Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Rev. Fac. Odontol. (B.Aires) ; 38(88): 65-70, 2023. ilus
Article in Spanish | LILACS | ID: biblio-1552378

ABSTRACT

Las pulpectomías en molares primarios están indica-das en casos de diagnóstico de pulpitis irreversible o necrosis y reabsorción radicular mínima o nula. Son tratamientos laboriosos y extensos, que sólo pueden ser llevados a cabo en pacientes colaboradores. En búsqueda de simplificar esta terapéutica y mejorar su eficacia, se propone la mecanización de la pre-paración de los conductos de molares primarios. Diversos autores aseguran que esta técnica opti-miza el tiempo clínico y mejora la calidad del trata-miento, obteniendo gran aceptación en la literatura actual. Se presenta la secuencia de procedimientos, resolución y controles de dos tratamientos de pul-pectomía con instrumentación mecanizada en mola-res primarios (AU)


Pulpectomies in primary molars are indicated in cases of irreversible pulpitis or necrosis with mini-mal or no root resorption. They are laborious and ex-tensive treatments, which only can be carried out in cooperative patients. In order to simplify this therapy and improve its effectiveness, the mechanization of root canal preparation is proposed. Several authors assume that this technique optimizes preparation time and improves the quality of treatment, obtaining great acceptance in the current literature. We report the sequence of procedures, resolution, and controls of two pulpectomies with mechanized instrumenta-tion in primary molars (AU)


Subject(s)
Humans , Male , Child , Tooth, Deciduous/injuries , Argentina , Pulpitis/therapy , Schools, Dental , Dental Care for Children/methods , Dental Instruments/trends
2.
Acta odontol. latinoam ; 34(1): 18-26, Apr. 2021. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1284930

ABSTRACT

ABSTRACT The aim of this study was to evaluate the possible association between the roughness of 5 brands of stainless steel endodontic files and their resistance to fracture due to cyclic fatigue. The study includedfive different brands of stainless steel endodontic files: SybroEndo Triple-Flex Files (Kerr, Glendora, USA), Ready Steel K-Flexofile (Dentsply Sirona, Ballaigues, Switzerland), Mani Flexile Files (Mani, Tochigi- Ken, Japan), FKG K-Files (FKG, La Chaux-de-Fonds, Switzerland) and Zipperer Flexicut Files (VDW, Munich, Germany). Twelve files per brand (total 60 files) were evaluated. File surface roughness over an area (Sa) was quantified using a focus variation microscope. Then the files were subject to a cyclical fatigue test to determine the number cycles to fracture due to fatigue and length of fractured fragment. Finally, fractographic analysis was performed using a scanning electron microscope. The electropolished Ready Steel K-Flexofile® files had the highest roughness according to Sa parameters, though they also had the highest resistance to fracture due to cyclic fatigue and the longest fractured fragment. Moderate positive correlation was found between fractured fragment length and roughness. The fractured surface showed characteristics of ductile fracture with cracks and plastic deformation. The electropolished stainless steel Ready Steel K-Flexofile® files werethe most resistant to fracture due to cyclic fatigue even though they had highest surface roughness.


RESUMEN El objetivo del presente estudio fue evaluar la posible asociación entre la rugosidad de 5 marcas de limas endodónticas de acero inoxidable y su resistencia a la fractura por fatiga cíclica. Se incluyeron cinco grupos diferentes de limas endo-dónticas de acero inoxidable: SybroEndo Triple-Flex Files (Kerr, Glendora, EE. UU.), Ready Steel K-Flexofile (Dentsply Sirona, Ballaigues, Suiza), Mani Flexile Files (Mani, Tochigi-Ken, Japón), FKG K-Files (FKG, La Chaux-de-Fonds, Suiza) y Zipperer Flexicut Files (VDW, Munich, Alemania); se evaluaron doce instrumentos por grupo para un total de 60 limas. Mediante un microscopio de variación focal se cuantificó la rugosidad superficial por área (Sa) de los instrumentos, posteriormente fueron sometidos a una prueba de fatiga cíclica donde se determinó el número de ciclos de fractura por fatiga y la longitud del fragmento fracturado. Finalmente, se realizó un análisis fractográfico mediante microscopía electrónica de barrido. Las limas Ready Steel K-Flexofile® con electropulido mostraron el mayor valor de rugosidad en los parámetros Sa; sin embargo, también tenían la mayor resistencia a la fractura por fatiga cíclica y la mayor longitud del fragmento fracturado del instrumento. Además, se encontró una correlación moderada positiva entre la longitud del fragmento fracturado y la rugosidad. La superficie fracturada mostró características de fractura dúctil con grietas y deformación plástica. Las limas Ready Steel K-Flexofile® fabricadas en acero inoxidable con electropulido, fueron más resistentes a la fractura por fatiga cíclica a pesar de tener la mayor rugosidad superficial.

3.
J. oral res. (Impresa) ; 10(1): 1-7, feb. 24, 2021. ilus, graf, tab
Article in English | LILACS | ID: biblio-1282565

ABSTRACT

Objective: The aim of this study was to assess the micro-push-out bond strength of a mineral-based root canal sealer, BioRoot RCS in canals prepared by K3XF rotary systems of two different tapers. Material and Methods: Eighty caries free maxillary central incisors were used in this study. The samples were allocated into 4 groups (n=20) according to the root canal sealer and taper of the rotary instruments. The samples were obturated using single cone obturation technique. From each root 1mm thick slices at coronal, middle and apical thirds were collected using hard tissue microtome under continuous water coolant. Push-out tests were done for these sections using a Universal testing machine (INSTRON 8801) at a crosshead speed of 1mm/min. One-way analysis of variance (ANOVA) was used to compare the bond strengths within groups and Tukey's multiple post hoc analysis was used for pair-wise comparison of bond strengths. Results: AH Plus exhibited higher micro-push-out bond strength than BioRootRCS though they did not differ significantly (p>0.05). Preparation of root canals with 6% taper rotary instruments showed higher bond strength than 4% though they did not differ significantly (p>0.05). Conclusion: There was no significant difference between micro-push-out bond strength values of BioRoot RCS and AH Plus. The bond strength values were high in 6% taper canals than 4% canals though the difference was not significant statistically.


Objetivo: El objetivo de este estudio fue evaluar la fuerza de unión por micro-expulsión de un sellador de conductos radiculares de base mineral, BioRoot RCS, en conductos preparados por sistemas rotativos K3XF con dos conos diferentes. Material y Métodos: En este estudio se utilizaron 80 incisivos centrales superiores libres de caries. Las muestras se distribuyeron en cuatro grupos (n = 20) de acuerdo al sellador del conducto radicular y al cono de los instrumentos rotativos. Las muestras se obturaron mediante la técnica de obturación de un solo cono. De cada raíz se recogieron rodajas de 1 mm de grosor en los tercios coronal, medio y apical utilizando un micrótomo de tejido duro con refrigeración continua por agua. Posteriormente, se realizó una prueba de expulsión para estas secciones utilizando una máquina de prueba universal (INSTRON 8801) a una velocidad del cabezal transversal de 1mm/min. Se utilizó el análisis de varianza unidireccional (ANOVA) para comparar las resistencias de la unión dentro de los grupos y el análisis post hoc multiple de Tukey se utilizó para la comparación por pares de las resistencias de la unión. Resultados: AH Plus exhibió una fuerza de unión de micro-expulsión más alta que BioRootRCS, aunque no difirieron significativamente (p>0,05). La preparación de los conductos radiculares con instrumentos rotativos ahusados al 6% mostró una fuerza de unión superior al 4%, aunque no difirieron significativamente (p>0,05). Conclusión: No hubo diferencias significativas entre los valores de fuerza de unión de micro-expulsión de BioRoot RCS y AH Plus. Los valores de la fuerza de unión fueron más altos en canales cónicos al 6% que en canales al 4%, aunque la diferencia no fue significativa estadísticamente.


Subject(s)
Humans , Root Canal Filling Materials , Root Canal Obturation/methods , Dentin-Bonding Agents , Flexural Strength , Resins, Synthetic , Analysis of Variance , Root Canal Preparation , Dental Pulp Cavity , Epoxy Resins/chemistry , Minerals
4.
Rev. cuba. estomatol ; 57(4): e3076, Oct.-Dec. 2020. tab
Article in Portuguese | LILACS, CUMED | ID: biblio-1144450

ABSTRACT

Resumo Introdução: Os pinos de fibra de vidro têm sido amplamente utilizados na reconstrução de elementos com perda excessiva de estrutura dentária. Objetivo: Avaliar a força de adesão de pinos de fibra de vidro após diferentes tratamentos radiculares em diferentes regiões (terço cervical, médio e apical) da dentina radicular. Métodos: Este é um estudo experimental in vitro. Quarenta dentes bovinos foram selecionados, preparados e distribuídos em quatro grupos de acordo com o tratamento de superfície utilizado: adesivo (1), agente quelante (2), ácido poliacrílico (3), não tratado (4). A cimentação dos pinos de fibra de vidro foi realizada com cimento resinosante autocondicionante. Após vinte dias, cada raiz foi cortada em três fatias (um milímetro de espessura) obtidas de três regiões. A resistência de união de cada seção foi determinada usando um teste de resistência da junta de encaixe. Os dados de resistência à flexão (MPa) foram analisados pelos testes ANOVA e Tukey (α = 0,05). Resultados: Na porção cervical, o grupo com tratamento prévio com ácido poliacrílico apresentou menor resistência ao cisalhamento por extrusão (push-out) do que o grupo sem tratamento prévio. O grupo com aplicação do sistema adesivo (28,89 ± 6,64 MPa) e o grupo com tratamento prévio com EDTA (21,58 ± 6,39 MPa) não apresentaram diferenças estatisticamente significantes em relação ao grupo sem tratamento prévio (grupo controle) no terço cervical. Nas porções média e apical, o grupo tratado com adesivo FGM Ambar apresentou maiores valores de ligação em comparação com os outros grupos. Conclusão: A aplicação prévia do adesivo aumentou a resistência de união nos terços médio e apical, em comparação aos outros grupos, podendo ter um efeito benéfico no sucesso clínico do tratamento restaurador(AU)


Resumen Introducción: Los postes de fibra de vidrio se han utilizado ampliamente en la reconstrucción de elementos con pérdida excesiva de estructura dental. Objetivo: Evaluar la fuerza de adhesión de postes de fibra de vidrio después de distintos tratamientos de raíz en diferentes regiones (tercios cervical, medio y apical) de dentina de raíz. Métodos: Estudio experimental in vitro. Se seleccionaron cuarenta dientes bovinos, se prepararon y se distribuyeron en cuatro grupos de acuerdo con el tratamiento de superficie utilizado: (1) adhesivo, (2) agente quelante, (3) ácido poliacrílico, (4) sin tratar. La cementación de los postes de fibra de vidrio se realizó con cemento de resina autograbante. Después de 20 días, cada raíz se seccionó transversalmente en tres rodajas (1 mm de espesor) obtenidas de tres regiones. La resistencia a la unión de cada sección se determinó usando una prueba de resistencia al corte por extrusión (push-out). Los datos de resistencia a la flexión (MPa) se analizaron mediante pruebas ANOVA y Tukey (α = 0,05). Resultados: En la porción cervical, el grupo con tratamiento previo de ácido poliacrílico mostró menor resistencia que el grupo sin tratamiento previo. El grupo con aplicación del sistema adhesivo (28,89 ± 6,64 MPa) y el grupo con tratamiento previo de EDTA (21,58 ± 6,39 MPa) no presentaron diferencias estadísticamente significativas en comparación con el grupo sin tratamiento previo (grupo control) en el tercio cervical. En las porciones media y apical, el grupo tratado con adhesivo Ambar® de FGM Dental Group mostró valores más altos de unión en comparación con los otros grupos. Conclusión: La aplicación previa del adhesivo aumentó la fuerza de unión en los tercios medio y apical, en comparación con los otros grupos, puede tener un efecto beneficioso sobre el éxito clínico del tratamiento restaurador(AU)


ABSTRACT Introduction: Glass fiber posts have been widely used for the reconstruction of elements with excessive dental structure loss. Objective: Evaluate the bond strength of glass fiber posts after various root dentin treatments in different regions (cervical, middle and apical thirds). Methods: An experimental in vitro study was conducted. Forty bovine teeth were selected, prepared and distributed into four groups according to the surface treatment used: (1) adhesive, (2) chelating agent, (3) polyacrylic acid, (4) not treated. The glass fiber posts were cemented with self-etch resin cement. After 20 days, each root was sectioned crosswise into three slices (1 mm in thickness) obtained from three regions. Bond strength was determined in each section with a push-out bond strength test. Flexural strength data (MPa) were analyzed with ANOVA and Tukey's tests. Results: In the cervical portion, the group with previous polyacrylic acid treatment displayed lower push-out strength than the group without previous treatment. The group with application of the adhesive system (28.89 ± 6.64 MPa) and the group with previous EDTA treatment (21.58 ± 6.39 MPa) did not exhibit any statistically significant differences in comparison with the group without previous treatment (control group) in the cervical third. In the middle and apical portions, the group treated with the adhesive Ambar® of FGM Dental Group showed higher bond values in comparison with the other groups. Conclusion: Previous adhesive application increased bond strength in the middle and apical thirds in comparison with the other groups, and may thus have a beneficial effect on the clinical success of the restorative treatment(AU)


Subject(s)
Humans , Root Resorption/therapy , Root Canal Preparation/methods
5.
J. oral res. (Impresa) ; 8(4): 325-330, nov. 5, 2019. graf
Article in English | LILACS | ID: biblio-1145355

ABSTRACT

The aim of the study was to quantify and compare apical debris extrusion in two systems of continuous and reciprocating rotary instrumentation with, and without, the use of a patency file. An experimental study was carried out in 120 mesial roots of lower first molars, which were randomized in the following 4 groups: Group A. Reciproc (VDW) R25 without a patency file, Group B Mtwo (VDW) without a patency file, Group C Reciproc (VDW) R25 with a patency file and Group D Mtwo with a patency file. Groups A, B and C presented statistically significant differences in comparison to group D, Mtwo with the use of a patency file (p<0.008 to 95% reliability). In conclusion, the greater amount of debris extruded through the apex occurred in roots instrumented with the reciprocating rotary system; this difference was statistically significant in relation to teeth treated with the Mtwo continuous rotary system with the use of a patency file.


El objetivo del estudio fue cuantificar y comparar la extrusión de residuos apicales en dos sistemas de instrumentación endodónticos rotativos, continuo y recíproco, con y sin el uso de una lima de pasaje apical. Se realizó un estudio experimental en 120 raíces mesiales de primeros molares inferiores, que se aleatorizaron en los siguientes 4 grupos: Grupo A. Reciproc (VDW) R25 sin lima de pasaje apical, Grupo B Mtwo (VDW) sin lima de pasaje apical, Grupo C Reciproc (VDW) R25 con lima de pasaje apical y Grupo D Mtwo con lima de pasaje apical. Los grupos A, B y C presentaron diferencias estadísticamente significativas encomparación con el grupo D, Mtwo con el uso de una lima de pasaje apical (p<0.008 a 95% de confiabilidad). En conclusión, la mayor cantidad de residuos extruidos a través del ápice ocurrió en raíces preparadas con el sistema rotativo recíproco; Esta diferencia fue estadísticamente significativa en relación a los dientes tratados con el sistema rotativo continuo Mtwo con el uso de una lima de pasaje apical.


Subject(s)
Humans , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Tooth Apex , Dental Instruments , Dental Pulp Cavity
6.
Mem. Inst. Invest. Cienc. Salud (Impr.) ; 15(2): 37-44, ago. 2017. ilus, tab
Article in Spanish | LILACS, BDNPAR | ID: biblio-869121

ABSTRACT

El objetivo de este trabajo fue evaluar cualitativamente las regularidades de los conductos radiculares preparados con diferentes técnicas: técnica escalonada de retroceso programado, técnica Oregón modificada por la F.O.B. y técnica rotatoria Protaper. Fueron utilizados 30 conductos radiculares ex vivo de dientes unirradiculares de un único conducto. Los conductos fueron instrumentados de la siguiente manera: G1 (n=10) con la técnica escalonada de retroceso programado, G2 (n=10) con Oregon modificada por la F.O.B y G3 (n=10) con técnica rotatoria Protaper. Una vez acabada la instrumentación el material de impresión fue inyectado en el conducto radicular; después del fraguado del material de impresión los dientes fueron descalcificados para obtener los moldes de los conductos que fueron fotografiados con aumento 20x con microscopio digital Dino Lite plus para analizar la uniformidad de la instrumentación por tercios por las tres diferentes técnicas, clasificándolas en: CBI (conducto bien instrumentado), CRI (conducto regularmente instrumentado), CPI (conducto pobremente instrumentado). Los resultados mostraron predominancia de CBI para la técnica Protaper en los tercios medio y apical; en el tercio cervical para las tres técnicas y el tercio apical para la técnica Oregon modificada, siendo los peores resultados para la técnica escalonada de retroceso programado y Oregon modificada en el tercio medio, tercio apical en la Escalonada de Retroceso Programado. No hubo diferencias estadísticamente significativas en la efectividad de las técnicas escalonada de retroceso programado, Oregon modificada y Protaper cuando fueron analizados cualitativamente los moldes de los tercios. Concluimos que las técnicas coronoapicales resultaron en una instrumentación más uniforme y de mejor calidad que la técnica escalonada.


The aim of this study was to evaluate qualitatively the regularities of root canalsprepared with different techniques: Step Back – Oregon modified by F.O.B andProtaper. Thirty ex vivo root canals of single-rooted teeth with a single root canal wereused. The canals were instrumented as follows: G1 (n=10) Step Back, G2 (n=10)Oregon modified by FOB and G3 (n=10) Protaper tecniques. Once instrumentation finished, impression material was injected into the root canal. After casting of theimpression material, the teeth were decalcified to obtain molds of the root canals thatwere photographed with 20x magnification using a digital Dino Lite plus microscope toanalyze the uniformity of the instrumentation on the thirds using the three techniquesthat were classified into: WIC (well instrumented canal), RIC (regularly instrumentedcanal) and PIC (poorly instrumented canal). The results shown predominance of WICfor the Protaper technique in the middle and apical thirds, in the apical third for thethree techniques and the apical third for the modified Oregon technique, being theworst results for the Step Back and Oregon techniques in the middle third, and for theStep Back in the apical third. There were no statistically significant differences in theeffectiveness of the Step Back, modified Oregon and Protaper techniques when thethirds molds were analyzed qualitatively. We conclude that the crown-apicaltechniques resulted in more uniform and better quality instrumentation than the StepBack technique.


Subject(s)
Humans , Dental Pulp Cavity , Oregon
7.
Acta odontol. latinoam ; 30(1): 33-38, 2017. ilus, tab, graf
Article in English | LILACS | ID: biblio-907405

ABSTRACT

The aim of this study was to analyze in vitro temperature changeson the outer surface of the dental root during mechanical fillingremoval procedures.Thirty recently extracted single­rooted lower premolars were cuttransversally at 16 mm from the apex in order to standardizesample length. Endodontic treatment was performed on them. Thefilling material was subsequently removed using Gates Glidden(G1, G2, G3); Peeso (P1, P2, P3) and PostecPlus FRC (FRC)reamers while temperatures were measured on the outer surfaceusing a digital device with thermocouple at 0, 2, 4, 6, 8, 10 and 15seconds. Temperatures were compared using repeated measuresANOVA followed by pairwise comparison with Tukey’s test.All reamers caused significant temperature variation betweendifferent times (p<0.05). Pairwise comparisons indicated thattemperature increased with time for all reamers (p<0.05).Significant differences in temperature were found betweendifferent reamers after 0, 2, 4, 6, 8, 10 and 15 seconds (p<0.05)...


El objetivo del presente trabajo fue estudiar los cambios térmicosin vitro en la superficie externa de la raíz del diente, generadosdurante los procedimientos de desobturación mecánica.Se utilizaron 30 premolares inferiores unirradiculares reciente ­mente extraídos, que fueron seccionados transversalmente a16 mm del ápice para estandardizar la longitud de lasmuestras. Se realizó luego su tratamiento endodóntico. Lasmediciones de temperatura fueron realizadas mediante undispositivo digital con termocupla, en la superficie externa adiferentes tiempos (t = 0, 2, 4, 6, 8, 10 y 15 segundos), durantela desobturación con fresas de Gates Glidden (G1, G2, G3);de Peeso (P1, P2, P3) y la correspondiente a PostecPlus FRC(FRC). Los registros de temperatura fueron comparadosmediante pruebas de ANOVA de medidas repetidas, seguidaspor comparaciones entre pares mediante la prueba de Tukey.Con todas las fresas se encontró una variación significativa dela temperatura entre los diferentes tiempos (p<0.05). Las compa ­raciones entre pares indicaron que la temperatura se incrementócon el tiempo en todas las fresas (p<0.05). Se detectarondiferencias significativas de temperatura entre diferentes fresasdespués de 0, 2, 4, 6, 8, 10 y 15 segundos (p<0.05)...


Subject(s)
Humans , Dental Instruments , Root Canal Preparation/instrumentation , Transition Temperature , Tooth Root/physiology , Analysis of Variance , Calorimetry/methods , In Vitro Techniques , Data Interpretation, Statistical
8.
Rev. estomatol. Hered ; 26(3)jul. 2016.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1508521

ABSTRACT

Objetivos: Describir las características macroscópicas, microscópicas y la caracterización del material de instrumentos rotatorios de Níquel-Titanio (NiTi), ProTaper Universal, en comparación con instrumentos similares de dudosa procedencia. Material y métodos: El análisis macroscópico se realizó por medio de fotografía macro de las cajas e instrumentos. Para el análisis microscópico, se utilizaron los instrumentos S1 y F1, los cuales fueron seccionados y analizados a través de Microscopía electrónica de barrido comparando las partes activas y las secciones transversales con una magnificación de 300 a 550X. Adicionalmente, se realizó la caracterización de los fragmentos, a través de microanálisis por dispersión de energías de rayos-X (EDX). Resultados: Al análisis macroscópico, las cajas de los sistemas presentaron diferencias en el diseño y especificaciones, los vástagos de los instrumentos presentaron diferencias de forma, color y acabado, y las partes activas de algunos instrumentos, presentaron diferencias de diámetro, forma y acabado. Al análisis microscópico, los instrumentos adulterados presentaron ángulos de corte menos afilados y ausencia de convexidades triangulares. Al comparar la composición química de los instrumentos, el análisis EDX mostró que ambos instrumentos tienen una composición Ni-Ti similar. Conclusiones: Las mayores diferencias entre el sistema ProTaper Universal y su homólogo adulterado se presentaron en el análisis macroscópico. El análisis microscópico presentó diferencias principalmente en el formato de la sección transversal.


Objectives: To describe the macroscopic, microscopic characteristics and material characterization of nickel titanium (NiTi) ProTaper Universal system scompared to similar instruments of dubious origin. Material and methods: Macroscopic analysis was performed using macro photography of the boxes and files. For microscopic analysis, S1 and F1 files were used, which were sectioned and analyzed by scanning electron microscopy comparing active parts and cross-sections at 300-550X magnification. Additionally, the characterization of fragments was performed by energy dispersive x-ray microanalysis (EDX). Results: Macroscopic analysis showed that boxes differed in design and specifications. File shanks showed differences in shape, color, finish. The active part of some files showed differences in diameter, shape and finish. Microscopic analysis indicated that adulterated files showed less sharp cutting angles and absence of triangular convexities. By EDX, comparing the chemical composition of the instruments, it was shown that both instruments have a composition Ni-Ti like. Conclusions: The major differences between ProTaper Universal system and its counterpart adulterated, were presented in macroscopic analysis. Microscopic analysis showed differences mainly in cross-section configuration.

9.
Acta odontol. venez ; 45(4): 568-571, dic. 2007. ilus
Article in Spanish | LILACS | ID: lil-630034

ABSTRACT

El conocimiento de los reparos anatómicos normales de los conductos radiculares y de sus variaciones, es imprescindible para tener una práctica profesional con éxito. Dentro de estas variables morfológicas, se encuentran descrita en la literatura la posibilidad de la presencia de tres conductos radiculares en los primeros premolares superiores. Debido a las dificultades de la realización del tratamiento endodóntico, que estos dientes pueden ofrecer, el profesional debe estar preparado para utilizar recursos tecnológicos en la búsqueda de un tratamiento eficaz. En el presente artículo, se describe un tratamiento endodóntico realizado en un primer premolar superior con tres raíces y tres conductos radiculares. Este tratamiento se realizó con la ayuda de un localizador apical, para la preparación de los tres conductos fue utilizado el sistema rotatorio de Níquel Titanio


The knowledge of the root canals anatomical normality and its variation is essential for the professionals that wish to achieve the success during the endodontic therapy. Among these morphologic variabilities literature mentions the presence of three root canals in maxillary first premolars. Considering the difficulties involved during the treatment of these teeth, the professional should have the ability to use technological resources just to get a more efficient therapy. In our article, we described an endodontic treatment performed in a first premolar with three roots and three canals, using a helpful Apex Locator and NiTi rotary system to provide the shape and cleaning of these canals


O conhecimento das normalidades anatômicas dos canais de radiculares e de suas variações, é imprescindível para os profissionais que desejam realizar um tratamento endodôntico objetivando alcançar o sucesso. Dentre estas variabilidades morfológicas, a literatura cita a possibilidade da presença de três canais radiculares em primeiros pré-molares superiores. Devido às dificuldades que a realização da endodontia nestes dentes pode oferecer, o profissional deve estar habilidade a utilizar recursos tecnológicos na busca de um tratamento mais eficaz. Em nosso artigo, descrevemos um tratamento endodôntico realizado em um primeiro pré-molar superior com três raízes e três canais, com auxílio de localizador apical, e o preparo dos canais realizado com sistemas rotatórios de NiTi


Subject(s)
Female , Bicuspid , Dental Pulp Cavity , Endodontics , Dentistry
SELECTION OF CITATIONS
SEARCH DETAIL