Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.351
Filter
1.
Braz. j. oral sci ; 23: e241938, 2024. ilus
Article in English | LILACS, BBO | ID: biblio-1532506

ABSTRACT

Aim: To evaluate changes in the surface roughness and morphology of a nanofilled composite following toothbrushing with a whitening (WT) or regular toothpaste (RT), alone or combined with 35% hydrogen peroxide bleaching (HP). Methods: Seventy disc-shaped nanofilled composite (Filtek Z350XT) specimens were randomly divided into groups (n=10): WT, RT, TB (without toothpaste ­ control) or the combinations WT/ HP, RT/HP, TB/HP and HP. All groups underwent toothbrushing simulation (60,000 cycles) and bleaching treatment (4 sessions). Mean surface roughness (Ra, µm) was measured before (T0) and after treatments (TB). Surface morphology was assessed by scanning electron microscopy (SEM) at TB. Mean Ra was analyzed using general mixed models and multiple comparisons by the Tukey-Kramer test (α=5%). Results: HP caused no surface roughness changes on the nanofilled composite after treatment (p>0.05). RT toothbrushing, combined or not with HP, increased the surface roughness (p<0.05). WT and WT/ HP protocols had no effect on the surface roughness of the composite (p>0.05). The nanofilled composite submitted to RT toothbrushing combined with HP (RT/HP) presented substantial surface alterations under SEM, showing deep depressions and round-shaped defects. Toothbrushing with RT combined with the bleaching agent increased exposure of the inorganic fillers. Conclusion: WT toothbrushing, regardless of HP combination, or the single HP protocol had no effect on the surface roughness of the nanofilled composite. However, RT combined with HP negatively affected surface roughness and presented the most noticeable surface changes among groups


Subject(s)
Tooth Bleaching , Toothpastes , Microscopy, Electron, Scanning , Composite Resins , Hydrogen Peroxide
2.
Braz. dent. sci ; 27(1): 1-7, 2024. ilus, tab
Article in English | LILACS, BBO | ID: biblio-1532450

ABSTRACT

Objective: The aim of this study was to determine if SEM used with imaging software could be used to quantitatively determine the extent of dentine roughness due to tooth-brushing. Material and methods: Flat, polished dentine surfaces were subjected to 25,000 cycles of simulated tooth-brushing at 2 strokes per second with a load of 200 g. At the end of the brushing cycle, dentine surfaces were first assessed using profilometry and then subjected to SEM analysis. Ra (average roughness) readings were obtained for profilometric assessment. Using imaging software, the horizontal distance between adjacent characteristic grooves noted on micrographs was measured, ensuring that the middle of each crest of the associated groove was used as the reference point, the Crest-to-Crest distance (C-C distance). These two parameters were examined statistically for correlation. Results: When Spearman Rank tests were utilized the correlation between average Ra and crest to crest measurements was 0.709 (p <0.01). The Bland Altman plot, however, showed poor agreement between the two test parameters. Conclusion: Further work is needed to validate the use of this methodology in the quantitative assessment of tooth surface loss due to abrasion (AU)


Objetivo: O objetivo deste estudo foi determinar se o MEV usado com software de imagem poderia ser usado para determinar quantitativamente a extensão da rugosidade da dentina devido à escovação dentária. Material e Métodos: Superfícies dentinárias planas e polidas foram submetidas a 25.000 ciclos de escovação dentária simulada a 2 movimentos por segundo com uma carga de 200g. No final do ciclo de escovação, as superfícies dentinárias foram primeiro avaliadas por perfilometria e depois submetidas à análise MEV. Leituras de Ra (rugosidade média) foram obtidas para avaliação perfilométrica. Utilizando um software de imagem, foi medida a distância horizontal entre sulcos característicos adjacentes observados nas micrografias, garantindo que o meio de cada crista do sulco associado fosse usado como ponto de referência, a distância crista a crista (distância CC). Esses dois parâmetros foram examinados estatisticamente para correlação. Resultados: Quando foram utilizados os testes de Spearman Rank, a correlação entre a média de Ra e as medidas de crista a crista foi de 0,709 (p<0,01). O gráfico de Bland Altman, no entanto, mostrou fraca concordância entre os dois parâmetros de teste. Conclusão: Mais trabalhos são necessários para validar o uso desta metodologia na avaliação quantitativa da perda da superfície dentária devido à abrasão(AU)


Subject(s)
Surface Properties , Tooth Abrasion , Toothbrushing , Microscopy, Electron, Scanning , Dentin
3.
São Paulo med. j ; 142(4): e2023113, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1536910

ABSTRACT

ABSTRACT BACKGROUND: To the best of our knowledge, this is the first study to evaluate the effectiveness of specific concentrations of antibiofilm agents, such as N-acetyl cysteine (NAC), rifampicin, and ozone, for the treatment of pan-resistant Klebsiella pneumoniae (PRKp). OBJECTIVES: We evaluated the effectiveness of antibiofilm agents, such as NAC, rifampicin, and ozone, on biofilm formation in PRKp at 2, 6, 24, and 72 h. DESIGN AND SETTING: This single-center experimental study was conducted on June 15, 2017, and July 15, 2018, at Istanbul Faculty of Medicine, Istanbul University, Turkey. METHODS: Biofilm formation and the efficacy of these agents on the biofilm layer were demonstrated using colony counting and laser-screened confocal microscopy. RESULTS: NAC at a final concentration of 2 μg/mL was administered to bacteria that formed biofilms (24 h), and no significant decrease was detected in the bacterial counts of all isolates (all P > 0.05). Rifampicin with a final concentration of 0.1 μg/mL was administered to bacteria that formed biofilm (24 h), and no significant decrease was detected in bacterial count (all P > 0.05). Notably, ozonated water of even 4.78 mg/L concentration for 72 h decreased the bacterial count by ≥ 2 log10. CONCLUSION: Different approaches are needed for treating PRKp isolates. We demonstrate that PRKp isolates can be successfully treated with higher concentrations of ozone.

4.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 216-222, 2024.
Article in Chinese | WPRIM | ID: wpr-1006866

ABSTRACT

Objective@#To explore an accurate method to obtain an intraoral model of patients with specific limited mouth opening (microstomia) due to systemic scleroderma.@*Methods@#This study followed medical ethics, and informed consent has been obtained from patients. A case of Ken's Type I mandibular dentition defect scleroderma with limited mouth opening was addressed with digital technology as the leading method combined with the traditional impression method of segmental impression. Individual trays were made based on the patient's left and right mandibular dentition, and segmented molds were obtained. Simultaneously, intraoral scanning was performed to obtain the morphological data of both the soft and hard tissues of the upper and lower mandibles. After each part of the model was obtained, the mandibular model was scanned and digitally aligned to form the final denture model, and the final removable partial denture was designed and made by computer aided design/computer aided manufacturing (CAD/CAM) technology. At the same time, combined with the literature, the diagnosis and treatment of removable partial denture in patients with limited mouth opening were retrospectively analyzed.@*Results@#The denture was well retained and achieved a good repair effect. The patients expressed satisfaction with the mastication efficiency and other functions of the denture. The findings of the literature review show that the integration of digital technology with the traditional impression method, along with computer fitting, can accurately obtain the patient's oral model and facilitate successful follow-up repairs. However, when the anterior mandibular dentition of the patient is absent, the margin of error is increased in this procedure, which deserves further exploration.@*Conclusion@#Utilizing digital technology as the leading method, combined with the traditional impression method of segmental impression, for the repair of dental defects in patients with limited mouth opening, has proven to be effective. Thus, patients report a positive medical experience with high satisfaction, indicating that this approach is worthy of clinical promotion.

5.
Chinese Journal of Experimental Traditional Medical Formulae ; (24): 175-182, 2024.
Article in Chinese | WPRIM | ID: wpr-1005267

ABSTRACT

ObjectiveTo explore the scientific connotation of fried charcoal survivability of Lonicerae Japonicae Flos(LJF) by analyzing the correlation between the color change and the intrinsic components during the processing of LJF Carbonisata(LJFC), and taking pH, charcoal adsorption and microscopic characteristics as indexes. MethodLJFC samples with different degrees of processing were prepared according to the stir-frying time of 0.0, 1.5, 3.0, 4.5, 6.0, 7.5, 9.0, 10.5 min(numbered S1-S8), and the contents of gallic acid, chlorogenic acid, cryptochlorogenic acid, rutin, luteoloside, isochlorogenic acid A and isochlorogenic acid C were determined by high performance liquid chromatography(HPLC), and the L*(brightness), a*(red-greenness) and b*(yellow-blueness) of LJFC samples with different degrees of processing were determined by spectrophotometer, and the correlation analysis and principal component analysis(PCA) between the contents of seven representative components and the color of the samples were carried out by SPSS 26. 0 and SIMCA-P 14.1. Then pH, adsorption force and characteristic structure of different samples of LJFC were detected and the processing pattern of LJFC was analyzed. ResultThe results of quantitative analysis revealed that the contents of luteoloside, rutin, chlorogenic acid and isochlorogenic acid A gradually decreased, and the contents of cryptochlorogenic acid, isochlorogenic acid C and gallic acid firstly increased and then decreased. The L* and b* of the sample powders decreased, and a* showed a trend of increasing and then decreasing. The L* and b* were positively correlated with the contents of chlorogenic acid, rutin, luteoloside, isochlorogenic acid A, b* was positively correlated with the content of gallic acid, and a* was positively correlated with the contents of cryptochlorogenic acid and isochlorogenic acid C. PCA revealed that samples could be clearly divided into 3 groups, S1-S2 as one group, S3-S5 as one group, and S6-S8 as one group, with S3 having the highest score. The results of regression analysis showed that only isochlorogenic acid C could be used to predict the contents of components by colorimetric values combined with regression equations. Physicochemical analysis showed that pH of LJFC increased with the increase of degree of charcoal stir-frying, while adsorption force showed a tendency of increasing and then decreasing, with the highest adsorption force in the S5 sample, and the non-glandular hairs, calcium oxalate clusters and pollen grains had a varying degree of decreasing with the deepening of processing degree, and the microstructures of S6-S8 samples were obviously charred with pollen grains almost invisible. ConclusionThe changes in chemical composition and color characteristics of LJFC during the processing have certain correlations, combined with the changes in physicochemical properties, S5 sample is found to be the optimal processed products, which can provide a reference for the processing standardization and quality evaluation of LJFC, and enrich the scientific connotation of fried charcoal survivability of LJF.

6.
Journal of Public Health and Preventive Medicine ; (6): 17-20, 2024.
Article in Chinese | WPRIM | ID: wpr-1016404

ABSTRACT

Objectives To analyze the spatial and temporal aggregation of multidrug resistant pulmonary tuberculosis (MDR-TB) incidence in Nanning at the township / street scale from 2017 to 2021, to explore the spatial and temporal characteristics of the spread of MDR-TB in Nanning, and to provide a scientific reference basis for the health administrative departments to achieve the precise implementation of MDR-TB prevention and control. Methods Based on the data of MDR-TB cases in Nanning from 2017 to 2021, the spatial-temporal scanning analysis software SaTScan v9.7 was used to retrospectively detect and analyze the areas where MDR-TB cases gathered. Results Through simple spatial scanning analysis, it was found that there were three first-class aggregation areas (the aggregation center was Fujiayuan Street, Jiangnan District, 2017, Xinyang Street, Xixiangtang District, 2019, and Zhonghe Town, Yongning District, 2020), and one second-class aggregation area (the aggregation center was Jinchai Town, Mashan County, 2020). Simple time scanning showed that the clustering occurred from May 2019 to December 2020. Temporal and spatial aggregation analysis showed that Xinyang Street in Xixiangtang District was the center of the first-class aggregation area, Zhonghe Town in Yongning District was the center of the second-class aggregation area, and Jinchai Town in Mashan County was the center of the third-class aggregation area. Conclusion The multidrug resistant pulmonary tuberculosis epidemic in Nanning is distributed in an aggregated manner, especially in Xinyang Street, Xixiangtang District, which has the highest spatial and temporal aggregation. It is necessary to focus on and take regional prevention and control measures to control the epidemic.

7.
Braz. j. biol ; 842024.
Article in English | LILACS-Express | LILACS, VETINDEX | ID: biblio-1469374

ABSTRACT

Abstract The present study aimed to investigate the beneficial of prepared black rice anthocyanins nano-composite (An-AgNps) against hepatotoxicity induced by methotrexate (MTX) in rats. Anthocyanins nano-composite was prepared by silver as the metallic ion reduction and were characterized by IR and SEM. The rats in our experiment were divided into five groups. Serum lipid profile, serum transaminases (ALT and AST), ALP, LDH, TBA, GSH and SOD were examined. The results show that SEM of An-AgNps has average particle size from 70 to 130nm. In the group treated with MTX; TC, TG, LDL-c, ALT, AST, ALP, LDH and TBA levels were significantly (P0.05) increased than NC, while, HDL-c, SOD and GSH levels were significantly (P0.05) decreased. On the other hand, An-AgNps + MTX treated groups were reversed the levels of all biomarkers similar to NC. In conclusion, the results show that An-AgNps has a protective effect on MTX-induced hepatotoxicity and oxidative stress.


Resumo O presente estudo teve como objetivo investigar o benefício de nanocompósito de antocianinas de arroz preto preparado (An-AgNps) contra a hepatotoxicidade induzida por metotrexato (MTX) em ratos. O nanocompósito de antocianinas foi preparado a partir da prata por meio da redução do íon metálico e caracterizado por IR e SEM. Os ratos em nosso experimento foram divididos em cinco grupos, e foram examinados o perfil lipídico sérico, as transaminases séricas (ALT e AST), ALP, LDH, TBA, GSH e SOD. Os resultados mostram que SEM de An-AgNps tem tamanho médio de partícula de 70 a 130 nm. No grupo tratado com MTX, os níveis de TC, TG, LDL-c, ALT, AST, ALP, LDH e TBA aumentaram significativamente (P 0,05) do que NC, enquanto os níveis de HDL-c, SOD e GSH diminuíram significativamente (P 0,05). Por outro lado, nos grupos tratados com An-AgNps + MTX, foram revertidos os níveis de todos os biomarcadores semelhantes ao NC. Em conclusão, os resultados mostram que o An-AgNps tem um efeito protetor contra a hepatotoxicidade induzida pelo MTX e o estresse oxidativo.

8.
Rev. nav. odontol ; 50(2): 5-14, 20232010.
Article in Portuguese, English | LILACS-Express | LILACS | ID: biblio-1518550

ABSTRACT

Considerando o uso de brocas para remoção da resina residual após descolagem do braquete e a possibilidade de injúrias à superfície do esmalte após o uso dessas brocas, este trabalho teve como objetivo realizar um estudo experimental, para avaliar a variação do aspecto superficial do esmalte de forma qualitativa, por meio da avaliação com imagens topográficas do esmalte dentário, utilizando-se a Microscopia Eletrônica de Varredura (MEV), a qual permitiu ilustrar e avaliar a superfície do esmalte após a fase de polimento final, realizada por dois métodos: taça de borracha ou escova Robinson. Foram utilizados 25 dentes pré-molares humanos, obtidos a partir de exodontias em pacientes que procuraram voluntariamente o curso de Residência em Cirurgia da Clínica Odontológica Universitária da Universidade Estadual de Londrina. Os dentes foram divididos em quatro grupos: A, B, C e D, contendo 6 dentes cada, de acordo com as brocas utilizadas para a remoção do remanescente adesivo e o polimento escolhido, além de um dente como "controle". Foi avaliada a rugosidade superficial do esmalte após a remoção da resina e a superfície do esmalte após o polimento com as duas opções apresentadas. Os resultados mostraram que, por observação e inspeção, as brocas removeram a resina residual de todos os dentes, porém, causaram riscos e ranhuras, como evidenciado nas imagens em MEV. Concluiu-se que não houve diferença estatística entre os métodos de polimento e que ambos foram importantes para a redução das marcas abrasivas, proporcionando uma superfície mais lisa do esmalte.


Considering the use of specific burs to remove residual resin after bracket debonding and the possibility of injuries to the dental enamel after using these burs, this study aimed to verify the variation in the enamel surface appearance in a qualitative way and evaluation with topographic images of the dental enamel. The use of Scanning Electron Microscopy (SEM) allowed to illustrate and evaluate the enamel surface after the final polishing phase using two methods: rubber cup or Robinson brush. Twenty-five human premolar teeth were obtained from extractions in patients who voluntarily sought the Oral Maxillofacial Surgery Residency at the Dental School from the State University of Londrina; the teeth were divided into four groups A, B, C and D containing 6 teeth each according to the burs used to remove the remaining adhesive and the chosen polishing, in addition to one tooth as a "control". Dental enamel surface roughness was evaluated after resin removal and enamel surface after polishing with the two methods presented. The results showed that by observation and inspection, the burs removed residual resin from all teeth, however, caused scratches and grooves as evidenced in the SEM images. Based on the results, there was no statistical difference between the polishing methods, and both were important for the reduction of abrasive marks and provided a smoother enamel surface.

9.
Indian J Ophthalmol ; 2023 Sep; 71(9): 3270
Article | IMSEAR | ID: sea-225253

ABSTRACT

Background: Ophthalmic dirofilariasis is an uncommon zoonotic parasitic infection caused by species of Dirofilaria, a dog tapeworm that is transmitted to human by mosquitoes. Man is a dead?end host for the parasite. Ophthalmic involvement is rare and includes periorbital, subconjunctival, subtenon, and intra?ocular involvement. We report the removal of a subconjunctival worm and identification by light microscopy (LM) and scanning electron microscopy (SEM). Purpose: A 62?year?old female presented with complaints of redness, discharge, and foreign body sensation with difficulty in opening eyes in the left eye for the last 3 days. The patient is a non?vegetarian. On examination, her best corrected visual acuity in both eyes was 20/20. On slit lamp examination, there was a long, thin, round, coiled white subconjunctival live worm in the left eye superiorly. The rest of anterior segment evaluation, intra?ocular pressure, and fundus was normal in both eyes. The parasite was removed under local anesthesia from subconjunctival space [Video]. External surface morphology under LM revealed fine transverse cuticular striations with tapered cephalic and caudal ends. Uterus was long and coiled with indistinguishable masses inside. The finding was also confirmed by SEM. Synopsis: A subconjuctival parasite was removed and identified as Dirofilaria repens by characteristic LM and SEM findings. Highlight: Dirofilaria species may lodge in many tissues of human bodies including eye and adnexa. Dirofilaria is a natural parasite of carnivorous animals, mostly dogs, cats, and foxes.[1] The most common mode of transmission to human is usually by bite of mosquitoes like Culex and Aedes, which are considered as vectors, and it is often thought that parasitemia is because of accidental conduction.[1] Simple surgical removal of the worm is curative. After removal, the worm should be visualized directly under LM. All the internal structures of the transparent worm could be seen and compared with those under SEM.

10.
Odovtos (En línea) ; 25(2)ago. 2023.
Article in English | LILACS-Express | LILACS | ID: biblio-1448738

ABSTRACT

The aim of this study was to evaluate the whitening and abrasion effects of dentifrices containing different whitening agents on artificially stained and unstained enamel. 160 human dental enamel discs were distributed into four groups according to the type of dentifrices applied on them (n=40): Group I, non-whitening dentifrice (control group); Group II, dentifrice containing charcoal; Group III, dentifrice containing blue covarine; Group IV, dentifrice containing hydrogen peroxide. Half of the specimens in each group were immersed in coffee solution. Color measurements were evaluated from stained and unstained specimens before and after brushing by a spectrophotometer. The surface roughness of each unstained specimen was analyzed using a profilometer after the brushing and bleaching. The surface of one randomly selected specimen from each group was observed using a scanning electron microscope (SEM). Statistical analysis of the color change was performed using the Kruskal-Wallis test. The one-way ANOVA was used to evaluate surface roughness. Group III provided significantly higher recovery on ΔE00 values than other groups on the unstained enamel (p<0.05). Group IV showed significantly the highest ΔE00 values on stained enamel (p<0.05) and also Group IV showed the highest surface roughness values (p<0.05), SEM revealed a more irregular surface in groups III and IV. It can be stated that dentifrice containing blue covarine is both an effective and a safe way to provide whiter teeth with routine home tooth brushing.


El objetivo de este estudio fue evaluar los efectos de blanqueamiento y abrasión de los dentífricos que contienen diferentes agentes blanqueadores en el esmalte teñido y no teñido artificialmente. Se distribuyeron 160 discos de esmalte dental humano en cuatro grupos según el tipo de dentífrico aplicado sobre ellos (n=40): Grupo I, dentífrico no blanqueador (grupo control); Grupo II, dentífrico que contiene carbón vegetal; Grupo III, dentífrico que contiene azul; Grupo IV, dentífrico que contiene peróxido de hidrógeno. La mitad de los especímenes de cada grupo se sumergieron en una solución de café. Las mediciones de color se evaluaron a partir de especímenes teñidos y no teñidos antes y después del cepillado con un espectrofotómetro. La rugosidad de la superficie de cada muestra sin teñir se analizó utilizando un perfilómetro después del cepillado y del clareamiento. La superficie de un espécimen seleccionado al azar de cada grupo se observó utilizando un microscopio electrónico de barrido (MEB). El análisis estadístico del cambio de color se realizó utilizando la prueba de Kruskal-Wallis. Se utilizó el ANOVA para evaluar la rugosidad de la superficie. El grupo III proporcionó una recuperación significativamente mayor en los valores de ΔE00 que otros grupos en el esmalte no teñido (p<0,05). El Grupo IV mostró significativamente los valores más altos de ΔE00 en el esmalte teñido (p<0.05) y también el Grupo IV mostró los valores más altos de rugosidad superficial (p<0.05), el análisis en MEB reveló una superficie más irregular en los grupos III y IV. Se puede afirmar que el dentífrico que contiene azul es una forma efectiva y segura de proporcionar dientes más claros con el cepillado de rutina en el hogar.

11.
Odovtos (En línea) ; 25(2)ago. 2023.
Article in English | LILACS-Express | LILACS | ID: biblio-1448740

ABSTRACT

The first objective of this research was to evaluate the effectiveness of XP-Endo Finisher on dentinal tubule penetration of irrigation solution using confocal laser scanning microscopy. The main purpose of this research was to compare the effect of cold lateral condensation, continuous wave obturation and core-carrier based techniques on sealer penetration. Sixty mandibular premolars were prepared and allocated into two experimental groups (n=30) as the final irrigation technique and obturation technique experiment. In the final irrigation technique experiment, final irrigation was performed with XP-Endo Finisher, passive ultrasonic irrigation (PUI) and conventional needle irrigation (CNI) (n=10). The roots in the obturation technique experiment were also assigned into 3 groups and obturated with cold lateral condensation, continuous-wave obturation and core-carrier techniques (n=10). The most effective activation method, which emerged as a result of the first part of this study, was used as the final irrigation method in the obturation technique experiment. Then, all roots were sectioned in 1-mm-thick slices at 3mm from the apex for scanning. In terms of depth and percentage of material penetration, CNI exhibited significantly the lowest values and no significant difference was found between others. Also, there was no significant difference among obturation methods. In conclusion, XP-Endo Finisher and PUI are more effective than CNI on irrigant penetration. Sealer penetration into dentinal tubules is independent of obturation techniques.


El objetivo principal de esta investigación fue evaluar la eficacia de XP- Endo Finisher en la penetración de la solución de irrigación en los túbulos dentinarios mediante microscopía de láser confocal. Se prepararon sesenta premolares mandibulares y se distribuyeron en dos grupos experimentales (n=30) según el tipo de método de evaluación utilizado. En el experimento de la técnica de irrigación final, la irrigación final se realizó con XP-Endo Finisher, irrigación ultrasónica pasiva (PUI) e irrigación con aguja convencional (CNI) (n=10). Las raíces en el experimento de la técnica de obturación también se asignaron en 3 grupos y se obturaron con técnicas de condensación lateral fría, obturación de onda continua y portador de núcleo (n=10). El método de activación más eficaz, que surgió como resultado de la primera parte de este estudio, se utilizó como método de irrigación final en el experimento de la técnica de obturación. Luego, todas las raíces se seccionaron en muestras de 1mm de espesor. En términos de profundidad y porcentaje de penetración del material, CNI exhibió significativamente los valores más bajos y no se encontraron diferencias significativas entre los demás. Además, no hubo diferencias significativas entre los métodos de obturación. En conclusión, XP-Endo Finisher y PUI son más efectivos que CNI en la penetración del irrigante. La penetración del sellador en los túbulos dentinarios es independiente de las técnicas de obturación.

12.
Int. j. morphol ; 41(4): 1219-1227, ago. 2023. ilus
Article in English | LILACS | ID: biblio-1514335

ABSTRACT

SUMMARY: In this study we describe the functional morphology of Cornu aspersum (Helix aspersa), spermatozoa using light, scanning (SEM) and transmission electron (TEM) microscopies. The studies were performed with sperm located in the frozen hermaphroditic duct. Our results showed that the head presents an elongated conical shape slightly coiled in a corkscrew, with the nucleus partially covered by an acrosome, where an apical vesicle is located at the lateralized apex. This peculiar shape suggests the helical displacement movement of the spermatozoa. The head and the nucleus are slightly larger size compared to those of other gastropod species. The intermediate tract is surrounded by a mitochondrial complex and a glycogen helix. The glycogen helix is coiled helically along the intermediate tract, presenting at least five twists of glycogen helices. The complexity of both the mitochondrial complex and the glycogen helix suggests a high metabolic consumption considering the long period of time until fertilization occurs. Our findings on the detailed characterization of Cornu aspersum spermatozoa, obtained from a frozen hermaphroditic duct can contribute to a better understanding of the functional morphology of sperm and serve as a reference for future studies.


En este estudio describimos la morfología funcional de Cornu aspersum (Helix aspersa), espermatozoides utilizando microscopías de luz, barrido (SEM) y electrónica de transmisión (TEM). Los estudios se realizaron con espermatozoides localizados en el conducto hermafrodita congelado. Nuestros resultados mostraron que la cabeza presenta una forma cónica alargada ligeramente enrollada en un tirabuzón, con el núcleo parcialmente cubierto por un acrosoma, donde se ubica una vesícula apical en el ápice lateralizado. Esta peculiar forma sugiere el movimiento de desplazamiento helicoidal de los espermatozoides. La cabeza y el núcleo son de un tamaño ligeramente mayor en comparación con los de otras especies de gasterópodos. El tracto intermedio está rodeado por un complejo mitocondrial y una hélice de glucógeno. La hélice de glucógeno se enrolla helicoidalmente a lo largo del tracto intermedio, presentando al menos cinco giros de hélices de glucógeno. La complejidad tanto del complejo mitocondrial como de la hélice de glucógeno sugiere un alto consumo metabólico considerando el largo período de tiempo hasta que ocurre la fecundación. Nuestros hallazgos sobre la caracterización detallada de los espermatozoides de Cornu aspersum, obtenidos de un conducto hermafrodita congelado, pueden contribuir a una mejor comprensión de la morfología funcional de los espermatozoides y servir como referencia para futuros estudios.


Subject(s)
Animals , Snails , Spermatozoa/ultrastructure , Spermatozoa/physiology , Microscopy, Electron, Scanning , Cryopreservation , Microscopy, Electron, Transmission , Hermaphroditic Organisms
13.
Odovtos (En linea) ; 25(1)abr. 2023.
Article in English | LILACS, SaludCR | ID: biblio-1422197

ABSTRACT

This study evaluated selected structural and physical properties, such as degree of conversion (DC), Vickers hardness (VHN), and compression strength (CS), of three new dual-cure bulk-fill resin-based composites (RBCs; ACTIVA, HyperFIL, and Fill-Up) and compared them to those of a conventional RBC (Filtek Z250) at three clinically relevant depths. Samples (n=180) were prepared in three depths (2,4, and 6mm). Fourier-transform infrared spectroscopy (FTIR) analysis and VHN and CS tests were performed. The DC value was calculated by considering the relative change in the aliphatic C=C peaks. The fractured surfaces of representative samples were characterized using scanning electron microscopy (SEM). Data were statistically evaluated using two-way analysis of variance and post hoc Bonferroni tests (p<0.05). According to the VHN results, Filtek Z250 showed the highest bottom/top hardness ratio (97.94±1.01) at 2mm thickness and ACTIVA showed the lowest bottom/top hardness ratio (43.48±5.64) at 6mm thickness (p<0.001). According to the FTIR results, the DC decreased with increasing thickness in all materials (p<0.05). Filtek Z250 showed the highest (301±12.4 MPa) and ACTIVA exhibited the lowest (232±17.2 MPa) CS values at 2mm thickness (p<0.05). The lowest CS values were obtained for ACTIVA, and the highest values were obtained for Filtek Z250 for samples with thicknesses of 4 and 6mm, respectively (p<0.05). The structural features of restorative composites, such as the resin chemistry and filler type and content, and the operational parameters (i.e., material thickness and curing conditions) strongly affect crosslinking reactions and thus the DC, VHN, and CS values.


Este estudio evaluó propiedades físicas y estructurales, como el grado de conversión (DC), la dureza Vickers (VHN) y la resistencia a la compresión (CS), de tres nuevos compósitos a base de resina de curado dual tipo bulk (RBC; ACTIVA , HyperFIL y Fill-Up) y los comparó con los de una resina compuesta convencional (Filtek Z250) en tres profundidades clínicamente relevantes. Se prepararon muestras (n=180) en tres profundidades (2,4 y 6mm). Se realizaron análisis de espectroscopia infrarroja por transformada de Fourier (FTIR) y pruebas VHN y CS. El valor de DC se calculó considerando el cambio relativo en los picos alifáticos C=C. Las superficies fracturadas de muestras representativas se caracterizaron mediante microscopía electrónica de barrido (MEB). Los datos se evaluaron estadísticamente mediante análisis de varianza de dos vías y pruebas post hoc de Bonferroni (p<0,05). De acuerdo con los resultados de VHN, Filtek Z250 mostró la relación de dureza inferior/superior más alta (97,94±1,01) con un espesor de 2mm y ACTIVA mostró la relación de dureza inferior/superior más baja (43,48±5,64) con un espesor de 6mm (p<0,001). De acuerdo con los resultados de FTIR, la DC disminuyó al aumentar el espesor en todos los materiales (p<0,05). Filtek Z250 mostró los valores de CS más altos (301±12,4 MPa) y ACTIVA los más bajos (232±17,2 MPa) a 2mm de espesor (p<0,05). Los valores más bajos de CS se obtuvieron para ACTIVA y los valores más altos para Filtek Z250 para muestras con espesores de 4 y 6mm, respectivamente (p<0,05). Las características estructurales de las resinas compuestas de restauración, como la química; además del tipo y contenido del relleno, y los parámetros operativos (es decir, el espesor del material y las condiciones de curado) afectan en gran medida las reacciones de interacción química y, por lo tanto, los valores de DC, VHN y CS.


Subject(s)
Microscopy, Electron, Scanning , Composite Resins/analysis , Compressive Strength
14.
Article | IMSEAR | ID: sea-222451

ABSTRACT

Background: The laser therapy has been used as an adjuvant for conventional periodontal disease as they exhibit a bactericidal effect on scaling and root planning by its thermal and photo disruptive effects on the pathogens. This study focuses on the structural and compositional changes induced on the root surfaces of teeth following diode laser (DL) application with increasing quantum of exposure time. Objective: The objective of this study was to evaluate the structural and compositional changes on the root surface of extracted human permanent teeth after application of DLs (810 nm) with varying time interval. Materials and Methods: Twenty samples of single?rooted periodontally compromised extracted teeth were utilized for this study. Root planning was done and the roughness caused by the instrumentation was measured using profilometric analysis. Then, the samples were divided into four groups, with DL application time: Group 1 – laser application for 15 s, Group 2 – laser application for 30 s, Group 3 – laser application for 45 s, and Group 4 – laser application for 60 s. A scanning electron microscope was used to examine the cemental surface and energy?dispersive X?ray analysis software assesses the compositional changes of the teeth in each group. Results: This study reveals that on exposure of DL (810 nm) on the root surface when time of exposure increases, there were relative increases in surface irregularities and charring. There were significant changes in the chemical composition of the tooth surface.

15.
Braz. dent. j ; 34(1): 45-51, Jan.-Feb. 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1420579

ABSTRACT

Abstract Considering the side effects in the oral cavity and dental structures of radiotherapy (RDT) for head and neck cancer, this study aimed to evaluate the effects of RDT on the root dentin concerning the obliteration of dentinal tubules, the inorganic composition of intra-radicular dentin, and the integrity of collagen fibers. Thirty human canines were selected from a biobank and randomly divided into two groups (n=15). The samples were sectioned buccolingually, and a hemisection was used for structural analysis by scanning electron microscopy (SEM) and energy-dispersive X-ray spectrometer (EDS). Low-vacuum SEM images were obtained at 2000-x magnification to observe the obliteration of the dentinal tubules. Moreover, compositional evaluation was performed using EDS. After RDT, the SEM and EDS analyses were repeated using the same methodology. RDT was applied fractionally at 2 Gy per day, 5 days per week, for 7 weeks, resulting in a total dose of 70 Gy. The collagen integrity of the irradiated and non-irradiated samples was analyzed using Masson's trichrome and picrosirius red staining polarization microscopy. Samples subjected to RDT exhibited dentinal tubule obliteration (p < 0.001); low integrity of type I and III collagen fibers (p < 0.05); compositional reduction of calcium (p = 0.012), phosphorus (p = 0.001), and magnesium (p < 0.001); an increased Ca/P ratio (p < 0.001). RDT affects the structure of dentinal tubules, the inorganic composition of intra-radicular dentin, and the collagen fiber integrity in the root dentin, which may interfere with the effectiveness and durability of dental procedures.


Resumo Considerando os efeitos colaterais na cavidade oral e estruturas dentárias da radioterapia (RDT) para o câncer de cabeça e pescoço, este estudo teve como objetivo avaliar os efeitos da RDT sobre a dentina radicular quanto à obliteração dos túbulos dentinários, a composição inorgânica da dentina intra-radicular e a integridade das fibras colágenas. Trinta caninos humanos foram selecionados de um biobanco e divididos aleatoriamente em dois grupos (n=15). As amostras foram seccionadas no sentido vestíbulo-lingual, e uma hemissecção foi utilizada para análise estrutural por microscopia eletrônica de varredura (MEV) e espectrômetro de raios X de dispersão de energia (EDS). Imagens de MEV de baixo vácuo foram obtidas com aumento de 2500x para observar a obliteração dos túbulos dentinários. Além disso, a avaliação composicional foi realizada usando EDS. Após a RDT, as análises em MEV e EDS foram repetidas usando a mesma metodologia. A RDT foi aplicada fracionada a 2 Gy por dia, 5 dias por semana, durante 7 semanas, resultando em uma dose total de 70 Gy. A integridade do colágeno das amostras irradiadas e não irradiadas foi analisada usando microscopia de polarização de coloração com tricrômio de Masson e picrosirius red. As amostras submetidas a RDT apresentaram obliteração dos túbulos dentinários (p < 0,001); baixa integridade das fibras colágenas tipo I e III (p < 0,05); redução composicional de cálcio (p = 0,012), fósforo (p = 0,001) e magnésio (p < 0,001); e uma relação Ca/P aumentada (p < 0,001). A RDT afeta a estrutura dos túbulos dentinários, a composição inorgânica da dentina intra-radicular e a integridade das fibras colágenas na dentina radicular, o que pode interferir na eficácia e durabilidade dos procedimentos odontológicos.

16.
Braz. dent. sci ; 26(3): 1-13, 2023. ilus, tab
Article in English | LILACS, BBO | ID: biblio-1444656

ABSTRACT

Objective: this double-blind randomized clinical trial evaluate the clinical performance of Thermo-Viscous Bulk Fill composite, Self-Adhesive Flowable composite, and Filtek Bulk Fill Composites restorations in Class I cavities over a period of 18 months. Material and Methods: twenty individuals between the ages of 30 and 45 participated in this research. Each patient should have at least three occlusal Class I carious lesions on their molars. They were dispersed at random, with n=20 teeth representing each tested material. Group I (Futurabond M+ and VisCalor Bulk Fill which heated in a viscolar dispenser at 68 °C for 30s and placed in a 4 mm thickness), Group II (Fusio Liquid Dentin self-adhesive composite which put in a thin layer (1mm increment)), and Group III (Single Bond Universal and Filtek Bulk Fill Posterior composite which applied in 4 mm thickness without heating). Using (USPHS) criteria, all restorations were assessed clinically at baseline, 6 months, 12 months, and 18 months. Using an inverse replica, the marginal seal of the investigated restorations was further evaluated under SEM. Statistical analysis was performed with Chi-square test for all USPH parameters. Results: the three tested groups recorded a one hundred percent retention rate after 18 months follow up period. Concerning marginal adaptation, marginal discoloration, anatomical form, surface texture, and color matching, there was a significant difference (p˂0.05) between the three tested groups after 12 & 18 months. After 12 & 18 months, SEM analysis of the marginal seal revealed a statistically significant difference between the three groups. Conclusion: Bulk fill resin composite restorations showed satisfactory acceptable clinical performance after 18 months of clinical service compared to self-adhesive flowable composites, and Viscalor Bulk Fill composite demonstrated excellent results with considerable changes in marginal integrity as a consequence of thermal viscous technology and increased adaptability of restorations toward cavity walls and margins (AU)


Objetivo: este ensaio clínico randomizado duplo-cego avaliou o desempenho clínico de restaurações de resina Bulk Fill Termo-Viscosa, resina autoadesiva Flowable e Filtek Bulk Fill Composites em cavidades Classe I durante um período de 18 meses. Material e Métodos: 20 indivíduos com idade entre 30 e 45 anos participaram da pesquisa. Cada paciente deveria ter pelo menos três lesões de cárie oclusais de Classe I nos molares. Eles foram divididos aleatoriamente, com n=20 dentes representando cada material testado. Grupo I (Futurabond M+ e VisCalor Bulk Fill aquecido em dispensador viscolar a 68 °C por 30s e colocado em uma espessura de 4 mm), Grupo II (resina composta autoadesiva Fusio Liquid Dentin colocada em uma camada fina (incremento de 1 mm)) e Grupo III (resina composta Single Bond Universal e Filtek Bulk Fill Posterior aplicado em espessura de 4 mm sem aquecimento). Usando os critérios (USPHS), todas as restaurações foram avaliadas clinicamente no início, 6 meses, 12 meses e 18 meses. Usando uma réplica inversa, o selamento marginal das restaurações investigadas foi avaliado em MEV. A análise estatística foi realizada com o teste qui-quadrado para todos os parâmetros USPH. Resultados: os três grupos testados registraram uma taxa de retenção de cem por cento após um período de acompanhamento de 18 meses. Em relação à adaptação marginal, descoloração marginal, forma anatômica, textura da superfície e combinação de cores, houve uma diferença significativa (p˂0,05) entre os três grupos testados após 12 e 18 meses. Após 12 e 18 meses, a análise SEM do selamento marginal revelou uma diferença estatisticamente significativa entre os três grupos. Conclusão: as restaurações de resina composta Bulk Fill apresentaram desempenho clínico aceitável satisfatório após 18 meses de atendimento clínico em comparação com as resinas compostas fluidas autoadesivas, e a resina composta Viscalor Bulk Fill demonstrou excelentes resultados com mudanças consideráveis na integridade marginal, como consequência da tecnologia viscosa térmica e maior adaptabilidade de restaurações nas paredes e margens da cavidade (AU)


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Microscopy, Electron, Scanning , Malocclusion, Angle Class I
17.
Belo Horizonte; s.n; 2023. 64 p. ilus, graf, tab.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1509346

ABSTRACT

A introdução da liga NiTi na endodontia proporcionou a fabricação de instrumentos com excelentes propriedades mecânicas, e uma das principais características é a possibilidade de alteração das temperaturas de transformação da liga, o qual pode possibilitar a presença de martensita em temperatura ambiente e consequentemente um efeito memória de forma. Entretanto, alguns dos sistemas comercializados atualmente possuem pouca ou nenhuma informação científica relatando suas propriedades mecânicas, características de design e métodos de fabricação. O objetivo deste trabalho foi comparar características geométricas, metalúrgicas e propriedades mecânicas (resistência à torção e flexão) de instrumentos Reciproc Blue (VDW, Munique, Alemanha), e quatro sistemas reciprocantes réplicas. Um total de 39 instrumentos de cada um dos sistemas reciprocantes, Reciproc Blue (RB), Prodesign R (PDR), V File (VF), V+ File (V+) e Univy One (UO) foram utilizados na pesquisa. O programa de Image J foi utilizado para mensuração dos diâmetros a cada milímetro da parte ativa e da área da seção transversal a 3 mm da ponta dos instrumentos. Imagens de MEV da parte ativa foram realizados para avaliar o acabamento superficial dos instrumentos. A composição atômica, fases presentes e temperaturas de transformação foram verificadas através de EDS, DRX e DSC, respectivamente. A flexibilidade foi aferida através de ensaios de dobramento até 45º conforme a especificação ISO 3630-1, e os ensaios de resistência à torção foram realizados de acordo com a especificação Nº28 ANSI/ADA. Todos os instrumentos apresentaram uma quantidade aproximadamente equiatômica de níquel e titânio. A análise qualitativa das fases cristalinas realizada através de ensaios de DRX, demonstrou a predominância de Fase R em todos os grupos, com exceção do grupo UO que apresenta uma mistura de fase R e martensita B19'. Na avaliação da área da seção, o instrumento RB obteve valores intermediários, os instrumentos PDR e V+ possuem menores valores e os instrumentos VF e UO possuem maiores valores. Observou-se grande impacto da geometria sobre as propriedades mecânicas, sendo que aqueles sistemas que apresentavam menor área que RB (PDR, V+) mostraram-se mais flexíveis e menos resistentes à torção (p<0.05), e o instrumento VF que teve maior área apresentou, como esperado, menos flexibilidade (p<0.05) e resistência torcional semelhante (p>0.05). A única exceção se deu com o sistema UO, que embora apresentasse uma maior área de seção, mostrou-se mais flexível e menos resistente à torção, provavelmente por influência da maior quantidade de martensita presente à temperatura ambiente. Nenhum dos instrumentos réplicas avaliados apresentaram características e comportamento mecânico iguais ao sistema padrão RB. Sugere-se que mais estudos devem ser realizados para a comparação do comportamento clínico destes instrumentos.


The introduction of NiTi alloy in endodontics has allowed the manufacturing of instruments with excellent mechanical properties, and one of the main characteristics is the ability to change alloy's transformation temperature, which can enable the presence of martensite at room temperature and consequently favor a shape memory effect. However, some of the currently marketed systems have limited or no scientific information regarding their mechanical properties, design characteristics, and manufacturing methods. The aim of this study was to compare the geometric characteristics, metallurgical aspects, and mechanical properties (torsional and flexural strength) of Reciproc Blue instruments (VDW, Munich, Germany) with four replica-like reciprocating systems. A total amount of 39 instruments from each reciprocating system, namely Reciproc Blue (RB), Prodesign R (PDR), V File (VF), V+ File (V+), and Univy One (UO), were used in the study. The Image J program was used to measure the diameters at every millimeter along the instruments active portion and the cross-sectional area at 3 mm from the instrument tip. SEM images of the active portion were obtained to evaluate the surface finishing of the instruments. Atomic composition, phases present, and transformation temperatures were determined through EDS, XRD, and DSC analyses, respectively. Flexibility was assessed by bending tests up to 45° according to ISO 3630-1 specifications, and torsional strength tests were performed according with ANSI/ADA Specification No. 28. All instruments exhibited an approximately equiatomic composition of nickel and titanium. Qualitative analysis of the crystalline phases using XRD tests demonstrated the predominance of the R-phase in all groups, except for the UO group, which exhibited a mixture of Rphase and B19' martensite. In terms of diameter and cross-sectional area evaluation, the RB instrument obtained intermediate values, while the PDR and V+ instruments had smaller values, and the VF and UO instruments had larger values. A significant impact of geometry on mechanical properties was observed, with systems exhibiting a smaller area than RB (PDR, V+) being more flexible and less torsion-resistant (p<0.05), and the VF instrument with a larger area showed, as expected, less flexibility (p<0.05) and similar torsional resistance (p>0.05). The only exception was the UO system, which, despite having a larger geometric configuration, exhibited greater flexibility and less torsional resistance, likely due to the higher amount of martensite present at room temperature. None of the replica-like instruments evaluated showed identical characteristics and mechanical behavior to the standard RB system. Further studies are suggested to compare the clinical performance of these instruments.


Subject(s)
Calorimetry, Differential Scanning , Endodontics , Torsion, Mechanical , Shape Memory Alloys , Mechanical Tests
18.
Braz. dent. sci ; 26(2): 1-8, 2023. ilus, tab
Article in English | LILACS, BBO | ID: biblio-1426430

ABSTRACT

Objective: in this study, biofilm formation by Candida albicans in fixed orthodontic appliances was evaluated. Material and Methods: a total of 300 conventional metal brackets (MC), ceramic (CB), self-ligation (SLB), nickel-titanium (NiTi), and nickel-chromium (NiCr) wires, and ligatures types were organized into thirty groups (n=10). To induce biofilm formation, brackets, wires, and ligatures were joined, sterilized, placed in 24-well plates, contaminated with standardized suspensions of C. albicans (107 cells/mL), and incubated at 37 °C for 48 h with shaking. The biofilms formed were detached using an ultrasonic homogenizer, and suspensions were serially diluted and plated on Sabouraud dextrose agar to determine colony-forming units per mL. Scanning electron microscopy was performed before and after the biofilm formation. Results: lower amount of biofilm formation was observed in the MC group than in the CB and SLB groups (p<0.0001). SLB and CB showed similar biofilm formation rates (p=0.855). In general, the cross-sectional wires .018"x.025" showed higher biofilm formation when associated with the three types of brackets. When brackets, wires, and ligatures were associated, the sets with NiCr wires and SSL ligatures with MC brackets (p=0.0008) and CB (p=0.0003) showed higher biofilm formation. Conclusion: thus, brackets of MC with NiTi and NiCr wires showed lower biofilm formation, regardless of the ligature and cross-sectional or gauge of the wire and, MC and CB brackets with NiCr wires and SSL ligatures were more likely to accumulate biofilms (AU)


Objetivo: neste estudo, a formação de biofilme por Candida albicans em aparelhos ortodônticos fixos foi avaliada. Material e Métodos: um total de 300 bráquetes metálicos convencionais (MC), cerâmicos (CB), autoligados (SLB), com fios de níquel-titânio (NiTi) e níquel-cromo (NiCr) e tipos de ligaduras foram organizados em trinta grupos (n=10). Bráquetes, fios e ligaduras foram unidos, esterilizados, colocados em placas de 24 poços, contaminados com suspensões padronizadas de C. albicans (107 células/mL) e incubados a 37°C por 48 h para a formação de biofilmes. Os biofilmes formados foram rompidos por meio de um homogeneizador ultrassônico e suspensões foram diluídas e semeadas em ágar Sabouraud-dextrose para determinar as unidades formadoras de colônias por mL. A microscopia eletrônica de varredura foi realizada antes e após a formação do biofilme. Resultados: foi observada menor formação de biofilme no grupo MC em comparação aos grupos CB e SLB (p<0,0001). A formação de biofilme foi semelhante nos grupos SLB e CB (p=0,855). Em geral, os fios de seção transversal .018"x.025" apresentaram maior formação de biofilme quando associados aos três tipos de bráquetes. Os conjuntos com fios de NiCr e ligaduras SSL com bráquetes MC (p=0,0008) e CB (p=0,0003) apresentaram maior formação de biofilme. Conclusão: bráquetes MC com fios de NiTi e NiCr apresentaram menor formação de biofilme, independente da ligadura e secção transversal ou bitola do fio e, braquetes MC e CB com fios de NiCr e ligaduras SSL foram mais propensos a acumular biofilmes.(AU)


Subject(s)
Candida albicans , Microscopy, Electron, Scanning , Orthodontic Brackets , Biofilms , Orthodontic Appliances, Fixed
19.
J. appl. oral sci ; 31: e20230005, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1440411

ABSTRACT

Abstract Irrigation solutions might affect dentin surface characteristics and, consequently, endodontic sealers adhesion. Objective This study analyzed the effect of different final irrigation protocols on push-out bond strength (BS) of AH Plus to dentin seven days and 20 months after obturation. Scanning electron micrographs were obtained from the dentin surface of one sample/group after final irrigation. Methodology Canals of bovine incisors were instrumented and received final irrigation with (n=21): G1 - 2.5% sodium hypochlorite (NaOCl) + distilled water; G2 - 2.5% NaOCl + 17% EDTA; G3 - 2.5% NaOCl + 17% EDTA + 2.5% NaOCl; G4 - 2.5% NaOCl + 17% EDTA + 2% chlorhexidine (CHX); G5 - mixture 5% NaOCl + 18% etidronate (HEDP); and G6 - mixture 5% NaOCl + 10% tetrasodium EDTA (Na4EDTA). After irrigation, one root/group was split and images were obtained by scanning electron microscopy (SEM). The other 20 roots/group were filled with only AH Plus sealer. Three slices/root were used for push-out assessment seven days and 20 months after obturation. One-way analysis of variance and Tukey (α<0.05) were used to compare the results among experimental groups, and unpaired t-test (α<0.05) was used to compare the results of the same group over time. Results The photomicrographs showed that, excepting G1, all groups completely removed the smear layer from the samples. In G2 and G4, the opening of the dentin tubules enlarged. In G3, erosion was observed in the peritubular and intertubular dentin. Values of the BS in the seven days were G2=G3=G4=G5>G6=G1 and in the 20 months were G3=G5>G6=G4>G1=G2. G3, G5, and G6 presented values of BS in 20 months similar to the values of seven days (P>0.05). Conclusions The final irrigation protocols tested produced dentin surfaces with different characteristics. Only G3 and G5 presented high BS values that were stable over time.

20.
Biosci. j. (Online) ; 39: e39047, 2023. ilus, tab, graf
Article in English | LILACS | ID: biblio-1428233

ABSTRACT

Following the adoption of Roundup Ready crops, glyphosate spraying frequency increased, while the use of other herbicide modes of action was neglected. Herbicide-resistant biotypes were reported in three major Conyza species in Brazil, including Conyza bonariensis, increasing growers' bottom line. Considering that leaf surface structures affect proper herbicide deposition, uptake, and performance, this study aimed to characterize epicuticular surface components in glyphosate-resistant (R) and -susceptible (S) C. bonariensis. Conyza spp. seeds were collected in 36 locations in Brazil, and plants were subjected to resistance screening tests by spraying glyphosate at 720 and 1440 g ae ha-1 (0.5X and 1X the label recommended rate, respectively). For resistance level characterization, C. bonariensis biotypes with contrasting responses were selected for glyphosate dose-response assays. Leaf tissues for epicuticular surface analysis were harvested from newly-obtained R and S biotypes at two growth stages. Histological cuts were made on a leaf area of 25 mm² with a blade. Samples were fixed in Karnowsky solution, gradually changed to 100% ethanol, critical-point dried with CO2, and coated with gold, followed by stomatal and trichome density quantification using scanning electron microscopy. Results indicated a poor control with glyphosate in 33 of 36 Conyza spp. biotypes, and a high (31.5) resistance factor was calculated after dose-response trials. Leaf surface analysis indicated that C. bonariensis leaves are amphistomatic and exhibit tectorial trichomes. A higher number of trichomes and altered stomatal density (number.mm²) were quantified in R compared to the S counterpart, potentially reducing glyphosate uptake and effectiveness.


Subject(s)
Plant Leaves/anatomy & histology , Conyza , Herbicides
SELECTION OF CITATIONS
SEARCH DETAIL