1.
Chinese Journal of Radiation Oncology ; (6): 389-393, 2019.
Article in Chinese | WPRIM | ID: wpr-745318

ABSTRACT

Surgery,radiotherapy and chemotherapy are three traditional treatments for malignant tumors.With the development of medicine,immunotherapy has been gradually adopted as an emerging therapy of malignancies.Recent clinical studies have demonstrated that the combination of radiotherapy and immunotherapy can induce the abscopal effect and improve the prognosis of patients.Compared with the conventional radiotherapy,stereotactic radiotherapy has a larger single dose and higher accuracy,which is more likely to induce the bystander effect and anti-tumor response.The combination of stereotactic radiotherapy and immunotherapy has been proven to be a more promising therapy in certain clinical trials.However,not all types of tumors can benefit from such combined therapy in clinical practice.The optimal dose,fraction pattern and lesion of radiotherapy,immune enhancement and safety remain to be further clarified.In this article,the research progress,related controversies and future research direction of stereotactic radiotherapy combined with immunotherapy for malignancies were reviewed.

2.
Chinese Journal of Radiation Oncology ; (6): 749-752, 2018.
Article in Chinese | WPRIM | ID: wpr-807141

ABSTRACT

Objective@#To evaluate the clinical efficacy and side effects of cyberknife therapy in the treatment of retroperitoneal lymph node metastatic tumor.@*Methods@#Among the 81 patients presenting with postoperative retroperitoneal lymph node metastases, 33 cases suffered from abdominal pain or low back pain, 7 had unilateral hydronephrosis and ureteral dilatation, and 8 developed unilateral or bilateral lower limb swelling. Using stereotactic radiotherapy with a cyberknife, DT was delivered at 33-45 Gy/3-6 F. The improvement of symptoms, objective tumor response rate, and irradiation-induced side effects were observed.@*Results@#At 4 weeks after treatment, pain and swelling of the lower extremities were completely mitigated, and hydronephrosis was fully healed in all patients. Enhanced CT or MRI was performed every 2 to 3 months. After 6-month follow-up, the complete response (CR) rate was calculated as 77%(62/81), 21%(17/81) for the partial response (PR) rate, 3%(2/81) for the stable disease (SD) rate and the effective rate (CR+ PR) was 98%.No case progressed. The main side effect was intestinal injury, including grade 1 in 16%(13/81), grade 2 in 9%(7/81). Multivariate analysis demonstrated the CR rate was not correlated with the type of the primary tumor or the size of the tumor (P>0.05), but was significantly associated with the distance of>0.5 cm between the tumor and intestine and the BED (α/β=10)>70 Gy of the tumor irradiation (P<0.01). The incidence of irradiation-related side effects was correlated with the maximum diameter of tumor>5 cm and the distance of<0.5 cm between the tumor and intestine (P<0.01).@*Conclusion@#Cyberknife is an efficacious and safe approach in the treatment of retroperitoneal lymph node metastatic tumors.

3.
Chinese Journal of Radiation Oncology ; (6): 295-298, 2018.
Article in Chinese | WPRIM | ID: wpr-708184

ABSTRACT

Objective To investigate the utilization rate of gold fiducial markers and reasons for abandonment of gold fiducial markers in the CyberKnife VSI System, and to provide reference data for implantation of gold fiducial markers and radiotherapy planning. Methods From March to August,2017,a total of 47 patients had gold fiducial markers implanted or pasted. In those patients, 42 patients had gold fiducial markers implanted,including 32 receiving computed tomography(CT)-guided 3D-printing coplanar template assisted implantation, 1 receiving CT-guided 3D-printing non-coplanar template assisted implantation,1 receiving CT-guided implantation,and 8 receiving ultrasound-guided implantation. A total of 44 patients received the CyberKnife treatment, including 2 patients who failed to use gold fiducial markers and were treated with spine tracking instead and 3 patients missing the treatment for other reasons. The numbers of utilized and abandoned gold fiducial markers were recorded for calculation of the utilization and abandonment rates. The reasons for abandonment of gold fiducial markers were analyzed and classified. Results A total of 134 gold fiducial markers were implanted into or pasted to the 44 patients.In all the gold fiducial markers, 111 were utilized and 23 abandoned, yielding a utilization rate of 82.8% and an abandonment rate of 17.2%.The reasons for abandonment of gold fiducial markers included large rigidity error(26.1%), unqualified implanted fold fiducial markers(17.4%), displacement of gold fiducial markers(26.1%), and others(30.4%). Conclusions Compared with the CT-guided or ultrasound-guided implantation of gold fiducial markers, the CT-guided 3D-printing coplanar or non-coplanar template assisted implantation of gold fiducial markers requires only two puncture needles for each implantation and implants two gold fiducial markers by a single needle,which reduces the number of puncture needles,risk of puncture-induced injury,and incidence of complications after implantation. Not all the gold fiducial markers implanted by a variety of ways will be utilized. Some gold fiducial markers will be abandoned for different reasons,which should be taken into account during implantation of gold fiducial markers.

4.
Chinese Journal of Radiation Oncology ; (6): 177-180, 2018.
Article in Chinese | WPRIM | ID: wpr-708162

ABSTRACT

Objective To evaluate the efficacy and safety of CyberKnife stereotactic body radiation therapy (SBRT) in the treatment of hepatic hilar cancer.Methods A retrospective study was performed on the clinical data of 36 patients with hepatic hilar cancer who were admitted to our hospital and treated with CyberKnife SBRT from 2009 to 2015.In the 36 patients,37 lesions were found with tumor diameters ranging from 1.5 to 5.5 mm (median diameter 3 cm).The Synchrony respiratory tracking system was used for 21 lesions in 20 patients,while the XSight spinal tracking system was used for 16 lesions in 16 patients.Local progression was evaluated based on contrast-enhanced computed tomography and/or magnetic resonance imaging.The Kaplan-Meier method was used to calculate local control (LC) and overall survival (OS) rates,and the log-rank test was used for survival comparison and univariate prognostic analysis.Results The median follow-up time was 12.7 months.The 1-and 2-year postoperative LC rates were 90% and 76%,respectively.The 1-year OS and progression-free survival (PFS) rates were 63% and 39%,respectively.The median OS and PFS times were 15.2 and 10 months,respectively.The incidence of grade 3 adverse reactions was 11%.Conclusions The CyberKnife SBRT is a safe and effective way to treat hepatic hilar cancer.

5.
Chinese Journal of Radiation Oncology ; (6): 763-767, 2017.
Article in Chinese | WPRIM | ID: wpr-620220

ABSTRACT

Objective To examine the effects of gross tumor volume (GTV) and radiation dose on the prognosis of hepatocellular carcinoma (HCC) patients treated with whole body gamma knife.Methods The clinical data of 69 HCC patients who underwent body gamma knife treatment from January 2012 to June 2015 in the Radiotherapy Center of the PLA General Hospital were retrospectively reviewed.Based on a 50% or 60% isodose coverage of the planning target volume (PTV), patients were treated with a radiation dose of 4-5 Gy per fraction, and a total marginal dose of 36-50 Gy (median dose 45 Gy).Short-term efficacy, overall survival (OS), and the adverse effect of the treatment were evaluated.The optimal cut-off tumor volume was identified using the receiver operating characteristic curve, and survival was determined by the Kaplan-Meier method.Univariate and multivariate analyses were performed using the log-rank test and Cox proportional hazards regression model, respectively.Results The overall short-term response rate of the 69 patients was 67%.The 1-and 2-year OS rates were 62% and 40%, respectively, with a median survival of 18.6 months.The multivariate analysis showed that gross tumor volume (GTV)93 cm3(P=0.665).Conclusions GTV is an independent prognostic factor for overall survival of HCC patients.Although high-dose radiotherapy provides survival benefits to patients with small GTV, it is not necessarily suitable for patients with large GTV.

6.
Chinese Journal of Radiation Oncology ; (6): 180-183, 2008.
Article in Chinese | WPRIM | ID: wpr-401428

ABSTRACT

Objective To study the efficacy and toxicity of the cyberknife in the treatment of medically inoperable patients with early stage lung cancer. Methods From September 2006 to July 2007,17 patients with clinical stage Ⅰ a- Ⅰ b lung cancer were treated with cyberknife at Tianjin Cancer Hospital. Of the 11 patients receiving CT guided biopsy, 3 were squamous cell cancer and 8 were adenocarcinoma. Six patients refused intrusive operation and were diagnosed by PET-CT scan. All patients were medically inoperable evaluated by a thoracic surgeon. The PTV = GTV + 3 ~ 5 mm, and the median volume of PTV was 36 cm3 (6-82 cm3 ). The median total prescription dose was 50 Gy(45-60 Gy) at 3-5 fractions. Results The median follow-up time was 7 months (3-11 months). All the patients finished the treatment and were alive by the last follow-up. Slight fatigue was the most common complain. Evaluated by CT scan, 13 were complete response and 4 were partial response. No recurrence, progression or distant metastasis occured. There were 3 patients with grade Ⅰ granulocytopenia,3 grade Ⅰ pneumonitis and 1 grade Ⅱ pneumonitis. Conclusions The cyberknife radiosurgery treatment in early stage lung cancer shows a high rate of local control and minimal toxicity. Long time follow-up is necessary to evaluate the survival data and late toxicity.