Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Language
Year range
1.
China Pharmacy ; (12): 4298-4301, 2017.
Article in Chinese | WPRIM | ID: wpr-704433

ABSTRACT

OBJECTIVE:To evaluate the dissolution curves similarity of generic and original preparation of Losartan potassium tablets,and to provide reference for improving quality evaluation of the preparation.METHODS:Using hydrochloric acid solution (pH 3.0),phosphate buffer solution(pH 4.5),phosphate buffer solution (pH 6.8) and water as medium,paddle method was adopted for dissolution test with dissolution medium volume of 900 mL and rotation speed of 50 r/min.UV-visible spectrophotometry was adopted to determine accumulative dissolution of generic and original preparation of Losartan potassium tablets with the detection wavelength of 256 um.The similarity of dissolution curves were evaluated by calculating similarity factor(f2).RESULTS:The linear range of losartan potassium was 12.11-35.96 μg/mL (r≥0.999 7).RSDs of precision,stability and reproducibility tests were all lower than 5.0%.The recoveries of 4 dissolution media were 98.66%-100.84% (RSD=0.77%,n=9),98.91%-100.59% (RSD=0.49%,n=9),98.33%-101.39% (RSD=0.85%,n=9),99.46%-101.32% (RSD=0.55%,n=9).In 4 dissolution media,f2 of the dissolution curves of 3 batches of generic and original preparation of Losartan potassium tablets were all higher than 70.CONCLUSIONS:The dissolution curves of self-made and original preparation of Losartan potassium tablets show good similarity.

2.
China Pharmacy ; (12): 3393-3396, 2016.
Article in Chinese | WPRIM | ID: wpr-504935

ABSTRACT

OBJECTIVE:To systematically review the efficacy and safety of the generic and original preparation of atorvas-tatin,and provide evidence-based reference for clinical treatment. METHODS:Retrieved from PubMed,EMBase,Cochrane Li-brary,CJFD,Wanfang Database,VIP and CBM,related randomized controlled trials(RCT)about generic preparation of atorvas-tatin(test group)versus original preparation of atorvastatin(control group)were collected. Meta-analysis was performed by using Rev Man 5.3 software after data extract and quality evaluation. RESULTS:Totally 16 RCTs were included,involving 2 077 pa-tients. Results of Meta-analysis showed,compared with control group,there were no significant differences in reducing total choles-terol (TC) [MD=-0.06,95%CI(-0.14,0.01),P=0.11],triglyceride (TG) [MD=-0.00,95%CI(-0.08,0.08),P=0.99], low-density lipoprotein cholesterol (LDL-C) [MD=-0.07,95%CI(-0.16,0.01),P=0.09],increasing high-density lipoprotein cholesterol(HDL-C)[MD=-0.00,95% CI(-0.03,0.03),P=0.96] and the incidence of major adverse cardiac events(MACE) [OR=1.18,95%CI(0.71,1.97),P=0.52] in test group;in terms of safety,compared with control group,there were no significant differences in the resulting in alanine aminotransferase (ALT) increased [OR=1.08,95%CI(0.51,2.30),P=0.83],the incidences of myalgia [OR=2.46,95%CI(0.70,8.65),P=0.16] and gastrointestinal adverse reactions [OR=1.11,95%CI(0.64,1.95),P=0.71]. CONCLUSIONS:Both the generic and original preparation of atorvastatin can effectively reduce blood lipid levels,with sim-ilar safety.

3.
China Pharmacy ; (12): 4278-4281, 2016.
Article in Chinese | WPRIM | ID: wpr-503388

ABSTRACT

OBJECTIVE:To establish a method for the dissolution determination of Dronedarone hydrochloride tablet,and eval-uate the quality consistency of its generic and original preparations. METHODS:UV spectrometry was performed on the column of 288 nm,dissolution media of Phosphate buffer solution (pH4.5),0.1 mol/L Hydrochloric acid solution [adding into 0.5% sodium dodecyl sulfate(SDS)],Phosphate buffer solution [pH6.8,adding into 0.5%SDS] and water,volume of dissolution medium was 1 000 ml,rotation speed was 75 r/min,the dissolution of generic and original preparations of Dronedarone hydrochloride tablet was detected,and the similarity of dissolution curve was evaluated by calculating the similarity factor (f2). RESULTS:The linear range of dronedarone hydrochloride was 2.147-25.764 μg/ml;RSDs of precision,stability and reproducibility tests were lower than 2.0%;recoveries 4 dissolution media were 99.53%-101.05%(RSD=0.48%,n=9),98.95%-100.05%(RSD=0.39%,n=9), 99.54%-100.20%(RSD=0.24%,n=9)and 98.54%-100.06%(RSD=0.44%,n=9). In the 4 dissolution media,f2 of the dissolu-tion curve of 3 batches of generic and original preparations of Dronedarone hydrochloride tablet was 56,60,63,68,68,52,59, 67,65,68,76,62,respectively. CONCLUSIONS:The method is suitable for the dissolution determination of Dronedarone hydro-chloride tablet;meanwhile,the in vitro dissolution curves of generic and original preparations of Dronedarone hydrochloride tablet show similarity,so the quality consistency is good.

4.
China Pharmacy ; (12): 4307-4310, 2016.
Article in Chinese | WPRIM | ID: wpr-503381

ABSTRACT

OBJECTIVE:To evaluate the similarity of in vitro dissolution of self-made and original preparation of Ramelteon tablet. METHODS:The paddle method was adopted with rotational speed of 50 r/min,using water,pH1.2 hydrochloric acid solu-tion,pH4.0 acetate buffer solution and pH6.8 phosphate buffer solution as dissolution media,HPLC was used to determine the cu-mulative dissolution of main components of self-made and original preparation of Ramelteon tablet at different time points,dissolu-tion profile was drew,then f2 was used to evaluate its similarity. RESULTS:In the 4 dissolution media,the f2 of self-made and original preparation of Ramelteon tablet was 62.8,80.0,77.7,76.2,respectively,which indicated that the dissolution profiles showed similarity. CONCLUSIONS:The established HPLC is suitable for the dissolution determination of Ramelteon tablet;the dissolution profiles of the self-made and original preparations are similar,it preliminary indicates the prescription and technological rationality of self-made preparation.

5.
China Pharmacy ; (12): 4311-4314, 2016.
Article in Chinese | WPRIM | ID: wpr-503380

ABSTRACT

OBJECTIVE:To explore the similarity of dissolution profiles of self-development and original preparation of Solife-nacin succinate tablet,and provide reference for the prescription and process screening of the former one and the quality similarity evaluation of the latter one. METHODS:The paddle method was adopted with rotational speed of 50 r/min,using water,pH1.2 hy-drochloric acid solution,pH4.0 acetate buffer solution and pH6.8 phosphate buffer solution as dissolution media,HPLC was used to determine the cumulative dissolution of main components of self-development and original preparation of Solifenacin succinate tablet at different time points,dissolution profile was drew,then f2 was used to evaluate its similarity. RESULTS:In the 4 dissolu-tion media,the f2 of both self-development and original preparation of Solifenacin succinate tablet was higher than 50,which indi-cated that the dissolution profiles showed similarity. CONCLUSIONS:The established HPLC is suitable for the dissolution determi-nation of Solifenacin succinate tablet;the dissolution profiles of the self-development and original preparations are basically simi-lar,which indicates the prescription and technology of self-development preparation are feasible.

6.
China Pharmacy ; (12): 4291-4294, 2015.
Article in Chinese | WPRIM | ID: wpr-501132

ABSTRACT

OBJECTIVE:To establish a method for the dissolubility determination of Manidipine Hydrochloride tablet and eval-uate the quality consistency of generic and original preparation. METHODS:HPLC was performed on the column of Waters Sym-metry C18 column with mobile phase of potassium phosphate monobasic solution (potassium phosphate monobasic 6.8 g was well-mixed with water 1 000 ml,and pH was adjusted to 4.6 by potassium hydroxide solution)-acetonitrile (49∶51,V/V) at flow rate of 1.0 ml/min,detection wavelength was 228 nm,column temperature was 25℃,and the injection volume was 20μl. The dis-solution mediums were 0.1 mol/L hydrochloric acid solution,acetic acid-sodium acetate buffer solution(pH 4.0)and phosphate buf-fer solution [pH 6.8,adding into 0.5% sodium dodecyl sulfonate(SDS)],volume of dissolution medium was 900 ml and rotating rate was 50 r/min,and the dissolubility of Manidipine hydrochloride tablet generic and original preparation was investigated and the similarity of dissolution profile was evaluated by calculating similar factor (f2). RESULTS:The linear range of manidipine hydro-chloride was 0.625-20 μg/ml;RSDs of instrument precision and stability tests were lower than 2.0%;recoveries of 3 dissolution mediums were 92.86%-102.97%(RSD=1.9%,1.8% and 2.7%,n=9),respectively. The dissolubility of 3 batches of Manidipine hydrochloride tablet generic and original preparations was higher than 85% in 0.1 mol/L hydrochloric acid solution in 15 min;f2 was >50 in acetic acid-sodium acetate buffer solution (pH 4.0) and phosphate buffer solution (pH 6.8,adding into 0.5% SDS). CONCLUSIONS:The method is suitable for the dissolubility determination of Manidipine hydrochloride tablet;meanwhile,the dis-solution profile in vitro of Manidipine hydrochloride tablet generic and original preparations has similarities,so the quality consis-tency is good.

SELECTION OF CITATIONS
SEARCH DETAIL