Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Japanese Journal of Cardiovascular Surgery ; : 122-125, 2017.
Article in Japanese | WPRIM | ID: wpr-379312

ABSTRACT

<p>A 76-year-old woman required aortic valve replacement due to severe aortic stenosis. She had a huge thyroid cancer, which invaded the innominate and left internal jugular veins. We planned a two-stage operation : the first involved aortic valve replacement ; and the second involved operation of the thyroid cancer. To avoid median sternotomy, we adopted the right parasternal approach. A 7-cm right parasternal skin incision was made. The third and fourth costal cartilages were cut and bent into the right thoracic cavity, without removal of the ribs. The postoperative course was uneventful, and second operation was performed via the median sternotomy approach on postoperative day 53. The right parasternal approach can be used as an alternative when sternotomy is unsuitable in cases of aortic valve replacement.</p>

2.
Chinese Journal of Thoracic and Cardiovascular Surgery ; (12): 584-589, 2016.
Article in Chinese | WPRIM | ID: wpr-505279

ABSTRACT

Objective To evaluate the safety aod efficacy of device closure of ventricular septal defect (VSD) through parasternal approach,and to compare the advantages and disadvantages of three approaches.Methods Between Jan 2012 and Jul 2015,209 cases(Group A) underwent per-ventricular device closure of VSD through a left parasternal approach,and 36 cases(Group B) underwent per-atrial device closure of VSD through a fight parasternal approach,and 49 cases(Group C) underwent per-ventricular device closure of VSD through a median sternotomy approach.In group A,a 1.0 to 2.0 cm left parasternal iucision was made in the fourth or third intercostal space.Press the right ventricular(RV) free wall to select the puncture point.After securing double purse-string suture around the optimal puncture site,the occluder was introduced via a sheath inserted directly into the RV and navigation and positioning of the device guided by transesophageal echocardiography(TEE).In group B,a 1.0 to 2.0 cm right parasternal incision was made in the fourth or third intercostal space.After securing double purse-string suture at the right atrium near the atrioventricular groove,a specially designed hollow probe was inserted into the right atrium and was passed through the tricuspid valve into the right ventricle.The tip of the probe was manipulated to aim at or cross VSD,and a spring guide-wire was inserted into the left veotricle(LV) through the channel of the probe under TEE guidance.Then the delivery sheath was positioned into LV passing over the wire,and the device was pushed into the sheath and was deployed to finish closure.In group C,after a 1.5 to 3.0 cm median sternal incision was made,the closure of VSD was finished as the same procedure as in group A.Results There was no significant differences at the age and weight between 3 groups,as well as the size of VSD and devices.But the position of VSD varied between 3 groups.The rate of successful closure in group A (98.1%,205/209) and B (97.2%,35/36) was similar to group C (97.9%,48/49).The mean intracardiac manipulating time was shorter in group A(10 ± 6) min and group C (7 ± 5) min than in group B(19 ± 11) min.The mean time of skin cut to suture was shorter in group A(40 ± 15) min and group B(43 ± 17) min than in group C(55 ±21) min.And the average hospitalization time in group A (5.9 ± 2.2) days and group B (5.5 ± 2.7) days was shorter than in group C (8.3 ± 3.6) days.During the follow-up period of 1 to 40 months,no obvious residual leakage,arrhythmia or valvular inadequacy were found in all cases,and no device dropped out.Conclusion Minimally invasive technique of device closure of VSD through parasternal approach appears to be safe and effective,further reducing trauma and recovering faster than median sternal approach.Accurate and all-round TEE evaluation is very important to case selection of VSD.Individually procedure approach should be performed according to the size,position,and path and flow direction of VSD.

3.
Japanese Journal of Cardiovascular Surgery ; : 216-219, 2010.
Article in Japanese | WPRIM | ID: wpr-362012

ABSTRACT

A 79-year-old man developed congestive heart failure. He was given a diagnosis of severe mitral regurgitation with calcification of the posterior mitral annulus and secondary tricuspid regurgitation. He had a history of esophageal resection with retrosternal gastric tube reconstruction about 20 years previously. We replaced the mitral valve with a mechanical prosthesis and performed tricuspid ring annuloplasty through a right parasternal approach. We did not risk resecting the calcified annulus, but fixed the prosthesis and annulus with the equine pericardium in between as a cushion and collar, to prevent perivalvular leakage. The postoperative course was uneventful.