Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 20
Filter
1.
Medisan ; 27(5)oct. 2023. tab
Article in Spanish | LILACS, CUMED | ID: biblio-1529003

ABSTRACT

Introducción: La rehabilitación cardiaca en pacientes con prótesis valvular es esencial para aumentar su sobrevida e incorporarlos óptimamente a la sociedad. Objetivo: Caracterizar a pacientes con prótesis valvular mecánica y rehabilitación cardiovascular. Métodos: Se realizó un estudio observacional, descriptivo, de serie de casos, de 70 pacientes con prótesis valvular mecánica, admitidos en el programa de rehabilitación cardiovascular del Hospital General Universitario Vladimir Ilich Lenin de la provincia de Holguín, desde marzo del 2019 hasta noviembre del 2022. Resultados: Predominaron los pacientes de 55 a 64 años de edad (38,6 %), con prótesis en posición mitral, sin complicaciones. En los sujetos rehabilitados se observó una reducción de la media de hipercolesterolemia (de 250 a 175 mg/dL) y un aumento de la capacidad funcional por la duración del ejercicio, así como de las unidades metabólicas consumidas. La media de la función ventricular izquierda tras la terapia rehabilitadora se incrementó de 52,4 a 58,2 %. Solo 2 afectados necesitaron rehospitalización e incorporar más fármacos a su tratamiento basal y 50 retornaron a sus actividades laborales. El resultado fue satisfactorio en 97,1 % de los integrantes de la serie. Conclusiones: Esta terapia resultó beneficiosa, pues se incrementó la capacidad funcional de los pacientes y fueron pocas las complicaciones. Los factores de riesgo coronarios estuvieron controlados, se redujo la rehospitalización y aumentó la reincorporación laboral.


Introduction: Heart rehabilitation in patients with valvular prosthesis is essential to increase their survival and incorporate them optimally to the society. Objective: To characterize patients with mechanical valvular prosthesis and cardiovascular rehabilitation. Methods: An observational, descriptive, serial cases study of 70 patients with mechanical valvular prosthesis was carried out, who were admitted to the program of cardiovascular rehabilitation of Vladimir Ilich Lenin University General Hospital in Holguín province, from March, 2019 to November, 2022. Results: There was a prevalence of 55 to 64 years patients (38.6%), with prosthesis in mitral position, without complications. In the rehabilitated patients a reduction of the mean in hypercholesterolemia was observed (from 250 to 175 mg/dL) and an increase of the functional capacity due to the duration of exercise, as well as of the consumed metabolic units. There was an increase from 52.4 to 58.2% in the mean of the left ventricular function after the rehabilitative therapy. Only 2 affected patients needed rehospitalization and to incorporate more medication to their basal treatment and 50 returned to their working activities. The result was satisfactory in 97.1% of the series members. Conclusions: This therapy was beneficial, because there was an increase of the functional capacity of patients and complications were not very common. The coronary risk factors were controlled; there was a reduction of rehospitalization and an increase of working reincorporation.

2.
Rev. urug. cardiol ; 38(1): e404, 2023. ilus
Article in Spanish | LILACS, BNUY, UY-BNMED | ID: biblio-1450411

ABSTRACT

La enfermedad valvular cardíaca es una condición muy frecuente en la población general y un porcentaje considerable de estos pacientes requieren un tratamiento intervencionista sobre su valvulopatía para lograr atenuar su evolución natural. En este contexto, en la actualidad ha aumentado el uso de las prótesis valvulares biológicas para su tratamiento y, con ello, surge el dilema del manejo antitrombótico en estos pacientes en términos de prevención de tromboembolias y eventos hemorrágicos. ¿Cuál es el fármaco más efectivo y seguro en el período posoperatorio temprano? ¿Qué antitrombóticos podemos utilizar en el período posoperatorio tardío? ¿Qué estrategia seguimos cuando el paciente presenta otras indicaciones de anticoagulación? El objetivo de esta revisión es valorar la evidencia actual respecto al tratamiento antitrombótico en pacientes portadores de prótesis valvulares biológicas con y sin indicaciones adicionales de anticoagulación.


Heart valve disease is a very common condition in the general population and a considerable percentage of these patients require interventional treatment for their valve disease to mitigate its natural evolution. In this context, the use of biological prosthetic valves for their treatment has now increased, and with this, the dilemma of antithrombotic management in these patients arises, in terms of prevention of thromboembolism and hemorrhagic events. What is the most effective and safe drug in the early postoperative period? What antithrombotics can we use in the late postoperative period? What strategy do we follow when the patient presents other indications for anticoagulation? The objective of this review is to assess the current evidence regarding antithrombotic treatment in patients with biological prosthetic valves with and without additional indications for anticoagulation.


A valvopatia é uma condição muito comum na população geral e uma porcentagem considerável desses pacientes necessita de tratamento intervencionista para sua valvopatia para amenizar sua evolução natural. Nesse contexto, o uso de próteses valvares biológicas para seu tratamento tem aumentado, e com isso surge o dilema do manejo antitrombótico nesses pacientes em termos de prevenção de tromboembolismo e eventos hemorrágicos. Qual é o fármaco mais eficaz e seguro no pós-operatório imediato? Que antitrombóticos podemos usar no pós-operatório tardio? Que estratégia seguimos quando o paciente apresenta outras indicações de anticoagulação? O objetivo desta revisão é avaliar as evidências atuais sobre o tratamento antitrombótico em pacientes com próteses valvares biológicas com e sem indicações adicionais de anticoagulação.


Subject(s)
Humans , Thromboembolism/drug therapy , Bioprosthesis , Heart Valve Prosthesis , Fibrinolytic Agents/therapeutic use , Postoperative Complications , Postoperative Hemorrhage/drug therapy
3.
Rev. colomb. cardiol ; 29(4): 449-456, jul.-ago. 2022. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1408006

ABSTRACT

Resumen Introducción: la válvula St. Jude Trifecta® es una bioprótesis diseñada para implante en posición aórtica supraanular. Objetivo: Evaluar el comportamiento hemodinámico de la válvula y el estadio clínico de los pacientes, entre 3 a 72 meses luego del implante. Materiales y método: Estudio de cohorte en el que se incluyeron pacientes mayores de 18 años, llevados a cambio valvular aórtico en quienes se implantó una bioprótesis St. Jude Trifecta® entre marzo de 2012 a diciembre de 2018, y se hizo un seguimiento mediante evaluación clínica y ecocardiográfica desde tres meses hasta seis años posquirúrgicos. Resultados: Se incluyeron 165 pacientes, 53.3% hombres. Edad promedio 69.6 años (30-90). El 66.7% con estenosis valvular aórtica y el 21.2% con insuficiencia. El promedio de EuroSCORE II fue 4.18 (0.56-24.35). En el preoperatorio, 60.6%, 29.6% y 9.69% de los pacientes se encontraban en clase funcional NYHA II, III y IV, respectivamente. Luego del implante, el promedio de área del orificio efectivo indexado fue 1.025 cm2/m2 para bioprótesis N.o 19 1.089cm2/m2, 1.085 cm2/m2 y 1.069 cm2/m2 para prótesis N.o 21, 23 y 25, respectivamente. El gradiente medio transvalvular en el posoperatorio inmediato (en sala de cirugía) fue 3.08 mmHg. Durante el seguimiento ecocardiográfico a 3, 6, 12, 24, 36 y 72 meses, el gradiente medio fue de 4.2, 5.7, 6.3, 7.1, 8.3 y 9.1 mmHg, respectivamente. La mortalidad quirúrgica fue del 2.42%. Ningún paciente presentó desproporción prótesis-paciente, accidente cerebrovascular o endocarditis. Durante el tiempo del estudio ninguno ha requerido reintervención por deterioro valvular estructural. Al seguimiento, 83.6% se encontraron en NYHA I. Conclusión: En el grupo estudiado, el reemplazo valvular aórtico con bioprótesis St. Jude Trifecta® demostró excelentes resultados clínicos (NYHA I, 83%) y hemodinámicos (no reoperación por deterioro valvular estructural, bajos gradientes transvalvulares y adecuado orificio efectivo indexado), durante el tiempo de evaluación clínica y ecocardiográfica (3 a 72 meses).


Abstract Background: The St. Jude Trifecta™ valve is a latest generation bioprosthetic designed for supra annular aortic placement. The study main objective is the evaluation of the hemodynamic valve performance and the 3 to 72 months post implantation clinical status of the patients. Method and materials: Cohort study on patients older than 18 years, undergoing aortic valve replacement with St. Jude Trifecta™biological valve prosthesis between march 2012 and december 2018. The follow up was made by clinical evaluation and serial echocardiogram from 3 months to 6 years after surgery. Results: 165 patients where included, 53.3% male. Mean age 69.6 years (30-90). The main indication for valve replacement was aortic stenosis (66.7%). Mean EuroSCORE II was 4.18 (0.56-24.35). Preoperative 60.6%, 29.6% and 9.69% of patients where in New York Heart Association functional class (NYHA) II, III and IV respectively. After the surgery, the mean effective orifice area index (IEOA) was 1.025 cm2/m2 for prosthesis N.o 19; 1.089cm2/m2 (prosthesis 21); 1.085 cm2/m2 (prosthesis 23) and 1.069 cm2/m2 (prosthesis 25). The mean transvalvular gradient was 3.08 mmHg at the immediate posoperative period, and the mean gradient at 3,6,12,24,36 and 72 months was 4.2, 5.7, 6.3, 7.1, 8.3 and 9.1 mmHg, respectively. 30 days mortality was 2.42%. None of the patients have a posoperative patient-prosthesis mismatch (PPM), neither thromboembolic events or endocarditis. There is no patients with re-operation for structural valve deterioration. After follow up, 83.6% of the patients are in NYHA I functional class. Conclusion: In this Study group, St. Jude Trifecta™ valve for aortic valve replacement provides excellent clinical (NYHA I, 83%) and hemodynamic outcomes (demostrated by no patients with re-operation for structural valve deterioration, a low post operative transvalvular gradients; IEOA that avoid PPM; excellent clinical and echocardiographic outcome during follow up (3 to 72 months).

4.
Rev. chil. infectol ; 38(2): 260-270, abr. 2021. ilus, tab
Article in Spanish | LILACS | ID: biblio-1388227

ABSTRACT

Resumen La endocarditis infecciosa (EI) es una enfermedad de alta mortalidad, caracterizada por una infección endocárdica y frecuentes complicaciones multiorgánicas, que requiere un diagnóstico rápido y preciso, y un manejo agresivo, ya sea médico o quirúrgico. Su diagnóstico se realiza tomando en cuenta criterios bacteriológicos, clínicos y ecocardiográficos. Es objetivo de este artículo realizar una actualización del estudio imagenológico en paciente con EI, con especial énfasis en aquellos exámenes no ecocardiográficos disponibles en nuestro medio. En los últimos años, estudios de imagen avanzados han adquirido un rol creciente en su estudio inicial, particularmente la tomografía computada multicorte (TCMC) cardiaca y el positron emission tomography/computed tomography (PET/CT), y han sido recomendados como criterios diagnósticos en las guías recientes para el manejo de esta entidad. La TCMC cardiaca proporciona información anatómica detallada de las válvulas cardiacas y tejido perivalvular, identificando pseudoaneurismas, abscesos y dehiscencias valvulares. El PET/CT con F18-fluorodeoxiglucosa (F18-FDG) permite aumentar la sensibilidad en la detección de EI, y pesquisar con alta eficiencia fenómenos embólicos sistémicos, de elevada frecuencia en esta población. Ambos métodos prestan particular utilidad en EI de válvula protésica, donde la ecocardiografía presenta menor rendimiento diagnóstico. La resonancia magnética (RM) cerebral es el mejor método de imagen para descartar eventos isquémicos/embólicos del sistema nervioso central.


Abstract Infective endocarditis (IE) is an entity characterized by endocardial infection and frequent multiorgan complications, resulting in high mortality. It requires a rapid and accurate diagnosis, and a medical or surgical aggressive treatment. Currently, IE diagnosis rests on bacterial, clinical and ultrasonographic criteria. The objective of this article is to update the imaging study in patients with IE, with special emphasis on those non-echocardiographic examinations available in our environment. Last years, advanced imaging had achieved a growing role in IE diagnosis, especially cardiac multislice computed tomography (MSCT) and positron emission tomography/computed tomography (PET/CT), which have been recommended in recent clinical guidelines to be included as part of diagnostic criteria. Cardiac MSCT provides detailed anatomic information of cardiac valves and perivalve tissue, allowing identification of pseudoaneurysm, abscess and valve dehiscence. F18-FDG PET/CT increases sensitivity for IE detection and shows high accuracy in searching for extracranial systemic embolic events. Both MSCT and PET/CT have particular utility in cases of prosthetic valve endocarditis, where cardiac ultrasonography shows lower performance. Brain magnetic resonance imaging (MRI) is the best imaging method for evaluating ischemic/embolic events of central nervous system.


Subject(s)
Humans , Endocarditis/diagnostic imaging , Endocarditis, Bacterial/diagnostic imaging , Heart Valve Prosthesis/adverse effects , Ultrasonography , Radiopharmaceuticals , Fluorodeoxyglucose F18 , Positron Emission Tomography Computed Tomography
5.
CorSalud ; 12(2): 146-154, tab, graf
Article in Spanish | LILACS | ID: biblio-1133604

ABSTRACT

RESUMEN Introducción: La endocarditis infecciosa sobre prótesis valvulares cardíacas es una de las formas más graves de esta enfermedad, de difícil diagnóstico y asociada con elevada mortalidad. Objetivo: Describir las características de la endocarditis infecciosa en válvulas cardíacas protésicas. Método: Se realizó un estudio observacional, descriptivo y transversal desde 2006 hasta 2019 en el Hospital Hermanos Ameijeiras. La muestra fue de 40 pacientes. Se utilizaron estadígrafos descriptivos como la media aritmética y la desviación estándar para las variables cuantitativas continuas y el porcentaje para las cualitativas. Resultados: La edad media de los pacientes fue de 54,29±16,07 años, predominaron aquellos con edades entre 40-49 y 60-69 años (27,5%), así como del sexo masculino (67,5%), y el tipo de endocarditis más frecuente fue la tardía 65%. La sepsis oral (27,5%) y la cirugía previa (25%) fueron la puerta de entrada más frecuente. Prevalecieron los cultivos negativos (40%) y los agentes causales estafilococos coagulasa negativos (25%) y estafilococos áureos (10%). En las complicaciones predominaron las insuficiencias cardíacas (32%) y renal (22,5%), y un 20% de los casos tuvo dehiscencia de sutura. El 52,5% de los pacientes recibió tratamiento quirúrgico y la mortalidad fue del 30%. Conclusiones: Predominó la endocarditis tardía, con hemocultivo negativo y de prótesis aórtica. La dehiscencia de prótesis fue el hallazgo ecocardiográfico más encontrado y la insuficiencia cardíaca, la complicación más frecuente. El tratamiento quirúrgico fue el más utilizado y la mortalidad, ajustada para esta enfermedad, fue baja.


ABSTRACT Introduction: Infective endocarditis in prosthetic heart valves is one of the most severe forms of this disease of difficult diagnosis and associated with high mortality. Objective: To describe the characteristics of prosthetic valve endocarditis. Method: An observational, descriptive and cross-sectional study was conducted from 2006 to 2019 at Hospital Hermanos Ameijeiras. The sample consisted of 40 patients. Descriptive statistics such as arithmetic mean and standard deviation were used for continuous quantitative variables, and percentage for qualitative ones. Results: The average age of the patients was 54.29+16.07 years old, predominating those between 40-49 and 60-69 years old, as well as males (67.5%); the most frequent type of endocarditis was the late one (65%). Oral sepsis (27.5%) and previous surgery (25%) %) were the most frequent entry points. Negative cultures (40%) and coagulase-negative staphylococcus causative agents (25%) and staphylococcus aureus (10%) prevailed. Heart failure (32%) and kidney failure (22.5%) were the most frequent complications, and 20% of cases had suture dehiscence. The 52.5% of patients received surgical treatment and the mortality was of the 30%. Conclusions: Late endocarditis predominated, with negative blood cultures and of aortic valve prosthesis. Prosthesis dehiscence was the most frequent echocardiographic finding and the heart failure, the most frequent complication. The surgical treatment was the most used, and the mortality, adjusted for this disease, was low.


Subject(s)
Heart Valve Prosthesis , Mortality , Endocarditis , Endocarditis, Non-Infective
6.
Rev. colomb. cardiol ; 26(5): 296-299, sep.-oct. 2019. graf
Article in Spanish | LILACS, COLNAL | ID: biblio-1092941

ABSTRACT

Resumen Se describe el caso de una mujer de 68 años que presentaba insuficiencia tricuspídea severa con ventrículo derecho dilatado, función sistólica levemente deprimida y ventrículo izquierdo no dilatado con fracción de eyección del 47%. Se intervino mediante cirugía realizándose una sustitución valvular tricúspide por prótesis mecánica ATS n( 33 e implante de electrodo de marcapasos epicárdico definitivo. En el postoperatorio inmediato presentó ascenso persistente del segmento ST en la cara inferior. Se implantó balón de contrapulsación intraaórtico y en el ecocardiograma urgente se observó disfunción ventricular global con aquinesia de la cara inferior. Se realizó coronariografía urgente observándose una imagen de angulación y deformidad a nivel distal de la arteria coronaria derecha no presente en la coronariografía prequirúrgica que sugería tracción externa del vaso, probablemente en relación con la sutura quirúrgica. Se intervino en forma percutánea implantándose stent farmacoactivo con lo cual se recuperó el flujo distal y se normalizó el segmento ST. La proximidad del anillo tricúspide a estructuras anatómicas como la arteria coronaria derecha hace posible su lesión durante la cirugía. El daño iatrogénico de la arteria coronaria derecha requiere diagnóstico y tratamiento precoz. Por ello esta complicación se debe incluir en el diagnóstico diferencial de disfunción ventricular derecha tras cirugía cardiaca.


Abstract The case is presented on a 68 year-old woman with severe tricuspid insufficiency. She also had a dilated right ventricle, a slightly depressed systolic function, and an undilated left ventricle with an ejection fraction of 47%. We treated her surgically, the tricuspid valve replacement was carried out with an ATS Nº 33 mechanical prosthesis and implanted a permanent epicardial pacemaker lead. In the immediate post operative period, she presented a persistent ST segment elevation on the inferior wall. An intra-aortic balloon pump was implanted; the urgent echocardiogram showed a global ventricular dysfunction with akinesia of the inferior wall. An urgent coronary angiography was performed, with an image of angulation and deformity being observed at distal level of the right coronary artery that was not present in the pre-surgical coronary angiography, which suggested an external traction of the vessela probably associated with a surgical suture. Percutaneous intervention was carried out, with a drug-eluting stent being implanted. It was percutaneously treated by implanting a drug-eluting stent restoring distal blood flow and normalizing the ST segment. The proximity of the tricuspid ring to anatomical structures like the right coronary artery means that it could be damaged during surgery. The iatrogenic damage to the right coronary artery requires an early diagnosis and treatment. For this reason, this complication must be included in the differential diagnosis of right ventricular dysfunction after cardiac surgery.


Subject(s)
Humans , Female , Aged , Congenital Abnormalities , Heart Valve Prosthesis , Intraoperative Complications , Prostheses and Implants , Thoracic Surgery , Ventricular Dysfunction , Coronary Vessels
7.
Rev. urug. cardiol ; 34(1): 234-244, abr. 2019. graf
Article in Spanish | LILACS | ID: biblio-991656

ABSTRACT

Resumen: La estenosis aórtica afecta frecuentemente a la población añosa con elevada prevalencia de comorbilidades que aumentan los riesgos quirúrgicos. La sustitución valvular aórtica por vía percutánea ha demostrado su utilidad en pacientes de moderado a muy alto riesgo quirúrgico. El desarrollo de la técnica ha permitido que en gran parte de los casos se pueda realizar un abordaje menos complejo (abordaje minimalista), con el objetivo de reducir la repercusión hemodinámica del procedimiento, complicaciones iatrogénicas, costos y duración de la internación y del procedimiento. Se presenta el primer caso reportado en Uruguay de implante percutáneo transfemoral de válvula aórtica mediante abordaje minimalista.


Summary: Aortic stenosis frequently affects the elderly population with high prevalence of comorbidities that increase surgical risk. Transcatheter aortic valve replacement has demonstrated its usefulness in patients with moderate to very high surgical risk. The development of this technique allows that in many cases, a less complex approach can be performed (minimalist approach), with the objective of decreasing hemodynamic repercussion, iatrogenic complications, costs, hospitalization and intervention times. This is the first case of minimalist approach in transfemoral transcatheter aortic valve replacement reported in Uruguay.


Resumo: A estenose aórtica compromete frequentemente a população idosa a qual possui maior prevalência de comorbidades que elevam o risco cirurgico. O implante percutâneo da valva aórtica mostrou sua utilidade em pacientes com risco cirurgico intermedio a muito alto. O desenvolvimento da técnica permitiu em grande número de casos, uma abordagem menos complexa (nomeado abordagem minimalista), com o objetivo de reduzir a repercussão hemodinâmica do procedimento, as complicações iatrogênicas, os custos e a duração da internação e do procedimento. Apresentamos o primeiro caso relatado no Uruguai de implante valvar aórtico percutâneo pela via transfemoral utilizando uma abordagem minimalista.

8.
Medisan ; 21(4)abr. 2017. tab
Article in Spanish | LILACS | ID: biblio-841688

ABSTRACT

Se llevó a cabo un estudio observacional, descriptivo y transversal de 51 pacientes portadores de prótesis valvulares, ingresados en el Cardiocentro del Hospital Provincial Docente Clinicoquirúrgico Saturnino Lora Torres de Santiago de Cuba por presentar trombosis valvular o episodios hemorrágicos, desde enero del 2012 hasta diciembre del 2014, a fin de estimar las variaciones en los valores de la Razón Normalizada Internacional y su asociación con estos eventos. Se aplicó la prueba de Ji al cuadrado. Preponderaron los afectados con trombosis valvular (60,4 por ciento) y Razón Normalizada Internacional menor de 2,5; mientras que esta última en las hemorragias fue superior a 3,5. Aquellos con más de un factor de riesgo asociado presentaron mayor cantidad de episodios trombóticos; eventos que tuvieron menor incidencia cuando se integraron warfarina y aspirina al tratamiento


An observational, descriptive and cross-sectional study of 51 patients with valve prosthesis was carried out. They were admitted to the Cardiology Center of Saturnino Lora Torres Teaching Clinical Surgical Provincial Hospital due to valve thrombosis or bleeding episodes, from January, 2012 to December, 2014, with the purpose of estimating the variations in the International Standard Ratio values and their association with these events. The chi-square test was carried out. Those patients affected with valve thrombosis (60.4 percent) and International Standard Ratio under 2.5 were predominant; while the latter in bleedings was over 3.5. The patients with more than one associated risk factor presented higher quantity of thrombosis episodes; events that had less incidence when warfarin and aspirin were included in the treatment


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged , Heart Valve Prosthesis , Heart Valve Diseases/complications , Coronary Thrombosis , Odds Ratio , Epidemiology, Descriptive , Cross-Sectional Studies , Observational Study , Anticoagulants
9.
Medisan ; 19(7)jul.-jul. 2015. ilus, tab
Article in Spanish | LILACS, CUMED | ID: lil-752954

ABSTRACT

Se realizó un estudio descriptivo y transversal de 500 pacientes portadores de prótesis valvulares, quienes acudieron a la consulta externa del Servicio de Cirugía Cardiovascular del Hospital Provincial Docente Clinicoquirúrgico "Saturnino Lora Torres" de Santiago de Cuba, durante el 2014, con vistas a evaluar el nivel de sus conocimientos sobre anticoagulación con warfarina sódica. En la casuística primaron el sexo masculino (54,8 %), el grupo etario de 45-64 años (38,8 %) y los pertenecientes a las provincias de Santiago de Cuba y Holguín (43,8 y 34,8 %, respectivamente). Entre las características más notables figuraron: nivel de escolaridad hasta noveno grado (65,0 %), así como los afectados con prótesis mitrales y aórticas casi en su totalidad. Aunque 40,2 % de los integrantes de la serie tenían más de 4 años de operados no conocían las diferentes interacciones alimentarias, farmacológicas y criterios de control del tiempo de protrombina en la terapéutica del anticoagulante oral.


A descriptive and cross-sectional study of 500 patients carriers of valve prosthesis who went to the outpatient department of the Cardiovascular Surgery Service from "Saturnino Lora Torres" Teaching Clinical Surgical Provincial Hospital from Santiago de Cuba was carried out during 2014 with the aim of evaluating their knowledge level on anticoagulation with sodium warfarin. The male sex (54.8 %), the age group 45-64 years (38.8 %) and those belonging to Santiago de Cuba and Holguín provinces (43.8 and 34.8 %, respectively) prevailed in the case material. Among the most remarkable characteristics there were: school level up to ninth grade (65.0 %), as well as those affected with mitral and aortic prosthesis almost in their totality. Although 40.2 % of the members of the series had more than 4 years of their surgical treatment, they didn't know the different alimentary, pharmacological interactions and time control criteria for prothrombine in the therapy of the oral anticoagulant.


Subject(s)
Heart Valve Prosthesis , Anticoagulants , Thoracic Surgery , Warfarin , Secondary Care
10.
Rev. mex. cardiol ; 25(3): 158-162, jun.-sep. 2014. ilus, tab
Article in Spanish | LILACS-Express | LILACS | ID: lil-732049

ABSTRACT

Objetivo: Determinar la metodología de evaluación ecocardiográfica empleada en el Instituto Nacional de Cardiología (hospital de tercer nivel) en pacientes operados de cambio valvular aórtico. Método: Se incluyeron a todos los pacientes consecutivos mayores de 18 años con estenosis aórtica que fueron llevados a cirugía de cambio valvular aórtico en el Instituto Nacional de Cardiología "Ignacio Chávez", durante el periodo de enero del 2011 a junio del 2012. Se determinó la fecha de cirugía, tipo de prótesis y el número y fecha de ecocardiogramas realizados después del evento quirúrgico. Resultados: Se encontró que en el 81% de los pacientes el primer ecocardiograma postquirúrgico se realizó durante su internamiento. Esta primera evaluación fue realizada dentro de las primeras 24 a 48 horas a 42 pacientes (51.8%); entre los 3 y los 7 días a 27 pacientes (33.3%); entre los 8 y los 14 días a 7 pacientes (8.6%) y posterior a los 14 días a 5 pacientes (6.1%). A 19 pacientes no se les realizó ecocardiograma. Conclusiones: En el Instituto Nacional de Cardiología "Ignacio Chávez", se realiza una evaluación y seguimiento ecocardiográfico de los pacientes operados de cambio valvular aórtico distinto a las recomendaciones internacionales.


Objective: To determine the methodology for the echocardiographic evaluation of patients with aortic valve replacement at the Instituto Nacional de Cardiología. Method: We included all consecutive patients, 18 years old or more with aortic valve replacement secondary to aortic stenosis at the Instituto Nacional de Cardiología "Ignacio Chávez", between January 2011 and June 2012. We described the date of the surgery, type of prosthetic valve and the number and date of the echocardiograms after the valve replacement. Results: Between January 2011 and June 2012, 100 patients underwent aortic valve replacement. In 81% the first echocardiogram was made during hospitalization. The first evaluation was made within the first 24-48 hours in 42 patients (51.8%), between the 3rd and 7th day in 27 patients (33.3%), between the 8th and the 14th day in 7 patients (8.6%) and after 14 days in 5 patients (6.1%). No echocardiogram was made in 19 patients. Conclusions: At the Instituto Nacional de Cardiología "Ignacio Chávez" we made an echocardiographic evaluation and follow up different from the international recommendations for patients with valve replacement.

11.
Rev. colomb. cardiol ; 21(1): 60-67, ene.-feb. 2014. ilus, tab
Article in Spanish | LILACS, COLNAL | ID: lil-709013

ABSTRACT

En niños con insuficiencia o estenosis valvular significativa, la intervención de la válvula, ya sea valvuloplastia o reemplazo valvular, suele ser inevitable. El seguimiento de estos pacientes puede ser complejo; los síntomas iniciales de disfunción valvular protésica son inespecíficos y en ocasiones es difícil diferenciar entre los efectos de la disfunción valvular, las patologías no cardíacas, la disfunción ventricular y la hipertensión pulmonar. Aunque el examen físico puede alertar al clínico acerca de alteraciones, se requieren otros métodos diagnósticos para evaluar la función de la prótesis. La ecocardiografía Doppler es el método de elección no invasivo para estudiar la función valvular y pese a que muchas de las mediciones y parámetros de normalidad y anormalidad son extrapolados de estudios en adultos, se han tratado de definir estándares en pacientes pediátricos. Este documento ofrece una revisión acerca de las técnicas usadas en el estudio de las válvulas protésicas con base en literatura científica, consensos internacionales y opiniones de expertos.


In children with significant valvular insufficiency or stenosis, valve surgery, either valvuloplasty or valve replacement is usually inevitable. The monitoring of these patients can be complex, the initial symptoms of prosthetic valve dysfunction are nonspecific and sometimes difficult to differentiate between the effects of valvular dysfunction, non-cardiac pathologies, ventricular dysfunction and pulmonary hypertension. Although physical examination may alert the clinician about alterations, other diagnostic methods to assess the function of the prosthesis is required. Doppler echocardiography is the noninvasive method of choice to study valvular function and although many of the measurements and parameters of normality and abnormality are extrapolated from adult studies have been attempted to define standards in pediatric patients. This document provides an overview about the techniques used in the study of prosthetic valves based on scientific literature, international consensus and expert opinion.


Subject(s)
Echocardiography , Heart Valve Prosthesis , Cardiology , Echocardiography, Doppler
12.
Rev. cuba. med ; 52(2): 99-108, abr.-jun. 2013.
Article in Spanish | LILACS | ID: lil-678121

ABSTRACT

Introducción: se realizó un estudio de intervención con todos los pacientes sometidos a cirugía de sustitución valvular protésica aórtica que acudieron a rehabilitarse en el Departamento de Rehabilitación Cardiovascular del Hospital Hermanos Ameijeiras durante el año 2011. Objetivo: caracterizar el comportamiento de los factores de riesgo coronario. Métodos: la muestra estuvo conformada por 16 pacientes. Se halló que el rango etario más frecuente fue el de 55-64 años, el sexo masculino y el color de piel blanca. La prótesis valvular de tipo mecánica fue implantada en todos los pacientes. Se observó mejoría en la capacidad funcional posterior a la rehabilitación cardíaca, se logró reducir el sedentarismo, la obesidad y el hábito de fumar, así como el incremento del número de pacientes hipertensos y diabéticos controlados. No ocurrieron complicaciones en la mayoría de los pacientes durante la rehabilitación. Conclusión: mediante la rehabilitación cardíaca se logró disminuir los FRC asociado a un bajo índice de complicaciones


Background: an intervention study was performed in all patients that were submitted to aortic prosthetic valve replacement surgery that began rehabilitation at the Cardiac Rehabilitation Unit Department of Hermanos Ameijeiras Hospital during the year 2011. Objective: to characterize the behavior of coronary risk factors. Methods: the sample was comprised of 16 patients. It was observed that the most frequent age rank was 55-64 years and most of the patients were male and white. All patients received mechanical aortic valve replacement. An improvement in the functional capacity in patients after cardiac rehabilitation was observed. Sedentary life, obesity and smoking habit were cut down and there was an increase in the number of controlled diabetic and hypertensive patients. Complications did not occur in the majority of patients during rehabilitation. Conclusions: cardiac rehabilitation diminished FRC associated to a low rate of complications


Subject(s)
Humans , Male , Middle Aged , Impacts of Polution on Health/prevention & control , Blood Vessel Prosthesis Implantation/methods , Blood Vessel Prosthesis Implantation/rehabilitation
13.
Rev. argent. cardiol ; 81(1): 70-73, feb. 2013. ilus, tab
Article in Spanish | LILACS | ID: lil-694839

ABSTRACT

Existen varios factores predisponentes para el desarrollo de endocarditis infecciosa; entre ellos se destacan el antecedente de haber padecido endocarditis infecciosa y el recambio valvular con válvula protésica. La endocarditis infecciosa de válvula protésica producida por Salmonella es una entidad de muy baja incidencia. En esta presentación se describe el caso de una paciente con antecedente de doble recambio valvular, mitral y aórtico, que ingresó con un cuadro de sepsis grave. Se llegó al diagnóstico etiológico de endocarditis infecciosa por Salmonella enteritidis a través de hemocultivos. La paciente tuvo una evolución fulminante y falleció antes de las 24 horas.


There are several predisposing factors for the development of infectious endocarditis, among them, the history of infectious endocarditis and prosthetic valve replacement. Infectious endocarditis in prosthetic valve caused by Salmonella is an unusual entity. We report the case of a female patient with a history of double-valve mitral and aortic replacement, who was admitted due to severe sepsis. The etiological diagnosis of infectious endocarditis by Salmonella enteritidis was reached through blood cultures. The clinical course was fulminant and she died within the first 24 hours.

14.
Rev. argent. cardiol ; 79(6): 537-540, dic. 2011. ilus
Article in Spanish | LILACS | ID: lil-639688

ABSTRACT

El desarrollo de fuga paravalvular (FPV) luego del reemplazo valvular mitral es un fenómeno poco frecuente pero de gran repercusión sintomática. Debido a la elevada morbimortalidad de su abordaje quirúrgico se han intentado varias técnicas percutáneas con una tasa éxito que varía entre el 60% y el 90%. En esta presentación se describe el caso de una paciente joven, con múltiples cirugías valvulares mitrales previas, sintomática por disnea limitante y anemia hemolítica. Con el uso de imágenes ecocardiográficas tridimensionales, se realizó la oclusión de la FPV con un dispositivo Amplatzer III, diseñado específicamente para dicha indicación. Luego de un seguimiento de 3 meses, la FPV permanece totalmente excluida y la paciente se encuentra asintomática.


The development of mitral paravalvular leak (PVL) after mitral valve replacement is an uncommon complication with severe symptoms. The surgical repair of this condition has high morbidity and mortality; for this reason, several percutaneous techniques have been attempted with success rates between 60% and 90%. We describe the case of a young female patient with multiple mitral valve surgeries, who presented limiting dyspnea and hemolytic anemia. The PVL was closed using a specially designed Amplatzer III device under three-dimensional echocardiography. After 3 months of follow-up, the PVL remains completely excluded and the patient is asymptomatic.

15.
Rev. argent. cardiol ; 78(6): 476-484, nov.-dic. 2010. graf, tab
Article in Spanish | LILACS | ID: lil-634214

ABSTRACT

Introducción Las indicaciones y los beneficios del reemplazo valvular aórtico han sido claramente establecidos, aun para poblaciones añosas, de aumentada comorbilidad. Aun así, la manipulación de ateromas aórticos, el uso de circulación extracorpórea y de clampeo aórtico, el paro cardíaco y la descalcificación ligadas a esta técnica y sus eventuales consecuencias generan dudas acerca de su indicación en este grupo de pacientes. Objetivos Comunicar la morbimortalidad del procedimiento en octogenarios y validar la utilidad de los puntajes de predicción de riesgo utilizados más frecuentemente. Material y métodos Se estudiaron 87 pacientes octogenarios sometidos a reemplazo aórtico aislado; se analizaron variables preoperatorias, intraoperatorias y posoperatorias y se aplicó el Euroscore; para facilitar el subanálisis del Euroscore logístico, la población se dividió en tres grupos: riesgo bajo, moderado y alto. Se utilizó técnica quirúrgica convencional. Para el seguimiento, se analizó la historia clínica y/o se realizó encuesta telefónica. Resultados La mediana de edad fue de 83 ± 2,5 años, con un rango de 80 a 89 años. El 60% de la población en estudio era de sexo femenino. La indicación quirúrgica fue estenosis 92%, endocarditis activa 4,6% y enfermedad valvular 3,4%. Antecedentes: hipertensión 71%, tabaquismo 31%, dislipidemia 39%, diabetes 11,5%, EPOC 10%, IRC-diálisis 2,3%, ACV 11,5%, IAM previo 8%, fibrilación auricular 16%, reoperación 15%. Cuadro clínico: asintomático 3,45%, angina crónica estable 10,3%, angina inestable 11%, ICC 13,8%, disnea CF III-IV 60%. Disfunción ventricular izquierda moderada-grave 18,3%. Riesgo por Euroscore logístico 12,4% ± 15%. El tiempo operatorio promedio fue de 200 ± 61,7 min, el de CEC de 86 ± 32,5 min y el de clampeo aórtico de 65 ± 18,2 min. Complicaciones: sangrado médico 17,2%, reoperación sangrado 5,7%, bajo gasto cardíaco 13,8%, inotrópicos > 48 horas 32,1%, balón de contrapulsación 1,2%, fibrilación auricular 32,2%, marcapasos transitorio 20,7%, marcapasos definitivo 5,7%, complicación pulmonar 3,4%, ACV con secuela 3,4%, IRA oligoanúrica 27,6%, diálisis 5,7%, infección esternal 1,2%, días UTI 3 ± 5,2, días estadía 8 ± 9,6, mortalidad global 10,34%, mortalidad prioridad electiva 9,5%, mortalidad no electiva 12,5%. Estadía en UCI 3 ± 5,2 días y total 8 ± 9,6 días. Divididos por grupos, la mortalidad comunicada fue del 7,14%, 15,38% y 5% para riesgo bajo, mediano y alto, respectivamente. Se identificó como predictor de mortalidad a los 30 días el bajo gasto cardíaco posoperatorio (OR 7, p = 0,011). Se siguieron 71 pacientes (91%), mediana 1.203 días (51 a 3.927). Independientemente del puntaje preoperatorio, la sobrevida fue del 98,6% al primer año, del 87,65% a los 3 años, del 77,3% a los 5 años y del 48,6% a los 7 años. El 72% refirió mejoría de la calidad de vida, el 21% sin cambios y el 7%, empeoramiento. No se hallaron predictores al seguimiento. Conclusiones La cirugía de reemplazo valvular resulta un procedimiento seguro y duradero, de comprobado beneficio funcional y con sobrevida a largo plazo homologable a la población general. La utilización de puntajes de riesgo preoperatorio debe ser revisada, por la sobrestimación del riesgo operatorio demostrada.


Background The indications and benefits of aortic valve replacement have been clearly established, even for elderly populations with high prevalence of comorbidities. However, concern arises about the indication of aortic valve replacement in this population due to manipulation of aortic atheromas, use of cardiopulmonary bypass and cross clamping of the aorta, cardiac arrest and decalcification that are related with this procedure, and their eventual consequences. Objectives To report morbidity and mortality of the procedure in octogenarians and validate the usefulness of the risk scores most frequently used. Material and Methods A total of 87 octogenarian patients undergoing isolated aortic valve replacement were included; preoperative, operative and postoperative variables were analyzed, and EuroSCORE was estimated; the population was divided into three groups of risk (low, moderate and high) for logistic EuroSCORE analysis. A conventional surgical technique was used. The medical records were analyzed and/or telephone contact was used for follow-up. Results Median age was 83±2.5 years (range: 80 to 89). Sixty percent of the population were women. Indications for aortic valve replacement were aortic stenosis 92%, active endocarditis 4.6% and combined aortic valve disease 3.4%. History: hypertension 71%, smoking habits 31%, dyslipemia 39%, diabetes 11.5%, COPD 10%, CKF-dialysis 2.3%, stroke 11.5%, previous MI 8%, atrial fibrillation 16%, reoperation 15%. Clinical presentation: absence of symptoms 3.45%, chronic stable angina 10.3%, unstable angina 11%, CHF 13.8%, dyspnea FC III-IV 60%, moderate to severe left ventricular dysfunction 18.3%, logistic EuroSCORE risk 12.4%±15%. Average operative time was 200±61.7 min, CBP time 86±32.5 min and aortic-cross clamp time 65±18.2 min. Complications: medical bleeding 17.2%, reoperation due to bleeding 5.7%, low cardiac output syndrome 13.8%, requirement of inotropic agents > 48 hours 32.1%, intraaortic balloon pump 1.2%, atrial fibrillation 32.2%, transient pacemaker 20.7%, permanent pacemaker 5.7%, pulmonary complications 3.4%, stroke with consequences 3.4%, oliguric/anuric AKF 27.6%, dialysis 5.7%, sternum infection 1.2%, ICU stay 3±5.2 days, hospital stay 8±9.6 days, overall mortality 10.34%, elective surgery mortality 9.5%, non elective surgery mortality 12.5%. Mortality in low, moderate and high risk groups was l7.14%, 15.38% and 5%, respectively. Postoperative low cardiac output syndrome was identified as a predictor of mortality at 30 days (OR 7, p=0.011). Seventy one patients (91%) completed median follow-up of 1023 days (51 to 3927). Survival rate was 98.6% at 1 year, 87.65% at 3 years, 77.3% at 5 years and 48.6% at 7 years, regardless of the preoperative score. Quality of life improved in 72% of patients, while 21% did not report any changes and was worse in 7%. We did not find predictors during follow-up. Conclusions Aortic valve replacement is a safe, long-lasting procedure that confers proved functional benefit and a long-tem survival that is comparable to that of the general population. The use of preoperative scores should undergo revision as they overestimate the operative risk.

16.
Rev. colomb. cardiol ; 16(6): 256-260, nov.-dic. 2009.
Article in Spanish | LILACS | ID: lil-552609

ABSTRACT

Se presenta el caso de un hombre de setenta y un años de edad quien presenta en forma súbita síntomas y signos isquémicos cerebrales. Tiene antecedente de fibrilación auricular crónica, prótesis valvular en posición aórtica y mitral, insuficiencia cardiaca y complicaciones hemorrágicas relacionadas con la anticoagulación. Como parte del estudio se realizó ecocardiograma transesofágico que demostró trombo mural gigante en la aurícula izquierda, el cual desapareció luego de nueve meses de tratamiento anticoagulante.


The case of a 71 years old male that suddenly presents ischemic brain signs and symptoms is presented. He had a previous history of chronic atrial fibrillation, mitral and aortic valve protheses, heart failure and bleeding related to anticoagulation. A transesophageal echocardiogram was performed as part of the assessment, showing a gigantic left atrial mural thrombus that disappeared after 9 months of anticoagulation therapy.


Subject(s)
Heart Valve Prosthesis
17.
Rev. argent. cardiol ; 77(3): 203-207, mayo-jun. 2009. ilus
Article in Spanish | LILACS | ID: lil-634084

ABSTRACT

Una proporción importante de pacientes con estenosis aórtica (EAo) grave poseen comorbilidades que incrementan el riesgo de la cirugía de reemplazo valvular aórtico. El implante percutáneo de válvula protésica surge como una alternativa en este grupo de pacientes. Se comunican dos casos de pacientes de edad avanzada portadores de EAo grave a los que se les realizó con éxito el implante percutáneo de una prótesis valvular aórtica CoreValve y se describen los criterios para la selección de pacientes y la técnica de implante percutáneo.


A significant proportion of patients with severe aortic stenosis (AS) have comorbidities that increase the risk of surgical aortic valve replacement. Percutaneous implantation of an aortic valve prosthesis emerges as an alternative in this group of patients. We report two cases of elderly patients with severe aortic stenosis that underwent successful percutaneous implantation of CoreValve aortic valve prostheses; in addition, criteria for patient selection and the technique of the procedure are described.

18.
Rev. argent. cardiol ; 76(4): 266-271, jul.-ago. 2008. graf, tab
Article in Spanish | LILACS | ID: lil-634012

ABSTRACT

Introducción El reemplazo valvular aórtico es el procedimiento convencional en la enfermedad valvular y el modelo protésico que se ha de implantar resulta una decisión compleja. Nuevos modelos biológicos, cuyo especial tratamiento reduce el deterioro estructural alejado, han alentado su uso, aun en poblaciones jóvenes. Objetivo Evaluar la sobrevida alejada del recambio valvular aórtico biológico, la calidad de vida, las tasas de reinternación y reintervención, así como identificar predictores para tales eventos. Material y métodos Se analizó una población sometida a cirugía aórtica aislada o combinada con revascularización, con modelos biológicos, entre junio de 1996 y diciembre de 2005. Excluidos los fallecidos a los 30 días, se analizaron 256 pacientes, con un seguimiento del 94,2% a 1.158 días. Resultados La sobrevida global fue del 94,8%, 88,6%, 85% y 82,4% a 1, 3, 5 y 7 años; sobrevida libre la mortalidad cardíaca, fue del 97,2%, 94,6%, 91,2% y 89,4%, respectivamente. La sobrevida libre de reinternación fue del 86%, 75,7%, 70,6% y 65,9% para igual período. La sobrevida libre de reintervención fue del 97,4%, 95,2%, 92,1% y 92,1% a 1, 3, 5 y 7 años. Fueron predictores para mortalidad el ritmo no sinusal (OR 3,4; p = 0,012) y para reinternación la enfermedad carotídea (OR 7,6; p = 0,002), la EPOC (OR 7; p = 0,004) y el sexo masculino (OR 2,18; p = 0,039). La baja incidencia de reintervenciones no permitieron identificar predictores. Conclusiones La sobrevida alejada es aceptable para el grupo etario y el ritmo no sinusal es el único predictor de mortalidad identificado. La tasa de reinternación al primer año es elevada y el sexo masculino, la estenosis carotídea y los antecedentes respiratorios y cerebrovasculares, así como la prioridad no electiva, son sus predictores. La tasa de reintervención al seguimiento es baja y alienta la utilización de este tipo de prótesis.


Background Aortic valve replacement is the conventional procedure in aortic valve disease; nevertheless, choosing the most suitable model of prosthesis is a complex decision. The use of novel biological models specially treated to reduce long-term structural deterioration has been encouraged, even in young populations. Objective To assess long-term survival of biological valve replacement, quality of life, rates of readmission and reintervention and to identify predictors of those events. We analyzed a population of patients who had undergone aortic valve replacement with bioprosthesis, alone or combined with revasculatization, between June 1996 and December 2005. Excluding those who were dead within 30 days after surgery, 256 patients were included, and 94.2% completed follow-up at 1158 days. Results Overall survival was 94.8%, 88.6%, 85% and 82.4% at 1, 3, 5 and 7 years, respectively; and 97.2%, 94.6%, 91.2% and 89.4%, respectively, excluding cardiovascular deaths. Freedom from readmission was 86%, 75.7%, 70.6% and 65.9% for the same period. Freedom from reintervention CABG or new valve replacement was 97.4%, 95.2%, 92.1% and 92.1% at 1, 3, 5 and 7 years. Non-sinus rhythm was identified as a predictor for mortality (OR 3.4; p = 0.012) and carotid disease (OR 7.6; p = 0.002), COPD (OR 7; p = 0,004 and male gender (OR 2.18; p = 0.039) were recognized as predictors for readmission. Predictors for reintervention were not identified due to the low incidence of this endpoint. Conclusions Long-term survival is acceptable for the age group and nonsinus rhythm, the only predictor of mortality identified. Readmission rate at one year is high and male gender, carotid stenosis, history of respiratory and cerebrovascular diseases, and non-elective surgery are predictors for this outcome. Reintervention rate during follow-up is low, encouraging the indication of this type of prosthesis.

19.
Rev. argent. cardiol ; 76(3): 187-192, mayo-jun. 2008. ilus, graf
Article in Spanish | LILACS | ID: lil-633999

ABSTRACT

Introducción La patología de la válvula aórtica es una de las causas más frecuentes de reemplazo valvular en nuestro medio. La falta de información actualizada sobre la evolución alejada de pacientes que recibieron prótesis mecánicas en posición aórtica motivó la realización del presente estudio. Objetivo Conocer la mortalidad, la morbilidad (complicaciones mayores) y los resultados funcionales (mejoría clínica) durante el seguimiento de pacientes portadores de una válvula mecánica en posición aórtica. Material y métodos Se seleccionaron 95 pacientes sometidos a reemplazo valvular aórtico con prótesis mecánicas. Todos los pacientes fueron operados entre enero de 1999 y diciembre de 2006. La media de seguimiento fue de 4,5 ± 2,3 años, percentiles 25-75: 2,5-6,3 años. El seguimiento total fue de 427,5 pacientes/año. Resultados La media de edad fue de 64,5 ± 12,3 años y el 61,1% de los pacientes eran de sexo masculino. Sesenta pacientes (63%) estaban en clase funcional (CF) III-IV antes de la cirugía. En el seguimiento, 67 pacientes (70,5%) se encuentran en CF I y 28 (29,5%) en CF II. No se observaron pacientes en CF III ni IV. La media del índice área valvular efectiva / área de superficie corporal fue de 1,06 cm²/m². La supervivencia actuarial (Kaplan-Meier) fue del 95% (IC 95% 88-98%) a un año y del 89% a los 5 años (IC 95% 76-95%). La mortalidad relacionada se registró en 9 pacientes (9,5%). La incidencia de tromboembolia fue del 0,2% paciente-año, la de hemorragia del 2,3% paciente- año y la de endocarditis del 0,7% paciente-año. La tasa de reoperación fue del 0,4% paciente-año. Conclusiones Los resultados obtenidos fueron similares a los comunicados en series internacionales en términos de supervivencia y complicaciones mayores. La frecuencia de eventos adversos observados a mediano plazo, como en todo el mundo, aún permanece elevada.


Background Aortic valve disease is one of the most frequent causes of valve replacement in our environment. This study was performed based on the lack of information related to late outcomes in patients submitted to aortic valve replacement with mechanical prosthesis. Objective To assess the mortality, morbidity (major complications) and functional outcomes (clinical improvement) during the follow- up of patients with mechanical prosthesis placed in the aortic position. Material and Methods Ninety five patients submitted to aortic valve replacement with mechanical prosthesis were selected. Surgeries were performed between January 1999 and December 2006. Mean follow-up was 4±2.3 years; percentiles 25-75: 2.5-6.3 years. Total follow-up was 427.5 patients/year. Results Mean age was 64.5±12.3 years, 61.1% were men. Sixty patients (63%) were in functional class (FC) III-IV prior to surgery. During follow-up, 67 patients (70.5%) were en FC I and 28 (29.5%) in FC II. No patients presented FC III or IV. Mean effective valve area/body surface area was 1.06 cm²/m². Actuarial survival (Kaplan-Meier) was 95% (95% CI 88-98%) at one year and 89% at 5 years (95% CI 76-95%). Nine deaths (9.5%) were related to this condition. The incidence of complications was as follows: thromboembolism 0.2% patient/ year, bleeding 2.3% patient/year, and endocarditis 0.7% patient/ year. Re-operation rate was 0.4% patient/year. Conclusions These results were similar to those reported in international series in terms of survival and major complications. The number of adverse events observed at mid-term is still high, as it is all around the world.

20.
Rev. argent. cardiol ; 76(2): 106-111, mar.-abr. 2008. ilus, tab
Article in Spanish | LILACS | ID: lil-633985

ABSTRACT

Introducción El mismatch paciente-prótesis (MPP) aórtica se asocia con peor evolución posoperatoria. La utilización del área del orificio aórtico efectivo (AOE) para cada tipo de prótesis, indexado por la superficie corporal (SC) en el momento quirúrgico, puede permitir la elección de un tamaño de prótesis adecuado para cada paciente y así evitar el MPP. Objetivo Comparar la estimación de MPP por las AOE tabuladas con la diagnosticada en el posoperatorio alejado por eco-Doppler. Material y métodos Se analizaron retrospectivamente 57 pacientes, 43 hombres, con prótesis aórtica, operados más de 6 meses antes del estudio. Se calculó la SC del parte quirúrgico y el AOE indexada tabulada, el AOE posquirúrgica con eco-Doppler transtorácico por la ecuación de continuidad y se comparó el MPP prequirúrgico y posquirúrgico. Se consideró MPP aórtico un AOE indexada < 0,75 cm²/m². Resultados Se observó una prevalencia de MPP preoperatorio del 29,8% y posoperatorio del 54,4% (p = 0,029), con el 31% de MMP grave. La prevalencia de sobrepeso en la muestra estudiada fue del 80%. Conclusiones En este grupo de pacientes con alta prevalencia de sobrepeso, la estimación del AOE preoperatoria indexada por SC de cada tipo de prótesis para predecir el MPP posoperatorio mostró diferencias significativas entre el diagnóstico del MPP estimado en el preoperatorio y el calculado por eco-Doppler en el posoperatorio. En futuros estudios es necesaria la inclusión de un grupo poblacional mayor, así como la revisión del método de cálculo del área valvular (p. ej., del tracto de salida del ventrículo izquierdo).


Background Patient-aortic valve prosthesis mismatch (PPM) is associated with poor postoperative outcomes. Determination of aortic effective orifice area (EOA) indexed for body surface area (BSA) is useful to select suitable type and size of heart valve prosthesis in order to prevent patient-prosthesis mismatch. Objective The objective of this study was to compare the PPM estimated by indexed EOA with PPM determined by echo-Doppler at late follow-up. Material and Methods Fifty seven patients (43 men) who had undergone an aortic valve replacement in the previous 6 months were retrospectively assessed. After calculating BSA from the surgical report, indexed EOA, postoperative EOA (determined by the continuity equation with transthoracic echo-Doppler), preoperative and postoperative PPM were compared. An indexed EOA < 0.75 cm²/m² was considered aortic PPM. Results The prevalence of preoperative and postoperative PPM was 29.8% and 54.4%, respectively (p=0.029); 31% of MMP was severe. The prevalence of overweight in this sample was 80%. Conclusions In this group of patients with a high prevalence of overweight, the estimation of preoperative EOA indexed for BSA in order to predict postoperative PPM according to the type of prosthesis, showed significantly differences between preoperative PPM and postoperative PPM calculated by echo-Doppler. Further studies should not only include a larger sample, but should also check the method used for calculating valvular area (for example, in the left ventricular outflow tract).

SELECTION OF CITATIONS
SEARCH DETAIL