Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Year range
1.
Rev. habanera cienc. méd ; 12(1): 48-56, ene.-mar. 2013.
Article in Spanish | LILACS | ID: lil-670221

ABSTRACT

Introducción: la Toxoplasmosis Ocular (TXO) congénita es la causa más frecuente de uveítis posterior (retinocoroiditis) de etiología conocida. El deterioro visual ocurre si se afecta la mácula por la necrosis o por secuelas de la inflamación, en raras ocasiones la afectación bilateral convierte al paciente en un débil visual. Objetivo: demostrar que la rehabilitación visual con ayudas ópticas es el proceder más indicado para lograr una mayor calidad visual siempre que exista una motivación positiva del paciente. Presentación del caso: paciente femenina de 42 años de edad con baja visión severa de cerca y lejos en ambos ojos (AO) que no mejoraba con su corrección convencional imposibilitándole realizar diversas actividades. Conclusiones: la rehabilitación se realizó en tres consultas con una duración cada una de hora y media posibilitando alcanzar una agudeza visual de 0.8 en OD y 1.0 en OI para lejos con telescopio enfocable monocular (ts) 6x y de 0.6 OI para cerca con el uso de hipercorrección de +10.00 con OD ocluido. Al mes y medio de rehabilitada, refirió nueva motivación teniendo en cuenta la mejoría de su agudeza visual para cerca.


Introduction: ocular Toxoplasmosis (TXO), congenital, is the most common cause of posterior uveitis (retinochoroiditis) of known etiology. If the macula is affected by necrosis or by the effects of inflammation, visual impairment occurs, in rare situations bilateral affection carry the patient in a visual impairment. Objective: to show that visual rehabilitation with optical aids and positive motivation of the patient is the most appropriate method to achieve the best visual quality. Case presentation: a 42-year female patient with severe low vision near and far in both eyes (AO). The patient did not improve with conventional correction. Conclusions: the rehabilitation was performed in 3 sessions of 90 minutes, making it possible to achieve a visual acuity of 0.8 OD and 1.0 in OI to far with Focusable Monocular Telescope (ts) 6x and 0.6 OI to close using overcorrection of 10.00 with OD occluded. The patient, a month and a half after rehabilitation, said new motivation considering the improvement in the visual acuity for near.

2.
Rev. cuba. oftalmol ; 23(1): 156-168, ene.-jun. 2010.
Article in Spanish | LILACS | ID: lil-584992

ABSTRACT

OBJETIVOS: Evaluar el comportamiento de la retinopatía de la prematuridad, determinar los trastornos refractivos más frecuentes así como las ayudas ópticas más utilizadas en la rehabilitación visual y evaluar los resultados visuales alcanzados. MÉTODOS: Se realizó un estudio descriptivo, en pacientes con retinopatía de la prematuridad atendido en el Servicio de Baja Visión del Instituto Cubano de Oftalmología Ramón Pando Ferrer (2005-2007). Las variables utilizadas para el estudio fueron: sexo, color de la piel, edad gestacional, peso al nacer, duración del oxígeno, estadio de la retinopatía de la prematuridad , complicaciones, tratamiento realizado, ayuda óptica utilizada, trastornos refractivos y resultado visual alcanzado. RESULTADOS: En nuestro estudio se encontró mayor frecuencia de ROP en el sexo masculino, el color blanco de la piel aportó un mayor número de pacientes, los factores de riesgo más relevantes fueron la prematuridad por debajo de las 32 semanas, el bajo peso al nacer inferior a los 1 500 g además del distress respiratorio y la administración de oxígeno, el mayor número de casos se encontró en el estadio 3, el defecto refractivo más frecuente fue la miopía, las ayudas ópticas más utilizadas fueron la corrección convencional (cristales montados en gafas) para lejos y los microscopios para cerca. Un alto por ciento de los pacientes se benefició con la rehabilitación de su baja visión. CONCLUSIONES: Este estudio muestra el alto porcentaje de pacientes que se benefician con la rehabilitación de su baja visión y confirma los resultados obtenidos por otros investigadores. La corrección convencional (cristales montados en gafas) fue la ayuda óptica más utilizada para lejos. El microscopio fue la ayuda óptica para cerca más representativa en nuestro grupo de estudio


OBJECTIVES: To evaluate the situation of retinopathy of prematurity, to determine the most common refractive disorders as well as the most used optical aids in visual rehabilitation and to evaluate the achieved visual outcomes. METHODS: A descriptive study was conducted in patients with retinopathy of prematurity seen at the Low Vision Service of Ramón Pando Ferrer Cuban Institute of Ophthalmology in the 2005-2007 period. The study variables were sex, race, gestational age, birth weight, duration of oxygen, stage of retinopathy of prematurity, complications, treatment, optical aid, refractive disorders and visual outcomes. RESULTS: Our study found that retinopathy of prematurity was more frequent in males; race contributed the highest number of patients, the most relevant risk factors were prematurity under 32 weeks, low birth weight under 1 500g, respiratory distress and oxygen administration; the highest number of cases occurred in staging 3, the most frequent refractive defect was myopia, the most used optical aids were conventional correction (glasses) for far sight and microscopes for near sight. A high percentage of patients benefited from the low vision rehabilitation. CONCLUSIONS: This study showed the high percentage of patients who benefit from low vision rehabilitation and confirmed the results achieved in other research studies. The conventional correction (standard glasses) was the most used optical aid for far distance sight. The microscope was the most representative optical aid for near sight in our study group


Subject(s)
Humans , Male , Female , Vision, Low/rehabilitation , Retinopathy of Prematurity/epidemiology , Retinopathy of Prematurity/rehabilitation , Epidemiology, Descriptive
3.
Cienc. tecnol. salud vis. ocul ; 7(2): 115-128, jul.-dic. 2009.
Article in Spanish | LILACS | ID: lil-560897

ABSTRACT

Según la OMS (1994), un paciente con baja visión es aquel que con su mejor corrección en el ojo con mayor visión tiene una agudeza visual no mejor a 20/60 y el campo visual es de 10º o menor. En la actualidad, hay más de doscientos millones de personas en el mundo con baja visión, por lo que es importante conocer y estudiar este campo, ya que hay muchas personas que necesitan la colaboración del profesional de la salud para mejorar su calidad de vida. El propósito de este artículo de revisión es dara conocer las generalidades de la baja visión, el diagnóstico, la conducta y, principalmente, presentar las diferentes ayudas ópticas, no ópticas y electrónicas para cubrir las necesidades del paciente según sus expectativas y motivación.


According to the World Health Organization (OMS,1994), a patient with low vision is one that with his best correction in the eye with greater visual acuity of vision has not improved to 20/60 and the visual field is 10 degrees or less. At this moment, there are over 200 million people in the world with low vision,That is why it is important to know and study this field, because there are many people who need the cooperation of health care practitioners to improve their quality of life. The purpose of this review article is to raise awareness about the generalities of low vision, diagnosis, behavior mainly given by the various optical, non optical and electronic aids, in order to supply the needs of the patient according to their expectations and motivation.


Subject(s)
Humans , Behavior , Diagnosis , Vision, Low
4.
Journal of the Korean Ophthalmological Society ; : 1960-1967, 2000.
Article in Korean | WPRIM | ID: wpr-172942

ABSTRACT

Ideal low vision devices used for reading should have a large clear field of view.To determine the usefulness of Aspheric Doublet Lens, we compared visual field, image clarity and reading speed of aids in 100 patients who were prescribed with Aspheric doublet lens, Telemicroscope with plus cap and Hand held magnifier.Aspheric doublet lens was prescribed most commonly.Used lens of optical aids was aspheric doublet lens, aplantic lens, biconvex lens and aspheric lens.Visual field and image clarity of Aspheric doublet lens were wider and clearer than those of other devices.Reading speed of each aid after prescription was improved significantly than before prescription (P=0.01).Reading speed of Aspheric doublet lens was more improved than that of other devices.Therefore Aspheric doublet lens might be useful as reading aids to low vision patients.


Subject(s)
Humans , Hand , Prescriptions , Vision, Low , Visual Fields
SELECTION OF CITATIONS
SEARCH DETAIL