1.
Bauru; s.n; 2017. 143 p. tab, ilus, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-880165

ABSTRACT

A adição de corantes fluorescentes a adesivos odontológicos possibilita a investigação da distribuição espacial desses materiais na interface dente-restauração, utilizando-se a microscopia confocal de varredura a laser (MCVL). A literatura indica falta de padronização na aplicação de agentes fluorescentes com tal finalidade. Esse estudo sistematizou estratégias para a adição de rodamina B (RB) e fluoresceína sódica (FS) a um sistema adesivo convencional de três passos, Adper Scotchbond Multi-Purpose (MP), e um autocondicionante de dois passos, Clearfil SE Bond (SE), considerados "padrão-ouro" na Odontologia. Os objetivos principais foram (a) determinar a menor faixa de concentrações de RB e FS necessária para produzir imagens satisfatórias da interface dentina-adesivo e (b) avaliar o efeito da adição desses corantes sobre algumas propriedades das resinas. Os adesivos foram marcados com RB ou FS em concentrações decrescentes (0,5, 0,1, 0,02 e 0,004 mg/mL) por meio de um método de dispersão semidireto. O comportamento fotofísico/ fluorescente dos adesivos marcados foi investigado por espectroscopia de fotoluminescência e MCVL. Paralelamente, avaliaram-se os adesivos quanto ao grau de conversão (GC) e ao ângulo de contato (AC). Tanto os resultados de GC como os de AC foram submetidos à análise de variância com dois fatores (adesivo e tratamento) com α = 0,05, seguida de teste post-hoc de Tukey. Os máximos comprimentos de onda de emissão e de excitação da RB e da FS foram influenciados pelo meio polimérico e pela concentração de corante de modo geral. A MCVL preliminar de amostras de adesivo polimerizado, realizada sob condições experimentais padronizadas, mostrou que o comportamento fluorescente da RB em MP e SE foi muito semelhante na mesma concentração de corante, mas o mesmo não pôde ser dito do comportamento da FS, que foi notavelmente inferior no adesivo autocondicionante, SE, na concentração mais alta. Em dentina, os adesivos preparados com RB nas concentrações-alvo de 0,1 e 0,02 mg/mL apresentaram fluorescência ótima; já aqueles preparados com 0,004 mg/mL produziram fraco sinal. Adesivos preparados com FS a 0,5 mg/mL apresentaram ótima fluorescência na interface de adesão, enquanto que concentração menor desse corante não produziu sinal suficiente. Padrões morfológicos aparentemente atípicos foram observados na interface de adesão, quando da associação do adesivo SE com o corante FS. A adição de RB e FS nas quatro concentrações indicadas aos adesivos MP e SE não afetou o GC nem o AC em comparação com os grupos de controle correspondentes. Em suma, a RB mostra-se um corante mais versátil que a FS na avaliação morfológica das interfaces dentina-MP e dentina-SE via MCVL. A menor faixa de concentrações de RB nos adesivos MP e SE, na qual é possível produzir imagens satisfatórias das interfaces, situa-se entre 0,1­0,02 mg/mL. Já o corante FS deve ser adicionado a esses adesivos a pelo menos 0,5 mg/mL para produzir níveis de fluorescência satisfatórios na interface de adesão. A não ocorrência de efeitos deletérios sobre a polimerização e a molhabilidade das resinas estabelece uma margem de segurança para a incorporação desses agentes fluorescentes (em concentração ≤ 0,5 mg/mL) nesses sistemas monoméricos.(AU)


The addition of fluorescent dyes to dental adhesives makes it possible to investigate the spatial distribution of such resin-based materials in the tooth-restoration interface, using confocal laser scanning microscopy (CLSM). Literature indicates a lack of standardization on the application of fluorescent agents for this purpose. This work presents strategies for adding rhodamine B (RB) and fluorescein sodium salt (FS) to a three-step etch-and-rinse adhesive system, Adper Scotchbond Multi-Purpose (MP), and a two-step self-etching one, Clearfil SE Bond (SE), both regarded as "gold standard" in restorative dentistry. The main objectives were (a) to determine the lowest range of RB and FS concentrations required to produce suitable images of the dentin-adhesive interface via CLSM and (b) to investigate potential effects of addition of these dyes on some resin properties. The adhesives were labeled with RB or FS at decreasing concentrations (0.5, 0.1, 0.02 and 0.004 mg/mL) by means of a semi-direct dispersion method. The photophysical/fluorescent behavior of the labeled resins was investigated by photoluminescence spectroscopy and by CLSM. The adhesives were also investigated with regards to the degree of conversion (DC) and contact angle (CA). A two-way ANOVA of "adhesive" and "treatment" was conducted on DC and CA separately, followed by Tukey's test. The maximum emission and excitation wavelengths of RB and FS were influenced by the host polymer and the dye concentration in general. The preliminary CLSM of cured adhesive samples, performed with standardized settings, showed that the fluorescent behavior of RB in MP and SE was very similar in the same dye concentration, unlike the behavior of FS, which was lower in the self-etching adhesive for the highest dye concentration. In dentin, the adhesives prepared with RB at the target concentrations of 0.1 and 0.02 mg/mL presented optimal fluorescence; those with 0.004 mg/mL produced poor signal. Adhesives prepared with FS at 0.5 mg/mL presented optimal fluorescence at the bonding interface, whereas lower concentrations of FS did not produce sufficient signal. Atypical morphological features were observed at the bonding interface, when adhesive SE was used with FS. The addition of RB and FS at the four decreasing concentrations to adhesives MP and SE did not affect DC or CA compared to the corresponding controls. In short, RB is more versatile than FS for the morphological characterization of dentin-MP and dentin-SE interfaces via MCVL. The lowest range of RB concentrations in adhesives MP and SE that can produce suitable images of the bonding interface lies between 0.1­0.02 mg/mL. The dye FS should be added to these adhesives at 0.5 mg/mL at least to produce satisfactory fluorescence levels at the bonding interface. Since negative effects on polymerization and wettability of the resins were not observed, the use of RB and FS (in concentration ≤ 0.5 mg/mL) together with MP and SE should be reliable in terms of resin properties.(AU)


Subject(s)
Fluorescein/chemistry , Fluorescent Dyes/chemistry , Resin Cements/chemistry , Rhodamines/chemistry , Analysis of Variance , Ethanol/chemistry , Microscopy, Confocal , Reference Values , Reproducibility of Results , Self-Curing of Dental Resins/methods , Spectrometry, Fluorescence , Spectrophotometry, Infrared
2.
Braz. j. pharm. sci ; 51(3): 745-753, July-Sept. 2015. graf
Article in English | LILACS | ID: lil-766324

ABSTRACT

The present study was planned to investigate the influence of polyethylene glycols (PEGs) on the activity and expression of P-glycoprotein (P-gp). Sub-toxic concentrations of PEGs in Caco-2 cells were determined using the MTT test assay. Then the measurement of Rhodamine-123 (Rho-123) uptake, a P-gp fluorescence substrate, in Caco-2 cells confronting PEG 400 (1% and 2% w/v), PEG 4000 (2% and 4% w/v), PEG 6000 (2% and 4% w/v), PEG 10000 (2% and 4% w/v), PEG 15000 (1% and 2% w/v), and PEG 35000 (2% and 4% w/v) overnight was taken to elucidate whether non-toxic concentrations of PEGs are able to impact P-gp activity. Furthermore, western blotting was carried out to investigate P-gp protein expression. The results showed that PEG 400 at concentrations of 1% (w/v) and 2% (w/v) and PEG 6000 at the concentration of 4% (w/v) are notably capable of blocking P-gp. Based on the obtained results it is concluded that the mentioned excipients could be used to obstruct P-gp efflux transporter in order to increase the bioavailability of co-administered substrate drug.


O presente estudo foi planejado para investigar a influência de polietileno glicóis sobre a atividade e expressão da P- glicoproteína (P-gp) . Concentrações sub-tóxicas de PGPs e em células Caco-2 foram determinadas por meio do ensaio de MTT. Em seguida, efetuou-se a a medida de captura de Rodamina-123 (Rho-123), um substrato fluorescente de P-gp, em células Caco-2, confrontando com PEG 400 (1% e 2% m/v), PEG 4000 (2% e 4% m/v) e PEG 6000 (2% e 4% m /v), PEG 10000 (2% e 4% w/v), PEG 15000 (1% e 2% m/v), e PEG 35000 (2% e 4% m/v). Essa medida foi efetuada durante a noite, para saber se as concentrações não tóxicas de excipientes são capazes de influenciar a actividade da P-gp. Além disso, realizou-se o western blotting para investigar a expressão da proteína P-gp. Os resultados mostraram que o PEG 400, nas concentrações de 1% (m/v) e 2% (m/v), e PEG 6000, na concentração de 4% (m/v) são capazes de bloquear P-gp. Com base nos resultados conclui-se que os excipientes mencionados poderiam ser utilizados para obstruir o efluxo por P-gp, a fim de aumentar a biodisponibilidade de do fármaco co-administrado.


Subject(s)
Polyethylene Glycols/analysis , ATP Binding Cassette Transporter, Subfamily B, Member 1/analysis , Caco-2 Cells , Biological Availability , Rhodamine 123 , Excipients/classification
3.
Eng. sanit. ambient ; 14(1): 129-138, jan.-mar. 2009. graf, tab
Article in Portuguese | LILACS | ID: lil-512053

ABSTRACT

Lagoas de estabilização localizadas em regiões com variações elevadas de temperatura ao longo do dia tendem a apresentar estratificação térmica, um fenômeno que altera o volume útil da lagoa. Neste trabalho, apresentam-se resultados experimentais obtidos em duas lagoas, facultativa e maturação, construídas na região central do estado de São Paulo. O acompanhamento do perfil de temperatura mostrou a ocorrência de estratificação térmica com ciclo nictimeral nas duas lagoas. Os ensaios hidrodinâmicos indicaram comportamento semelhante ao de reatores com mistura completa, com zonas mortas, volume útil de aproximadamente 60 por cento na lagoa facultativa e 30 por cento na lagoa de maturação. Os experimentos corroboraram os resultados teóricos obtidos com o modelo matemático para previsão da estratificação térmica.


Stabilization ponds located in places that present high temperature variations along the day have a tendency to present thermal stratification, a phenomenon that changes the useful volume of the pond. This paper presents experimental results from two stabilization ponds, facultative and maturation, built in the central area of the state of São Paulo, Brazil. The observation of the temperature profile showed the occurrence of thermal stratification with the nictimeral cycle in both ponds. Hydrodynamic tests showed a pattern that resembles the behavior of complete mixing reactors with dead zones, resulting in useful volumes close to 60 percent for the facultative pond and 30 percent for the maturation pond. The experiments confirm the theoretical results obtained based on a mathematical model to predict thermal stratification.

4.
Rev. bras. odontol ; 63(3/4): 171-175, 2006. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-541666

ABSTRACT

Este trabalho investigou a influência da diminuição do eugenol adicionado ao óxido de zinco na disseminação dentinária de compostos provenientes do cimento obturador endodôntico. Cinquenta e dois pré-molares humanos obturados pela técnica da condensação lateral de guta-percha e cimento Endomèthasone, ao qual se adicionou rodamina B (0,2% em peso) e eugenol em concentrações decrescente (100%, 60%, 20%) diluídos ou não em propileno glicol para manter constante a relação pó/líquido dos cimentos experimentais (n=14). Após mensuração digital dos níveis de disseminação do marcador, observou-se proporcionalidade entre o volume de eugenol adicionado e a penetração dentinária de substâncias provenientes do cimento obturador.


Subject(s)
Humans , Dental Cements , Dentin , Eugenol/administration & dosage , Rhodamines , Root Canal Filling Materials , Bicuspid , Zinc Oxide