Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 22
Filter
1.
Rev. bras. ortop ; 58(1): 67-71, Jan.-Feb. 2023. tab, graf
Article in English | LILACS | ID: biblio-1441342

ABSTRACT

Abstract Objective To compare the measurement of patellar height in the pre- and postoperative period of total knee arthroplasties (TKAs) and its variation in patients with and without patellar replacement. Methods Retrospective evaluation of radiographs of patients submitted to TKA between 2014 and 2020. Profile radiographs were evaluated using the modified Caton-Deschamps patellar height index, comparing the pre- and postoperative measurements of 90 patients, with a total of 100 knees. Next, two groups were compared with a different surgical technique, considering the replacement or not of the patella. All patients who had x-rays evaluated had indication of TKA by osteoarthrosis without previous procedures that could interfere at patellar height. Results The statistical analysis showed a statistically significant difference, with the preoperative index superior to the postoperative rate, evidencing an overall decrease in patellar height. The Caton-Deschamps index modified for mean preoperative TKA was 1.41 (±0.25), and it was 1.31 (± 0.25), p< 0.001for postoperative TKA. No significant difference was found in the variation of this index when comparing the groups with and without patellar replacement. The mean difference of the index in the group without patella was 0.11, and 0.08 in the group with patella, and this difference was considered nonsignificant, p= 0.510. Conclusion We can conclude that patellar height had significant variation in the total group, with reduction of patellar height in the postoperative period. However, the height did not vary significantly between the postoperative groups with and without patellar replacement, regardless of the choice of the surgeon.


Resumo Objetivo Comparar a medida da altura patelar no pré- e pós-operatório das artroplastias totais do joelho (ATJs) e sua variação nos pacientes com e sem substituição patelar. Métodos Avaliação retrospectiva de radiografias de pacientes submetidos a ATJ entre 2014 e 2020. Foi feita a avaliação de radiografias em perfil, usando o índice de altura patelar de Caton-Deschamps modificado, comparando as medidas do pré- e pós-operatório de 90 pacientes, totalizando 100 joelhos. A seguir, foi feita a comparação de dois grupos, com técnica cirúrgica distinta, considerando a substituição ou não da patela. Todos os pacientes que tiveram radiografias avaliadas tiveram indicação de ATJ por osteoartrose sem procedimentos prévios que pudessem interferir na altura patelar. Resultados A análise estatística demonstrou uma diferença estatisticamente significativa, sendo o índice pré-operatório superior ao pós-operatório; evidenciando um abaixamento global da altura patelar. O índice Caton-Deschamps modificado para ATJ pré-operatório médio foi de 1,41 (±0,25), e o pós foi de 1,31 (±0,25), p< 0,001. Não foi encontrada diferença significativa na variação deste índice quando comparados os grupos com e sem substituição patelar. A diferença média do índice no grupo sem patela foi de 0,11 e no grupo com patela foi de 0,08, sendo esta diferença considerada não significativa, p= 0,510. Conclusão Podemos concluir que a altura patelar teve variação significativa no grupo total, com redução da altura patelar no pós-operatório. Entretanto, a altura não variou de forma significativa entre os grupos pós-operatórios com e sem substituição patelar, independentemente da opção do cirurgião.


Subject(s)
Humans , Patella/surgery , Arthroplasty, Replacement, Knee , Knee Prosthesis
2.
Rev. bras. ortop ; 57(5): 734-740, Sept.-Oct. 2022. tab, graf
Article in English | LILACS | ID: biblio-1407689

ABSTRACT

Abstract Objective The management of bone loss represents a challenge in revisions of total knee arthroplasty (rTKA) and in complex primary total knee arthroplasties (TKAs). The purpose of the present study was to evaluate the midterm outcomes (5-year minimum follow-up) of knee reconstructions with tantalum trabecular metal (TM) cones on bone defects Anderson Orthopaedics Research Institute (AORI) 2 and 3. Materials and MethodsA retrospective analysis of the medical records of patients operated on between July 2008 and November 2014 was performed, collecting the following data: age, gender, laterality, body mass index, etiology of arthrosis, comorbidities, AORI classification of bone defects, causes for revision, readmissions, reoperations, perioperative and postoperative complications, radiographic signs of osteointegration, and maintenance of the TM support. Results A total of 11 patients with a mean follow-up of 7.28 years (standard deviation [SD] = 1.88; range = 5.12-10 years) was evaluated, with 1 patient operated upon for a primary arthroplasty, 6 for revision arthroplasties, and 4 for a second revision arthroplasty (re-revision). There were complications with the surgical wound, injury to the extensor mechanism and loosening of the femoral component in three of the patients that led to the necessity of four procedures due to complications with the surgical wound, injury to the extensor mechanism and loosening of the femoral component. Radiological signs of osteointegration of the trabecular cones were observed in all patients. We did not observe migration of the TM cones or the prosthetic components in the sample. Conclusion The tantalum metaphyseal cones were able to provide efficient structural support to prosthetic implants with radiographic signs of osteointegration in the medium term.


Resumo Objetivo O manejo da perda óssea representa um grande desafio em cirurgias de revisão de artroplastia do joelho (rATJ) e em artroplastias totais do joelho (ATJ) primárias complexas. O objetivo do presente estudo foi avaliar os resultados em médio prazo (seguimento mínimo de 5 anos) das reconstruções de joelho nas quais cones de metal trabecular (MT) de tântalo foram utilizados para tratamento de defeitos ósseos tipos 2 e 3, de acordo com a classificação proposta pela Anderson Orthopaedic Research Institute (AORI). Métodos Feita análise retrospectiva dos prontuários dos pacientes operados entre julho de 2008 e novembro de 2014, coletando-se os seguintes dados: idade, gênero, lateralidade, índice de massa corporal, etiologia da artrose, comorbidade, classificação AORI da falha óssea, causa da revisão da artroplastia total do joelho, reinternações, reoperações, complicações peri- e pós-operatórias, ocorrência de osteointegração radiográfica e manutenção da função de suporte do MT. Resultados Foram avaliados 11 pacientes com tempo médio de seguimento de 7,28 anos (desvio padrão [DP] = 1,88; variação = 5,12-10 anos), sendo que 1 paciente foi submetido a artroplastia primária, 6 a artroplastia de revisão e 4 a segunda revisão de artroplastia (re-revisão). Três pacientes necessitaram de quatro reoperações devido a complicações com a ferida operatória, a lesão do mecanismo extensor e a soltura do componente femoral. Sinais de osteointegração dos cones trabeculados foram observados em todos os pacientes. Não observamos migração do cone de MT ou dos componentes protéticos. Conclusão Os cones metafisários de tântalo foram capazes de prover suporte estrutural eficiente aos implantes protéticos com sinais radiográficos de osteointegração em médio prazo.


Subject(s)
Humans , Postoperative Complications , Tantalum , Retrospective Studies , Osseointegration , Outcome Assessment, Health Care , Arthroplasty, Replacement, Knee , Knee Prosthesis
3.
Rev. bras. ortop ; 56(1): 42-46, Jan.-Feb. 2021. tab, graf
Article in English | LILACS | ID: biblio-1288655

ABSTRACT

Abstract Objective To evaluate the wear of polyethylene in a Brazilian ultracongruent knee prosthesis with a rotating platform (Rotaflex, Víncula, Rio Claro, SP, Brasil). Methods We used the test method with the loading and preparation parameters mentioned in the standards regulation ISO 14243-1:2009, and the measurement methods mentioned in the standards regulation ISO 14243-2:2009, for the evaluation of the wear behavior of a Brazilian prosthesis with a rotating platform. The equipment used for the wear test was the ISO 14243-1 gait simulator (EndoLab, Riedering, Germany). Results After 10 million cycles, the evaluation of the polyethylene wear showed a regular appearance of surface wear at a mean rate of 2.56 mg per million cycles. Conclusion The wear of the polyethylene of the evaluated prosthesis was minimal after the tests performed and with safety limits higher than those recommended by biomechanical engineering.


Resumo Objetivo Avaliar o desgaste do polietileno de uma prótese de joelho brasileira ultracongruente de base rotatória (Rotaflex, Víncula, Rio Claro, SP, Brasil). Métodos Utilizou-se o método de ensaio com os parâmetros de carregamento e preparação citados na norma ISO 14243-1:2009, e os métodos de medição citados na norma ISO 14243-2:2009, para a avaliação do comportamento de desgaste de uma prótese nacional com base rotatória. O equipamento utilizado para o teste de desgaste foi o simulador de marcha ISO 14243-1 (EndoLab, Riedering, Alemanha). Resultados Após 10 milhões de ciclos, a avaliação do desgaste do polietileno mostrou uma aparência regular do desgaste da superfície com taxa média de 2,56 mg por milhão de ciclos. Conclusão O desgaste do polietileno da prótese avaliada foi mínimo após os ensaios realizados e com os limites de segurança superiores aos preconizados pela engenharia biomecânica.


Subject(s)
Prostheses and Implants , Prosthesis Failure , Arthroplasty, Replacement, Knee , Equipment and Supplies , Knee Prosthesis
4.
Rev. bras. ortop ; 53(2): 151-157, Mar.-Apr. 2018. tab, graf
Article in English | LILACS | ID: biblio-899256

ABSTRACT

ABSTRACT Objective: To present the indications, technical aspects, and initial results of the first cases using Endo-Model™ implants in Brazil. Methods: A prospective study was conducted. It included nine patients submitted to a total knee arthroplasty, of which six were primary and three were revisions, using exclusively the Endo-Model™ implant. These patients were followed for an average of 12 months and evaluated with functional scores, such as the Knee injury and Osteoarthritis Outcome Score (KOOS), Knee Society Score (KSS), and visual analog pain scale (VAS). Results: There were statistically significant improvements in all scores evaluated in every patient. Only one complication occurred postoperatively (apraxia of the peroneal nerve) and did not require surgery revision. Conclusion: The use of a rotating-hinge implant for knee arthroplasty is a new option for complex cases with severe instability in Brazil; the initial results are satisfactory.


RESUMO Objetivo: Apresentar as indicações, os aspectos técnicos e os resultados iniciais dos primeiros casos do uso do implante constrito Endo-Model® no Brasil. Métodos: Foi conduzido um estudo prospectivo que incluiu nove pacientes submetidos a artroplastia total de joelho, seis primárias e três revisões, exclusivamente com o implante Endo-Model®. Esses pacientes foram acompanhados por uma média de 12 meses e avaliados com os escores funcionais do Knee Injury and Osteoarthritis Outcome Score (KOOS), Knee Society Score (KSS) e escala visual analógica de dor (EVA). Resultados: Todos os escores avaliados apresentaram melhorias estatisticamente significantes em todos os pacientes. Somente uma complicação pós-operatória foi observada (apraxia do nervo fibular), sem necessidade de revisão da cirurgia. Conclusão: O uso de implante em dobradiça rotatória em artroplastia de joelho é uma nova opção para casos complexos com instabilidade grave no Brasil, com resultados iniciais satisfatórios.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Aged, 80 and over , Arthroplasty, Replacement, Knee , Joint Instability , Knee Joint , Knee Prosthesis , Range of Motion, Articular
5.
Rev. bras. ortop ; 52(3): 242-250, May.-June 2017. tab
Article in English | LILACS | ID: biblio-899147

ABSTRACT

ABSTRACT Total knee arthroplasty (TKA) is a surgical procedure of paramount relevance that restores a substantial degree of function in arthritic knees. Increased consideration has been given to the influence of limb alignment on longevity after TKA, as errors in component placement can be associated with inferior function and compromised long-term performance. Consequently, numerous studies comparing patient-specific instrumentation (PSI) to standard instruments (SI) have been published. Patient-specific approaches use preoperative imaging to create specific materials for each patient's anatomy and were designed to achieve a higher rate of success in TKA, causing the entire procedure to be more efficient and cost-effective. However, it is not clear to what degree these studies support the potential advantages of PSI. Thus, the present study aimed to review the current evidence comparing PSI to SI, concerning alignment, cost-effectiveness, and postoperative functional evaluation.


RESUMO A artroplastia total do joelho (ATJ) é um procedimento cirúrgico de fundamental relevância que restaura boa parte da função de joelhos artríticos. Maior atenção tem sido dada à influência do alinhamento do membro na longevidade após a ATJ, uma vez que erros no posicionamento dos componentes podem estar associados a uma menor função e comprometimento do desempenho em longo prazo. Consequentemente, vários estudos compararam a instrumentação personalizada para cada paciente (IPP) com a instrumentação padrão (IP). As abordagens personalizadas usam imagens pré-operatórias para criar materiais específicos para a anatomia de cada paciente e foram projetados para atingir uma maior taxa de sucesso na ATJ e tornar todo o processo mais eficiente e rentável. No entanto, não está claro até que ponto tais estudos respaldam as vantagens potenciais da IPP. Assim, o presente estudo teve como objetivo avaliar as evidências atuais e comparar IPP e IP com respeito ao alinhamento, à relação custo-benefício e à avaliação funcional pós-operatória.


Subject(s)
Arthroplasty , Arthroplasty, Replacement, Knee , Knee Prosthesis , Patient-Specific Modeling
6.
Rev. bras. anestesiol ; 66(3): 254-258, May.-June 2016. tab, graf
Article in English | LILACS | ID: lil-782889

ABSTRACT

ABSTRACT BACKGROUND AND OBJECTIVES: The use of tranexamic acid in primary total knee replacement surgeries has been the subject of constant study. The strategies to reduce bleeding are aimed at reducing the need for blood transfusion due to the risks involved. In this study we evaluated the use of tranexamic acid in reducing bleeding, need for blood transfusion, and prevalence of postoperative deep vein thrombosis in primary total knee replacement. METHOD: 62 patients undergoing primary total knee replacement were enrolled in the study, from June 2012 to May 2013, and randomized to receive a single dose of 2.5 g of intravenous tranexamic acid (Group TA) or saline (Group GP), 5 min before opening the pneumatic tourniquet, respectively. Hemoglobin, hematocrit, and blood loss were recorded 24 h after surgery. Deep vein thrombosis was investigated during patient's hospitalization and 15 and 30 days after surgery in review visits. RESULTS: There was no demographic difference between groups. Group TA had 13.89% decreased hematocrit (p = 0.925) compared to placebo. Group TA had a decrease of 12.28% (p = 0.898) in hemoglobin compared to Group GP. Group TA had a mean decrease of 187.35 mL in blood loss (25.32%) compared to group GP (p = 0.027). The number of blood transfusions was higher in Group GP (p = 0.078). Thromboembolic events were not seen in this study. CONCLUSION: Tranexamic acid reduced postoperative bleeding without promoting thromboembolic events.


RESUMO JUSTIFICATIVA E OBJETIVOS: O uso do ácido tranexâmico, em cirurgias de artroplastia total primária de joelho, tem sido objeto de constante estudo. As estratégias para redução de sangramento visam à redução da necessidade de transfusão de sangue devido aos riscos que apresentam. Neste estudo, propomos a avaliação do uso do ácido tranexâmico na redução do sangramento, na necessidade de transfusão de sangue e na prevalência de trombose venosa profunda (TVP) pós-operatória em artroplastia total primária de joelho. MÉTODO: Foram estudados 62 pacientes submetidos à artroplastia primária total de joelho, de junho de 2012 a maio de 2013, randomizados para receber ácido tranexâmico 2,5 g endovenoso (grupo AT), em dose única, ou soro fisiológico (grupo GP), cinco minutos antes da abertura do torniquete pneumático, respectivamente. Foram feitas dosagens de hemoglobina e hematócrito e medida a perda sanguínea 24 horas após a cirurgia. A TVP foi pesquisada durante a internação do paciente, 15 e 30 dias após a cirurgia nas consultas de revisão. RESULTADOS: Não houve diferenças demográficas entre os grupos estudados. O grupo GT apresentou queda do hematócrito 13,89% (p = 0,925) comparado com o grupo placebo. O grupo GT apresentou diminuição de 12,28% (p = 0,898) da hemoglobina comparado com o grupo GP. O grupo GT apresentou uma diminuição média de 187,35 ml nas perdas sanguíneas (25,32%) quando comparado com o grupo GP (p = 0,027). O número de transfusões sanguíneas foi maior no grupo GP (p = 0,078). Eventos tromboembólicos não foram evidenciados neste estudo. CONCLUSÕES: O ácido tranexâmico diminuiu o sangramento pós-operatório sem promover eventos tromboembólicos.


Subject(s)
Humans , Male , Female , Aged , Postoperative Complications/prevention & control , Tranexamic Acid/therapeutic use , Blood Loss, Surgical/statistics & numerical data , Postoperative Hemorrhage/prevention & control , Arthroplasty, Replacement, Knee , Antifibrinolytic Agents/therapeutic use , Blood Transfusion/statistics & numerical data , Hemoglobins/drug effects , Venous Thrombosis/prevention & control , Hematocrit/statistics & numerical data , Middle Aged
7.
Einstein (Säo Paulo) ; 14(1): 77-98, Jan.-Mar. 2016. tab, graf
Article in English | LILACS | ID: lil-778491

ABSTRACT

Abstract The purpose of this study was to evaluate the effects of neuromuscular electrical stimulation in patients submitted to total knee arthroplasty. This was a systematic review with no language or publication status restriction. Our search was made in Cochrane Library, MEDLINE, Embase and LILACS. Randomized or quasi-randomized clinical trials evaluating neuromuscular electrical stimulation after total knee arthroplasty were included. Four studies with moderate risk of bias and low statistical power were included, totalizing 376 participants. There was no statistically significant difference in knee function, pain and range of motion during 12 month follow-up. This review concluded that neuromuscular electrical stimulation was less effective than traditional rehabilitation in function, muscular strength and range of motion. However, this technique was useful for quadriceps activation during the first days after surgery.


Resumo O objetivo deste estudo foi avaliar os efeitos da estimulação elétrica neuromuscular em pacientes submetidos à artroplastia total de joelho. Esta foi uma revisão sistemática sem restrição de idioma ou status de publicação. Nossa pesquisa foi realizada na biblioteca Cochrane, MEDLINE, Embase e LILACS. Foram incluídos ensaios clínicos randomizados ou quase-randomizados, avaliando a estimulação elétrica neuromuscular após a artroplastia total de joelho. Quatro estudos com risco de viés moderado e de baixo poder estatístico foram incluídos, totalizando 376 participantes. Não houve diferença estatisticamente significativa na função do joelho, dor e amplitude de movimento durante 12 meses de seguimento. Esta avaliação concluiu que a estimulação elétrica neuromuscular foi menos eficaz do que a reabilitação tradicional na função, força muscular e amplitude de movimento. No entanto, essa técnica é útil para a ativação do quadríceps durante os primeiros dias após a cirurgia.


Subject(s)
Humans , Electric Stimulation Therapy/methods , Publication Bias , Arthroplasty, Replacement, Knee/rehabilitation , Osteoarthritis, Knee/rehabilitation , Quadriceps Muscle , Postoperative Care/rehabilitation , Randomized Controlled Trials as Topic , Electric Stimulation Therapy/adverse effects , Treatment Outcome , Evidence-Based Medicine/standards , Osteoarthritis, Knee/surgery
8.
Rev. bras. ortop ; 50(3): 290-294, May-Jun/2015. tab, graf
Article in English | LILACS | ID: lil-753152

ABSTRACT

OBJETIVO:Avaliar os resultados, em médio e longo prazo, das artroplastias totais de joelho com apoio tibial rotatório.MÉTODOS:De janeiro de 2000 a julho de 2007, 162 pacientes foram submetidos à artroplastia total do joelho com apoio tibial móvel. Desses, 96 foram avaliados em um estudo prévio com tempo de seguimento médio de quatro anos. No atual trabalho, esse mesmo grupo foi convocado para reavaliação e os resultados foram analisados. Responderam à atual convocação 69 pacientes (79 joelhos), que foram avaliados conforme o Knee Society Rating System (KSRS), após seguimento médio de oito anos e oito meses (variação entre 5,5 e 13 anos).RESULTADOS:Foi obtida pontuação média de 74,41 pontos no KSRS, com 78,7% de resultados bons ou excelentes.CONCLUSÃO:A artroplastia total do joelho com apoio tibial móvel obteve bons resultados em médio e longo prazo e atingiu a média de 74,41 pontos no Knee Society Clinical Rating System.


OBJECTIVE: To evaluate the medium and long term results from total knee arthroplasty with rotating tibial weight-bearing. METHODS: Between January 2000 and July 2007, 162 patients underwent total knee arthroplasty with mobile tibial weight-bearing. Among these, 96 were evaluated in a previous study with a mean follow-up of 4 years. In the present study, the same group was invited back for reassessment and the results were analyzed. Sixty-nine patients responded to this call (79 knees), and they were evaluated in accordance with the Knee Society Rating System (KSRS), after a mean follow-up of 8 years and 8 months (ranging from 5.5 and 13 years). RESULTS: A mean KSRS score of 74.41 points was obtained, with good or excellent results. CONCLUSION: The medium and long-term results from total knee arthroplasty with mobile tibial weight-bearing were good, and a mean score of 74.41 points in the Knee Society Clinical Rating System was attained.


Subject(s)
Humans , Male , Female , Middle Aged , Aged, 80 and over , Arthroplasty, Replacement , Knee , Knee Prosthesis , Osteoarthritis
9.
Rev. Assoc. Med. Bras. (1992) ; 61(1): 40-43, Jan-Feb/2015.
Article in English | LILACS | ID: lil-744716

ABSTRACT

Objective: the aim of this study is to evaluate the change in length of hospital stay postoperatively for Total Knee Arthroplasty after using femoral and sciatic nerve block. Materials and methods: the medical records of 287 patients were evaluated, taking into account the number of hours of admission, the percentage and the reason for re-hospitalization within 30 days, as well as associated complications. All patients were divided into two groups according or not to whether they were admitted to ICU or not. During the years 2009 and 2010, isolated spinal anesthesia was the method used in the procedure. From 2011 on, femoral and sciatic nerve blocking was introduced. Results: between the years 2009 and 2012, the average length of stay ranged from 74 hours in 2009 to 75.2 hours in 2010. The average length of stay in 2011 was 56.52 hours and 53.72 hours in 2012, all in the group of patients who did not remain in the ICU postoperatively. In the same period, among those in the group that needed ICU admission, the average length of stay was 138.7 hours in 2009, 90.25 hours in 2010, 79.8 hours in 2011, and 52.91 hours in 2012. During 2009 and 2010, the rate of re-hospitalization was 0%, while in 2011 and 2012, were 3.44% and 1%, respectively. Conclusion: according to this study, the use of femoral and sciatic nerve blocking after total knee arthroplasty allowed significant reduction in hospital stay. .


Objetivo: avaliar a mudança no tempo de permanência hospitalar (PH) no pós-operatório de artroplastia total do joelho (ATJ) após a utilização do bloqueio dos nervos femoral e ciático. Métodos: os prontuários de 287 pacientes foram avaliados, levando-se em consideração o número de horas de internação, o percentual e o motivo de reinternação em 30 dias, bem como as complicações associadas, sendo divididos em dois grupos de acordo com a permanência ou não no centro de terapia intensiva (CTI). Durante os anos de 2009 e 2010, a anestesia utilizada para a realização dos procedimentos foi a raquianestesia isolada. A partir de 2011, o bloqueio dos nervos femoral e ciático foi introduzido. Resultados: no período entre 2009 e 2012, o tempo médio de PH variou entre 74 horas, em 2009, e 75,2 horas, em 2010. A PH média em 2011 foi de 56,52 horas e de 53,72 horas em 2012, no grupo de pacientes que não permaneceram no CTI no pós-operatório. No mesmo período, no grupo que precisou de internação no CTI, a PH média foi de 138,7 horas em 2009; 90,25 horas em 2010; 79,8 horas em 2011 e 52,91 horas em 2012. Em 2009 e 2010, a taxa de reinternação foi de 0%, e em 2011 e 2012, 3,44% e 1%, respectivamente. Conclusão: de acordo com este estudo, a utilização do bloqueio dos nervos femoral e ciático após a ATJ permitiu a redução significativa da PH. .


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Arthroplasty, Replacement, Knee , Length of Stay/statistics & numerical data , Nerve Block/methods , Pain, Postoperative/therapy , Sciatic Nerve , Anesthesia, Spinal , Cross-Sectional Studies , Pain Measurement , Retrospective Studies
10.
Acta ortop. bras ; 21(1): 23-26, jan.-fev. 2013. tab
Article in Portuguese | LILACS | ID: lil-670852

ABSTRACT

Objetivo: Mostrar nossa experiência com haste não-cimentadas press-fit e fixação metafisária com cimento em série selecionada de pacientes que realizaram revisão de artroplastia total do joelho. Métodos: Trinta e quatro pacientes (35 joelhos) foram submetidos a revisão de artroplastia total do joelho usando técnica "press-fit". Seguimento mínimo foi de um ano (média de 2,2 anos) e máximo de três anos. Resultados: Dos 34 pacientes, 20 foram mulheres e 14 foram homens. Houve um óbito por causa não relacionada a artroplastia e perda de seguimento de um paciente. Não houve nenhum caso em que fosse necessária nova revisão. Os pacientes que foram submetidos à revisão apresentaram melhora clínica e funcional demonstrado pelos resultados do KSS, resultados do questionário de qualidade de vida SF-36, através do ganho de amplitude de movimento e da melhora no alinhamento do membro. Conclusão: Houve melhora clínica e funcional no pós-operatório em relação ao pré-operatório na revisão de artroplastia total do Joelho com haste não cimentada "press-fit". Nível de Evidência IV, Série de casos.


Objective: To show our experience with press-fit cementless stem and metaphyseal fixation with cement in a selected series of patients who underwent revision total knee arthroplasty. Methods: Thirty-four patients (35 knees) underwent revision total knee arthroplasty using the press-fit technique. Minimum follow-up was one year (mean 2.2 years) with a maximum length of three years. Results: Of 34 patients, 20 were women and 14 were men. There was one death due to causes not related to arthroplasty and one patient dropout. There were no cases in which further review was necessary. Patients who underwent revision had clinical and functional improvement demonstrated by the results of the KSS, results of the SF-36 quality of life questionnaire, through gains in range of motion and improved limb alignment. Conclusion: There was postoperative clinical and functional improvement in comparison to the preoperative status in revision total knee arthroplasty with press-fit cementless stem. Level of Evidence IV, Case series.


Subject(s)
Middle Aged , Aged, 80 and over , Arthroplasty, Replacement, Knee/rehabilitation , Knee Prosthesis , Osteoarthritis, Knee/surgery , Range of Motion, Articular , Quality of Life , Surveys and Questionnaires , Radiography
11.
Acta ortop. bras ; 20(4): 230-234, 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-644436

ABSTRACT

OBJETIVO: Comparar dois métodos de avaliação da estabilidade dos componentes tibial e femoral nas artroplastias de joelho não cimentadas com plataforma rotatória. MÉTODOS: Para isso foram avaliados 20 pacientes (20 joelhos) através de uma análise de radiografias dinâmicas com intensificador de imagem e manobras de estresse em varo e valgo, que foram comparadas com radiografias estáticas em frente e perfil dos joelhos, analisadas por dois cirurgiões experientes, cegos um em relação ao outro. RESULTADOS: Os resultados das análises estáticas e dinâmicas foram comparados e demonstraram forte correlação estatística (p<0,001), utilizando-se o método Kappa de comparação. CONCLUSÃO: O componente tibial mostrou-se mais instável quando comparado com o componente femoral, tanto na análise estática, quanto na dinâmica. Nível de evidência IV, Série de Casos.


Objetives: Determine the stability of tibial and femoral components of 20 cementless knee arthroplasties with rotating platform. METHODS: The 20 patients (20 knees) underwent an analysis of dynamic radiographs with an image amplifier and maneuvers of varus and valgus which were compared to static frontal and lateral radiographs of the knees and analyzed by two experienced surgeons in a double-blind way. RESULTS: We could observe in this study that both methods showed very similar results for the stability of the tibial and femoral components (p<0,001) using the Kappa method for comparison. CONCLUSION: The tibial component was more unstable in relation to the femoral component in both static and dynamic studies. Level of evidence IV, Case Series.


Subject(s)
Humans , Male , Female , Arthroplasty, Replacement, Knee/rehabilitation , Femur , Knee Prosthesis , Osteoarthritis, Knee/surgery , Tibia , Data Interpretation, Statistical
12.
Rev. bras. ortop ; 46(5): 540-545, set.-out. 2011. ilus, tab
Article in Portuguese | LILACS | ID: lil-611416

ABSTRACT

OBJETIVO: A pesquisa analisa 47 pacientes submetidos à artroplastia total de joelho (ATJ) com implante de fabricação nacional com seguimento médio de cinco anos. MÉTODOS: No período compreendido entre janeiro de 1993 a dezembro de 2002 foi realizado um estudo retrospectivo no Hospital da Santa Casa de Misericórdia do Rio de Janeiro. A casuística foi de 47 pacientes totalizando 58 joelhos submetidos à ATJ, sendo 44 do sexo feminino e três do sexo masculino. A idade dos pacientes variou de 46 a 83 anos. O diagnóstico de osteoartrose ou doença reumática foi confirmado em todos os pacientes. RESULTADOS: Na pesquisa todos os casos foram submetidos à ATJ cimentada e com preservação do ligamento cruzado posterior. O tempo de seguimento dos pacientes variou de 5 a 17 anos. O critério de avaliação funcional usado foi o do Hospital for Special Surgery (HSS) e obtivemos a média de 87 pontos no pós-operatório. Na avaliação radiográfica utilizamos os critérios da Knee Society Total Knee Arthroplasty Roentgenographic Evaluation and Scoring System e obtivemos três casos com uma linha radioluscente sem soltura do implante e assintomáticos do ponto de vista clínico. CONCLUSÃO: A artroplastia total do joelho com implante de fabricação nacional realizado por equipe treinada e experiente, até o presente momento, demonstrou um resultado satisfatório no seguimento clínico em pacientes com osteoartrose do joelho ou artrite reumatóide.


OBJECTIVE: This study assessed 47 patients who underwent total knee arthroplasty (TKA) with implants manufactured in Brazil, with a mean follow-up of five years. METHODS: This was a retrospective study at Santa Casa de Misericordia Hospital in Rio de Janeiro, from January 1993 to December 2002. The sample comprised 47 patients (44 females and three males) who underwent TKA, totaling 58 knees. The patients' ages ranged from 46 to 83 years. A diagnosis of osteoarthritis or rheumatic disease was confirmed in all the patients. RESULTS: In this investigation, all the patients underwent cemented TKA with preservation of the posterior cruciate ligament. The length of follow-up ranged from 5 to 17 years. The functional assessment criterion used was the one of the Hospital for Special Surgery (HSS), and this yielded an average of 87 points after the operation. The radiographic criterion used was the Knee Society Total Knee Arthroplasty Roentgenographic Evaluation and Scoring System. We had three cases with a radiolucent line without implant loosening, which were asymptomatic from a clinical standpoint. CONCLUSION: The total knee arthroplasty procedures using an implant made in Brazil were performed by a trained and experienced team. To date, over the clinical follow-up on these patients with knee osteoarthritis or rheumatoid arthritis, the results have been seen to be satisfactory.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged, 80 and over , Arthroplasty, Replacement, Knee , Evaluation of Results of Therapeutic Interventions , Knee Prosthesis , Retrospective Studies
13.
Acta ortop. bras ; 19(6): 368-372, 2011. ilus, tab
Article in Portuguese | LILACS | ID: lil-610494

ABSTRACT

OBJETIVO: Considerando a dificuldade para classificar os defeitos ósseos foi feito estudo para avaliar se a classificação de falha óssea da AORI baseada na radiografia pré-operatória é fidedigna e reprodutível entre diferentes médicos. MÉTODOS: Seis ortopedistas com subespecialização em cirurgia do joelho foram treinados para o uso da classificação radiográfica. Esses cirurgiões avaliaram e classificaram isoladamente as falhas ósseas de 26 radiografias de próteses de joelho pré revisão. RESULTADOS: Constatou-se que houve coincidência de >50 por cento (correlação moderada) da classificação em 24 dos 26 casos no fêmur e em 22 dos 26 casos na tíbia; e correlação de >80 por cento (boa correlação) em 12 dos 26 casos no fêmur e em sete dos 26 casos na tíbia. CONCLUSÃO: Em relação à concordância da classificação, observamos que a classificação AORI apresenta moderada correlação inter-observadores. Nível de evidência III, Estudo de pacientes não consecutivos; sem padrão de referencia "ouro" aplicado uniformemente.


OBJECTIVE: Considering the difficulty for classifying bone losses the present study was designed to analyse if the AORI classification based on pre-operative radiographies is consistent and reproductible between different orthopaedic surgeons. METHODS: Six orthopedists specialized in knee surgery were trained for the use of the classification based on radiographic evaluation. All the surgeons individually classified 26 pre operative knee radiographs. RESULTS: There was a moderate (> 50 percent) matching of the classification in 24 of 26 cases in the femur and 22 of 26 in the tibia. A good matching (> 80 percent) was present in 12 of 26 cases in the femur and in 7 of 26 cases in the tibia. CONCLUSION: We observed that the AORI classification presented a moderate radiographic correlation between surgeons. Evidence of level III, Study of nonconsecutive patients; without consistently applied reference ''gold'' standard.


Subject(s)
Humans , Arthroplasty, Replacement, Knee , Mentoring/methods , Knee , Femur/pathology , Osteolysis , Tibia/pathology
14.
Rev. bras. ortop ; 46(1): 27-30, 2011. ilus
Article in Portuguese | LILACS | ID: lil-596351

ABSTRACT

OBJETIVO: Relatar os resultados iniciais com o uso de nova técnica para a fixação de enxerto ósseo em falhas ósseas tibiais não contidas em pacientes submetidos à prótese total de joelho. MÉTODOS: Seis pacientes com deformidade grave em varo do joelho que, após a realização dos cortes e balanço ligamentar, ainda apresentavam falhas ósseas avançando até à margem do corte tibial e que comprometiam a estabilidade do implante, foram submetidos a uma nova técnica de fixação. RESULTADOS: Cinco dos pacientes apresentaram bom resultado clínico, com integração do enxerto em até 12 semanas. Um paciente apresentou complicação clínica com deiscência da ferida e exposição da prótese, evoluindo para a retirada do implante e artrodese do joelho. CONCLUSÃO: A osteossíntese de suporte como método de fixação do enxerto é uma opção viável para o tratamento das falhas ósseas tibiais. A técnica proposta certamente necessita de mais estudos para a sua validação.


OBJECTIVE: To report the initial results from the use of a new technique for fixation of bone grafts in uncontained tibial bone defects in patients undergoing total knee prosthesis implantation. METHODS: Six patients with severe varus deformity of the knee who, after cuts and ligament balancing had been performed, still presented bone deficiencies that reached the edge of the tibial cut and compromised the implant stability, underwent a new fixation technique. RESULTS: Five of the patients had good clinical results, with integration of the graft within 12 weeks. One patient presented clinical complications with wound dehiscence and implant exposure, which evolved to the need for implant removal and knee arthrodesis. CONCLUSION: Support osteosynthesis as a graft fixation method is a viable option for treating tibial bone deficiencies. The proposed technique certainly needs further studies for its validation.


Subject(s)
Humans , Male , Female , Arthroplasty , Bone Transplantation , Knee Prosthesis
15.
Acta ortop. bras ; 19(4): 184-188, 2011. ilus, graf
Article in Portuguese | LILACS | ID: lil-601824

ABSTRACT

OBJETIVO: Avaliar se a cirurgia auxiliada por navegação oferece vantagens sobre a técnica convencional, foi desenvolvido um estudo randômico, prospectivo e comparativo analisando o posicionamento do implante, alinhamento do membro, tempo de cirurgia, perda sanguínea e reabilitação funcional. MÉTODOS: Foram estudados 39 pacientes submetidos a 42 Artroplastias Totais de Joelho. No grupo 1 (n=21) a cirurgia foi navegada e no grupo 2 (n=21) convencional. Os pacientes foram avaliados com radiografia panorâmica de membros inferiores, tomografia computadorizada e pelo Knee Society Score (KSS) no pré-operatório e com três meses de pós-operatório. O tempo de cirurgia e a perda sanguínea pós-operatória também foram avaliados. RESULTADOS: O tempo de cirurgia foi maior no grupo 1. Não houve diferença significativa quanto à perda sanguínea e ao KSS. Houve maior proximidade dos três graus de rotação externa e dos cinco graus de inclinação coronal nos pacientes do grupo 2. O eixo mecânico aproximou-se mais de zero grau no grupo 1. CONCLUSÕES: A navegação promove um posicionamento individualizado dos componentes da prótese oferecendo vantagens no realinhamento do membro. O tempo cirúrgico tende a ser maior na técnica navegada, porém, não foi estatisticamente significante. Não há diferenças na perda sanguínea e na melhora do KSS. Nivel de Evidência I, estudo terapeutico.


OBJECTIVE: Aiming to evaluate whether surgery aided navigation offers any advantages over the conventional technique, a randomized, prospective, comparative study was carried out, analyzing the placement of components, alignment of the limb, surgical time, blood loss and functional rehabilitation. MATERIAL AND METHODS: We studied 39 patients submitted42 Total Knee Arthroplasties. In group 1 (n = 21) the surgery was navigated and in group 2 (n = 21) it was conventional. The patients were evaluated on panoramic radiographs of the lower limbs, CT scan and the Knee Society Score (KSS) preoperatively and three months postoperatively. Surgery time and postoperative blood loss were also evaluated. RESULTS: Surgery time was longer in group 1. There was no significant difference in blood loss and the KSS. There was a greater proximity of the three degrees of external rotation and the five degrees of tilt in the coronal in group 2. The mechanical axis was closer to zero degree in group CONCLUSIONS: Navigation promotes individualizing of the positioning of the components of the prosthesis, and offered advantages in limb realignment, compared with traditional methods. The surgerytime has a tendency to be higher in group 2, but this difference is not statistically significant. There were no differences between the groups in relation to blood loss and improvement in KSS. Level of Evidence: Level I, therapeutic studies.


Subject(s)
Humans , Arthroplasty, Replacement, Knee/methods , Knee Prosthesis , Surgery, Computer-Assisted , Brazil , Hemostasis, Surgical , Knee , Prospective Studies , Surgical Procedures, Operative
16.
Acta ortop. bras ; 18(5): 242-244, 2010. ilus
Article in Portuguese | LILACS | ID: lil-562078

ABSTRACT

OBJETIVO: Confirmar por análise fluoroscópica a movimentação rotacional do insert de polietileno em artroplastias totais de joelho (ATJ) de plataforma rotatória, após um tempo pós operatório mínimo de seis meses, foram estudados 15 joelhos, submetidos a ATJ de plataforma rotatória, com a prótese NEW WAVE, da LEPINE. MÉTODOS: Foi utilizado para a avaliação da rotação do insert de polietileno através de um aparelho de fluoroscopia numa visão anteroposterior do joelho com 90º de flexão. Caso a imagem do marcador radiopaco do polietileno permanecesse inalterada, ou seja, acompanhasse o fêmur, era considerado então que a rotação estaria ocorrendo entre o insert e o componente tibial. RESULTADOS: Dos 15 joelhos analisados, 14 apresentaram movimentação demonstrável do insert de polietileno, totalizando 93,3 por cento. Para que a ATJ de plataforma rotatória mantenha seu potencial é necessário que a movimentação rotacional do insert de polietileno se mantenha com o tempo. CONCLUSÃO: Com estudo dessa amostra concluiu-se que a rotação se mantém de forma consistente (93 por cento). Sugerindo que a ATJ de plataforma rotatória tem efetivamente o potencial de apresentar menor desgaste do polietileno pela maior congruência articular, em relação à ATJ de apoio fixo, além da vantagem de auto-alinhamento do mecanismo extensor.


OBJECTIVE: To confirm by fluoroscopic analysis the rotational movement of the polyethylene insert in rotating platform total knee arthroplasty (TKA) after a minimum postoperative time of six months. Fifteen knees submitted to rotating platform TKA with the LEPINE NEW WAVE prosthesis were studied. METHODS: A fluoroscopic appliance in an anterior-posterior view of the proximal tibia was used to evaluate the rotation of the polyethylene insert, with the knee at a 90º flexion. If the image of the polyethylene radiopaque marker remained unchanged, i.e. if it accompanied the femur, then it was considered that rotation was occurring between the insert and the tibial component. RESULTS: Of the fifteen knees analyzed, fourteen displayed demonstrable movements of the polyethylene insert, totaling 93.3 percent. For the rotating platform TKA to maintain its potential, the rotating movements of the polyethylene insert must be maintained over time. CONCLUSION: The study of this sample demonstrated that the rotation is consistently maintained (93 percent). This confirmation suggests that rotating platform TKA effectively has the potential to present lower polyethylene wear due to the higher articulation congruence, compared with fixed support TKA, besides having the additional advantage of self-alignment of the extensor mechanism.


Subject(s)
Humans , Male , Female , Arthroplasty, Replacement, Knee , Knee Prosthesis , Fluoroscopy/methods , Polyethylene , Rotation
17.
Acta ortop. bras ; 18(6): 310-314, 2010. ilus, tab
Article in Portuguese | LILACS | ID: lil-570530

ABSTRACT

OBJETIVO: Avaliações dos resultados a médio prazo da aplicação da prótese com apoio tibial móvel. MÉTODOS: Noventa e seis pacientes (107 joelhos) foram submetidos a artroplastia total do joelho realizada com um modelo de prótese com mobilidade rotatória no componente tibial. Os pacientes foram avaliados após um seguimento médio de 52,7 meses - desvio padrão 21,94 (mínimo de 24 meses e máximo de 120 meses), através do protocolo de avaliação "Knee Society Clinical Rating System" (KSCRS), com uma média de 78,22 pontos. RESULTADOS: Entre as complicações transoperatórias e pós operatórias imediatas ocorreram uma deiscência de sutura, com cura espontânea, duas fraturas de patela, uma fratura do côndilo medial do fêmur, três paresias do nervo fibular lateral e uma distrofia nervosa simpático reflexa. As complicações tardias foram uma fratura da patela, uma fratura distal do fêmur, quatro solturas assépticas e quatro infecções profundas, que necessitaram de revisão. CONCLUSÃO: Excluindo-se os casos que necessitaram de uma revisão, por soltura séptica ou asséptica, os autores concluem serem bons os resultados clínicos e funcionais obtidos com a prótese com o apoio tibial móvel num seguimento a médio prazo.


OBJECTIVE: Evaluation of mid-term follow up results of the application of a total knee replacement with a mobile tibial bearing design. METHODS: Ninety six patients (107 knees) were submitted to total knee Arthroplasty, performed with a model of prosthesis with rotating mobility in the tibial component. The patients were evaluated after a mean follow-up of 52.7 months - standard deviation 21.94 (minimum 24 months and maximum 120 months) through the Knee Society Clinical Rating System (KSCRS), with a mean outcome of 78.22 points. RESULTS: The complications that occurred immediately after or during the surgery included: one wound dehiscence with spontaneous healing, two patellar fractures, one fracture of the medial condyle of the femur, three peroneal nerve impairments, and one sympathetic reflex nervous distrophy. Subsequent complications were: one patellar fracture, one distal fracture of the femur, four aseptic loosenings and four deep joint infections, which required arthroplastic revisions. CONCLUSION: With the exception of the cases requiring arthroplastic revision due to septic or aseptic loosening, the authors conclude that the clinical and functional results obtained with Total Knee Replacement with a mobile bearing component, in a mid-term follow-up, were good.


Subject(s)
Humans , Arthroplasty, Replacement, Knee , Knee Prosthesis , Postoperative Complications , Surgical Wound Dehiscence , Evaluation of Results of Therapeutic Interventions , Radiography, Panoramic/methods
18.
São Paulo med. j ; 127(4): 190-197, July 2009. graf, tab
Article in English | LILACS | ID: lil-533441

ABSTRACT

CONTEXT AND OBJECTIVE: Total knee arthroplasty (TKA) has evolved particularly since the 1970s, with improvements in implants and surgical instruments, and has thus become an effective intervention for treating knee arthrosis. Many studies have presented rates of satisfactory clinical and radiological results greater than 90 percent, from follow-ups of over ten years. Nevertheless, despite scientific evidence showing the efficacy of TKA, the approaches taken present controversies in certain respects. The objective of this study was to evaluate how the Brazilian orthopedists deal with TKA, with investigation of the main aspects of this procedure. DESIGN AND SETTING: Cross-sectional survey conducted during the 39th Brazilian Congress of Orthopedics and Traumatology, in São Paulo, Brazil, in November 2007. METHODS: We applied a questionnaire to orthopedists registered at the congress. The questionnaire was randomly distributed and participation was voluntary; 858 completed questionnaires were included in the analysis. RESULTS: Most of the Brazilian orthopedists were members of SBOT and worked in the southeastern region. They used imported cemented implants through an anterior access route centered on the patella, with replacement of the joint surface of the patella and preservation of the posterior cruciate ligament. They did not have experience with simultaneous bilateral TKA. Postoperatively, they used antibiotics and suction drains for 48 hours. There was no consensus regarding prophylaxis for venous thromboembolism or the frequency of the main complications. CONCLUSION: The majority of Brazilian orthopedists work in the southeastern region of the country and agree about the main aspects of the approaches towards TKA.


CONTEXTO E OBJETIVO: A artroplastia total do joelho (ATJ) evoluiu sobremaneira desde os anos 70, com melhora dos implantes e do instrumental cirúrgico, tornando-se uma intervenção efetiva para o tratamento da artrose do joelho. Muitos estudos apresentam resultados clínicos e radiológicos satisfatórios superiores a 90 por cento no acompanhamento acima de 10 anos. Apesar das evidências científicas sobre sua eficácia da ATJ, a sua abordagem apresenta controvérsias em alguns aspectos. O objetivo do estudo foi avaliar como o ortopedista brasileiro aborda a ATJ e os principais aspectos técnicos na realização deste procedimento. TIPO DE ESTUDO E LOCAL: Estudo transversal, realizado durante o 39º Congresso Brasileiro de Ortopedia e Traumatologia em São Paulo, Brasil, em novembro de 2007. MÉTODOS: Aplicamos um questionário aos ortopedistas inscritos no congresso. A distribuição foi aleatória com adesão voluntária. Foram incluídos 858 questionários para análise. RESULTADOS: A maioria dos Ortopedistas Brasileiros são membros da SBOT e atua na região sudeste. Usam o implante importado, cimentado, por via de acesso anterior centrada na patela, com substituição da superfície articular da patela e preservação do ligamento cruzado posterior e não tem experiência com a artroplastia total bilateral simultânea. No pós-operatório utilizam antibióticos e dreno de sucção por 48 horas. Não houve consenso quanto à profilaxia para tromboembolismo venoso e frequência das principais complicações. CONCLUSÃO: A maioria dos ortopedistas brasileiros trabalha na região sudeste e concorda quanto aos principais aspectos da abordagem da ATJ.


Subject(s)
Humans , Arthroplasty, Replacement, Knee/methods , Orthopedics/statistics & numerical data , Practice Patterns, Physicians'/statistics & numerical data , Arthroplasty, Replacement, Knee/statistics & numerical data , Brazil , Cross-Sectional Studies , Health Care Surveys
19.
Rio de Janeiro; s.n; maio 2009. [14] p.
Non-conventional in Portuguese | LILACS, ColecionaSUS | ID: biblio-931535

ABSTRACT

Foram analisados,prospectivamente, 200 artroplastias totais do joelho do tipo condilar cimentada, em pacientes portadores de osteoartrose e artrite reumatóide, entre junho de 2007 e janeiro de 2008. A finalidade do estudo foi avaliar a perda sanguinea com utilização de drenagem de sucção pós artroplastia. Foram mensuradas as taxas de hemoglobina antes e depois da cirurgia e a relação destas com a necessidade de transfusão. Avaliou-se também a significância de alguns fatores adicionais como: tipo de acesso,liberação da isquemia seguida de hemostasia ou liberação da isquemia pós-curativo. A análise dos resultados demonstrou diminuição da hemoglobina e hematócrito no período pós-operatório, porém sem significância estática, independente da abordagem cirúrgica seguida durante o procedimento, não existindo ainda evidências de superioridade de um tipo de planejamento cirúrgico a se seguir


Subject(s)
Male , Female , Humans , Middle Aged , Aged, 80 and over , Arthroplasty, Replacement, Knee/methods , Blood Loss, Surgical/statistics & numerical data , Postoperative Hemorrhage , Brazil , Hemostasis, Surgical/statistics & numerical data , Knee Prosthesis , Suction , Wounds and Injuries/surgery
20.
Rev. bras. ortop ; 44(1): 46-51, jan.-fev. 2009. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-572658

ABSTRACT

OBJETIVO: As endopróteses parciais de joelho para as ressecções em sarcomas ósseos demonstram serem boa solução para o tratamento de pacientes com imaturidade esquelética. O objetivo deste estudo é avaliar o escore funcional, as vantagens, as desvantagens e indicações para esta técnica cirúrgica em quatorze pacientes em um protocolo brasileiro de osteossarcoma e sarcoma de Ewing. MÉTODOS: Análise retrospectiva realizada para identificar a evolução funcional e as possíveis complicações do procedimento. 14 pacientes com idade entre 10 e 22 anos avaliados funcionalmente pelos critérios de Enneking/ISOLS (International Society of Limb Salvage), sendo todos operados na mesma Instituição e pelo mesmo cirurgião. Foram utilizadas endopróteses parciais das extremidades distal do fêmur e proximal da tíbia com reconstrução ligamentar. ReSULTADOS: A análise do escore funcional de Enneking/ISOLS demonstrou 78,6 por cento de excelentes resultados e 21,4 por cento de bons. Dos 14 pacientes, todos portadores de tumores primitivos ósseos em protocolo de quimioterapia, nove não apresentaram nenhum tipo de complicação e cinco indivíduos evoluíram com complicações relacionadas ao procedimento, sendo que houve relação estatística positiva entre os maus resultados e a presença de complicações (p=0,027). CONCLUSÃO: As endopróteses parciais de joelhos são menos prejudiciais ao estoque ósseo de pacientes com esqueleto imaturo. As críticas sobre os maus resultados funcionais estão sendo suplantadas pelas novas técnicas de reconstrução, corretos protocolos de reabilitação, qualidade e tecnologia dos implantes, e o aumento da curva de aprendizado. Essa opção de tratamento per-mite a preservação do estoque ósseo e a possibilidade de revisão da artroplastia não convencional de modo menos agressivo.


OBJECTIVE: Partial knee endoprosthesis to bone sarcomas resections seems to be a good solution to treat this immature skeletal patients. The purpose of this study is to evaluate the functional score in fourteen patients, advantages and the technique indications. METHODS: Retrospective analysis was done to assess in this group of patients the functional evolution and the possible complications of the procedure. 14 patients between 10 and 22 years functionally evaluated in Ennekin/ISOLS (International Society of Limb Salvage) criteria, being all of them operated in the same institution by the same surgeon. Were used distal femur and proximal tibia partial endoprosthesis. RESULTS: General analysis demonstrated that the functional results were over than 67 percent (ISOLS criteria) in 78,6 percent of the patients, being considered excellent. 21,4 percent were considered good results, being between 50 and 66 percent. Bone storage was preserved when avoiding the adjacent segment resection. Surgery time was not prolonged in ligament reconstruction. CONCLUSION: Knee partial endoprosthesis are less damage to bone storage in young patients. The critics about the bad functional results are being supplied by new surgical techniques, excellent rehabilitation protocols, implants technology and the consequent learning curve. This option of treatment permits the preservation of healthy bone and provides the possibility of a revision replacement less aggressive.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Knee , Knee Prosthesis , Osteosarcoma , Retrospective Studies , Sarcoma, Ewing
SELECTION OF CITATIONS
SEARCH DETAIL