Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Journal of the Korean Shoulder and Elbow Society ; : 229-236, 2015.
Article in English | WPRIM | ID: wpr-770726

ABSTRACT

BACKGROUND: Twenty-six patients (12 male and 14 female) with symptomatic scapular winging caused by serratus anterior dysfunction were managed by split pectoralis major tendon transfer (sternal head) with autogenous hamstring tendon augmentation from 1998 to 2006. METHODS: Twenty-five patients showed positive results upon long thoracic nerve palsy on electromyography. The mean duration of symptoms until surgery was 48 months (range, 12-120 months). Four patients had non-traumatic etiologies and 22 patients had traumatic etiologies. On follow-up assessment for functional improvement, a Constant-Murley score was used. Twenty-one patients were completely evaluated, while five patients who had less than 12 months of follow-up were excluded. RESULTS: Pain relief was achieved in 19 of the 21 patients, with 20 patients showing functional improvement. The pain scores improved from 6.0 preoperatively to 1.8 postoperatively. The mean active forward elevation improved from 108degrees (range, 20degrees-165degrees) preoperatively to 151degrees (range, 125degrees-170degrees) postoperatively. The mean Constant-Murley score improved from 57.7 (range, 21-86) preoperatively to 86.9 (range, 42-98) postoperatively. A recurrence developed in one patient. Of the 21 patients, ten had excellent results, six had good results, four had fair results, and one had poor results. CONCLUSIONS: Most patients with severe symptomatic scapular winging showed functional improvement and pain relief with resolution of scapular winging.


Subject(s)
Humans , Male , Electromyography , Follow-Up Studies , Paralysis , Recurrence , Retrospective Studies , Scapula , Tendon Transfer , Tendons , Thoracic Nerves , Wings, Animal
2.
Clinics in Shoulder and Elbow ; : 229-236, 2015.
Article in English | WPRIM | ID: wpr-197183

ABSTRACT

BACKGROUND: Twenty-six patients (12 male and 14 female) with symptomatic scapular winging caused by serratus anterior dysfunction were managed by split pectoralis major tendon transfer (sternal head) with autogenous hamstring tendon augmentation from 1998 to 2006. METHODS: Twenty-five patients showed positive results upon long thoracic nerve palsy on electromyography. The mean duration of symptoms until surgery was 48 months (range, 12-120 months). Four patients had non-traumatic etiologies and 22 patients had traumatic etiologies. On follow-up assessment for functional improvement, a Constant-Murley score was used. Twenty-one patients were completely evaluated, while five patients who had less than 12 months of follow-up were excluded. RESULTS: Pain relief was achieved in 19 of the 21 patients, with 20 patients showing functional improvement. The pain scores improved from 6.0 preoperatively to 1.8 postoperatively. The mean active forward elevation improved from 108degrees (range, 20degrees-165degrees) preoperatively to 151degrees (range, 125degrees-170degrees) postoperatively. The mean Constant-Murley score improved from 57.7 (range, 21-86) preoperatively to 86.9 (range, 42-98) postoperatively. A recurrence developed in one patient. Of the 21 patients, ten had excellent results, six had good results, four had fair results, and one had poor results. CONCLUSIONS: Most patients with severe symptomatic scapular winging showed functional improvement and pain relief with resolution of scapular winging.


Subject(s)
Humans , Male , Electromyography , Follow-Up Studies , Paralysis , Recurrence , Retrospective Studies , Scapula , Tendon Transfer , Tendons , Thoracic Nerves , Wings, Animal
3.
Journal of the Korean Shoulder and Elbow Society ; : 236-239, 2009.
Article in Korean | WPRIM | ID: wpr-48714

ABSTRACT

PURPOSE: We wanted to evalulate the clinical results of pectoris major tendon transfer for a neglected winged scapula that was caused by paralysis of the serratus anterior due to injury to the long thoracic nerve. MATERIALS AND METHODS: A patient had neglected winged scapula that followed an arthroscopic operation for multi-directional instability of the shoulder joint, which was caused by traumatic dislocation. The patient was treated with pectoralis major tendon transfer using the modified Eden-Lange procedure. The range of a motion was improved from forward flexion 90degrees and external rotation 70degrees to 170degrees and 150degrees respectively. RESULTS AND CONCLUSION: There were no complications or recurrence and the patient's psychological satisfaction was also high. If the shoulder girdle muscles are intact, except for the serratus anterior, then pectoralis tendon transfer is a satisfactory method that can provide normal scapulo-thoracic motion.


Subject(s)
Humans , Joint Dislocations , Muscles , Paralysis , Recurrence , Scapula , Shoulder , Shoulder Joint , Tendon Transfer , Tendons
SELECTION OF CITATIONS