Rev. chil. enferm. respir ; 28(3): 229-235, set. 2012. ilus
Article in Spanish | LILACS | ID: lil-656317

ABSTRACT

Ultrasound is an alternative technique for the examination of the chest. Recently chest ultrasound has expanded its use mainly on the study of pediatric patients, since it does not use radiation and it is considered by some authors as the first line test in the evaluation of some specific conditions like: superficial lumps and bumps of the chest wall, diaphragm motility, thymus characterization and pleural effusions. The purpose of this paper is to review the main indications for pediatric chest ultrasound in non-cardiac diseases.


El ultrasonido es un examen complementario en el estudio por imágenes del tórax. En los últimos tiempos se ha ampliado su utilización especialmente en el estudio del tórax pediátrico ya que es una alternativa de imagen que no usa radiación y por otra parte, es considerado por algunos autores como el examen de primera línea en la evaluación de algunas patologías específicas como: aumento de volumen superficial de la pared torácica, movimiento diafragmático, timo y derrame pleural. El objetivo de este artículo es revisar las principales indicaciones en el estudio del tórax pediátrico por ultrasonido en patología no cardiológica.


Subject(s)
Child , Thoracic Diseases , Thorax , Ultrasonography , Pleural Cavity , Mediastinum , Pediatrics
2.
Korean Journal of Radiology ; : 610-617, 2012.
Article in English | WPRIM | ID: wpr-228972

ABSTRACT

OBJECTIVE: To investigate radiation doses in pediatric chest radiography in a national survey and to analyze the factors that affect radiation doses. MATERIALS AND METHODS: The study was based on the results of 149 chest radiography machines in 135 hospitals nationwide. For each machine, a chest radiograph was obtained by using a phantom representing a 5-year-old child (ATOM(R) dosimetry phantom, model 705-D, CIRS, Norfolk, VA, USA) with each hospital's own protocol. Five glass dosimeters (M-GD352M, Asahi Techno Glass Corporation, Shizuoka, Japan) were horizontally installed at the center of the phantom to measure the dose. Other factors including machine's radiography system, presence of dedicated pediatric radiography machine, presence of an attending pediatric radiologist, and the use of automatic exposure control (AEC) were also evaluated. RESULTS: The average protocol for pediatric chest radiography examination in Korea was 94.9 peak kilovoltage and 4.30 milliampere second. The mean entrance surface dose (ESD) during a single examination was 140.4 microgray (microGy). The third quartile, median, minimum and maximum value of ESD were 160.8 microGy, 93.4 microGy, 18.8 microGy, and 2334.6 microGy, respectively. There was no significant dose difference between digital and non-digital radiography systems. The use of AEC significantly reduced radiation doses of pediatric chest radiographs (p < 0.001). CONCLUSION: Our nationwide survey shows that the third quartile, median, and mean ESD for pediatric chest radiograph is 160.8 microGy, 93.4 microGy, and 140.4 microGy, respectively. No significant dose difference is noticed between digital and non-digital radiography systems, and the use of AEC helps significantly reduce radiation doses.


Subject(s)
Child, Preschool , Humans , Phantoms, Imaging , Radiation Dosage , Radiography, Thoracic , Republic of Korea , Risk Factors