Indian J Ophthalmol ; 2020 Apr; 68(4): 583-587
Article | IMSEAR | ID: sea-197899

ABSTRACT

Purpose: To assess the role of Scheimpflug imaging in improving the accuracy of reference marking for toric IOL implantation. Methods: In this prospective, randomized, clinical trial all patients with cataract and pre-existing significant regular corneal astigmatism, who required implantation of a toric IOL were included in the study, and patients with any ocular pathology or abnormality were excluded. Patients were divided into two groups: For one group of patients, Group I (GI), reference marking was finalized using slit lamp only, and for the second group, Group II (GII), after slit lamp marking, the reference marks were checked using Goniometer of Scheimpflug imaging. The primary outcome was to determine the axis of toric intraocular lens (IOL) postoperatively (within 1 hour) and compare it with the desired axis of placement. Results: We found a statistically significant difference in the two groups (P < 0.001) suggesting Group II (4 step technique) is better than Group I (3 step technique). Conclusion: Scheimpflug imaging, an extra step preoperatively, is an effective measure to reduce errors in reference marking and thereby improving the refractive outcome of toric intraocular lens.

2.
Indian J Ophthalmol ; 2016 Aug; 64(8): 559-562
Article in English | IMSEAR | ID: sea-179403

ABSTRACT

Introduction: Toric intraocular lenses (IOLs) are an effective way of compensating preexisting corneal astigmatism during cataract surgery. To achieve success, it is imperative to align the toric IOLs in desired position and preoperative reference marking is one among the three important steps for accurate alignment. To make the marking procedure simpler and effective, we have modified the conventional three‑step slit lamp‑based technique. Materials and Methods: Patient is seated in front of the slit lamp and asked to keep the chin over chin rest. A 26‑gauge bent needle with tip stained by sterile blue ink marker is used to make anterior stromal puncture (ASP) at the edges of horizontal 180° axis near the limbus. Results: A total of 58 eyes were retrospectively evaluated. Mean (+/-SD) IOL deviation on day 1 and day 30 was 5.7 ± 6.5° and 4.7 ± 5.6°, respectively. Median IOL misalignment on day 1 and day 30 was 3°. Redialing of IOL was required in 2 (3.4%) eyes only, all of which were performed within 1 week of surgery. In total, 2 (3.7%) eyes had a residual astigmatism of − 0.5 Dcyl and − 1.0 Dcyl, respectively. Conclusion: ASP is an effective technique for reference marking, technically simpler and can be practiced by most of the surgeons. It avoids the necessity of high‑end sophisticated machinery and gives a better platform for the reference corneal marking along with the benefit of reproducibility and simplicity.

SELECTION OF CITATIONS
SEARCH DETAIL