Acta bioquím. clín. latinoam ; 45(2): 335-347, abr.-jun. 2011. graf, tab
Article in Spanish | LILACS | ID: lil-633156

ABSTRACT

En el proceso de verificación de métodos se obtienen datos del desempeño del sistema de medición en las condiciones de trabajo del laboratorio; luego esto es cotejado con las especificaciones brindadas por el fabricante de reactivos y con los requerimientos de calidad disponibles de distintas fuentes. Los objetivos del presente trabajo fueron aplicar protocolos de evaluación de métodos publicados en guías internacionales (CLSI, Clinical Laboratory Standard Institute) para verificar el correcto rendimiento de las metodologías evaluadas y diseñar e implementar una estrategia de control de calidad interno (CCI) que permita evaluar la estabilidad del sistema de medición en el tiempo. Se evaluaron glucosa, creatinina y láctico deshidrogenasa (LDH); sobre las metodologías para la valoración de los mismos se realizaron los ensayos correspondientes a la verificación de precisión y veracidad, linealidad, límite de detección, comparación de equipos y establecimiento de valores de referencia de acuerdo con lo establecido en las guías CLSI EP15-A2, EP6-A, EP17-A, EP9-A2, C28-A2, respectivamente. En todos los ensayos realizados se cumplieron con las especificaciones estipuladas por el fabricante para cada analito, como así también con los requerimientos de calidad elegidos para el error total permitido. Además, se determinó el punto operativo y se especificaron las reglas de CCI adecuadas para el seguimiento del desempeño de estas metodologías. Con los resultados obtenidos se construyó una matriz de calidad para hacer el seguimiento mensual de los parámetros evaluados. Aplicando procedimientos de verificación de métodos se demostró la aceptabilidad de los parámetros analíticos evaluados. La verificación de los métodos permite diseñar y aplicar una estrategia de CCI para evaluar la estabilidad analítica de los sistemas de medición en el tiempo, dentro de un marco de seguridad analítica exigido para métodos acreditados.


The process of method verification (MV) generates data about the performance of a measuring system in current laboratory working conditions; later, the information obtained is compared to the specifications issued by the assay manufacturer and International Regulating Organizations. The objectives of this study were: 1) to apply evaluation protocols established by international guidelines (CLSI, Clinical Laboratory Standards Institute) to verify the correct performance of the methodologies under analysis; 2) to design and implement a strategy of internal quality control (IQC) that allows evaluating the stability of the measuring system in time. Glucose, creatinine and lactate deshidrogenase were subject to analysis. Verification of precision, trueness, linearity detection limit, instrument comparison and reference values were performed under the provisions of CLSI EP-15A2, EP6A, EP17-A, EP9-A2 and C28-A2 guidelines, respectively. For every assay, the procedures indicated by the manufacturer were respected, as well as the quality requirements chosen for total allowed error. An operative point was obtained and adequate ICQ rules for monitoring the performance of those methodologies were established. With the results obtained, a quality matrix was built for a monthly follow-up of the evaluated parameters. The acceptability of the evaluated analytical parameters was proved by the application of MV procedures. Furthermore, the MV enabled to design and implementation of an ICQ strategy to test the analytical stability of the measuring systems, in the analytical safety environment required for accredited methods.


No processo de verificação de métodos são obtidos dados do desempenho do sistema de medição nas condições de trabalho do laboratório; depois isto é comparado com as especificações oferecidas pelo fabricante de reagentes de laboratório e com os requerimentos de qualidade disponíveis em diversas fontes. Os objetivos do presente trabalho foram aplicar protocolos de avaliação de métodos publicados em guias internacionais (CLSI, Clínical Laboratory Standard Institute) para verificar o correto rendimento das metodologias avaliadas e desenhar e implementar uma estratégia de controle de qualidade interno (CCI) que permita avaliar a estabilidade do sistema de medição no tempo. Foram avaliadas glicose, creatinina e desidrogenase lática (LDH); sobre as metodologias para a avaliação dos mesmos foram realizados os ensaios correspondentes à verificação de precisão e veracidade, linearidade, limite de detecção, comparação de equipamentos e estabelecimento de valores de referência conforme o estabelecido nos guias CLSI EP15-A2, EP6-A, EP17-A, EP9-A2, C28-A2, respectivamente. Em todos os ensaios realizados foram cumpridas as especificações estabelecidas pelo fabricante para cada analito, bem como com os requerimentos de qualidade selecionados para o erro total permitido. Além disso, foi possível determinar o ponto operacional e especificar as regras do CCI adequadas para o acompanhamento do desempenho destas metodologias. Com os resultados obtidos se construiu uma matriz de qualidade para fazer o acompanhamento mensal dos parâmetros avaliados. Aplicando procedimentos de verificação de métodos foi demonstrada a aceitabilidade dos parâmetros analíticos avaliados. A verificação dos métodos permite desenhar e aplicar uma estratégia de CCI para avaliar a estabilidade analítica dos sistemas de medição no tempo, dentro de um quadro de segurança analítica exigido para métodos com credenciamento.


Subject(s)
Clinical Laboratory Services/organization & administration , Clinical Laboratory Techniques/standards , Quality Control , Total Quality Management , Laboratory Critical Values , Methods , Quality Indicators, Health Care , Reference Values , Statistics