Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Arq. Inst. Biol ; 87: e0802018, 2020. tab
Article in English | LILACS, VETINDEX | ID: biblio-1118053

ABSTRACT

This research evaluated the effect of milking on the physical exam of the mammary gland (MG) and milk examination in Saanen goats. Six properties were selected, four farms were used after evaluation of criteria selection and distributed in two groups according to the milking method: manual or mechanical. The physical examination of MG was performed using the techniques of inspection and palpation, in addition to the examination of the milk by strip cup, California Mastitis Test, somatic cell count, and bacteriological exam. It was possible to detect an association between the milking method with the most of physical exam of the MG: inspection of the MG (p = 0.001), inspection of the teat (p = 0.002), palpation of the MG (p = 0.054) and palpation of the teat (p = 0.036). The machine milking had an association with the reduction of the volume of MG (OR = 6.00), reduction of the teat size (OR = 16.19), and firm consistency of mammary parenchyma (OR = 2.39). The use of machine milking represented a less risk for an increase of the volume of the MG volume (OR = 0.288) and the presence of cisternitis (OR = 0.490). The association between the SCC and the type of milking was also detected (p = 0.002). Machine milking was associated with changesin the physical exam of MG and milk examination compatible with traumatic lesions. This information indicates inappropriate use of milking equipment in the dairy goat's properties.(AU)


Esta pesquisa avaliou o efeito da ordenha sobre o exame físico da glândula mamária (GM) e do leite em cabras Saanen. Seis propriedades foram selecionadas, quatro fazendas foram utilizadas após avaliação da seleção dos critérios e distribuídas em dois grupos de acordo com o método de ordenha: manual ou mecânico. O exame físico da GM foi realizado utilizando as técnicas de inspeção e palpação, além do exame do leite pelo teste da caneca de fundo escuro, California Mastitis Test, contagem de células somáticas e exame bacteriológico. Foi possível detectar uma associação entre o método de ordenha com a maioria dos exames físicos da GM: inspeção da GM (p = 0,001), inspeção do teto (p = 0,002), palpação da GM (p = 0,054) e palpação do teto (p = 0,036). A ordenha mecânica associou-se com a redução do volume de GM (OR = 6,00), redução do tamanho do teto (OR = 16,19) e consistência firme do parênquima mamário (OR = 2,39). O uso da ordenha mecânica representou menor risco para o aumento do volume do volume da GM (OR = 0,288) e presença da cisternite (OR = 0,490). Também foi detectada a associação entre a CCS e o tipo de ordenha (p = 0,002). A ordenha mecânica foi associada com as alterações no exame físico de GM e do leite compatíveis com lesões traumáticas. Essas informações indicam o uso inadequado do equipamento de ordenha na criação de cabras leiteiras.(AU)


Subject(s)
Cattle , Palpation , Mammary Glands, Animal , Physical Examination/veterinary , Cell Count/methods , Milk , Encephalitis, California/diagnosis
2.
Rev. bras. cineantropom. desempenho hum ; 20(6): 515-524, Nov.-Dec. 2018. tab, graf
Article in English | LILACS | ID: biblio-990553

ABSTRACT

Abstract The postural evaluation software (SAPO) has been used as a valuable tool for the analysis of postural alterations, however, such a tool depends on palpation performed by the evaluator. The aim of the present study was to evaluate the inter-and intra-examiner reliability of experienced and inexperienced examiners in measurements derived from the palpation method, and its possible influence on measurements obtained by SAPO. Nine evaluators participated in the study, which were divided into three groups according to experience with respect to palpation (GI: inexperienced group, GSE: semi-experienced group and GE: experienced group). Each evaluator performed the postural analysis of 10 volunteers, which were photographed in orthostatic position, following the SAPO recommendations. The intra-examiner reliability analysis indicated that all three groups had higher, good and moderate mean correlation values for each examiner than low correlations. In the inter-examiner reliability assessment, GE and GSE groups exhibited higher correlation values. The intra-class correlation coefficient, in the single-measure analysis, presented correlation coefficients <0.70 in 9 of the variables analyzed, indicating non-significant correlation. It was concluded that the measures analyzed by SAPO have high intra-examiner reliability. However, regarding inter-examiner reliability, the group composed of inexperienced evaluators presented lower values, suggesting that the experience time may have influenced the inter-examiner reliability regarding postural evaluation.


Resumo O Software de avaliação postural (SAPO) vem sendo utilizado como uma ferramenta valiosa para a análise das alterações posturais, porém tal ferramenta depende da palpação realizada pelo examinador. O objetivo do presente estudo foi avaliar a fidedignidade inter e intraexaminadores experientes e inexperientes nas medidas derivadas do método de palpação, e sua possível influência sobre as medidas obtidas pelo SAPO. Participaram do estudo nove avaliadores, divididos em três grupos de acordo com a experiência com relação a palpação (GI: grupo inexperiente, GSE: grupo semi experiente e GE: grupo experiente). Cada avaliador realizou a análise postural de 10 voluntários, os quais foram fotografados em posição ortostática, seguindo as recomendações do SAPO. A análise da fidedignidade intraexaminadores indicou que os três grupos apresentaram valores de correlação em média mais altos, bons e moderados, do que correlações baixas. Na avaliação da fidedignidade interexaminadores os grupos GE e GSE exibiram valores de correlação mais altos. O coeficiente de correlação intraclasse, na análise de medida única, apresentou índices de correlação <0,70 em 9 das variáveis analisadas, indicando correlação não considerável. Concluiu-se que as medidas analisadas pelo SAPO possuem uma alta fidedignidade intraexaminadores. No entanto, em relação a fidedignidade interexaminadores o grupo composto por examinadores inexperientes com relação a palpação apresentou valores mais baixos, sugerindo que o tempo de experiência dos examinadores pode ter influenciado na fidedignidade interexaminadores da avaliação postural.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Palpation , Posture , Software , Photogrammetry
3.
RBM rev. bras. med ; 70(6)jun. 2013.
Article in Portuguese | LILACS | ID: lil-683419

ABSTRACT

O assoalho pélvico é formado por um grupo de músculos e ligamentos que têm a função básica de sustentar os órgãos pélvicos e abdominais. O objetivo da pesquisa foi verificar e discutir os métodos de avaliação do assoalho pélvico existentes na literatura nos últimos 20 anos. A pesquisa se deu a partir de uma revisão bibliográfica da literatura nas bases de dados SciELO, Medline, Lilacs, Pubmed e em livros de Uroginecologia entre setembro e novembro de 2011. Várias são as maneiras de avaliar a função dos músculos do assoalho pélvico e, nos últimos 20 anos, as técnicas foram aperfeiçoadas para um melhor conforto, tanto do paciente como do terapeuta. Palpação bidigital, cones vaginais, perineometria, eletromiografia são técnicas importantes, por promoverem feedback sensorial ao paciente. Ultrassom e ressonância magnética também são métodos louváveis por avaliar dinamicamente o assoalho pélvico, porém são utilizados experimentalmente, pelo grande dispêndio de dinheiro...


Subject(s)
Pelvic Floor , Magnetic Resonance Spectroscopy
4.
Rev. bras. anestesiol ; 63(3): 245-248, maio-jun. 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-675839

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: A palpação foi demonstrada não ser muito precisa para identificar espaços interespinhosos lombares em anestesia neuroaxial. O objetivo deste estudo foi avaliar a precisão para determinar os espaços interespinhosos lombares pela palpação por anestesiologistas com o uso de radiografias pós-operatórias em pacientes obstétricas. MÉTODOS: Revisamos os registros anestésicos e as radiografias abdominais pós-operatórias de cesarianas. Inserimos o cateter epidural para analgesia pós-operatória com dose única. Incluímos casos de anestesia combinada raqui-peridural e comparamos o nível interespinhoso registrado pelo anestesiologista e o nível de inserção do cateter peridural confirmado pela radiografia abdominal de cada caso. Também avaliamos os fatores (idade, peso, altura, Índice de Massa Corporal, idade gestacional e tipo de cirurgia [programada/emergência]) que levaram à identificação errônea do nível interespinhoso. RESULTADOS: Foram avaliadas 835 cesarianas de 967 feitas. Os níveis das punções documentados pelos anestesiologistas estavam de acordo com os níveis reais de inserção dos cateteres em 563 casos (67%). Quando os anestesiologistas objetivaram identificar o nível L2-3, descobrimos que a inserção do cateter foi em L1-2 em cinco casos (4,9%), dos quais nenhum apresentou qualquer déficit neurológico pós-operatório. Nenhuma das variáveis avaliadas estava significativamente associada à identificação errônea do nível interespinhoso pelos anestesiologistas. CONCLUSÃO: Houve uma discrepância entre o nível estimado pela palpação dos anestesiologistas e o nível real de inserção do cateter mostrado nas radiografias. Parece ser mais seguro escolher o nível interespinhoso L3-4, ou mais baixo, em raquianestesia.


BACKGROUND AND OBJECTIVES: Palpation has been shown to be rather inaccurate at identifying lumbar interspinous spaces in neuraxial anesthesia. The aim of this study is to assess the accuracy of the determination of the lumbar interspinous spaces by anesthesiologist's palpation using post-operative X-rays in obstetric patients. METHODS: We reviewed the anesthetic record and the post-operative abdominal X-rays of the cesarean sections. We indwelled the epidural catheter for post-operative one-shot analgesia. We included combined spinal and epidural anesthesia cases and compared the interspinous level which the anesthesiologist recorded and the epidural catheter insertion level confirmed by abdominal X-ray for each case. We also evaluated the factors (age, body weight, height, Body Mass Index, gestational age, and the type of surgery [planned / emergency]) leading to misidentification of interspinous level. RESULTS: Nine hundred and sixty seven cesarean sections were performed and a total of 835 cases were evaluated. The levels of the puncture documented by the anesthesiologists were in agreement with the actual catheter insertion levels in 563 (67%) cases. When the anesthesiologists aimed at L2-3 level, we found the catheter insertion at L1-2 in 5 cases (4.9%), none of which had any post-operative neurological deficits. No variables evaluated were significantly associated with misidentification of interspinous level by the anesthesiologists. CONCLUSIONS: There was a discrepancy between the anesthesiologists' estimation by palpation and the actual catheter insertion level shown in X-rays. It seems to be safer to choose the interspinous level L3-4 or lower in spinal anesthesia.


JUSTIFICATIVA Y OBJETIVOS: Está comprobado que la palpación no es muy exacta para identificar los espacios interespinosos lumbares en la anestesia neuroaxial. El objetivo de este estudio, fue evaluar la precisión para determinar los espacios interespinosos lumbares a través de la palpación por anestesiólogos con el uso de radiografías postoperatorias de pacientes obstétricas. MÉTODOS: Revisamos los registros anestésicos y las radiografías abdominales postoperatorias de cesáreas. Insertamos el catéter epidural para la analgesia postoperatoria con una dosis única. Incluimos casos de anestesia combinada raqui-epidural y comparamos el nivel interespinoso registrado por el anestesiólogo y el nivel de inserción del catéter epidural confirmado por la radiografía abdominal de cada caso. También evaluamos los factores (edad, peso, altura, Índice de Masa Corporal, edad gestacional y tipo de cirugía [programada/emergencia]), que que levaram à identifi cação errônea do nível interespinhoso. RESULTADOS: Se evaluaron 835 cesáreas de las 967 que se hicieron. Los niveles de las punciones documentados por los anestesiólogos estaban a tono con los niveles reales de inserción de los catéteres en 563 casos (67%). Cuando los anestesiólogos quisieron identificar el nivel L2-3, descubrimos que la inserción del catéter fue en L1-2 en cinco casos (4,9%), de los cuales ninguno tuvo ningún déficit neurológico postoperatorio. Ninguna de las variables evaluadas estaba significativamente asociada con la identificación equivocada del nivel interespinoso por los anestesiólogos. CONCLUSIONES: Hubo una discrepancia entre el nivel estimado por la palpación de los anestesiólogos y el nivel real de inserción del catéter mostrado en las radiografías. Parece ser más seguro escoger el nivel interespinoso L3-4, o más bajo, en raquianestesia.


Subject(s)
Adult , Female , Humans , Middle Aged , Pregnancy , Young Adult , Anesthesia, Obstetrical , Cesarean Section , Lumbar Vertebrae/anatomy & histology , Lumbar Vertebrae , Palpation , Reproducibility of Results , Retrospective Studies
5.
Rev. bras. ginecol. obstet ; 35(5): 221-225, May 2013. tab
Article in English | LILACS | ID: lil-679404

ABSTRACT

PURPOSE: We aimed to determine whether clinical examination could adequately ascertain the volume of tissue to be resected during breast-conserving surgery after neoadjuvant therapy. METHODS: We reviewed the clinical reports of 279 patients with histologically diagnosed invasive breast carcinomas treated with neoadjuvant therapy followed by surgery or with primary surgery alone. We estimated volumes of excised tissues, the volume of the tumor mass and the optimal volume required for excision based on 1 cm of clear margins. The actual excess of resected volume was estimated by calculating the resection ratio measured as the volume of the resected specimen divided by the optimal specimen volume. The study endpoints were to analyze the extent of tissue resection and to ascertain the effect of excess resected tissue on surgical margins in both groups of patients. RESULTS: The median tumor diameter was 2.0 and 1.5 cm in the surgery and neoadjuvant therapy groups, respectively. The median volume of resected mammary tissue was 64.3 cm³ in the primary surgery group and 90.7 cm³ in the neoadjuvant therapy group. The median resection ratios in the primary surgery and neoadjuvant therapy groups were 2.0 and 3.3, respectively (p<0.0001). Surgical margin data were similar in both groups. Comparison of the volume of resected mammary tissues with the tumor diameters showed a positive correlation in the primary surgery group and no correlation in the neoadjuvant therapy group. CONCLUSION: Surgeons tend to excise large volumes of tissue during breast-conserving surgery after neoadjuvant therapy, thereby resulting in a loss of the correlation between tumor diameter and volume of the excised specimen.


OBJETIVO: Foi determinar se a avaliação clínica é adequada na determinação do volume a ser ressecado em cirurgias conservadoras de mama após tratamento neoadjuvante. MÉTODOS: Avaliamos 279 pacientes com diagnóstico histológico de carcinoma invasor de mama submetidas à terapia neoadjuvante seguida de tratamento cirúrgico ou tratadas com cirurgia primária. O volume de tecido excisado, o volume da massa tumoral e o volume ótimo para a excissão cirúrgica baseado em uma margem de 1 cm foram calculados. O excesso de volume excisado foi estimado pelo cálculo da taxa de ressecção determinada pelo volume de tecido excisado dividido pelo volume ótimo para a excisão cirúrgica. Analisamos a extensão da ressecção cirúrgica e o efeito do exesso de tecido ressecado na obtenção de margens cirúrgicas. RESULTADOS: A mediana do diâmetro tumoral foi de 2,0 e 1,5 cm nos grupos de cirurgia primária e terapia neoadjuvante, respectivamente. A mediana do volume de tecido mamário ressecado foi de 64,3 cm³ no grupo de cirurgia primária e de 90,7 cm³ no grupo de tratamento neoadjuvante. A taxa mediana de ressecção nos grupos de cirurgia primária e terapia neoadjuvante foram 2,0 e 3,3 respectivamente (p<0,0001). Os dados relacionados à margem cirúrgica foram similares em ambos os grupos. A comparação do volume de tecido ressecado mostrou correlação positiva no grupo de cirurgia primária, porém não no grupo de tratamento neoadjuvante. CONCLUSÃO: Existe uma tendência dos cirurgiões a removerem maior quantidade de tecido mamário durante cirurgias conservadoras de mama de pacientes que foram submetidas à tratamento neoadjuvante, resultando na perda da correlação entre o diâmetro tumoral e o volume do espécime excisado.


Subject(s)
Female , Humans , Middle Aged , Breast Neoplasms/pathology , Breast Neoplasms/surgery , Mastectomy, Segmental/methods , Breast Neoplasms/therapy , Neoadjuvant Therapy , Retrospective Studies
6.
Article in Portuguese | LILACS | ID: lil-549671

ABSTRACT

A freqüência cardíaca (FC) durante o exercício tem sido utilizada no controle da intensidade de exercícios aeróbios. A palpação é o método mais popular e acessível para este fim. As respostas obtidas em testes laboratoriais são utilizadas para aplicações em campo, supondo-se que sejam semelhantes. O objetivo do estudo foi correlacionar as medidas de FC por palpação e por monitor de FC (MFC) em quatro sessões de exercício aeróbio e comparar os resultados obtidos entre sessões realizadas em laboratório e em campo. Participaram do estudo 15 mulheres jovens saudáveis que realizaram quatro sessões de exercício aeróbio, com carga contínua e duração de 40 minutos cada, sendo duas sessões em esteira e duas sessões em pista (50-60% e 80-85% FCmax). Durante as sessões, a FC foi registrada minuto a minuto pelo MFC (Polar Accurex) e medida a cada 10 minutos pela palpação do pulso radial. Foram observadas diferenças significativas entre a comparação das diferenças (deltas - ?) obtidas entre as medidas de FC pela palpação e pelo MFC, nas sessões de exercício na pista e no laboratório em apenas algumas situações. Foram observadascorrelações fortes (r = 0,95) e moderadas para forte (r = 0,73) entre palpação e MFC nas quatro sessões. A FC de esforço na palpação foi subestimada não mais do que 5%, mas não houve diferenças significativas entre os valores médios absolutos de FC mensuradas pelo MFC e pela palpação. Pode-se concluir que para uma mesma intensidade de esforço, os resultados obtidos no campo e laboratório foram semelhantes. Além disso, a FC pela palpação da artéria radial, imediatamente após o esforço, pode ser utilizada no controle de intensidade de exercícios aeróbios, representando uma monitorização fisiológica próxima da real obtida por MFC


Heart rate (HR) during exercise has been used for the control of aerobic exercise intensity. Palpation is the most popular and accessible method for this purpose. The responses obtained in laboratory tests are used for application and are suggested to be similar. The objective of this study was to correlate the HR measures obtained by palpation and with a heart rate monitor (HRM) in four sessions of aerobic exercise, and to compare the results obtained in the laboratory and in the . Fifteen healthy young women underwent four sessions of aerobic training of 40 min each at a continuous load, including two sessions on a treadmill and two in the (50-60% and 80-85% HRmax). During the sessions, HR was recorded minute-by-minute with an HRM (Polar Accurex) and measured at 10-minute intervals by pulse palpation. There were significant differences in ?HR values obtained by palpation and with the HRM between exercise sessions performed on the track and in the laboratory. Strong correlations (r = 0.95) and moderate to strong (r = 0.73) correlations were observed between palpation and HRM in the four sessions. HR during exercise obtained by palpation was underestimated by no more than 5%, but there were no significant differences in mean absolute HR measured by HRM and palpation. For the same exercise intensity, similar results are obtained in the and laboratory. In addition, HR obtained by palpation of the radial artery immediately after exercise can be used for the control of aerobic exercise intensity.

7.
Rev. HCPA & Fac. Med. Univ. Fed. Rio Gd. do Sul ; 30(2): 125-130, 2010. ilus, graf, tab
Article in Portuguese | LILACS | ID: biblio-834341

ABSTRACT

Introdução: Diversas técnicas foram propostas para avaliação da musculatura do assoalho pélvico, porém, nenhum método mostrou-se capaz de medir as duas funções desses músculos: elevação e força de compressão. Na rotina de avaliação clínica é comumente empregada a palpação vaginal e, especialmente, o escore de Oxford modificado; entretanto, alguns trabalhos questionam a sensibilidade da escala de Oxford e sua correlação com medidas objetivas de força de contração muscular. Objetivo: neste estudo, propõe-se correlacionar as variáveis medidas na perineometria com o escore de Oxford modificado. Métodos: foram incluídas no estudo 45 pacientes com incontinência urinária que procuraram o ambulatório de Uroginecologia do Hospital de Clínicas de Porto Alegre. As pacientes foram submetidas à palpação vaginal, realizada por uma fisioterapeuta treinada na escala de Oxford, e a medição da força de compressão da musculatura pélvica por meio de balonete conectado a transdutor de pressão. As duas avaliações foram realizadas no mesmo dia. Resultados: encontrou-se correlação significativa (P <0,001) entre o escore de Oxford e as variáveis pressão máxima de contração e tempo de ativação muscular com coeficientes de Pearson de 0,69 e -0,532, respectivamente. Contudo, observa-se uma superposição entre as medidas perineométricas e do escore de Oxford entre categorias adjacentes. Conclusões: Os resultados mostram que apesar de estar incorporada a rotina clínica de avaliação, deve haver restrições quanto ao uso do escala de Oxford com propósitos científicos.


Background: Several techniques have been proposed for the assessment of pelvic floor muscles; however, none of them were able to measure the two main functions of these muscles: lifting and compressive force. Vaginal palpation and especially the Modified Oxford Scale (MOS) are frequently used during routine clinical evaluation, but some studies have questioned the sensitivity of the MOS and its correlation with objective measurements of muscle contraction force. Aim: the objective of this study is to correlate perineometry measurements with the MOS.Methods: Forty-five patients with urinary incontinence treated at the Urogynecology Outpatient Clinic of Hospital de Clínicas de Porto Alegre were included. The patients were submitted to vaginal palpation performed by a physical therapist trained in the MOS. The compression force of their pelvic muscles was measured by means of an air-filled ballonet connected to a pressure transducer. Both tests were carried out on the same day. Results: we found significant correlation (P < 0.001) between the MOS and the variables maximum contraction pressure andmuscular activation time with Pearson's coefficients of 0.69 and -0.532, respectively. However, we found overlapping results between the perineomtry measurements and the MOS scores in neighboring categories. Conclusions: these findings show that, although incorporated into routine clinical evaluation, there should be restrictions to the use of the MOS for scientific purposes.


Subject(s)
Humans , Female , Young Adult , Middle Aged , Muscle Contraction/physiology , Pelvic Floor/physiopathology , Physical Therapy Modalities/instrumentation , Urinary Incontinence/physiopathology , Manometry/instrumentation , Palpation/instrumentation
8.
Rev. bras. eng. biomed ; 25(2): 83-87, ago. 2009. ilus
Article in English | LILACS | ID: lil-556118

ABSTRACT

O assoalho pélvico é uma estrutura muscular complexa e as disfunções uroginecológicas desta musculatura são inúmeras. O diagnóstico das disfunções uroginecológicas podem ser realizadas por anamnese, avaliação clínica (palpação digital, perineometria e observação), urodinâmica, ultrassom e ressonância magnética. Os fisioterapeutas utilizam a palpação digital vaginal para obter informações de força da musculatura do assoalho pélvico. O objetivo do presente trabalho foi desenvolver um dispositivo eletromecânico, capaz de simular in vitro o músculo levantador do ânus, a fim de treinar futuros examinadores na sensibilidade do toque digital vaginal. Cinco molas foram fixadas em um modelo anatômico de resina da pelve em uma configuração que poderia representar o músculo elevador do ânus. Uma unidade de tração composta por motor de passo interligado a uma célula de carga foi utilizada para a caracterização da força de tração do sistema mecânico. Uma fisioterapeuta bem treinada realizou quatorze séries de palpação bidigital entre as cinco molas. Neste sentido, foi possível estabelecer valores de força que se correlacionavam com os seis graus da escala modificada de Oxford. As forças médias para todas as palpações bidigitais foram comparadas usando-se o teste de ANOVA de um fator controlável. De acordo com os resultados, o grau zero representou o alongamento nulo das molas. Os graus de 1 a 5 mostraram os seguintes valores médios de força: 1 (55,69 N), 2 (56,17 N), 3 (56,94 N), 4 (59,61 N), 5 (65,36 N). O dispositivo proposto apresentou-se como uma útil ferramenta para estabelecer a relação entre a força das molas e a escala modificada de Oxford.


The pelvic floor is a complex muscular structure and the urogynaecological dysfunctions of this muscular structureare innumerable. The diagnosis of these urogynaecological dysfunctions can be performed by anamnesis, clinical evaluation (digital palpation, perineometry and observation), urodynamics and by ultrasound or magnetic resonance imaging. Physiotherapist relies on vaginal digital palpation to obtain relevant data about pelvic floor strength. The aim of the present application was to develop an electromechanical device able to simulate in vitro the levator ani muscle in order to train the sensitivity of future examiners during a vaginal digital palpation. Five springs were fixed on a resin anatomical model of the human pelvis in a configuration that could represent the levator ani muscle. A traction unit composed by a load cell and a step motor was used to produce the traction of the springs being able to measure the traction force. One well trained physiotherapist executed all the fourteen series of digital palpation procedures between the five springs. It was possible to establish force values that were correlated to the six scores of the modified Oxford scale. The meanforces obtained for the complete digital assessment were compared using one-way ANOVA. According to the results, score 0 of the modified Oxford scale represented no elongation of the springs. Scores 1 to 5 showed the following mean force values: 1 (55.69 N), 2 (56.17 N), 3 (56.94 N), 4 (59.61 N), 5 (65.36 N). The proposed device presented itself as a useful tool which is able to establish a relation between the forces of the springs and the modified Oxford scale.


Subject(s)
Anal Canal/pathology , Kinesiology, Applied/instrumentation , Palpation/instrumentation , Palpation , Pelvic Floor , Urinary Incontinence , Risk Measurement Equipment , Muscle Contraction , Muscle Strength , Musculoskeletal Manipulations/instrumentation , Physical Therapy Modalities/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL