1.
Chinese Journal of Experimental Ophthalmology ; (12): 177-181, 2013.
Article in Chinese | WPRIM | ID: wpr-636013

ABSTRACT

Background Corneal parameters (such as curvature,thickness,etc) are essential to the diagnosis of corneal related diseases,contact lenses fitting and corneal refractive surgery.Objective The aim of this study was to assess the repeatability and accuracy of corneal parameters obtained by RTVue Fourier-domain optical coherence topography (FD-OCT).Methods In this prospective study,77 eyes of 43 subjects with the refraction from-1.25 D to-10.00 D and astigmatism <2 D were enrolled in keratorefractive surgery center,Eye Hospital of Wenzhou Medical College.The anterior and posterior corneal curvature in 3 mm central zone (Ranterior and Rposterior),the ratio of posterior and anterior curvature (Rposterior/Ranterior),corneal central thickness (CCT),total corneal power(Knet),the simulated corneal power (Sim K),the anterior and posterior corneal power (Kanterior,Kposterior)were measured by FD-OCT.Corneal power (Km) was obtained by Topolyzer topography based on Placido ring.Three consecutive scans were acquired in every tested eye.Repeatability of FD-OCT measurement was assessed using the coefficient of variation CV),Cronbach Alpha and intra-class correlation coefficient (ICC).Repeated measure ANOVA was used to analyze the differences among SimK,Knet and Km.Pearson correlation analysis was used to analysis the correlation between SimK and K Knet and Km,SimK and Km.The agreement between Sim K and K Knet and Km,SimK and Km was assessed by Bland-Altman plots analysis.All the subjects understood the purpose of this investigation and written informed consent was obtained prior to the medical examination.Results The Ranterior,Rposterior,Rposterior/Ranterior,Kanterior,Kposterior,Sim K,Knet and CCT were (7.691 ±0.302) mm,(6.532±0.276) mm,0.849±0.014,(48.97±1.92)D,(-6.13±0.26)D,(43.95±1.72) D,(42.95±1.68) D and (545.20± 35.04) μm,respectively.The CV of all parameters was less than 1%.The Cronbach Alpha and ICC were both more than 0.9 except 0.802(ICC)of the Rposterior/Ranterior.SimK was (0.27±0.34) D higher than Km,and Knet was (0.73±0.37) D lower than Km.SimK was (1.01 ±0.11) D higher than K and all the differences showed a statistical significance (P<0.001).There were close positive correlations between SimK and Km,Knet and Km,SimK and Knet(all r ≥ 0.976,P<0.001).The Bland-Altman analysis showed a poor agreement between SimK and Km,Knet and Km,SimK and Knet.Conclusions The RTVue FD-OCT measuring corneal curvature and CCT performes good repeatability.The Sim K obtained by RTVue FD-OCT is slightly greater than that obtained by corneal topography,and the Rposterior/Ranterior obtained by RTVue FD-OCT is slightly lower than that from Gullstrand model eye.These results offer a basis for establishing a more accurate standardized model eye.

2.
Indian J Ophthalmol ; 2011 Jan; 59(1): 23-27
Article in English | IMSEAR | ID: sea-136133

ABSTRACT

Purpose: The aim was to study optic nerve head (ONH) parameters in normal Indian eyes using spectral domain optical coherence tomography (OCT)/scanning laser ophthamoscope (SLO). Materials and Methods: One hundred and fifty-seven eyes of 157 normal subjects of various age groups underwent ONH imaging with spectral OCT/SLO and the parameters obtained were correlated with disc size. The effect of age, gender, and refractive error on various ONH parameters were also studied. Results: The mean optic disc area was 3.36 ± 0.64 mm2 (range, 2.13–5.08 mm2), mean rim area was 2.49 ± 0.58 mm2 (range, 1.20–3.62 mm2), and mean cup area was 1.10 ± 0.75 mm2 (range, 0–3.07 mm2). The disc area showed significant positive correlation with the rim area, cup area, horizontal cup disc ratio, vertical cup disc ratio, cup disc area ratio, mean cup depth, and maximum cup depth (P < 0.001). Neither gender nor refractive error showed any significant difference in various ONH parameters. ONH parameters did not show significant change with age except for rim area which declined with the advancing age (r = –0.25, P < 0.001). Conclusions: The quantitative measurement of ONH topography obtained with this study provides a normative database for an Indian population with spectral OCT/SLO. As optic disc area influences ONH topography, disc size should to be considered when evaluating optic disc for progressive optic neuropathies such as glaucoma.

SELECTION OF CITATIONS
SEARCH DETAIL