ABSTRACT
Objective: To assess patient?s level of oxygenation by means of pulse oximetry, avoiding hypoxia (that causes rapid and severe damage), hyperoxia, and waste. Methods: Calculations were made with a 7% margin of error and a 95% confidence interval. Physical therapists were instructed to check pulse oximetry of all patients with prescriptions for physical therapy, observing the scheduled number of procedures. Results: A total of 129 patients were evaluated. Hyperoxia predominated in the sectors in which the patient was constantly monitored and hypoxia in the sectors in which monitoring was not continuous. Conclusions: Professionals involved in patient care must be made aware of the importance of adjusting oxygen use and the risk that non-adjustment represents in terms of quality of care and patient safety.
Objetivo: Avaliar a oxigenação dos pacientes por meio da oximetria de pulso, evitando a hipóxia (cujo dano é rápido e grave) e a hiperóxia, evitando o desperdício. Métodos: Foi realizado um cálculo de amostra com margem de erro em 7% e intervalo de confiança de 95%. Os fisioterapeutas foram orientados a checar a oximetria de pulso de todos os pacientes com prescrição de fisioterapia, respeitando o número de atendimentos programados. Resultados: Foram avaliados 129 pacientes. A hiperóxia predominou nos setores que o paciente permaneceu monitorado e a hipóxia nos setores em que a monitorização não era contínua. Conclusões: Faz-se necessária a conscientização dos profissionais envolvidos na assistência ao paciente sobre a importância da adequação do oxigênio e o risco que sua inadequação representa na qualidade do atendimento e na segurança do paciente.