Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Radiological Medicine and Protection ; (12): 799-805, 2022.
Article in Chinese | WPRIM | ID: wpr-956863

ABSTRACT

Objective:To test the relative response of a detector matrix used for measuring of the dose distribution in radiotherapy in order to ensure the accuracy and reliability of dose distribution measurement result.Methods:The two adjacent detectors can be irradiated at the same radiation dose by translating the detector matrix. The relative response of each detector to the reference detector can be obtained by combining the recursive algorithm. At the same time, the measurement data at different test steps are corrected to the reference step by setting the reference step, which correct the influence on the relative response result caused by the variation of the radiation condition and the detector response.Results:Based on the actual test of a 32 × 32 detector matrix, the relative response of each detector of the detected detector matrix to the reference detector varied from 0.896 to 1.077, with the expanded uncertainty of the relative response result being 0.8% ( k=2). Conclusions:On the premise of no known distribution of a radiation field, the relative response relationship of each detector of a detector matrix can be obtained by this method accurately and expediently, which provides a basic method for the performance evaluation of the detector matrix. The same idea can also be used to determine the relative response relationship of other detector matrices for different measurement purposes.

2.
China Journal of Chinese Materia Medica ; (24): 2538-2543, 2019.
Article in Chinese | WPRIM | ID: wpr-773229

ABSTRACT

Bile acids( BAs),the major constituents of bile,are also known to be potential biomarkers of various diseases,especially liver disease. The systematic analysis of BAs is believed to be of great importance towards the clarification of the effective material basis for bile-type medicines,and the diagnosis and therapy of related diseases as well. As a part of systematic study on bile-type medicine ongoing in our group,this study lays emphasis on the isomer discrimination,and the improvement of analytical method of BAs. Further,this method was subsequently applied to elucidate in depth the chemical profile of BAs in yak bile. Regarding isomer discrimination for BAs,we constructed relative response-collision energy curves( RRCECs) by high performance liquid chromatographyion trap-time of flight-mass spectrometry( HPLC-IT-TOF-MS) in combination with high performance liquid chromatography-triple quadrupole-linear ion trap mass spectrometry( HPLC-Qtrap-MS). As a result,both the optimum collision energy( OCE) and CE_(50) exhibited great correlations with structural characteristics,thus enabling the isomer distinguishing,such as unconjugated BAs,glycine-conjugated BAs,and taurine-conjugated BAs. According to information provided by mass spectrometry,the comparison of OCE and CE_(50),retention time matching,combined with reference substances and database retrieval,a total of 30 bile acid derivatives were observed and identified in yak bile. The newly developed method could serve as a feasible tool for the in-depth characterization of BAs in bile and biological samples.


Subject(s)
Animals , Cattle , Bile , Chemistry , Bile Acids and Salts , Chemistry , Chromatography, High Pressure Liquid , Mass Spectrometry , Taurine