1.
Chinese Journal of Experimental Ophthalmology ; (12): 47-52, 2017.
Article in Chinese | WPRIM | ID: wpr-638258

ABSTRACT

Background Optic neuritis is one of the common clinical neuro-ophthalmic diseases.Spectraldomain OCT (SD-OCT) is a valuable tool in assessing the thickness changes of retina,while enhanced depth imaging (EDI) OCT can further quantitatively and morphologically evaluate the changes of retina and choroid.The pathological mechanism of optic neuritis is unclear now.Objective This study was to quantitatively measure the retinal and choroidal thickness in early optic neuritis eyes by SD-OCT and EDI OCT.Methods A prospective cohort study was carried out in Tianjin Eye Hospital from July 2015 to May 2016.Twenty eyes of 20 patients with acute optic neuritis were enrolled as optic neuritis group and 22 eyes of 20 healthy subjects with matched age and gender were included in the normal control group.The mean thickness of retinal nerve fiber layer (RNFL) and choriod in superior,inferior,nasal and temporal quadrants at 3.4 mm around optic disc was measured,and the mean thickness of RNFL,ganglion cell layer (GCL),inner plexiform layer (IPL),inner nuclear layer (INL),outer plexiform layer (OPL),outer nuclear layer (ONL) and photoreceptor layer also was measured by EDI OCT.Pattern visual evoked potential (P-VEP) and visual field were examined in all the individuals,the correlations of mean defect (MD) with the thickness of RNFL,choroid and the thickness of RNFL,GCL,IPL,INL,OPL,ONL,photoreceptor layer at macular area were evaluated.Results The RNFL thickness values were (424.00±160.30),(428.40±169.83) and (108.15 ±50.66) μm in superior,inferior,nasal quadrants at 3.4 mm arear around optic disc in the optic neuritis group,which were significantly higher than (265.68±26.25),(283.27±52.81) and (72.68± 12.01) μm in the normal control group (t=4.571,3.814,3.190,all at P<0.01),and there was no significant difference between the two groups (t =0.849,P =0.401),and no significant differences were found in choroidal thickness of 4 quadrants between the two groups (all at P>0.05).The thickness of RNFL,GCL and IPL at 1 mm area around macula and the thickness of GCL,IPL,INL at 3 mm area around macula were evidently thining in the optic neuritis group compared with the normal control group (all at P<0.05).The latency of P100 wave was (133.15±11.11) seconds in the optic neuritis group and that in the control group was (94.59 ±4.38) seconds,showing a significnat difference between them (t =15.058,P<0.05).Positive correlations were found between MD and the RNFL thickess in superior,inferior,nasal quadrants at 3.4 mm arear around optic disc (r =0.649,0.649,0.635,all at P<0.05),however,no evidentlylinear correlations were found between MD and choroidal thickness in 4 quadrands (r =-0.120,-0.102,-0.415,0.120,all at P>0.05),and the thickness of RNFL,GCL,IPL,INL,OPL,ONL,photoreceptor layer at macular area was significantly linear correlated with MD.Conclusions EDI OCT can reflect the RNFL edema around optic disc and thining of various layers of retina at macular area in acuter optic neuritis eyes,however,the choroidal thickess is unchanged.EDI OCT is a useful tool in quantitative evaluation of retinal and choroidal thickness of early optic neuritis.

2.
Chinese Journal of Experimental Ophthalmology ; (12): 249-253, 2011.
Article in Chinese | WPRIM | ID: wpr-635304

ABSTRACT

Background Many studies showed that attenuation of retinal nerve fiber layer(RNFL)in early glaucoma is one of the important signs.How to accurately and quantitatively measure RNFL thickness is very important for the early diagnosis and monitoring of glaucoma.0bjective This study was to evaluate the clinical value of Optovue RTVue OCT and Heidelberg Retina Tomograph Ⅲ(HRT-Ⅲ)confocal scanning laser ophthalmoscopy in glaucomatous eyes. Methods This cross-sectional study included 40 eyes of 26 patients with suspected open-angle glaucoma(SOAG),48 eyes of 29 patients with open-angle glaucoma and 48 eyes of 27 healthy subjects.Optical nerve head(ONH) parameters and peripapillary RNFL thickness were measured in all the subjects with Optovue RTVue OCT and HRT-Ⅲ,meanwhile all the eyes received perimetry with Humphrey 750-I.Glaucoma variables obtained from Optovue RTVue OCT and HRT-Ⅲ were analyzed among the groups.Topographic Optovue RTVue OCT and HRT-Ⅲ parameters,including disc area(DA),cup area(CA),rim area(RA),rim volume(RV),cup volume(CV),cup/disc area ratio(C/DAR)as well as superior,temporal,inferior and nasal average RNFL thickness,were analyzed.The relationship of ONH parameters and RNFL thickness was analyzed using a linear correlation.The correlation between the mean defect(MD)of the visual field and the tomography parameters in glaucomatous eyes was described by bivariate Pearson correlation coefficients.Resuits The ONH parameters and RNFL thickness obtained by HRT-Ⅲ and OCT showed significant difference(P<0.05).ONH parameters such as RA,C/DAR,CA and RV were statistically changed in SOAG and the POAG patients compared with the normal subjects(q=6.47,q=7.67,P<0.05).The superior and inferior RNFL thickness parameters in three groups were positively correlated between HRT-Ⅲand OCT(r=0.362,r=0.441,r=0.395,P<0.05),Topographic Optovue RTVue OCT and HRT-Ⅲ parameters including CV,CA,RA and C/DAR fitted Pearson analysis(all P<0.05).In POAG group。The RA,RV,CV,C/DAR from Optovue RTVue OCT were correlated with MD with the significant coefficient 0.284,0.286,0.340,0.371 respectively(P<0.05),and evidently correlations also were found between RA,RV,C/DAR with MD respectively with the coefficient 0.339,0.859,0.422(P<0.05)by HRT-Ⅲ. Conclusion Both Optovue RTVue OCT and HRT-Ⅲ can difierentiate ONH analysis with a similar outcome in glaucomatous eye.The C/D value.RA,superior and inferior RNFL thickness based on Optovue RTVue OCT and HRT-Ⅲare distinguishing indexes in the diagnosis of early glaucomatous damage.

SELECTION OF CITATIONS
SEARCH DETAIL