1.
Braz. dent. sci ; 27(1): 1-6, 2024. ilus
Article in English | LILACS, BBO | ID: biblio-1532548

ABSTRACT

Background: Odontogenic maxillary sinusitis caused by a foreign body presents diagnostic and therapeutic challenges due to its infrequent occurrence and unique characteristics compared to sinusitis originating from other sources. CaseReport:Illustrating such fact, this report presents the clinical case of a 37-year-old woman referred complaining of pain in the same region where she had extracted her upper right first molar five days before. The intraoral examination revealed the presence of an orifice in the region, suggesting oroantral communication. Imaging exams revealed opacification of the right maxillary sinus and the unexpected presence of a highly radiodense object. With the diagnosis of maxillary sinusitis due to a foreign body established, the surgical approach initially consisted of administering preoperative medication, preceded by access to the maxillary antrum using the Caldwell-Luc technique. The object was found and removed, consisting of a surgical drill. At follow-up there was complete absence of symptoms and complete closure of communication. Conclusion: Cases of odontogenic maxillary sinusitis caused by drill detachment after tooth extraction are fairly uncommon. A thorough clinical evaluation proved to be essential and the Caldwell-Luc access was effective, safe and with good postoperative results, even with the absence of standardized diagnostic and management methods(AU)


Contexto: A sinusite maxilar odontogênica causada por corpo estranho apresenta desafios diagnósticos e terapêuticos devido à sua ocorrência infrequente e características únicas em comparação com sinusites originadas de outras fontes. Relato do Caso: Ilustrando tal fato, este relato apresenta o caso clínico de uma mulher de 37 anos de idade encaminhada com queixa de dor em mesma região que havia extraído o primeiro molar superior direito cinco dias antes. Ao exame intraoral verificou-se a presença de um orifício na região, sugerindo comunicação oroantral. Os exames de imagem revelaram opacificação do SM direito e a inesperada presença de um objeto altamente radiodenso. Com o diagnóstico de sinusite maxilar por corpo estranho estabelecido, a abordagem cirúrgica consistiu inicialmente na administração de medicação pré-operatória, precedida pelo acesso ao antro maxilar através da técnica de Caldwell-Luc. O objeto foi encontrado e removido, consistindo em uma broca cirúrgica. Ao acompanhamento houve ausência completa dos sintomas e total fechamento da comunicação. Conclusão: Casos de sinusite maxilar odontogênica causada por descolamento da broca após extração dentária são bastante incomuns. Uma avaliação clínica minuciosa mostrou-se primordial e o acesso de Caldwell-Luc eficaz, seguro e com bons resultados pós-operatórios, mesmo com as ausências de métodos de diagnóstico e manejo padronizados.(AU)


Subject(s)
Humans , Female , Adult , Surgery, Oral , Maxillary Sinusitis , Oroantral Fistula
2.
Article | IMSEAR | ID: sea-206661

ABSTRACT

The retained of a foreign body during a surgical procedure is defined by the forgetting of a material, left by inattention in the body of the patient during this act. It is a rare event but is responsible for high morbidity and mortality. Authors report a retained foreign body incidentally discovered during a caesarean section. The patient had performed an illegal abortion by endo-uterine instrument which was complicated by uterine perforation five years previously. She was pregnant at 37 weeks and presented to the emergency department for bleeding and diagnosed as placenta previa. The antecedent of abortion had not been informed because it is an illegal act in Madagascar. The plastic instrument was in the broad ligament in contact with the ureter and the uterine artery. Caesarean section, the removal of the catheter and postoperative recovery was uneventful. Foreign body retention remains a malpractice and the diagnosis must be made in the face of chronic pain in patients who have undergone surgery.

3.
Korean Journal of Radiology ; : 541-544, 2016.
Article in English | WPRIM | ID: wpr-13402

ABSTRACT

Many hospitals experience one or more retained surgical instrument events with risk of patient morbidity and medicolegal problems. Identification of retained surgical instrument is important. The radiologists should be familiar with imaging finding of retained surgical instrument. In a 62-year-old female with a retained plastic tube, localized peritoneal infiltration around air-containing tubular structure mimicked acute appendicitis on abdomen computed tomography (CT), one year after laparoscopic cholecystectomy. We reported CT findings of foreign body reaction related to retained Endoloop ligature plastic tube mimicking acute appendicitis.


Subject(s)
Female , Humans , Middle Aged , Abdomen , Appendicitis , Cholecystectomy, Laparoscopic , Foreign Bodies , Foreign-Body Reaction , Ligation , Peritonitis , Plastics