Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add filters








Year range
1.
Chinese Journal of Internal Medicine ; (12): 304-309, 2023.
Article in Chinese | WPRIM | ID: wpr-994408

ABSTRACT

Objective:To investigate the safety and effectiveness of Neuroform Atlas stent-assisted coiling in the endovascular treatment of intracranial aneurysms.Methods:This was a retrospective, single-center observational study of 77 patients who underwent endovascular treatment of intracranial aneurysms using the Neuroform Atlas device at the Department of Neurology, People′s Liberation Army General Hospital from July 2020 to May 2022. There were 34 males and 43 females, with a median (range) age of 59 (23-81) years. The degree and effect of aneurysm embolization were evaluated by modified Raymond grading post procedure and after 6 months. Complications occurring during the perioperative period were recorded. Vaso computed tomography was performed immediately after the operation to assess stent opening and adherence. Digital subtraction angiography was performed 6 months after discharge and the aneurysm was classified as cured, stable, or recurrent.Results:A total of 87 Atlases were successfully released in 77 cases. Angiography performed immediately after the embolization revealed 19 (24.7%) modified Raymond grade Ⅰ, 10 (13.0%) grade Ⅱ, and 48 (62.3%) grade Ⅲa cases. Three perioperative complications were observed including thrombotic events in 2 cases and stent migration in 1 case. A follow-up angiogram was available for 47 aneurysms, and showed that modified Raymond grade Ⅰ occlusion was achieved in 38 (80.9%) cases, grade Ⅱ in 2 (4.3%) cases, and grade Ⅲa in 7 (14.9%) cases. At the 6-month follow-up, 38 patients were cured and 7 were stable, whereas 2 patients experienced a recurrence of aneurysm. Stenosis of the parent artery occurred in 3 (6.4%) cases, including 2 at the head and 1 inside the stent.Conclusions:The results of this preliminary study suggest that Neuroform Atlas stent-assisted coiling has a high occlusion rate and low incidence of complications in the endovascular treatment of aneurysms. However, the effectiveness of this procedure for large aneurysms and long-term outcomes require further investigation.

2.
Journal of Peking University(Health Sciences) ; (6): 139-143, 2023.
Article in Chinese | WPRIM | ID: wpr-971286

ABSTRACT

OBJECTIVE@#To assess the safety and efficacy of Neuroform Atlas stent used in treatment of unruptured wide-neck intracranial aneurysms.@*METHODS@#Clinical data of 62 patients with unruptured wide-neck intracranial aneurysms undergoing Neuroform Atlas stent-assisted coiling from August 2020 to September 2021 were retrospectively analyzed. There were 64 aneurysms in those 62 patients. Among them, 25 aneurysms were located at the bifurcation of M1 segment on middle cerebral artery, 16 at the anterior communicating artery, 10 at the C7 segment of internal carotid artery, 5 at the C6 segment of internal carotid artery, 4 at the apex of basilar artery, 3 at the A3 segment of anterior cerebral artery, and 1 at the M2 segment of middle cerebral artery. All the patients underwent Neuroform Atlas stent-assisted coiling, including 49 patients with single stent assisted coiling and 15 patients with dual stents assisted coiling (14"Y"style and 1"X"style). After the procedure, the immediate DSA was performed to evaluate the status of aneurysm occlusion and the parent artery patency. The clinical follow-up was performed 3 months after the operation and evaluated based on the modified Rankin Scale(mRS).DSA image was reviewed at 6 months after operation and Raymond grading scale was used to assess the status of aneurysm occlusion and the parent artery patency.@*RESULTS@#A total of 62 patients with 64 aneurysms were all achieved technical success(100%).The immediate post-procedural Raymond scale was assessed, including Raymond Ⅰ in 57 aneurysms(89.1%, 57/64), Raymond Ⅱ in 6 aneurysms(9.3%, 6/64) and Raymond Ⅲ in 1 aneurysm(1.6%, 1/64). The peri-procedural complications rate was 4.8%(3/62), 2 patients developed intraoperative thrombosis and 1 patient suffered from local subarachnoid hemorrhage. Among them, 55 patients obtained 3 months clinical follow-up after operation and all the patients had good outcomes (mRS≤2), 50 patients with 52 aneurysms were followed up with DSA 6 months after operation, including Raymond Ⅰ in 45 aneurysms(86.5%, 45/52), Raymond Ⅱ in 4 aneurysms(7.7%, 4/52) and Raymond Ⅲ in 3 aneurysms(5.8%, 3/52).@*CONCLUSION@#Neuroform Atlas stent for the treatment of unruptured wide-neck intracranial aneurysms has high safety and good efficacy, and has its advantages over other traditional stents.


Subject(s)
Humans , Intracranial Aneurysm/etiology , Retrospective Studies , Treatment Outcome , Embolization, Therapeutic/methods , Stents/adverse effects , Cerebral Angiography
3.
Journal of Cerebrovascular and Endovascular Neurosurgery ; : 293-298, 2013.
Article in English | WPRIM | ID: wpr-199444

ABSTRACT

OBJECTIVE: An open cell stent system may offer better apposition of cell struts to vessel wall than a closed cell stent system in acute vasculature. The purpose of this study was to evaluate the feasibility of coiling using the jailing technique with the Neuroform EZ stent system. METHODS: The jailing technique using the open-cell stent system of the Neuroform EZ stent was planned in 22 consecutive patients with 22 cerebral aneurysms. We retrospectively evaluated the technical success of the jailing technique and the occurrence of interference between two microcatheters as well as the factors influencing this interference. RESULTS: The jailing technique was successful in 19/22 patients (86.4%), and interference between two microcatheters occurred in 6/21 (28.6%). The jailing technique failed in 3/22 patients, with problems that included failure of the stent delivery system to advance into the positioned microcatheter in one, interference between the microcatheters during the advancement of the stent delivery system in one, and failure of microcatheter insertion into the aneurysm sac in the remaining patient. Interference between the two microcatheters developed during the advance of the stent delivery system into the positioned microcatheter in all cases. One factor that influences interference between two microcatheters more than expected by chance is the carotid siphon angle (p = 0.019). CONCLUSION: The acuteness of the carotid siphon angle influences the interference between two microcatheters. Therefore, the jailing technique using the Neuroform EZ stent should be performed carefully in cerebral aneurysms with an acute carotid siphon angle because the procedure may possibly fail.


Subject(s)
Humans , Aneurysm , Carotid Artery, Internal , Intracranial Aneurysm , Retrospective Studies , Stents
4.
Neurointervention ; : 101-104, 2013.
Article in English | WPRIM | ID: wpr-730211

ABSTRACT

The Neuroform EZ Stent System is a fourth generation intracranial aneurysm stent that utilizes an integrated navigation guidewire. While designed to facilitate stent delivery, the guidewire can rarely impede proper positioning of the stent. In this technical case report, severing the guidewire from the stent delivery system with surgical scissors was required for successful stent implantation.


Subject(s)
Aneurysm , Intracranial Aneurysm , Stents , Surgical Instruments
5.
Journal of Cerebrovascular and Endovascular Neurosurgery ; : 247-250, 2012.
Article in English | WPRIM | ID: wpr-207519

ABSTRACT

Use of stent assisted coiling of intracranial aneurysms has shown a recent increase. Despite technical improvement and accumulated clinical experiences, due to insufficient study data, debate over short and long term durability and associated complication has continued. To the best of our knowledge, this case report, for the first time, demonstrates delayed self-expansion phenomenon occurring as an acute and unpredictable complication of Neuroform stent assisted coiling for treatment of a ruptured intracranial aneurysm.


Subject(s)
Intracranial Aneurysm , Stents
6.
Neurointervention ; : 34-39, 2012.
Article in English | WPRIM | ID: wpr-730240

ABSTRACT

PURPOSE: Stent-assisted coiling allows embolization and parent vessel reconstruction of wide-necked intracranial aneurysms. The Neuroform EZ (Boston Scientific, Fremont, CA, U.S.A.) stent delivery system offers deployment of a Neuroform stent with fewer steps and improved operator control. Initial experience, technical considerations, and treatment outcomes using the Neuroform EZ stent delivery system in combination with coil embolization are reported. MATERIALS AND METHODS: Seventeen consecutive patients harboring 21 wide-necked saccular cerebral aneurysms were treated with stent reconstruction. Twenty aneurysms were unruptured; one was treated within 24 hours of diagnosis of rupture. Twenty aneurysms were located in the anterior circulation; one was in the posterior circulation. Immediate and six-month post-treatment angiography and clinical assessment were performed. RESULTS: In all cases, the stents were delivered and positioned without difficulty in deployment. Technical complications occurred in 4 patients, but none were directly related to the stent delivery system. On immediate post-treatment angiography, 5 of 21 aneurysms showed complete occlusion, 5 of 21 showed residual neck, and 11 of 21 showed residual contrast filling of the aneurysm sac. At six month follow-up, all 17 patients were clinically stable. Angiography of 18 of the aneurysms showed total occlusion in 12, residual neck in 3, and residual aneurysm filling in 3. Retreatment was performed in the three with residual aneurysm. CONCLUSION: The Neuroform EZ stent system offers improved anchoring and support in stent delivery, which is particularly useful when multiple stents are overlapped to further protect the parent vessel and increase flow diversion away from the aneurysm sac. The only significant problem encountered was coil prolapse, which could be treated with a second stent when necessary. The ease of deployment improves upon the already clinically successful Neuroform design.


Subject(s)
Humans , Aneurysm , Angiography , Follow-Up Studies , Glycosaminoglycans , Intracranial Aneurysm , Neck , Parents , Prolapse , Retreatment , Rupture , Stents
7.
Journal of Korean Neurosurgical Society ; : 116-119, 2011.
Article in English | WPRIM | ID: wpr-13626

ABSTRACT

The surgical as well as endovascular treatment of blood-blister-like aneursysms (BBAs) is extremely difficult because of these pathological natures, such as small and the fragile necks. The optimal treatment of BBAs has remained uncertain. Stents are known to divert blood flow and induce thrombosis of intracranial aneurysms. We report 3 cases of successful obliteration of BBAs after multiple stents placement.


Subject(s)
Aneurysm , Intracranial Aneurysm , Neck , Stents , Thrombosis
8.
Journal of Korean Neurosurgical Society ; : 53-58, 2010.
Article in English | WPRIM | ID: wpr-114539

ABSTRACT

OBJECTIVE: The purpose of this study was to review the safety and durability of aneurysms treated with stent-assisted coiling of ruptured anterior communicating artery aneurysms with small parent vessels (< 2.0 mm). METHODS: Retrospective review of all ruptured aneurysm treated with stent assisted endovascular coiling between March 2005 and March 2009 at our institution was conducted. We report 11 cases of the Neuroform stent placement into cerebral vessels measuring less than 2.0 mm in diameter (range, 1.3-1.9 mm) in anterior cerebral artery. Clinical follow-up ranged from 3 to 12 months and imaging follow-up was performed with cerebral angiography at 6 months and 12 months after discharge. RESULTS: Complete occlusion was achieved in 10 patients, and a remnant neck was evident in one. No stent displacement or no dislodgement occurred during stent placement. There was no evidence of thromboembolic complication, arterial dissection and spasm during procedure. We performed follow-up angiography in all patients at 6 months and/or 12 months from the first procedure. The follow-up angiographic data showed successfully results except one in-stent stenosis case. All patients improved clinical performances except one patient with severe vasospasm who showed poor clinical condition initially. CONCLUSION: We have safely and successfully treated 11 vessels smaller than 2.0 mm in diameter with self-expanding stents with good short and intermediate term results. More clinical data with longer follow-ups are needed to establish the role of stent-assisted coiling in ruptured aneurysms with small parent vessels.


Subject(s)
Humans , Aneurysm , Aneurysm, Ruptured , Angiography , Anterior Cerebral Artery , Cerebral Angiography , Constriction, Pathologic , Displacement, Psychological , Follow-Up Studies , Glycosaminoglycans , Intracranial Aneurysm , Neck , Parents , Retrospective Studies , Spasm , Stents
9.
Chinese Journal of Postgraduates of Medicine ; (36): 15-17, 2009.
Article in Chinese | WPRIM | ID: wpr-394950

ABSTRACT

Objective To investigate the efficacy, technical tip, safety and complication prevention of combining Neuroform stents and Guglielmi detachable coils for treating acute ruptured giant intracranial aneurysms. Methods Among 10 cases who were diagnosed with giant intracranial aneurysms,Neuroform stents were released for supporting the neck of aneurysms, then micro-catheters were inserted into aneurysms through lumina of stents and coils were implanted. Results All the operations were completed successfully. There was no complication in these cases. The aneurysms were packed totally in 9 cases and partly in 1 case.Eight postoperative cases were followed up by 6 to 17 months. Neither bleeding nor thrombus was found, and all the patients recovered well. Conclusion Combining Neuroform stents and Guglielmi detachable coils for treating acute ruptured giant intracranial aneurysms is a safe and effective method.

SELECTION OF CITATIONS
SEARCH DETAIL