Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Journal of the Korean Society of Magnetic Resonance in Medicine ; : 20-26, 2007.
Article in Korean | WPRIM | ID: wpr-49834

ABSTRACT

PURPOSE: The purpose of the present study was to develop and optimize solenoid coil for animal- model in 3 T MRI system and investigate and compare with the birdcage coil concerning the image quality with the various parameters such as SNR and Q-factor. MATERIALS AND METHODS: Solenoid coil for animal-model was made on the acryl structure (diameter 4 cm, length 10 cm) 3 times-winding cooper tape of width 2 cm , thickness 0.05 cm and length 10 cm with 2 cm interval between winded tapes. Capacitors from 2 pF to 100 pF were used, and the solenoid coil was designed for receiver only coil. RESULTS: SNR of the developed solenoid was 985 in CuSO4 0.7 g/L and 995 in rat experiment. Q-factor was 84-89 in unloaded condition and 203-206 in loaded condition. CONCLUSION: The resolution of the image obtained from solenoid was relatively higher than that of the conventional birdcage coil. In addition, the homogeneity of RF field by coil simulation was significantly excellent. The present study demonstrated that the solenoid coil could be useful to obtain small animal images with better contrast, resolution, visibility than images from birdcage.


Subject(s)
Animals , Rats , Magnetic Fields , Magnetic Resonance Imaging , Wind
2.
Journal of the Korean Society of Magnetic Resonance in Medicine ; : 232-238, 1999.
Article in Korean | WPRIM | ID: wpr-88826

ABSTRACT

PURPOSE: To apply a distributed circuit theory, to develop a head-size transverse electromagnetic(TEM) resonator coil for a home-built 3T whole-body MRI system and to report an efficiency of the coil. MATERIALS AND METHODS: The dimension of TEM resonator with 16 cavity element, the diameter of copper rod was 0.63cm and its length was 13.75cm. As raw materials, the purity of copper rod was 98% and the dielectric constant of teflon was 2.08. RESULTS: The TEM head-size resonator with 16cavity elements exhibiting 9-mode resonances was robust to the surrounding influences owing to the self-shielding structure. The isolation of quadrature with a human brain was 364 and the ratio of Q(unloaded/Q(loaded) was 2.9. CONCLUSION: It was successfully demonstrated that the TEM head-size resonator with high Q factor can provide high quality MR images at 3T MRI system. Also, the TEM resonator coil has an advantage for a fine tune with length adjustment of each cavity elements. Thus, it is expected that the TEM resonator at 3T, even higher field could be used in the clinical and research studies in near future.


Subject(s)
Humans , Brain , Copper , Head , Magnetic Resonance Imaging , Polytetrafluoroethylene
SELECTION OF CITATIONS
SEARCH DETAIL