole tablets, which lays a foundation for online quality monitoring of tablets by NIR spectroscopy.

14.
Sichuan Mental Health ; (6): 235-241, 2023.
Article in Chinese | WPRIM | ID: wpr-986746

ABSTRACT

BackgroundFunctional near-infrared spectroscopy (fNIRS) is a new generation of imaging tool that can be used to assist the diagnosis of psychiatric disorders. However, whether the patterns of prefrontal cortex activation observed by fNIRS are specific for different psychiatric disorders remains to be explored. ObjectiveTo investigate the characteristics of prefrontal cortex activation in patients with depression, anxiety disorder, bipolar disorder and schizophrenia in verbal fluency task (VFT) using fNIRS. MethodsFrom September to December 2021, 39 patients with schizophrenia, 205 patients with depressive disorder, 212 patients with anxiety disorder and 77 patients with bipolar disorder meeting the diagnostic criteria of the Diagnostic and Statistical Manual of Mental Disorders, fifth edition (DSM-5) were recruited in the outpatient and inpatient department of West China Hospital, Sichuan University. fNIRS was used to monitor the prefrontal cortex hemodynamic changes of patients under VFT, and the clinical symptoms of patients were assessed by Symptom Checklist 90 (SCL-90) and Hypomania Checklist-32 items(HCL-32). Differences in mean oxyhemoglobin (HbO2) concentration and the initial slope from 2 to 7 second during VFT were compared among patients with different diseases, and the correlation between mean HbO2 concentration/initial slope and clinical symptoms was analyzed by partial correlation analysis. ResultsThe concentration of HbO2 in channel 4 (Z=2.828, P=0.028) and channel 6 (Z=2.912, P=0.022) in patients with depression were significantly higher than those in patients with schizophrenia. Patients with anxiety had significantly higher changes in mean HbO2 concentration in channel 4 (Z=3.154, P=0.010), channel 5 (Z=3.021, P=0.015), channel 6 (Z=2.980, P=0.017) and of all channels (Z=2.881, P=0.024) than those of schizophrenia patients. There was a statistically significant difference in the initial slope of channel 3 between patients with depressive disorder and those with bipolar disorder (Z=2.691, P=0.039). Among patients with bipolar disorder, the anger-hostility scores of SCL-90 were negatively correlated with the mean HbO2 concentration changes in channel 4 (r=-0.505, P=0.004), channel 6 (r=-0.390, P=0.004), channel 15 (r=-0.546, P=0.002), channel 16 (r=-0.550, P=0.002) and the mean HbO2 concentration changes of all channels (r=-0.491, P=0.006). ConclusionPatients with schizophrenia had lower activation in frontopolar and orbitofrontal region than patients with depression and anxiety disorder, and the initial slope of the right frontopolar, inferior frontal and orbitofrontal region in patients with depression is higher than patients with bipolar disorder. In addition, patients with bipolar disorder had less activation in the frontopolar and orbitofrontal lobe, the insular cover of Broca's area and the upper outer frontal cortex, and were more irritable and hostile. [Funded by 1·3·5 Project for Disciplines of Excellence-Clinical Research Incubation Project, West China Hospital, Sichuan University (number, ZYJC21083)]

15.
Japanese Journal of Drug Informatics ; : 196-205, 2023.
Article in English | WPRIM | ID: wpr-986263

ABSTRACT

Objective: The placebo effect can enhance the response to treatment, even in the absence of pharmacological ingredients. One possible factor explaining the likelihood of the placebo effect in individuals is genetic polymorphisms in neurotransmitters. This study focused on gene polymorphisms in the catechol-O-methyltransferase (COMT) as an interindividual variable of the placebo effect.Design・Methods: All 120 participants were explained the effects of caffeine, including its ability to ameliorate drowsiness and increase concentration, and then given a placebo (lactose). The onset of the placebo effect was measured in terms of the degree of caffeine-reduced sleepiness using subjective indices of the Stanford Sleepiness Scale (SSS) and a feeling of drowsiness-Visual Analogue Scale (VAS). The mechanism of the placebo effect was objectively examined in terms of changes in cerebral blood flow in the prefrontal cortex of the brain. In addition, we investigated participants’ susceptibility to the placebo effect by examining genetic polymorphisms in COMT.Results: After taking the drug, sleepiness on the SSS and VAS was significantly improved (p<0.001), although there was no change in prefrontal cortex activity. Among the 120 participants, 63 had a Val/Val-type polymorphism in COMT (52.5%), 45 had a Val/Met-type (37.5%), and 12 had a Met/Met-type (10.0%). There were no significant differences among COMT gene polymorphisms in the subjective measures of SSS and VAS. However, there was a tendency for the cerebral blood flow changes to be larger in the left hemisphere of the brain in individuals with the Met/Met type.Conclusion: There seems to be a relationship between prefrontal cortex activity and genetic polymorphisms. In particular, there may be a correlation between the expression of a placebo effect and COMT gene polymorphisms.

16.
Journal of Clinical Hepatology ; (12): 677-683, 2023.
Article in Chinese | WPRIM | ID: wpr-971912

ABSTRACT

Multimodality therapy based on surgery is the main treatment method for hepatocellular carcinoma (HCC), and hepatectomy requires the removal of primary tumor and the preservation of normal liver tissue to the maximum extent. However in clinical surgery, it is difficult to accurately identify tumor tissue and its boundary with visual inspection and palpation, which often results in under-resection or over-resection. Near-infrared fluorescence (NIRF) imaging is a real-time noninvasive imaging technique with low costs and high sensitivity, and extensive studies have been conducted to investigate its application in guiding surgical resection of tumors. With the development of fluorescence imaging system and fluorescence probe, intraoperative tumor localization and boundary determination can be realized to make the surgery more accurate. This article reviews the development of various NIRF probes for intraoperative navigation in HCC and discusses current challenges and potential opportunities of these imaging probes.

17.
Acta Pharmaceutica Sinica B ; (6): 1204-1215, 2023.
Article in English | WPRIM | ID: wpr-971754

ABSTRACT

Fluorescence-guided surgery (FGS) with tumor-targeted imaging agents, particularly those using the near-infrared wavelength, has emerged as a real-time technique to highlight the tumor location and margins during a surgical procedure. For accurate visualization of prostate cancer (PCa) boundary and lymphatic metastasis, we developed a new approach involving an efficient self-quenched near-infrared fluorescence probe, Cy-KUE-OA, with dual PCa-membrane affinity. Cy-KUE-OA specifically targeted the prostate-specific membrane antigen (PSMA), anchored into the phospholipids of the cell membrane of PCa cells and consequently showed a strong Cy7-de-quenching effect. This dual-membrane-targeting probe allowed us to detect PSMA-expressing PCa cells both in vitro and in vivo and enabled clear visualization of the tumor boundary during fluorescence-guided laparoscopic surgery in PCa mouse models. Furthermore, the high PCa preference of Cy-KUE-OA was confirmed on surgically resected patient specimens of healthy tissues, PCa, and lymph node metastases. Taken together, our results serve as a bridge between preclinical and clinical research in FGS of PCa and lay a solid foundation for further clinical research.

18.
Chinese Journal of Medical Instrumentation ; (6): 54-60, 2023.
Article in Chinese | WPRIM | ID: wpr-971303

ABSTRACT

In this study, a surface electromyography (sEMG) and blood oxygen signal real-time monitoring system is designed to explore the changes of physiological signals during muscle fatigue, so as to detect muscle fatigue. The analysis method of sEMG and the principle of blood oxygen detection are respectively introduced, and the system scheme is expounded. The hardware part of the system takes STM32 as the core. Conditioning module composition; blood oxygen signal acquisition is based on near infrared spectroscopy (NIRS), specifically including light source, light source driving, photoelectric conversion, signal conditioning and other modules. The system software part is based on the real-time uC/OS-III software system. The characteristic parameters of sEMG were extracted by isometric contraction local muscle fatigue experiment; the relative changes of oxyhemoglobin (HbO2) and deoxyhemoglobin (Hb) were calculated in the forearm blocking experiment, thereby verifying that the system collects two signals effectiveness.


Subject(s)
Muscle, Skeletal , Oxygen , Electromyography , Muscle Fatigue/physiology , Computers
19.
Chinese Journal of Applied Clinical Pediatrics ; (24): 198-203, 2023.
Article in Chinese | WPRIM | ID: wpr-990011

ABSTRACT

Necrotizing enterocolitis (NEC) is the most common and serious acute intestinal necrotizing disease in newborns, especially in preterm infants.Infants with smaller gestational age are more prone to NEC.NEC-related mortality reaches up to 20%-30%, and 25% of the survivors suffer from serious sequelae such as the short bowel syndrome, growth restriction and long-lasting neurological dysplasia.Due to the atypical symptoms, early diagnosis of NEC is difficult, and the patient′s condition has already been serious at the time of diagnosis in general.Ultrasound and abdominal X-ray are traditional tools for the diagnosis of NEC.Serum, urine and fecal biomarkers have been gradually applied to clinical practice in recent years.Through integrating traditional tests with biological markers and optimizing the clinical decision-making system for NEC, precise clinical diagnosis and individualized treatment can be achieved.

20.
Chinese Journal of Endocrine Surgery ; (6): 15-18, 2023.
Article in Chinese | WPRIM | ID: wpr-989889

ABSTRACT

Objective:To evaluate the excitation and identification of parathyroid autofluorescence in thyroid surgery by a fluorescence laparoscopic system.Methods:The clinical data of 6 patients with papillary thyroid carcinoma who underwent Laparoscopic thyroid surgery at the Second Affiliated Hospital of Guangxi Medical University from Mar. 2022 to Apr. 2022 were collected. The autofluorescence of the parathyroid glands was detected and identified by the OptoMedic fluorescence laparoscopic system during the operation. A rapid frozen sections pathological examination of possible parathyroid tissue with autofluorescence was performed to determine whether it was parathyroid tissue.Results:Parathyroid autofluorescence with different intensities was visualized intraoperatively in all 6 patients, and it was confirmed as parathyroid tissue by rapid frozen pathological section.Conclusions:The parathyroid gland has a unique autofluorescence feature. Using this feature to identify, locate and protect the parathyroid gland during surgery can help reduce the complications of parathyroid injury.