ABSTRACT
Objective To verify the reliability of dose parameters of radiotherapy under reference and non-reference conditions by using TLD.Methods Dose parameters were verified by using TLDs under reference and non-reference conditions,including the maximum dose in axel of 5 electron beams with energy of 9 MeV and the variations of dose by depth,source-skin distance,exposure field and 45° wedge for 10 photon beams with energy of 6 MV in 5 hospitals.Results The average relative deviation of 6 MV photon beam measured between TLDs and finger ionization chambers were 4.45%,within ± 7% as required by IAEA.The average relative deviation of 9 MeV electron beam measured between TLDs and plane parallel chambers were 2.45%,within ± 5% was required by IAEA.Conclusions Measuring dosimetric parameters by using TLDs under reference and non-reference conditions was reliable and feasible.
ABSTRACT
Objective To verify the methodology for auditing dosimetric parameters in reference and non-reference conditions with thermoluminescent dosimeters (TLDs).Methods Under reference and non-reference conditions,the established TLD methods were used to observe the absorbed dose variations with depth,SSD,field size and 45 wedges for 10 photon beams at 5 hospitals.Dosimetric parameters,including doses at Dmax points in axis,on 5 electron beams of 9 MeV were measured.The measurement results were compared between the TLDs and plane parallel ionization chambers.Results For 6 MV photon beams,the relative deviation of between finger ionization chamber method and TLD chips was in the range of-1.7% to 5.4% under on-axis non-reference conditions,and-6.3% to-0.6% under off-axis non-reference conditions,respectively,all within the range of ≤ ± 7% as required by the IAEA.The relative deviation between plane parallel chamber and TLD method was-2.3% to 3.7%,within ± 5% as required by the IAEA.Conclusions It is convenient and feasible to use TLD method for quality audits of dosimetric parameters in radiotherapy.
ABSTRACT
Objective To verify the reliability of radiotherapy dosimetric parameters in reference and non-reference conditions using thermoluminescent dosimeters (TLDs).Methods Using the established TLD method,the dose variations with different radiation field sizes and 45 ° wedge plate were verified for 10 photon beams of 6 MV,together with dosimetric parameters at the point of maximum axial dose for 4 electron beams of 9 MeV under reference and non-reference conditions.Comparisons were made between TLD results and finger ionization chamber results.Results The average relative deviation,for 6 MV photon beams,between TLD results and finger ionization chamber measurements was 4.7%,within ± 7% as required by the IAEA.The average relative deviation,for 9 MeV electron beam,between TLD results and plane parallel ionization chamber measurements was 2.4 %,not beyond ± 5% permitted by IAEA.Conclusions Using TLD method to verify the radiotherapy dosimetric parameters in reference and non-reference conditions was reliable,simple and feasible.