Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Rev. Fac. Odontol. (B.Aires) ; 37(85): 59-66, 2022. ilus
Article in Spanish | LILACS | ID: biblio-1411262

ABSTRACT

En este artículo se desarrolla el consenso alcanzado entre profesores, referido a los conceptos generales, componentes y la secuencia del diseño de la prótesis parcial removible, durante la formación del odontó-logo en el ámbito de la Facultad de Odontología de la Universidad de Buenos Aires (AU)


This article develops the consensus between professors on the general concepts, components, and the sequence of the design of the partial removable prosthesis during the training of the dentist in the field of the Faculty of Dentistry of the University of Buenos Aires (AU)


Subject(s)
Dental Prosthesis Design/methods , Consensus , Denture, Partial, Removable , Schools, Dental , Students, Dental , Dental Prosthesis Retention/methods , Dental Occlusion , Dental Stress Analysis , Education, Predental/methods , Faculty, Dental
2.
RGO (Porto Alegre) ; 68: e20200054, 2020. tab
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1136051

ABSTRACT

ABSTRACT Objective The aim of this study was to evaluate the models and plannings of metallic framework of removable partial prosthesis sent to dental laboratories in the city of Recife. Methods: The physical and technical conditions of plaster models were sent by the dentists to 4 dental laboratories. All models were examined, photographed and recorded on a form according to the research objective. Results: A total number of 235 models sent by dental surgeons were used to prepare the metallic structure, in which none of the models presented surveying nor the path of insertion. Out of the 235 models, 41 (17.44%) presented serious failures, such as positive and negative bubbles, broken dental elements, direct retainers and damaged edentulous areas. With respect to the planning, only 22 (9.35%) models were presented with the metallic framework planning, but in an unsatisfactory way. Regarding mouth preparation, no model presented a guide plane, and only 6.8% of models had rests seats, but incorrectly prepared. Conclusion: The models evaluated presented poor quality, lack of planning and no mouth preparation. This shows the need for dental surgeons to be aware of the appropriate prosthesis models and plannings in order to ensure a satisfactory and long-term rehabilitation of the patient, as well as preserving the remaining mouth structures.


RESUMO Objetivo Avaliar os modelos e planejamentos das estruturas metálicas das próteses parciais removíveis enviadas aos laboratórios de prótese dentária da cidade do Recife. Métodos Foram avaliadas as condições físicas e técnicas dos modelos de gesso enviados pelos dentistas à 4 laboratórios de prótese dentária. Todos os modelos foram examinados, fotografados e registrados por meio de um formulário de acordo com o objetivo da pesquisa. Avaliou-se 235 modelos enviados pelos cirurgiões dentistas para confecção da estrutura metálica, na qual nenhum dos modelos apresentou delineamento e registro do eixo de inserção. Resultados Dos 235 modelos, 41 (17,44%) apresentaram falhas graves, tais como bolhas positivas, bolhas negativas, elementos dentários quebrados, retentores diretos e áreas edêntulas danificados. Quanto ao planejamento, apenas 22 (9,35%) modelos apresentavam-se com o desenho da estrutura metálica, porém, de maneira insatisfatória. Quanto ao preparo de boca, nenhum modelo apresentou preparo de plano guia, e apenas 6,8% dos modelos possuíam nichos, porém confeccionados de maneira incorreta. Conclusão Os modelos avaliados apresentaram qualidade insatisfatória, ausência de planejamento e realização de preparo de boca. Isto demonstra a necessidade de conscientização dos cirurgiões dentistas para a confecção dos modelos e planejamentos adequados das próteses, a fim de garantir uma reabilitação duradoura e satisfatória ao paciente, assim como proservação das estruturas bucais remanescentes.

3.
Rev. Fac. Odontol. Univ. Antioq ; 24(1): 151-167, jul.-dic. 2012. ilus, tab
Article in Spanish | LILACS | ID: lil-678092

ABSTRACT

La enfermedad periodontal afecta la salud del paciente comprometiendo la forma, función y estética del sistema estomatognático, llevando a un deterioro notable de la calidad de vida de las personas. En este caso clínico se presenta el tratamiento integral de unpaciente de sexo masculino de 43 años de edad con periodontitis crónica avanzada generalizada que incluyó: tratamiento periodontal no quirúrgico, quirúrgico y de rehabilitación oral, hecho durante dieciocho meses por un estudiante de último año del pregrado y un grupo de docentes especialistas en periodoncia y rehabilitación oral bajo la modalidad docencia-asistencial de la Facultad de Odontología de la Universidad de Antioquia (Medellín, Colombia.


Periodontal disease affects the patient’s health altering the form, function, and esthetics of the stomatognathic system andproducing huge deterioration in the person’s quality of life. This clinical case presents the comprehensive treatment of a 43-year-old male patient with generalized advanced chronic periodontitis including: non-surgical and surgical periodontal treatment and oral rehabilitation during a period of eighteen months by a senior undergraduate student and a group of professors specialized in periodontics and oral rehabilitation under the modality of teaching-social assistance at the School of Dentistry of Universidad de Antioquia (Medellín, Colombia


Subject(s)
Humans , Chronic Periodontitis , Dental Prosthesis , Disinfection
4.
Rev. odonto ciênc ; 26(2): 145-150, 2011. ilus, tab
Article in English | LILACS, BBO | ID: lil-611661

ABSTRACT

PURPOSE: To evaluate the influence of using either ultrasonic CVD (Chemical Vapor Deposition) or conventional rotary diamond tips on the adhesive strength of cingulum rest seats made of composite resin over bovine dentin. METHODS: Twenty specimens were produced for each experimental group. For specimens in Group 1, the dentin was exposed with a rotary diamond tip; in Group 2 this procedure was performed using an ultrasonic CVD diamond tip. In both groups a two-step self-etching adhesive system was used, and the shape and size of the rest seats made of composite resin were standardized. The specimens were subjected to a shear assay using a universal testing machine at a crosshead speed of 0.5 mm/min. Data were analyzed by Student's t-test at the significance level of 0.05. RESULTS: There was a statistically significant difference (P=0.028) between the means of the experimental groups: 24 kgf for Group 1 and 31 kgf for Group 2. CONCLUSION: Dental preparation with dentin exposure in the cingulum region by using ultrasonic CVD diamond tip showed the highest bond strength of self-etching adhesive system and composite rest seats for support of removable partial dentures.


OBJETIVO: Avaliar a influência do uso de pontas ultra-sônica em diamante CVD e de pontas rotatórias convencionais na força adesiva do descanso para apoio de cíngulo em resina composta, confeccionadas sobre dentina de dente bovino. METODOLOGIA: Foram confeccionados 20 espécimes para cada grupo experimental. A exposição dentinária foi realizada com a ponta diamantada rotatória nos espécimes do Grupo 1 e com ponta diamantada CVD no Grupo 2. Em ambos os grupos foi utilizado um sistema adesivo autocondicionante de dois passos. A forma e o tamanho do descanso em resina composta foram padronizados com uma matriz de acetato. Os espécimes foram submetidos ao ensaio de cizalhamento em máquina de teste universal com velocidade constante de 0,5 mm/min. Os dados foram analisados por teste t de Student ao nível de significância de 0,05. RESULTADOS: O teste t-Student demonstrou diferença estatisticamente significante entre os grupos (P=0,028), com médias de 24 kgf para o grupo 1 e 31 kgf para o grupo 2. CONCLUSÃO: O preparo dental com exposição de dentina em região de cíngulo com ponta ultra-sônica CVD promoveu maior resistência de união do sistema adesivo autocondicionante com o descanso para apoio de cíngulo em resina composta para uso em prótese parcial removível.


Subject(s)
Animals , Cattle , Dentin , Dental Instruments , Denture, Partial, Removable , Composite Resins
5.
RGO (Porto Alegre) ; 57(3): 273-279, jul.-set. 2009. tab, ilus
Article in Portuguese | LILACS, BBO | ID: lil-527906

ABSTRACT

Objetivo: Avaliar a qualidade dos modelos para a confecção de próteses parciais removíveis. Métodos: Foram analisados 140 modelos em cinco laboratórios de prótese dentária da cidade de Teresina, Piauí, registrados no Conselho Regional de Odontologia. Uma ficha foi aplicada, com 14 questões fechadas e os dados coletados foram submetidos à análise estatística utilizando-se o programa SPSS. Os modelos foram analisados à luz natural ou artificial e fotografados para fins de registro e ilustração. Resultados: Os resultados demonstraram que em 100% dos casos o material de moldagem utilizado foi o alginato, sendo 96,43% dos modelos vazados pelo cirurgião-dentista. Destes, 64,47% foram vazados em gesso pedra e 36,43% em gesso especial. De acordo com critérios como qualidade de superfície, reprodução de detalhes, presença de bolhas e/ou nódulos, reprodução adequada da área edentada, 78,57% dos modelos foram considerados inadequados. Os modelos foram, na sua maioria (96,43%), montados em articulador pelo técnico de prótese dentária, sendo que apenas um cirurgião-dentista encaminhou o registro para montagem dos modelos. O articulador tipo charneira foi utilizado em 97,14% das montagens. Em 94,29% dos casos o planejamento e desenho não foram executados pelo cirurgião-dentista e em 87,86% dos casos nenhuma evidência de preparo de boca foi encontrada. A comunicação entre o cirurgião-dentista e o técnico de prótese dentária foi, na sua maioria, feita por telefone, em 80% dos casos. Conclusão: Deste modo, constatou-se que a prótese parcial removível continua sendo negligenciada em relação à sua confecção clínica e laboratorial, através de uma transferência excessiva de responsabilidades do cirurgião-dentista ao técnico de prótese dentária e de uma comunicação ineficaz entre ambos.


Objective: To evaluate the quality of models for making removable partial dentures. Methods: In this Study, 140 models were analysed in 05 dental prosthesis laboratories in the city of Teresina, Piauí, Brazil, registered with the Conselho Regional de Odontologia. A form containing 14 closed questions was applied, and the data collected were submitted to statistical analysis using the SPSS program. The models were analysed under natural or artificial light and photographed for record and illustration purposes. Results: The results showed that in 100% of the cases the molding material used was alginate, and 93.43% of the models were poured by the dentist. Of these, 64.47% were poured in stone plaster and 36.43% in special plaster. According to criteria such as surface quality, reproduction of details, presence of bubbles and/or nodules, adequate reproduction of the edentulous area, 78.57% of the models were considered inadequate. The majority of the models (96.43%), were mounted in an articulator by the Dental Laboratory Technician, but only 1 dentist sent the record for mounting the models. The hinge type articulator was used in 97.14% of the mountings. In 94.29% of the cases, the planning and design were not executed by the dentist and in 87.86% of the cases no evidence of mouth preparation was found. In 80% of the cases, communication between the dentist and the Dental Laboratory Technician was done by telephone. Conclusion: Thus it was verified that the removable partial denture continues to be neglected as regards its clinical and laboratorial fabrication, through an excessive transfer of responsibilities from the dentist to the Dental Laboratory Technician and an inefficient communication between the two.


Subject(s)
Humans , Dental Technicians , Dentists , Models, Dental/standards , Dental Prosthesis Design/methods , Surveys and Questionnaires
SELECTION OF CITATIONS
SEARCH DETAIL