Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Year range
1.
Chinese Journal of Radiological Medicine and Protection ; (12): 358-362, 2021.
Article in Chinese | WPRIM | ID: wpr-910321

ABSTRACT

Objective:To obtain the distribution characteristics of radon levels in drinking water in cities of China and analysis their influencing factors.Methods:A total of 31 cities were selected and 406 tap water samples were collected in accordance with the sampling plan based on administrative division. Radon concentrations in the water samples were determined by using RAD7 H 2O measuring devices, and the closed loop liquid-gas balance method and grab method . The radon concentrations in the gas loop were measured by using semiconductor detector. After four measurement periods, radon concentrations in water were calculated. Results:The arithmetic mean of radon concentrations in drinking water from 31 cities was (4.92±9.44) Bq/L and the geometric mean (0.71±7.77) Bq/L, ranging from less than the lower detection limit (LLD) to 43.15 Bq/L. For 84.2% of drinking water samples, radon concentrations were less than US EPA recommended 11.1 Bq/L, all lower than the EU-recommended value of 100 Bq/L.Conclusions:The radon concentrations in drinking water are higher in northeastern, northwestern, southwestern, northern China than those in southern, central China and eastern China. The factors influencing radon concentrations in drinking water are closely related to geological structure and water source type. Compared with the global values, the radon concentrations in drinking water in our cities are low and safe in general in China.

2.
Eng. sanit. ambient ; 24(5): 909-918, set.-out. 2019. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1056099

ABSTRACT

RESUMO A presença de cianobactérias e cianotoxinas em reservatórios no estado de São Paulo constitui um desafio para produção de água potável. Sete reservatórios utilizados para abastecimento público, monitorados pela Companhia Ambiental do Estado de São Paulo (CETESB), foram analisados em relação a cianobactérias, microcistina e indicadores de contaminação fecal entre 2011 e 2015. Calcularam-se porcentagens de não conformidade com padrões de qualidade. Os resultados evidenciaram a presença de cianobactérias e microcistina (máximo de 22,4 g.L-1), além de conflitos com os padrões da Resolução CONAMA nº 357/2005 (BRASIL, 2005), o que reforça a importância de investimentos em coleta e tratamento de esgotos sanitários. É discutida a necessidade de maior integração entre as leis e resoluções que versam sobre qualidade da água, além do melhor planejamento dos recursos hídricos, com foco em metas progressivas de melhoria da qualidade da água.


ABSTRACT The occurrence of cyanobacteria and cyanotoxins in reservoirs in São Paulo State is a challenge to the production of drinking water. Seven reservoirs used for public supply and monitored by CETESB, were analyzed regarding cyanobacteria, microcystin and indicators of fecal contamination between 2011-2015. The percentages of non-compliance with water quality standards were calculated. Results highlighted the presence of cyanobacteria and microcystin (maximum of 22.4 µg/L), as well as conflicts with the standards provided by CONAMA Resolution No. 357/2005 (BRASIL, 2005), which reinforces the importance of investments in sanitary sewage collection and treatment. The need for greater integration between laws and resolutions on issues related to water quality were also discussed, as well as better planning of water resources, focusing on progressive goals for water quality improvement.

3.
Vigil. sanit. debate ; 6(4): 47-55, nov.2018.
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-966703

ABSTRACT

Introdução: No estado de São Paulo, a concentração de flúor na água de abastecimento público deve ser mantida na faixa de 0,6 a 0,8 mg/L, a fim de prevenir a cárie e evitar o risco de fluorose. Objetivo: Avaliar a concentração de fluoretos na água de abastecimento público dos municípios de abrangência do Grupo de Vigilância Sanitária de Bauru. Método: Os dados foram extraídos da rotina do Instituto Adolfo Lutz ­ Bauru e oriundos de 38 municípios monitorados pelo Programa de Vigilância da Qualidade da Água para Consumo Humano (Proágua), no período de 2007­2016. As análises laboratoriais foram realizadas utilizando-se o método potenciométrico com eletrodo íon-seletivo e a interpretação dos resultados baseou-se na Resolução SS nº 250/95 e na classificação proposta pelo Centro Colaborador do Ministério da Saúde em Vigilância da Saúde Bucal (CECOL). Resultados: Das 8.887 amostras analisadas, 31,1% apresentaram teores inadequados de íons fluoretos, sendo que 22,7% estavam abaixo e 8,4% acima do limite estabelecido pela legislação. De acordo com a proposta do CECOL, 59,4% das amostras exibiram benefício máximo para prevenção de cárie e 0,6% revelaram risco muito alto para produção de fluorose dentária. Conclusões: Tais dados apontam a necessidade de aprimorar o controle operacional do processo de fluoretação e enfatiza a importância da vigilância da qualidade da água.


Introduction: In the State of São Paulo, the concentration of fluoride in the public water supply should be maintained in the range of 0.6 to 0.8 mg/L, in order to prevent caries and avoid the risk of fluorosis. Objective: To evaluate the concentration of fluoride in public water supply in the municipalities covered by the Bauru Sanitary Surveillance Group. Method: Data were extracted from the routine of the Adolfo Lutz Institute ­ Bauru, from 38 municipalities monitored by the Proágua Program, in the period 2007­2016. Laboratory analyses were performed using the potentiometric method with ion-selective electrode and the interpretation of the results was based on Resolution SS-250/95 and the classification proposed by the Collaborating Center of the Ministry of Health in Oral Health Surveillance (CECOL) Results: Of the 8,887 samples analyzed, 31.1% had inadequate levels of fluoride ions, with 22.7% being below and 8.4% above the limit established by the legislation. According to the CECOL proposal, 59.4% of the samples showed maximum benefit for caries prevention and 0.6% revealed a very high risk for the production of dental fluorosis. Conclusions: These data point out the need to improve the operational control of the fluoridation process and emphasize the importance of water quality surveillance.

4.
Eng. sanit. ambient ; 21(3): 615-622, jul.-set. 2016. tab
Article in Portuguese | LILACS | ID: lil-794649

ABSTRACT

RESUMO A água de abastecimento público pode ser um veículo de doenças e agravos à saúde humana, portanto, é necessário um tratamento eficiente e constantes avaliações da sua qualidade. O presente estudo objetivou avaliar a dinâmica populacional de indicadores microbiológicos e parâmetros físico-químicos da qualidade da água em diferentes pontos de uma estação de tratamento de água do tipo convencional, do sistema de distribuição e dos mananciais de abastecimento do município de Jaboticabal, São Paulo, nas estações chuvosa e de seca. Os resultados demonstraram que, apesar do manancial superficial apresentar qualidade microbiológica inferior (comparado aos demais mananciais estudados), após tratamento convencional foi obtida a potabilidade do mesmo. A estação chuvosa foi crítica para amostras coletadas nas etapas logo após adição de cloro, principalmente no sistema de distribuição do manancial subsuperficial. Dentre os pontos avaliados na rede de distribuição, os reservatórios domiciliares apresentaram o maior número de amostras fora do padrão de potabilidade, principalmente na rede abastecida pelo manancial subsuperficial. São necessárias estratégias para a melhoria do processo de tratamento da água do dreno - voltado para a redução da turbidez - principalmente na estação chuvosa; assim como programas de educação em saúde para a população, a fim de melhorar a qualidade da água no ponto de consumo, a partir da limpeza periódica dos reservatórios domiciliares.


ABSTRACT The public-supply water can be a vehicle of disease and harm to human health, therefore, efficient treatment and constant evaluation of its quality is required. The present study aimed to evaluate the population dynamics of microbiological and physico-chemical indicators of water quality parameters at different points of a water treatment plant of the conventional type, in the distribution system and sources of supply in Jaboticabal city, São Paulo state, Brazil, in the rainy and dry seasons. The results showed that although the present fountain surface presents worse microbiological quality (compared to other sources studied) after the conventional treatment, it became potable. The rainy season was critical for samples collected in steps after adding chlorine, especially in the distribution of sub-surface source system. Among the evaluated points in the distribution network, domestic containers had the highest number of samples outside the potability standards, mainly those fueled by the sub-surface source network. Strategies to improve the treatment process of the drain water (turbidity reduction) are needed, especially during the rainy season; as well as health education programs in order to improve water quality at the point of consumption by periodic cleaning of domestic containers.

5.
Eng. sanit. ambient ; 13(1): 78-87, jan.-mar. 2008. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-485076

ABSTRACT

Neste trabalho é apresentada uma avaliação comparativa preliminar entre os sistemas de tratamento de água por ultrafiltração, convencional e convencional com carvão ativado, com base nos custos diretos de implantação e operação, utilizando-se os resultados obtidos em uma unidade piloto de ultrafiltração, instalada junto à captação de água no Reservatório Guarapiranga. Para comparação considerou-se os dados relativos à eficiência da remoção de Carbono Orgânico Total. A avaliação de custos foi feita pelo método de cálculo do período de retorno de investimento, obtendo-se valores de R$ 0,20/m³ para o sistema convencional e R$ 0,40/m³ para os outros sistemas. Estes resultados mostram o potencial de processos de separação por membranas no tratamento de água para abastecimento público.


In this work it is presented a comparative evaluation for ultrafiltration, conventional, and conventional with activated carbon water treatment systems, considering direct capital and operational costs, based on the results of an ultrafiltration pilot unit, installed at the Guarapiranga's Reservoir. In order to compare the costs it was considered Total Organic Carbon removal efficiency. Cost evaluation was performed based on the pay back method, resulting in a value of R$ 0.20/m3 for conventional water treatment system, and R$ 0.40/m3 for the others. These results clearly demonstrate the high potential of membrane separation technology for drinking water treatment.


Subject(s)
Fees and Charges , Ultrafiltration , Water Purification , Water , Water Supply
SELECTION OF CITATIONS
SEARCH DETAIL