Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Chinese Journal of Biologicals ; (12): 347-2023.
Article in Chinese | WPRIM | ID: wpr-976125

ABSTRACT

@#Objective To develop and validate size exclusion column-high performance liquid chromatography(SEC-HPLC)for determination of the purity of bulk material of freeze-dried rabies vaccine for human use.Methods Chromatography column TSK-gel G6000PW_(XL)(7.8 mm × 30 cm,13 μm)was used for the determination(column temperature 30 ℃)with mobile phase of 0.1 mol/L PB buffer(pH 7.8)at a flow rate of 0.5 mL/min.The detection wavelength was 280 nm and injection volume was 20 μL.The method was validated for system suitability,specificity,precision and durability and determined for detection limit and quantitation limit,which was applied to analyze bulk material purity of freeze-dried rabies vaccine for human use of 3 batches of Vero cells and 1 batch of human diploid cells.Results The resolution of target protein spectrum peak of bulk material of reference sample and freeze-dried rabies vaccine for human use prepared with two substrates was more than 1.5 with a tailing factor less than 1.5;The blank solvent showed no absorption peak at the position of target protein peak with no interference in the determination;The RSDs of retention time and peak area in precision verification were both less than 2.0%;The quantitative limit was 10 μg/mL,and the detection limit was 4 μg/mL;The reference sample was injected three times continuously at three different detection wavelengths of 278,280 and 282 nm,and the RSDs of retention time and peak area were also less than 2.0%.The purity of 4 batches of freeze-dried rabies vaccine bulk material for human use was all more than 97%.Conclusion The developed SEC-HPLC for determination of the purity of freeze-dried rabies vaccine bulk material for human use showed good specificity,precision and durability,which provided a reliable method for the quality control of human rabies vaccine.

2.
Chinese Journal of Biologicals ; (12): 1235-1241, 2023.
Article in Chinese | WPRIM | ID: wpr-996684

ABSTRACT

@#Objective To optimize and verify the size exclusion chromatography-high performance liquid chromatography(SEC-HPLC) method for the determination of recombinant human growth hormone(rhGH)-Fc immunofusion protein polymer.Methods The multimer content of rhGH-Fc immunofusion protein was detected by SEC-HPLC.The detection conditions(salt concentration,mobile phase pH,flow rate,column temperature and column model) were optimized to observe the separation effect of the target proteins and polymers.The system suitability,specificity,linearity and range,precision,accuracy and limit of quantification of the method were verified.Results The optimized method was to use TSK-gel G2000SW_(x1)column(5 μm,7.8 mm × 300 mm),mobile phase of 50 mmol/L phosphate buffer(pH 6.80),detection wavelength of280 nm,injection volume of 100 μL,flow rate of 0.6 mL/min and column temperature of 45 ℃.The resolution of rhGHFc immunofusion protein and polymer,the theoretical plate number and the tailing factor all met the requirements;the peak time of rhGH-Fc immunofusion protein was the same as that of the control,while the peak time of GH national standard was different from that of the control,and the protein buffer showed no peak;the concentration of rhGH-Fc immunofusion protein was in the range of 0.307~1.842 mg/mL with good linear correlation between the peak area integral value and the injection volume(R~2=0.999 4);the RSD of peak area and purity in repeatability verification were 0.7% and 0.1%,respectively;the RSD of intermediate precision verification was 0.8%;the average recovery rate of accuracy verification was 99.1% with the RSD of 1.9%;the limit of quantification was 6 μg/mL.Conclusion The optimized SEC-HPLC method was used to detect the content of polymer in rhGH-Fc immunofusion protein with improved accuracy,and the column efficiency and separation were in accordance with the relevant requirements of Chinese Pharmacopoeia(Volume Ⅳ,2020edition),which could be used for the detection of polymer content in samples.

3.
Acta Pharmaceutica Sinica ; (12): 1897-2016.
Article in Chinese | WPRIM | ID: wpr-779349

ABSTRACT

The composition and potency of the high temperature (40℃) stress induced size variants of a recombinant humanized monoclonal antibody (rhumAb1) were characterized by means of SEC-HPLC, nonreduced CE-SDS, liquid chromatography coupled with mass spectrometry (LC-MS) and antibody dependent cell-mediated cytotoxicity (ADCC) assay. The molecular masses of the four size variants (SEC-1-SEC-4) separated by SEC-HPLC and seven size variants (NR-1-NR-7) detected by non-reduced CE-SDS were all characterized by LC-MS. The major low molecular weight variants were generated due to the hinge region fragmentation of heavy chain. The hinge region cleavage was found mainly in the Ser221-Cys-Asp-Lys-Thr-His-Thr-Cys228 sequence, in which C222-D223 and H226-T227 were the major cleavage sites. The size variants of rhumAb1, namely dimer and fragments, have significantly reduced ADCC activity in comparison with the intact rhumAb1 drug product. This study provided insights into the stability profiling for rhumAb1 drug product. The study protocols presented here may be applicable to the analytical characterization of other monoclonal antibody-based therapeutic products.

SELECTION OF CITATIONS
SEARCH DETAIL