Korean Journal of Medical Physics ; : 9-15, 2010.
Article in English | WPRIM | ID: wpr-87909

ABSTRACT

Scatter radiation considerably affects radiographic image quality by reducing image contrast and contributing to a non-uniform background. Images containing a large portion of scatter radiation may result in an incorrect diagnosis. In the past few years, many efforts have been made to reduce the effects of scatter radiation on radiographic images. The purpose of this study is to accurately measure scatter fractions and evaluate the effectiveness of beam-stop arrays. To measure scatter fraction accurately, a beam-stop array and the SFC (Scatter Fraction Calculator) program were developed. Images were obtained using the beam-stop array for both an anti-scatter technique with an anti-scatter grid and an air gap technique. The scatter fractions of the images were measured using the SFC program. Scatter fractions obtained with an anti-scatter grid were evaluated and compared to scatter fractions obtained without an anti-scatter grid. Scatter fractions were also quantitatively measured and evaluated with an air gap technique. The effectiveness of the beam-stop array was demonstrated by quantifying scatter fractions under various conditions. The results showed that a beam-stop array and the SFC program can be used to accurately measure scatter fractions in radiographic images and can be applied for both developing scatter correction methods as well as systems.


Subject(s)
Radiographic Image Enhancement
2.
Korean Journal of Nuclear Medicine ; : 49-56, 2005.
Article in Korean | WPRIM | ID: wpr-182285

ABSTRACT

PURPOSE: Dedicated animal PET is useful equipment for the study of new PET tracer. Recently, microPET R4 was installed in the Korea institute of radiology and medical science. In this study, we measured the characteristics of scanner. MATERIALS AND METHODS: Resolution was measured using a line source (F-18: 65 micro Ci, inner diameter: 0.5 mm). The line source was put in the axial direction and was moved from the center of field of view to outside with 1 mm interval. PET images were reconstructed using a filtered back-projection and ordered subset expectation maximization. Line source (16.5 micro Ci, 78 mm) was put on the center of axial direction to measure the sensitivity when the deadtime was under 1%. Images were acquired during 4 minutes respectively from center to 39 mm outward. Delayed count was subtracted from total count and then decay was corrected for the calculation of sensitivity. Noise equivalent count ratio and scatter fraction were calculated using cylindrical phantom. RESULTS: Spatial resolution of reconstructed image using filtered back-projection was 1.86 mm (radial), 1.95 mm (tangential), 1.95 mm (axial) in the center of field of view, and 2.54 mm, 2.8 mm, 1.61 mm in 2 cm away from the center respectively. Sensitivity was 2.36% at the center of transaxial field of view. Scatter fraction was 20%. Maximal noise equivalent count ratio was 66.4 kcps at 242 kBq/mL. Small animal images were acquired for confirmation of performance. CONCLUSION: Performance characteristics of microPET R4 were similar with reported value. So this will be a useful tool for small animal imaging.


Subject(s)
Animals , Korea , Noise