1.
Journal of Korean Foot and Ankle Society ; : 5-10, 2010.
Article in Korean | WPRIM | ID: wpr-139190

ABSTRACT

PURPOSE: This study was performed to compare the contact area between three different correcting angles after the proximal crescentic and Ludloff osteotomies of the first metatarsal. MATERIALS AND METHODS: We used the two sawbone models. Proximal crescentic (PCO) and Ludloff osteotomies (LO) were performed and secured using K-wires under the correcting intermetatarsal angle (IMA) 5degrees, 10degrees, and 15degrees. Then each 6 osteotomized model was scanned five times and measured the contact area using the calculating program. We excluded the highest and lowest values. RESULTS: The mean area of cutting surface was 189 mm2 in PCO, 863 mm2 in LO. The mean contact area (contact ratio; contact area x100/area of cutting surface) of PCO was 149 mm2 (79%) in 5degrees, 139.5 mm2 (74%) in 10degrees, 107 mm2 (57%) in 15degrees IMA. The mean contact area (contact ratio) of LO was 711 mm2 (82%) in 5degrees, 535.5 mm2 (62%) in 10degrees, 330 mm2 (38%) in 15degrees IMA. CONCLUSION: A significant decrease in the contact area and contact ratio according to increase in correcting IMA was noticed in LO. We recommend the PCO rather than LO, when the IMA is needed to correct over 15degrees.


Subject(s)
Hallux Valgus , Metatarsal Bones , Osteotomy
2.
Journal of Korean Foot and Ankle Society ; : 5-10, 2010.
Article in Korean | WPRIM | ID: wpr-139187

ABSTRACT

PURPOSE: This study was performed to compare the contact area between three different correcting angles after the proximal crescentic and Ludloff osteotomies of the first metatarsal. MATERIALS AND METHODS: We used the two sawbone models. Proximal crescentic (PCO) and Ludloff osteotomies (LO) were performed and secured using K-wires under the correcting intermetatarsal angle (IMA) 5degrees, 10degrees, and 15degrees. Then each 6 osteotomized model was scanned five times and measured the contact area using the calculating program. We excluded the highest and lowest values. RESULTS: The mean area of cutting surface was 189 mm2 in PCO, 863 mm2 in LO. The mean contact area (contact ratio; contact area x100/area of cutting surface) of PCO was 149 mm2 (79%) in 5degrees, 139.5 mm2 (74%) in 10degrees, 107 mm2 (57%) in 15degrees IMA. The mean contact area (contact ratio) of LO was 711 mm2 (82%) in 5degrees, 535.5 mm2 (62%) in 10degrees, 330 mm2 (38%) in 15degrees IMA. CONCLUSION: A significant decrease in the contact area and contact ratio according to increase in correcting IMA was noticed in LO. We recommend the PCO rather than LO, when the IMA is needed to correct over 15degrees.


Subject(s)
Hallux Valgus , Metatarsal Bones , Osteotomy