1.
China Medical Equipment ; (12): 21-25, 2018.
Article in Chinese | WPRIM | ID: wpr-706513

ABSTRACT

Objective: To design an online pure water analysis system based on the proton and heavy ion accelerator (IONTRIS system) in Shanghai proton and heavy ion center (SPHIC), and to evaluate its application effect by operating data statistics. Methods: The system used the control system of Siemens S7-300 PLC to collect online data from sensors of pure water system. Analyzing the operation rules and setting the limiting value of alarm, and using WINCC software to develop monitoring and analysis system of central computer so as to real-time operate online data. The application effect of the system was evaluated by comparing the cost of one month consumables between before and after the system was applied. Results: After the system was applied, the real-time monitoring of pure water system was realized, and the efficiency of the consumables was enhanced. Conclusion: The application of the pure water analysis system has a good effect on the operation efficiency of the pure water system.

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 634-638, 2016.
Article in Chinese | WPRIM | ID: wpr-496871

ABSTRACT

Objective To use Monte Carlo method to build a shielding calculation model for the proton and heavy ion treatment room,and to provide a reliable calculation method for shielding design.Methods A Monte Carlo-based FLUKA code was adopted to build the shielding calculation model for the proton and heavy ion treatment room,and to simulate the radiation field distribution in the proton and heavy ion treatment room.The calculation model was verified through the radiation detection around the proton and heavy ions treatment room.Results The FLUKA code-based simulation results were consistent with the radiation detection.Conclusions The shielding calculation model based on FLUKA code can simulate the radiation field from proton and heavy ions.Among the secondary particles,secondary neutrons are the dominant component and the main concern of accelerator shielding design.In shielding calculation,the emphasis should be put on both beam intensity and energy.

3.
Chinese Journal of Radiological Medicine and Protection ; (12): 626-629, 2016.
Article in Chinese | WPRIM | ID: wpr-496869

ABSTRACT

Objective To develop the method for testing the consistency of irradiation field produced by the active spot scanning proton and heavy ion accelerator.Methods Calibration of the EBT3 films were carried out with the calibrated ion beam to establish the dose calibration curve.According to the different proton and carbon ion energies (proton:94.29,150.68,212.62 McV;carbon ion:175.99,283.43,412.54 MeV/u),EBT3 films were located in the solid water phantoms in each therapy room,respectively.Finally,the irradiated EBT3 films were scanned and the radiation field size's deviation and flatness were analyzed.Results In different conditions,radiation field size's deviations were all less than 2 mm and the flatness parameters were all controlled below the 5%.Conclusions EBT3 films can be used to test the active spot scanning proton and heavy ion accelerator's radiation field uniformity.

4.
Chinese Journal of Radiological Medicine and Protection ; (12): 621-625, 2016.
Article in Chinese | WPRIM | ID: wpr-496842

ABSTRACT

Objective To study the quality testing of dose delivery system of the active spot scanning proton and heavy ion accelerator,in order to provide the reference for the quality control of related equipment.Methods In the four therapy rooms,both 0.6 cc chambers and Gafchromic EBT3 films were used,respectively,to test the accelerator for dose reproducibility,dose linearity,dose stability,depth dose distribution,beam scanning position deviation and radiation field uniformity in each therapy room.Results Dose reproducibility variation coefficients are all less than 1.5%,dose linearity's maximum deviations less than 2%,dose stability's deviations less than 2%,depth dose distribution stability within 2%,beam scanning position deviation less than 1 mm,consistency of irradiation field's deviation less than 2 mm,and flatness within ± 5%.Conclusions The indicators about quality testing for the active spot scanning proton and heavy ion accelerator are all in line with the requirements of IEC standards draft.