Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Archives of Orofacial Sciences ; : 67-72, 2021.
Article in English | WPRIM | ID: wpr-962459

ABSTRACT

ABSTRACT@#Currently dental implant treatment become popular. More clinicians are being presented with the opportunity to perform implant services in their own practice. The use of one-piece implant can be considered as treatment for the replacement of missing tooth in the areas of limited tooth-to-tooth spacing and would bring less trauma for the soft tissue. A 52-year-old female patient presented with difficulty in mastication due to the loss of teeth of 35 region with limitation mesio distal space. Radiology examination did not reveal any radiolucencies in 35 region. Radiograph revealed sufficient bone height from crestal to the floor of the mandible. A one-piece implant was placed in the 35 region. The present case used an endosteal implant, one stage surgery, and delayed loading. Restoration with porcelain fused to the metal crown had been delivered three months after the one-piece implant placement. The result of this treatment indicated that one-piece implant could be considered as an effective therapy choice for replacement of missing tooth in order to rehabilitate the masticatory function.


Subject(s)
Dental Implantation
2.
The Journal of Korean Academy of Prosthodontics ; : 346-353, 2011.
Article in Korean | WPRIM | ID: wpr-116128

ABSTRACT

PURPOSE: The peri-implant soft tissue is remodeled by the initial marginal bone resorption affecting the prognosis and esthetic result of treatment. Thus various designs on implant neck design are studied to preserve peri-implant bone. The purpose of this study is to review on the causes of initial marginal bone resorption, the configuration of peri-implant soft tissue, and the implant crestal module favorable in preserving peri-implant tissue. MATERIALS AND METHODS: The studies on the causes of initial marginal bone resorption and the implant crestal modules are researched and reviewed using Pubmed database. The implant crestal modules including one piece and two-piece implant, internal and external hex abutment, taper and butt joint connection, scalloped design abutment, and platform switching concept are reviewed. RESULTS: A number of clinical and experimental studies preferred one piece implant to two-piece in preserving initial peri-implant tissue. For two piece implants, internal hex abutment and taper joint connection appear more favorable than external hex abutment and butt joint connection relatively. Controversial issues still exist on scalloped design requiring more studies on it. Although the rationale is not certain, the concept of platform switching seems favorable in preserving initial peri-implant tissue based on clinical and experimental studies. CONCLUSION: Each implant crestal module contains its own advantages and disadvantages with various controversial issues. In the aspect of preservation of initial peri-implant tissue, however, one-piece implant seems beneficial. In cases when two-piece implant is more appropriate due to prosthodontic concerns or any other problems, the application of platform switching concept, internal connection abutment, and taper joint connection may be favorable for the preservation of peri-implant tissues.


Subject(s)
Bone Resorption , Joints , Neck , Pectinidae , Prognosis , Prosthodontics
3.
The Journal of Korean Academy of Prosthodontics ; : 394-405, 2009.
Article in Korean | WPRIM | ID: wpr-153199

ABSTRACT

STATEMENT OF PROBLEM: Crestal bone loss, a common problem associated with dental implant, has been attributed to excessive bone stresses. Design of implant's transgingival (TG) part may affect the crestal bone stresses. PURPOSE: To investigate if concavely designed geometry at a dental implant's TG part reduces peri-implant bone stresses. MATERIAL AND METHODS: A total of five differently configured TG parts were compared. Base model was the ITI one piece implant (Straumann, Waldenburg, Switzerland) characterized by straight TG part. Other 4 experimental models, i.e. Model-1 to Model-4, were designed to have concave TG part. Finite element analyses were carried out using an axisymmetric assumption. A vertical load of 50 N or an oblique load of 50 N acting at 30degrees with the implant's long axis was applied. For a systematic stress comparison, a total of 19 reference points were defined on nodal points around the implant. The peak crestal bone stress acting at the intersection of implant and crestal bone was estimated using regression analysis from the stress results obtained at 5 reference points defined along the mid plane of the crestal bone. RESULTS: Base Model with straight configuration at the transgingival part created highest stresses on the crestal bone. Stress level was reduced when concavity was imposed. The greater the concavity and the closer the concavity to the crestal bone level, the less the crestal stresses. CONCLUSION: The transgingival part of dental implant affect the crestal bone stress. And that concavely designed one may be used to reduce bone stress.


Subject(s)
Axis, Cervical Vertebra , Dental Implants , Finite Element Analysis , Models, Theoretical
SELECTION OF CITATIONS
SEARCH DETAIL