Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Arq. bras. oftalmol ; 77(4): 267-270, Jul-Aug/2014. graf
Article in English | LILACS | ID: lil-728660

ABSTRACT

Some intriguing concepts of visual optics cannot be explained by ray tracing. However, they can be clarified using wavefront formalism. Its main advantage is in the use of the concept of vergence, which is very helpful in interpreting the optical phenomena involved in the neutralization of the ametropias. In this line of thinking, the major role of a lens is in the creation of a new light source (the image point) that orientates the refracted waves. Once the nature and position of this source is known, one can easily predict the behavior of the wavefronts. The formalism also allows for an easier understanding on how wavefronts relate to light rays and on how algebraic signs are assigned to optical distances.


Alguns conceitos intrigantes da óptica visual não podem ser explicados pelo traçado dos raios luminosos. Entretanto, eles podem ser esclarecidos através do formalismo da frente de onda. A vantagem do mesmo está no uso do conceito de vergência, que facilita o entendimento dos fenômenos ópticos envolvidos na neutralização das ametropias. Nessa linha de raciocínio, a principal função de uma lente é o de criar de uma nova fonte de luz - o ponto de imagem - que orienta as ondas refratadas. Conhecendo-se a natureza e a posição dessa fonte pode-se facilmente prever o comportamento das frentes de onda. Este formalismo também ajuda a compreensão de como as frentes de onda se relacionam com os raios de luz e como os sinais algébricos são atribuídos às distâncias ópticas.


Subject(s)
Humans , Refraction, Ocular/physiology , Refractive Errors/diagnosis , Models, Theoretical , Optics and Photonics
2.
Arq. bras. oftalmol ; 76(1): 33-37, jan.-fev. 2013. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-678159

ABSTRACT

OBJETIVO: Avaliar por deflexometria as diferentes regiões das lentes progressivas e determinar as áreas dos campos de visão intermediário e de perto. MÉTODOS: Foram incluídas vinte e duas lentes progressivas com poder +1,00 DE para longe e duas adições diferentes (adição 1,00 e 2,00, 11 de cada). Mediram-se as áreas dos campos intermediário e de perto entre as isoastigmáticas de 0,5 DC. RESULTADOS: Encontraram-se diferenças significativas entre as áreas dos campos intermediário e de perto das lentes estudadas. Entre a área do campo intermediário e a adição observou-se correlação inversa; entre a área do campo intermediário e a extensão vertical do corredor encontrou-se correlação direta. CONCLUSÃO: Com esses dados permitem-se recomendar as lentes de acordo com o campo de maior necessidade visual de cada usuário.


PURPOSE: To determine near and intermediate vision areas of progressive addition lenses by means of a deflectometer. METHODS: Twenty-two progressive addition lenses with +1.00 SD far power and two different additions (add 1.00 and 2.00; eleven subjects in each addition) were studied. Near and intermediate vision areas within 0.50 CD isoastigmatic lines were determined. RESULTS: There are significant differences between near and intermediate vision areas of the studied lenses. There is also an inverse correlation between the addition and intermediate areas as well as direct relation between the vertical length of the corridor and its area. CONCLUSION: Based on those findings, progressive addition lenses can be selected to suit the wearer's visual requirements.


Subject(s)
Eyeglasses/standards , Optical Phenomena , Equipment Design , Interferometry/methods
3.
Article in Portuguese | LILACS | ID: lil-583292

ABSTRACT

Introdução: Alguns dos fatores determinantes na resposta fotobiológica da terapia laser em baixa intensidade são o estado fisiológico do tecido e as características ópticas do feixe, como a polarização de seu campo elétrico. Objetivos: Investigaram-se o grau e a preservação da polarização linear em amostras de pele de rato sadia e lesionada. Métodos: Criolesões foram realizadas no dorso de ratos e tratadas por quatro dias com 1J/cm2. O campo elétrico do laser foi alinhado a 0º e a 90º em relação à coluna vertebral dos animais. Resultados: A polarização foi mantida nas camadas superficiais da pele, sendo mais preservada na pele queimada. Durante o processo cicatricial, a lesão cujo campo elétrico foi alinhado a 0º em relação à coluna vertebral mostrou um grau de polarização semelhante àquele da pele sadia. Conclusões: O processo de reparação da pele foi influenciado pela polarização linear do feixe laser de He-Ne.


Introduction: The physiological conditions of tissue and optical characteristics of beam, like electric polarization, are some of the determining factors in the photobiological response of low intensity laser therapy. Objectives: The degree and preservation of linear polarization in samples of healthy and injured rat skin were investigated. Methods: Cryolesions were created in the lower back of rats and treated for four days with 1J/cm2. The laser electric was aligned in 0º and 90º to the backbone of the animals. Results: The polarization was maintained in the superficial layers of the skin, being better preserved in burned skin. During the wound healing, the lesion whose electric was aligned parallel to the spine showed a degree of bias similar to that of healthy skin. Conclusions: The repair process of skin was influenced by linear polarization of He-Ne laser beam.


Subject(s)
Animals , Male , Rats , Wound Healing , Low-Level Light Therapy , Rats, Wistar , Optics and Photonics
SELECTION OF CITATIONS
SEARCH DETAIL