Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Journal of the Korean Fracture Society ; : 145-148, 2018.
Article in Korean | WPRIM | ID: wpr-738444

ABSTRACT

A 22-year-old female patient visited the emergency room (ER) after a pedestrian traffic accident in a drunken state. An examination at the ER revealed fractures at the right side of the sacral ala, sacral foramina, left anterior acetabulum, right inferior ramus, and right superior articular process of S1. She underwent spino-pelvic fixation and iliosacral (IS) screw fixation. One year later, bone union was completed and implant removal was performed and the treatment was completed without complications. The authors recommend spino-pelvic fixation and IS screw fixation for unstable sacral fractures as one of the excellent methods for obtaining posterior stability of the pelvis among the various treatments of unstable sacral fractures.


Subject(s)
Female , Humans , Young Adult , Accidents, Traffic , Acetabulum , Emergency Service, Hospital , Pelvis
2.
Hip & Pelvis ; : 57-62, 2015.
Article in English | WPRIM | ID: wpr-7046

ABSTRACT

Percutaneous iliosacral screw fixation is commonly practiced to treat unstable posterior pelvic ring injuries. The number of reported cases of iatrogenic complications is increasing. We present a case of superior gluteal artery injury during bilateral percutaneous iliosacral screw fixation in a patient with sacral fracture of spino-pelvic dissociation. This complication was managed by arterial embolization. We discussed the cause, prevention and treatment of arterial injury along with a review of literature.


Subject(s)
Humans , Arteries
3.
Journal of the Korean Fracture Society ; : 178-183, 2013.
Article in Korean | WPRIM | ID: wpr-82170

ABSTRACT

PURPOSE: To evaluate the outcomes of surgical treatment modality in unstable sacral fractures combined with spinal and pelvic ring injury depending on the presence of spino-pelvic dissociations. MATERIALS AND METHODS: The subjects were 16 patients, with unstable sacral fractures combined with spinal and pelvic ring injuries, were operated from July 2004 to January 2011. The patients were divided into 2 groups depending on the presence of spino-pelvic dissociations: those with dissociations were group 1, and those without dissociations were group 2. Group 1 was treated with spino-pelvic fixations using iliac screw, while group 2 was treated with percutaneous iliosacral screw fixations. The availability of the radiological bony union with its application periods, and clinical results using visual analogue scale (VAS) and oswestry disability index (ODI) were evaluated, retrospectively. RESULTS: Out of 16 patients, 8 patients in group 1 were treated with spino-pelvic fixation using iliac screw, and 8 patients in group 2 were treated with percutaneous iliosacral screw fixation. The mean bony union period was 17.4 weeks in group 1, and 19.6 weeks in group 2. The Mean VAS and ODI scores on the last follow-up were 2.5 points and 15.6 points in group 1, 2 points and 18.8 points in group 2, respectively. Both groups had favorable clinical results at the last follow-up. CONCLUSION: For surgical treatments of unstable sacral fractures, spino-pelvic fixation using iliac screws is advised for cases with combined spino-pelvic dissociation, while percutaneous iliosacral screw fixation is advised for cases without combined dissociation.


Subject(s)
Humans , Dissociative Disorders , Follow-Up Studies
4.
Journal of the Korean Fracture Society ; : 243-249, 2012.
Article in Korean | WPRIM | ID: wpr-197706

ABSTRACT

PURPOSE: To analyze the clinical and radiological results of the different fixation methods according to the type and displacement of unstable pelvic ring injuries. MATERIALS AND METHODS: Twenty-three patients with unstable pelvic ring injuries from January 2005 to December 2009 were classified according to the AO/OTA classification system. When patients had been diagnosed with unstable pelvic ring injuries with partial instability, they were treated by anterior fixation with a plate and posterior percutaneous iliosacral screw fixation. When patients had been diagnosed with unstable pelvic ring injuries with complete instability, they were treated by open reduction and anterior to posterior fixation with a plate through the ilioinguinal approach. The radiological results were evaluated using Matta and Saucedo's method, and the clinical results were evaluated using Rommens and Hessmann's method. RESULTS: The outcomes from the radiological evaluation were that the displacement of the posterior pelvic ring were improved by about 6.65 mm in unstable pelvic ring injuries with partial instability. The displacement of the posterior pelvic ring were improved by about 7.8 mm in unstable pelvic ring injuries with complete instability. The clinical results were excellent in 13 cases and good in 6 cases on latest follow-up. CONCLUSION: Good results can be achieved by selecting the treatment method according to the type of unstable pelvic ring injurie and displacement.


Subject(s)
Humans , Displacement, Psychological
5.
The Journal of the Korean Orthopaedic Association ; : 1-7, 2009.
Article in Korean | WPRIM | ID: wpr-643923

ABSTRACT

PURPOSE: A closed reduction of the posterior arch and percutaneous fixation with S1 and S2 iliosacral (IS) screw was performed on an unstable pelvis fracture with a disruption of the sacroiliac complex. The radiological and clinical results were analyzed according the number of screws and their position. MATERIALS AND METHODS: Of 31 cases with an unstable pelvis fracture involving the sacral complex, classified as Tile type C (AO/OTA), 16 and 15 cases were treated with one S1 screw fixation and two screws fixation into S1 and S2, respectively, using a percutaneous fixation technique. The patients were followed up for a minimum of 12 months and the radiological and clinical outcomes were analyzed statistically using the Majeed score and SF-36. RESULTS: Five cases of screw displacement occurred in the one screw fixation group. On the other hand, there was no screw displacement in the two screws fixation group after a mean follow-up of 40.2 months. In the case of a narrow safe zone (iliac cortical density, ICD), it is impossible to fix with two S1 screws. However, in these patients, good clinical results were achieved with S1 and S2 were achieved with S1 and S2 screw without complications. CONCLUSION: The technique of two screws fixation is an efficient and reliable method for reducing and fixing the unstable pelvic ring disruptions. Additional S2 screw fixation is recommended for patients with a narrow ICD.


Subject(s)
Humans , Displacement, Psychological , Follow-Up Studies , Hand , Pelvis
6.
The Journal of the Korean Orthopaedic Association ; : 1-7, 2005.
Article in Korean | WPRIM | ID: wpr-656555

ABSTRACT

PURPOSE: This study evaluated the surgical outcomes of percutaneous iliosacral screw fixation for an unstable pelvic ring injury. MATERIALS AND METHODS: Twenty patients (20 cases) who were classified as having a Tile classification type B or C pelvic ring injury. Anterior fixation was added in 17 cases to maintain the stability of the anterior pelvic structre. The radiological results were compared using Slatis and Karaharju's method and the clinical results before and after surgery were compared using Moon's method between before and after surgery. RESULTS: The outcomes of the radiological evaluation were excellent in 19 cases, good in 1. The outcomes of the clinical evaluation were excellent in 7 cases, good in 12, and poor in 1. There were similar clinical and radiological results regardless of the number of screws. One patient complained of mild discomfort in the screw entry site. Nonunion developed in one case. However, there was no lloss of fixation observed. No neurological or vascular complications were encountered during the procedure. CONCLUSION: Satisfactory outcomes could be obtained without serious complications after percutaneous iliosacral screws in the unstable pelvic ring fractures. One iliosacral screw fixation provided for the stability in a pelvic ring injury in association with anterior fixation.


Subject(s)
Humans , Classification
7.
The Journal of the Korean Orthopaedic Association ; : 1087-1092, 1999.
Article in Korean | WPRIM | ID: wpr-647613

ABSTRACT

PURPOSE: To evaluate and analyse the operative results of percutaneous iliosacral screw fixation in displaced posterior pelvic ring injuries. MATERIALS AND METHODS: Fourteen consecutive patients with displaced posterior pelvic ring injuries (August 1995-June 1998) treated by percutaneous iliosacral screw fixation were reviewed. We analysed the pattern of fracture, associated injury and method of operation including patient's position, complication and functional result. RESULTS: Seventeen iliosacral screws under fluoroscopic guidance were applied in fourteen patients. During the operations various positions of patients were possible, and all cases were treated with closed reduction and percutaneous iliosacral screw fixation except in one case (open reduction and percutaneous screw fixation). Fixation of associated anterior pelvic ring injury was undertakes in eight cases. Screw-related neurovascular injury and other complications such as breakage, loosening, misplacement and redisplacement, nonunion and screw site infection during follow-up period were not found. Satisfactory clinical and radiologic results were achieved during follow-up period except in one case (limping due to leg length discrepancy, malreduction) in this study. CONCLUSION: Precise understanding of iliosacral anatomy and its variants, proper patient positioning and appropriate intraoperative interpretation of fluoroscopic iliosacral image are mandatory. We believe percutaneous iliosacral screw fixation is a useful addition to treatment options for unstable posterior pelvic ring injury.


Subject(s)
Humans , Follow-Up Studies , Leg , Patient Positioning
8.
The Journal of the Korean Orthopaedic Association ; : 391-398, 1997.
Article in Korean | WPRIM | ID: wpr-643992

ABSTRACT

In the past two decades, open reduction and internal fixation has been the preferred treatment of posterior pelvic ring disruption with instability. Despite of rigid fixation, it can induce bleeding, wound infection, wound necrosis and prolong operation time in the patient with combined injuries. To compensate for these disadvantages, we have implemented closed reduction and percutaneous iliosacral fixation under fluoroscopy in reducible posterior pelvic ring disruption. In spite of anatomical risk during screw insertion, the percutaneous iliosacral screw technique after closed reduction of the posterior pelvic ring disruption minimally violates the soft tissue envelope and reduces both the operative blood loss and infection rate. We are reporting the early results of our 6 patients treated between Aug. 1995 to Aug. 1996. The operation time was shorter than open reduction and internal fixation. There was no significant bleeding, wound infection and nerve injury by screws.


Subject(s)
Humans , Fluoroscopy , Hemorrhage , Necrosis , Wound Infection , Wounds and Injuries
SELECTION OF CITATIONS
SEARCH DETAIL